AMSR Controller. Used to drive Yuken ASR series AC servo motor driven pumps; optimally designed for ASR pump drive to maximize pump performance (included with the ASR series pump). Command signal input 0 to +10V DC, 8ch sequence input / 6ch sequence output. Amplifier capacity codes C/DE/FGI/HJL/KMO. Configured-to-order (RFQ): supply voltage (2 AC200V / 4 AC400V), function select (A standalone / B summation), parameter number.
AMSR Controller. Used to drive Yuken ASR series AC servo motor driven pumps; optimally designed for ASR pump drive to maximize pump performance (included with the ASR series pump). Command signal input 0 to +10V DC, 8ch sequence input / 6ch sequence output. Amplifier capacity codes C/DE/FGI/HJL/KMO. Configured-to-order (RFQ): supply voltage (2 AC200V / 4 AC400V), function select (A standalone / B summation), parameter number.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMSR-C-00-10 | AMSR controller C (5.0kW), for ASR1 (C), ASR2 (C) | Yuken | Amplifier Capacity Code: C (5.0 kW) | Command Signal Input: 0 to +10V DC, input impedance 10 kohm | Monitor Output: 0 to +10V DC | Sequence I/O: 8ch photocoupler input / 6ch open-collector output | Main Circuit Power: 3-phase AC200V / AC400V 50/60Hz (200V: AC170-253V, 400V: AC323-528V, freq +/-5%) | Power Supply Capacity: 6.8 kVA | Regenerative Resistor (DB): Built-in | Cooling: Forced air-cooled, open (IP00) | Ambient: 0 to +50C (no freezing), <=90%RH (no condensation) | Protection: Overcurrent / servo-motor overheat / undervoltage / excessive-error / regen overvoltage / encoder fault / momentary power-loss / overload / regen fault / overspeed | Mass (approx): 4.6 kg | Applicable Pumps: ASR1 (C), ASR2 (C) | Design No: 10 | Options: Supply voltage (2 AC200V / 4 AC400V; DE = AC200V only), function select (A standalone / B summation), parameter number = RFQ | |
| AMSR-DE-00-10 | AMSR controller DE (7.0kW), for ASR3 (E) | Yuken | Amplifier Capacity Code: DE (7.0 kW) | Command Signal Input: 0 to +10V DC, input impedance 10 kohm | Monitor Output: 0 to +10V DC | Sequence I/O: 8ch photocoupler input / 6ch open-collector output | Main Circuit Power: 3-phase AC200V 50/60Hz (200V: AC170-253V, 400V: AC323-528V, freq +/-5%) | Power Supply Capacity: 8.6 kVA | Regenerative Resistor (DB): Built-in | Cooling: Forced air-cooled, open (IP00) | Ambient: 0 to +50C (no freezing), <=90%RH (no condensation) | Protection: Overcurrent / servo-motor overheat / undervoltage / excessive-error / regen overvoltage / encoder fault / momentary power-loss / overload / regen fault / overspeed | Mass (approx): 6.2 kg | Applicable Pumps: ASR3 (E) | Design No: 10 | Options: Supply voltage (2 AC200V / 4 AC400V; DE = AC200V only), function select (A standalone / B summation), parameter number = RFQ | |
| AMSR-FGI-00-10 | AMSR controller FGI (11.0kW), for ASR3 (G), ASR5 (G) | Yuken | Amplifier Capacity Code: FGI (11.0 kW) | Command Signal Input: 0 to +10V DC, input impedance 10 kohm | Monitor Output: 0 to +10V DC | Sequence I/O: 8ch photocoupler input / 6ch open-collector output | Main Circuit Power: 3-phase AC200V / AC400V 50/60Hz (200V: AC170-253V, 400V: AC323-528V, freq +/-5%) | Power Supply Capacity: 12 kVA | Regenerative Resistor (DB): External | Cooling: Forced air-cooled, open (IP00) | Ambient: 0 to +50C (no freezing), <=90%RH (no condensation) | Protection: Overcurrent / servo-motor overheat / undervoltage / excessive-error / regen overvoltage / encoder fault / momentary power-loss / overload / regen fault / overspeed | Mass (approx): 18 kg | Applicable Pumps: ASR3 (G), ASR5 (G) | Design No: 10 | Options: Supply voltage (2 AC200V / 4 AC400V; DE = AC200V only), function select (A standalone / B summation), parameter number = RFQ | |
| AMSR-HJL-00-10 | AMSR controller HJL (15.0kW), for ASR5 (J), ASR10 (J) | Yuken | Amplifier Capacity Code: HJL (15.0 kW) | Command Signal Input: 0 to +10V DC, input impedance 10 kohm | Monitor Output: 0 to +10V DC | Sequence I/O: 8ch photocoupler input / 6ch open-collector output | Main Circuit Power: 3-phase AC200V / AC400V 50/60Hz (200V: AC170-253V, 400V: AC323-528V, freq +/-5%) | Power Supply Capacity: 16 kVA | Regenerative Resistor (DB): External | Cooling: Forced air-cooled, open (IP00) | Ambient: 0 to +50C (no freezing), <=90%RH (no condensation) | Protection: Overcurrent / servo-motor overheat / undervoltage / excessive-error / regen overvoltage / encoder fault / momentary power-loss / overload / regen fault / overspeed | Mass (approx): 18 kg | Applicable Pumps: ASR5 (J), ASR10 (J) | Design No: 10 | Options: Supply voltage (2 AC200V / 4 AC400V; DE = AC200V only), function select (A standalone / B summation), parameter number = RFQ | |
| AMSR-KMO-00-10 | AMSR controller KMO (22.0kW), for ASR10 (M) | Yuken | Amplifier Capacity Code: KMO (22.0 kW) | Command Signal Input: 0 to +10V DC, input impedance 10 kohm | Monitor Output: 0 to +10V DC | Sequence I/O: 8ch photocoupler input / 6ch open-collector output | Main Circuit Power: 3-phase AC200V / AC400V 50/60Hz (200V: AC170-253V, 400V: AC323-528V, freq +/-5%) | Power Supply Capacity: 22 kVA | Regenerative Resistor (DB): External | Cooling: Forced air-cooled, open (IP00) | Ambient: 0 to +50C (no freezing), <=90%RH (no condensation) | Protection: Overcurrent / servo-motor overheat / undervoltage / excessive-error / regen overvoltage / encoder fault / momentary power-loss / overload / regen fault / overspeed | Mass (approx): 19 kg | Applicable Pumps: ASR10 (M) | Design No: 10 | Options: Supply voltage (2 AC200V / 4 AC400V; DE = AC200V only), function select (A standalone / B summation), parameter number = RFQ |