Proportional Valve Amplifiers
[Yuken] β AMB-EL-01 Eurocard High-Response Power Amplifier (for ELDFG-01, compensation by inquiry)
βΆHigh Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL Eurocard (3U, 100Γ160 mm) amplifier for the high-response valve ELDFG-01. For valve size 01 the compensation code is specified separately by inquiry (RFQ); spool form (3C2/3C40 or 3C2P) and I/O code (AβF: voltage Β±10 V / current 4β20 mA / current Β±10 mA, PBAT or PABT) are selected to match the valve. Max output current 2.5 A, supply DC21β28 V, 30 W, mass 280 g, open-collector alarm. Please consult with the matched ELDFG-01 specification.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL Eurocard (3U, 100Γ160 mm) amplifier for the high-response valve ELDFG-01. For valve size 01 the compensation code is specified separately by inquiry (RFQ); spool form (3C2/3C40 or 3C2P) and I/O code (AβF: voltage Β±10 V / current 4β20 mA / current Β±10 mA, PBAT or PABT) are selected to match the valve. Max output current 2.5 A, supply DC21β28 V, 30 W, mass 280 g, open-collector alarm. Please consult with the matched ELDFG-01 specification.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-01 | Yuken AMB-EL-01 Eurocard high-response amplifier for ELDFG-01 (compensation by inquiry, RFQ) | Yuken | Type: Eurocard high-response power amplifier (compensation by inquiry) | Brand: Yuken | Model: AMB-EL-01 | Function: EL (minor-feedback DC-input, Eurocard 3U) | Compatible Valve Size: 01 | Compensation: By separate inquiry (RFQ) | Spool Form: 3C2/3C40 or 3C2P (per valve) | I/O Code: AβF (voltage Β±10 V / current 4β20 mA / current Β±10 mA; PBAT or PABT) per valve | Max Output Current: 2.5 A | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 280 g | Alarm: open collector max DC30V/10 mA | Drives: ELDFG-01 | Design No.: 20 | Note: Compensation/spool/I/O specified per matched valve β RFQ |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFG-03 (valve size 03). Max output current 3.0 A (3Ξ©), command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 40 W, mass 280 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFG-03 (valve size 03). Max output current 3.0 A (3Ξ©), command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 40 W, mass 280 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-03-1-A-20 | Yuken AMB-EL-03-1-A-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-B-20 | Yuken AMB-EL-03-1-B-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-C-20 | Yuken AMB-EL-03-1-C-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-D-20 | Yuken AMB-EL-03-1-D-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-E-20 | Yuken AMB-EL-03-1-E-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-F-20 | Yuken AMB-EL-03-1-F-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-A-20 | Yuken AMB-EL-03-2P-1-A-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-B-20 | Yuken AMB-EL-03-2P-1-B-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-C-20 | Yuken AMB-EL-03-2P-1-C-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-D-20 | Yuken AMB-EL-03-2P-1-D-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-E-20 | Yuken AMB-EL-03-2P-1-E-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-F-20 | Yuken AMB-EL-03-2P-1-F-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 3.0 A (3Ξ©) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-04 (valve size 04). Max output current 2.5 A, command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-04 (valve size 04). Max output current 2.5 A, command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-04-2-A-20 | Yuken AMB-EL-04-2-A-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-B-20 | Yuken AMB-EL-04-2-B-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-C-20 | Yuken AMB-EL-04-2-C-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-D-20 | Yuken AMB-EL-04-2-D-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-E-20 | Yuken AMB-EL-04-2-E-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-F-20 | Yuken AMB-EL-04-2-F-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-A-20 | Yuken AMB-EL-04-2P-2-A-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-B-20 | Yuken AMB-EL-04-2P-2-B-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-C-20 | Yuken AMB-EL-04-2P-2-C-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-D-20 | Yuken AMB-EL-04-2P-2-D-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-E-20 | Yuken AMB-EL-04-2P-2-E-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-F-20 | Yuken AMB-EL-04-2P-2-F-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-06 (valve size 06). Max output current 2.5 A, command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100Γ160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-06 (valve size 06). Max output current 2.5 A, command input selectable by I/O code AβF (voltage Β±10 V, current 4β20 mA, or current Β±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΞ© (voltage) / 200 Ξ© (current), variable dither, slope 0.05β5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21β28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-06-3-A-20 | Yuken AMB-EL-06-3-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-B-20 | Yuken AMB-EL-06-3-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-C-20 | Yuken AMB-EL-06-3-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-D-20 | Yuken AMB-EL-06-3-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-E-20 | Yuken AMB-EL-06-3-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-F-20 | Yuken AMB-EL-06-3-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-A-20 | Yuken AMB-EL-06-2P-3-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-B-20 | Yuken AMB-EL-06-2P-3-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-C-20 | Yuken AMB-EL-06-2P-3-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-D-20 | Yuken AMB-EL-06-2P-3-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-E-20 | Yuken AMB-EL-06-2P-3-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-F-20 | Yuken AMB-EL-06-2P-3-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-A-20 | Yuken AMB-EL-06-4-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-B-20 | Yuken AMB-EL-06-4-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-C-20 | Yuken AMB-EL-06-4-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-D-20 | Yuken AMB-EL-06-4-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-E-20 | Yuken AMB-EL-06-4-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-F-20 | Yuken AMB-EL-06-4-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05β5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-A-20 | Yuken AMB-EL-06-2P-4-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: A (Voltage Β±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-B-20 | Yuken AMB-EL-06-2P-4-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: B (Current 4β20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-C-20 | Yuken AMB-EL-06-2P-4-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: C (Current Β±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-D-20 | Yuken AMB-EL-06-2P-4-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: D (Voltage Β±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-E-20 | Yuken AMB-EL-06-2P-4-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: E (Current 4β20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-F-20 | Yuken AMB-EL-06-2P-4-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100Γ160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: F (Current Β±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21β28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 |
Yuken dual-channel DC-input power amplifier for 10Ξ©-10Ξ© power-saving valves. It can drive two 10Ξ© solenoids simultaneously or individually for combined pressure and flow control; the front-panel controls are marked PRESS and FLOW but the two circuits are identical, so either may be used. Drives the EFBG power-saving (relief-built-in flow control) valves and the other 10Ξ©-series valves (EDG/EBG/ERBG/EFG/EFCG[51]), and also the A-series proportional load-sensing variable piston pumps. Max output current 1 A (10Ξ© solenoid), max command input DC +10 V, input impedance 10 kΞ©, max gain 1 A/5 V, variable dither 100β300 mA, temperature drift 0.2 mA/Β°C. Common AC100V/200V supply (50/60 Hz), 120 VA, mass 4.3 kg.
Yuken dual-channel DC-input power amplifier for 10Ξ©-10Ξ© power-saving valves. It can drive two 10Ξ© solenoids simultaneously or individually for combined pressure and flow control; the front-panel controls are marked PRESS and FLOW but the two circuits are identical, so either may be used. Drives the EFBG power-saving (relief-built-in flow control) valves and the other 10Ξ©-series valves (EDG/EBG/ERBG/EFG/EFCG[51]), and also the A-series proportional load-sensing variable piston pumps. Max output current 1 A (10Ξ© solenoid), max command input DC +10 V, input impedance 10 kΞ©, max gain 1 A/5 V, variable dither 100β300 mA, temperature drift 0.2 mA/Β°C. Common AC100V/200V supply (50/60 Hz), 120 VA, mass 4.3 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D2-1010-11 | Yuken AME-D2-1010-11 dual-channel power amplifier for 10ohm-10ohm power-saving valves | Yuken | Type: Dual-channel power amplifier for 10Ξ©-10Ξ© power-saving valves (pressure + flow) | Brand: Yuken | Model: AME-D2-1010-11 | Function: D2 (DC input, pressure & flow control) | Load: 1010 (10Ξ© Γ 2) | Max Output Current: 1 A (10Ξ© solenoid) | Max Command Input: DC +10 V | Input Impedance: 10 kΞ© | Max Gain: 1 A / 5 V | Dither: variable 100β300 mA | Temp Drift: 0.2 mA/Β°C | Power Supply: AC 100 V/200 V common (50/60 Hz) | Power Consumption: 120 VA | External Setter: 1 kΞ© | Mass: 4.3 kg | Drives: EFBG power-saving valves; 10Ξ© valves; A-series load-sensing piston pumps | Design No.: 11 |
Yuken compact DC24V power amplifier for 10Ξ© proportional solenoid valves. A newly designed circuit gives lower heat generation than earlier models in a small package. Drives the 10Ξ©-series proportional electro-hydraulic control valves (EDG pilot relief, EBG relief, ERBG relieving/reducing, EFG/EFCG flow control [design 51], EFBG power-saving). Max output current 1 A (10Ξ© solenoid), max command input DC +10 V, input impedance 10 kΞ©, max gain 1 A/5 V, internal variable dither, temperature drift 0.2 mA/Β°C. Supply DC24V (20β30 V incl. ripple), 25 W. No power switch (operates as soon as powered β fit an external switch). External setter potentiometer 1 kΞ©. Mass 0.2 kg.
Yuken compact DC24V power amplifier for 10Ξ© proportional solenoid valves. A newly designed circuit gives lower heat generation than earlier models in a small package. Drives the 10Ξ©-series proportional electro-hydraulic control valves (EDG pilot relief, EBG relief, ERBG relieving/reducing, EFG/EFCG flow control [design 51], EFBG power-saving). Max output current 1 A (10Ξ© solenoid), max command input DC +10 V, input impedance 10 kΞ©, max gain 1 A/5 V, internal variable dither, temperature drift 0.2 mA/Β°C. Supply DC24V (20β30 V incl. ripple), 25 W. No power switch (operates as soon as powered β fit an external switch). External setter potentiometer 1 kΞ©. Mass 0.2 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-D-10 | Yuken AMN-D-10 compact DC24V power amplifier for 10ohm proportional control valves | Yuken | Type: Compact power amplifier for 10Ξ© proportional control valves | Brand: Yuken | Model: AMN-D-10 | Function: DC input type | Power Supply: DC 24 V (20β30 V incl. ripple) | Max Output Current: 1 A (10Ξ© solenoid) | Max Command Input: DC +10 V | Input Impedance: 10 kΞ© | Max Gain: 1 A / 5 V | Dither: Internal, variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 25 W | Power Switch: None (fit external switch) | External Setter: 1 kΞ© potentiometer | Mass: 0.2 kg | Dimensions: 60 Γ 100 Γ 30 mm | Drives: 10Ξ© valves (EDG/EBG/ERBG/EFG/EFCG[51]/EFBG) | Design No.: 10 |
Yuken DC24V power amplifiers for the shockless-type proportional directional & flow control valve EDFG-01. Two types: AMN-G-10 is a shockless pattern (sequence-input) amplifier with selectable output patterns and slope-time setting; AMN-W-10 is a DC analog-input amplifier with a delay function. Both: max output current 1.3 A (10Ξ© solenoid), variable dither, temperature drift 0.2 mA/Β°C, supply DC24V (20β30 V incl. ripple), 25 W, mass 0.2 kg. No power switch (operates as soon as powered β fit an external switch).
Yuken DC24V power amplifiers for the shockless-type proportional directional & flow control valve EDFG-01. Two types: AMN-G-10 is a shockless pattern (sequence-input) amplifier with selectable output patterns and slope-time setting; AMN-W-10 is a DC analog-input amplifier with a delay function. Both: max output current 1.3 A (10Ξ© solenoid), variable dither, temperature drift 0.2 mA/Β°C, supply DC24V (20β30 V incl. ripple), 25 W, mass 0.2 kg. No power switch (operates as soon as powered β fit an external switch).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-G-10 | Yuken AMN-G-10 power amplifier for EDFG-01 shockless directional & flow valve | Yuken | Type: Power amplifier for shockless directional & flow control valve (EDFG-01) | Brand: Yuken | Model: AMN-G-10 | Function: G (shockless / pattern type) | Max Output Current: 1.3 A (10Ξ© solenoid) | Features: Sequence-input shockless control: setting resolution 0β99% in 1% steps, 3 output patterns each for SOL a and SOL b, slope (ramp) time 1β99 s (0β99% adjust). Sequence input 10 mA/24 V, input voltage range 10β28 V. | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Supply: DC24V (20β30 V incl. ripple) | Power Consumption: 25 W | Mass: 0.2 kg | Drives: EDFG-01 shockless directional & flow valve | Design No.: 10 | |
| AMN-W-10 | Yuken AMN-W-10 power amplifier for EDFG-01 shockless directional & flow valve | Yuken | Type: Power amplifier for shockless directional & flow control valve (EDFG-01) | Brand: Yuken | Model: AMN-W-10 | Function: W (DC input / analog type) | Max Output Current: 1.3 A (10Ξ© solenoid) | Features: DC analog input: SOL a at DC -10 V, SOL b at DC +10 V; input impedance 10 kΞ©, max gain 1.3 A/Β±5 V, delay-time adjustment 0.1β3 s. | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Supply: DC24V (20β30 V incl. ripple) | Power Consumption: 25 W | Mass: 0.2 kg | Drives: EDFG-01 shockless directional & flow valve | Design No.: 10 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMN-L is the compact minor-feedback DC-input amplifier for the high-response direct-operated directional & flow control valve ELDFG-01. Max output current 2.5 A (3.9Ξ© solenoid), command input Β±10 V (PβBβAβT / PβAβBβT), input impedance β₯10 kΞ©, variable dither, slope 0.03β5 s, spool-displacement monitor Β±1.5 V/Β±3 mm, open-collector alarm (max DC30V/10 mA). Supply DC24V (20β30 V incl. ripple), 75 W, mass 300 g. The compensation code matches the spool (1 = 3C2/3C40, 3 = 3C2P).
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMN-L is the compact minor-feedback DC-input amplifier for the high-response direct-operated directional & flow control valve ELDFG-01. Max output current 2.5 A (3.9Ξ© solenoid), command input Β±10 V (PβBβAβT / PβAβBβT), input impedance β₯10 kΞ©, variable dither, slope 0.03β5 s, spool-displacement monitor Β±1.5 V/Β±3 mm, open-collector alarm (max DC30V/10 mA). Supply DC24V (20β30 V incl. ripple), 75 W, mass 300 g. The compensation code matches the spool (1 = 3C2/3C40, 3 = 3C2P).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-L-01-1-10 | Yuken AMN-L-01-1-10 compact high-response amplifier for ELDFG-01, comp 1, 3C2/3C40 (overlap) | Yuken | Type: Compact high-response power amplifier (ELDFG-01) | Brand: Yuken | Model: AMN-L-01-1-10 | Function: L (minor-feedback DC-input directional/flow) | Compatible Valve Size: 01 | Compensation: 1 | Spool Form: 3C2/3C40 (overlap) | Max Output Current: 2.5 A (3.9Ξ©) | Command Input: Β±10 V | Slope: 0.03β5 s | Spool Monitor: Β±1.5 V/Β±3 mm | Alarm: open collector max DC30V/10 mA | Power Supply: DC24V (20β30 V incl. ripple) | Power Consumption: 75 W | Mass: 300 g | Drives: ELDFG-01 | Design No.: 10 | |
| AMN-L-01-3-2P-10 | Yuken AMN-L-01-3-2P-10 compact high-response amplifier for ELDFG-01, comp 3, 3C2P (zero-lap) | Yuken | Type: Compact high-response power amplifier (ELDFG-01) | Brand: Yuken | Model: AMN-L-01-3-2P-10 | Function: L (minor-feedback DC-input directional/flow) | Compatible Valve Size: 01 | Compensation: 3 | Spool Form: 3C2P (zero-lap) | Max Output Current: 2.5 A (3.9Ξ©) | Command Input: Β±10 V | Slope: 0.03β5 s | Spool Monitor: Β±1.5 V/Β±3 mm | Alarm: open collector max DC30V/10 mA | Power Supply: DC24V (20β30 V incl. ripple) | Power Consumption: 75 W | Mass: 300 g | Drives: ELDFG-01 | Design No.: 10 |
Yuken dedicated power amplifiers that drive the proportional solenoids of 10Ξ©-series proportional electro-hydraulic control valves (e.g. EDG pilot relief, EBG relief, ERBG relieving/reducing), converting a command signal into a proportional solenoid drive current. Available as AC-powered rack types (AME-D-10, SK1022-A/B with command-feedback) and a compact DC24V lead-wire type (SK1015). The full order code carries a valve-matching option (β») specified per matched valve.
Yuken dedicated power amplifiers that drive the proportional solenoids of 10Ξ©-series proportional electro-hydraulic control valves (e.g. EDG pilot relief, EBG relief, ERBG relieving/reducing), converting a command signal into a proportional solenoid drive current. Available as AC-powered rack types (AME-D-10, SK1022-A/B with command-feedback) and a compact DC24V lead-wire type (SK1015). The full order code carries a valve-matching option (β») specified per matched valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D-10 | Yuken AME-D-10 power amplifier for 10ohm proportional control valves, AC 100/200 V, Rack type | Yuken | Type: Power amplifier for 10Ξ© proportional control valves | Brand: Yuken | Model: AME-D-10 | Order Code: AME-D-10-β»-20 (β» = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200 V | Form: Rack type | Features: Manual-setter (MC-01) compatible, MAX/zero/dither adjustment, output-current meter; +12V internal supply | Dimensions: 80 Γ 199 Γ 185.5 mm | Drives: 10Ξ© proportional control valves (EDG / EBG / ERBG) | |
| SK1022-A | Yuken SK1022-A power amplifier for 10ohm proportional control valves, AC 100/200/220 V, Rack type (feedback) | Yuken | Type: Power amplifier for 10Ξ© proportional control valves | Brand: Yuken | Model: SK1022-A | Order Code: SK1022-A-β»-11 (β» = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200/220 V | Form: Rack type (feedback) | Features: Feedback type (REF/F.B), gain/null/dither and reference/input-ratio adjustment, output-current meter | Dimensions: 125 Γ 199 Γ 260 mm | Drives: 10Ξ© proportional control valves (EDG / EBG / ERBG) | |
| SK1022-B | Yuken SK1022-B power amplifier for 10ohm proportional control valves, AC 100/200/220 V, Rack type (feedback) | Yuken | Type: Power amplifier for 10Ξ© proportional control valves | Brand: Yuken | Model: SK1022-B | Order Code: SK1022-B-β»-11 (β» = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200/220 V | Form: Rack type (feedback) | Features: Feedback type (REF/F.B), gain/null/dither and reference/input-ratio adjustment, output-current meter | Dimensions: 125 Γ 199 Γ 260 mm | Drives: 10Ξ© proportional control valves (EDG / EBG / ERBG) | |
| SK1015 | Yuken SK1015 power amplifier for 10ohm proportional control valves, DC 24 V, Compact lead-wire type | Yuken | Type: Power amplifier for 10Ξ© proportional control valves | Brand: Yuken | Model: SK1015 | Order Code: SK1015-11 (β» = valve-matching option, specify per valve / RFQ) | Power Supply: DC 24 V | Form: Compact lead-wire type | Features: Compact lead-wire amplifier, zero/gain adjustment; no power switch (operates as soon as power applied β fit external switch). Setter potentiometer 10 kΞ© | Dimensions: 120 Γ 85 Γ 45 mm | Drives: 10Ξ© proportional control valves (EDG / EBG / ERBG) |
Yuken dedicated power amplifiers that drive the proportional solenoids of 40Ξ©-series flow control valves (EFG/EFCG, design 31/26/22/11). The AME-D type is a DC-command-input amplifier and AME-DF adds command feedback; both are available in wall-mount (D only) or panel-mount and with AC (85β230 V) or DC (20β55 V) supply. The AME-T type is an acceleration/deceleration-signal amplifier with adjustable ramp (0.05β1 s per 100 mA), AC100V or AC200/220V supply. Max output current 0.8 A (40Ξ© solenoid; 1.0 A for 10Ξ©), factory-set max output 0.8 A.
Yuken dedicated power amplifiers that drive the proportional solenoids of 40Ξ©-series flow control valves (EFG/EFCG, design 31/26/22/11). The AME-D type is a DC-command-input amplifier and AME-DF adds command feedback; both are available in wall-mount (D only) or panel-mount and with AC (85β230 V) or DC (20β55 V) supply. The AME-T type is an acceleration/deceleration-signal amplifier with adjustable ramp (0.05β1 s per 100 mA), AC100V or AC200/220V supply. Max output current 0.8 A (40Ξ© solenoid; 1.0 A for 10Ξ©), factory-set max output 0.8 A.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D-AC-50 | Yuken AME-D-AC-50 power amplifier for 40ohm flow control valves, DC command-input type, Wall mount, AC 85β230 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-D-AC-50 | Function: D (DC command-input type) | Mounting: Wall mount | Power Supply: AC 85β230 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 1.1 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-DC-50 | Yuken AME-D-DC-50 power amplifier for 40ohm flow control valves, DC command-input type, Wall mount, DC 20β55 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-D-DC-50 | Function: D (DC command-input type) | Mounting: Wall mount | Power Supply: DC 20β55 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 1.1 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-S-AC-50 | Yuken AME-D-S-AC-50 power amplifier for 40ohm flow control valves, DC command-input type, Panel mount, AC 85β230 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-D-S-AC-50 | Function: D (DC command-input type) | Mounting: Panel mount | Power Supply: AC 85β230 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 2.1 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-S-DC-50 | Yuken AME-D-S-DC-50 power amplifier for 40ohm flow control valves, DC command-input type, Panel mount, DC 20β55 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-D-S-DC-50 | Function: D (DC command-input type) | Mounting: Panel mount | Power Supply: DC 20β55 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 2.1 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-DF-S-AC-50 | Yuken AME-DF-S-AC-50 power amplifier for 40ohm flow control valves, DC command-input feedback type, Panel mount, AC 85β230 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-DF-S-AC-50 | Function: DF (DC command-input feedback type) | Mounting: Panel mount | Power Supply: AC 85β230 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) ; Feedback input DC Β±10 V (differential) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 2.2 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-DF-S-DC-50 | Yuken AME-DF-S-DC-50 power amplifier for 40ohm flow control valves, DC command-input feedback type, Panel mount, DC 20β55 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves | Brand: Yuken | Model: AME-DF-S-DC-50 | Function: DF (DC command-input feedback type) | Mounting: Panel mount | Power Supply: DC 20β55 V | Max Output Current: 0.8 A (40Ξ© solenoid) / 1.0 A (10Ξ©); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) ; Feedback input DC Β±10 V (differential) | Input Impedance: 10 kΞ© | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/Β°C | Power Consumption: 50 W | Mass: 2.2 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 50 | |
| AME-T-S-100-22 | Yuken AME-T-S-100-22 accel/decel power amplifier for 40ohm flow control valves, AC 100 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves (accel/decel signal type) | Brand: Yuken | Model: AME-T-S-100-22 | Function: T (acceleration/deceleration signal type) | Mounting: Panel mount | Power Supply: AC 100 V Β±10% (50/60 Hz) | Max Output Current: 0.8 A (40Ξ© solenoid) | Accel/Decel Ramp: 0.05β1 s / 100 mA | Dither: fixed | Temp Drift: 0.2 mA/Β°C | Power Consumption: 90 VA | Mass: 4.5 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 22 | |
| AME-T-S-200-22 | Yuken AME-T-S-200-22 accel/decel power amplifier for 40ohm flow control valves, AC 200/220 V | Yuken | Type: Power amplifier for 40Ξ© flow control valves (accel/decel signal type) | Brand: Yuken | Model: AME-T-S-200-22 | Function: T (acceleration/deceleration signal type) | Mounting: Panel mount | Power Supply: AC 200/220 V Β±10% (50/60 Hz) | Max Output Current: 0.8 A (40Ξ© solenoid) | Accel/Decel Ramp: 0.05β1 s / 100 mA | Dither: fixed | Temp Drift: 0.2 mA/Β°C | Power Consumption: 90 VA | Mass: 4.5 kg | Drives: 40Ξ© EFG/EFCG flow control valves | Design No.: 22 |
Yuken DC24V power amplifier for proportional directional & flow control valves (EDFHG-03/04/06). Two outputs (SOL a / SOL b) set valve direction, with an adjustable delay (DELAY) function 0.15β3 s for shockless transitions. Max output current 1 A (10Ξ© solenoid), command input SOL a: DC -10 V / SOL b: DC +10 V, input impedance 10 kΞ©, max gain 1 A/Β±5 V, variable dither, temperature drift 0.2 mA/Β°C. Supply DC24V (21β28 V incl. ripple, β₯1.5 A capacity), 25 W, external setter 2 kΞ©, mass 1.0 kg. No power switch (operates as soon as powered β fit an external switch).
Yuken DC24V power amplifier for proportional directional & flow control valves (EDFHG-03/04/06). Two outputs (SOL a / SOL b) set valve direction, with an adjustable delay (DELAY) function 0.15β3 s for shockless transitions. Max output current 1 A (10Ξ© solenoid), command input SOL a: DC -10 V / SOL b: DC +10 V, input impedance 10 kΞ©, max gain 1 A/Β±5 V, variable dither, temperature drift 0.2 mA/Β°C. Supply DC24V (21β28 V incl. ripple, β₯1.5 A capacity), 25 W, external setter 2 kΞ©, mass 1.0 kg. No power switch (operates as soon as powered β fit an external switch).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| SK1091-D24-10 | Yuken SK1091-D24-10 DC24V power amplifier for EDFHG directional & flow control valves | Yuken | Type: Power amplifier for directional & flow control valves (EDFHG) | Brand: Yuken | Model: SK1091-D24-10 | Power Supply: DC 24 V (21β28 V incl. ripple) | Supply Capacity: β₯1.5 A | Max Output Current: 1 A (10Ξ© solenoid) | Command Input: SOL a DC -10 V / SOL b DC +10 V | Input Impedance: 10 kΞ© | Max Gain: 1 A/Β±5 V | Dither: variable | Delay Function: 0.15β3 s | Temp Drift: 0.2 mA/Β°C | Power Consumption: 25 W | External Setter: 2 kΞ© | Mass: 1.0 kg | Drives: EDFHG-03/04/06 directional & flow control valves | Design No.: 10 |
Yuken DC-input power amplifier for the high-performance proportional power-saving valve ELFBG-03. Provides LVDT spool-position feedback, a slope (ramp) function and an alarm output for stable, high-accuracy flow control. The compensation code (1 or 2) is matched to the valve flow rating (1 = ELFBG-03-125, 2 = ELFBG-03-170). Max output current 2.5 A, command input 0 to +10 V, input impedance β₯10 kΞ©, sensor-monitor output -0.5 V/1 mm stroke, alarm output max DC30V/10 mA. Supply DC24V (20β30 V incl. ripple), mass 0.3 kg. No power switch (operates as soon as powered β fit an external switch).
Yuken DC-input power amplifier for the high-performance proportional power-saving valve ELFBG-03. Provides LVDT spool-position feedback, a slope (ramp) function and an alarm output for stable, high-accuracy flow control. The compensation code (1 or 2) is matched to the valve flow rating (1 = ELFBG-03-125, 2 = ELFBG-03-170). Max output current 2.5 A, command input 0 to +10 V, input impedance β₯10 kΞ©, sensor-monitor output -0.5 V/1 mm stroke, alarm output max DC30V/10 mA. Supply DC24V (20β30 V incl. ripple), mass 0.3 kg. No power switch (operates as soon as powered β fit an external switch).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| SK1115-1-20 | Yuken SK1115-1-20 power amplifier for ELFBG-03 high-performance power-saving valve (For ELFBG-03-125) | Yuken | Type: Power amplifier for high-performance power-saving valve (ELFBG-03) | Brand: Yuken | Model: SK1115-1-20 | Compensation: 1 (For ELFBG-03-125) | Function: DC input type | Max Output Current: 2.5 A | Command Input: 0 to +10 V | Input Impedance: β₯10 kΞ© | Feedback: LVDT (spool position) | Slope Function: Yes | Sensor Monitor Output: -0.5 V / 1 mm stroke | Alarm Output: max DC30V / 10 mA | Power Supply: DC24V (20β30 V incl. ripple) | Mass: 0.3 kg | Drives: ELFBG-03 high-performance power-saving valve | Design No.: 20 | |
| SK1115-2-20 | Yuken SK1115-2-20 power amplifier for ELFBG-03 high-performance power-saving valve (For ELFBG-03-170) | Yuken | Type: Power amplifier for high-performance power-saving valve (ELFBG-03) | Brand: Yuken | Model: SK1115-2-20 | Compensation: 2 (For ELFBG-03-170) | Function: DC input type | Max Output Current: 2.5 A | Command Input: 0 to +10 V | Input Impedance: β₯10 kΞ© | Feedback: LVDT (spool position) | Slope Function: Yes | Sensor Monitor Output: -0.5 V / 1 mm stroke | Alarm Output: max DC30V / 10 mA | Power Supply: DC24V (20β30 V incl. ripple) | Mass: 0.3 kg | Drives: ELFBG-03 high-performance power-saving valve | Design No.: 20 |