Circuit Breakers
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32BKE family. | Application: Industrial distribution panel (MCB). | Frame: 30AF | Type: Standard MCB (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: Trip range (14~40)×In | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / — | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32BKE family. | Application: Industrial distribution panel (MCB). | Frame: 30AF | Type: Standard MCB (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: Trip range (14~40)×In | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / — | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32BKE/15 | BKE 32BKE — 32BKE 15A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Standard MCB (with auxiliary contact compatibility) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal | Trip curve: Trip range (14~40)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | |
| 32BKE/20 | BKE 32BKE — 32BKE 20A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Standard MCB (with auxiliary contact compatibility) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal | Trip curve: Trip range (14~40)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | |
| 32BKE/30 | BKE 32BKE — 32BKE 30A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Standard MCB (with auxiliary contact compatibility) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal | Trip curve: Trip range (14~40)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) |
LS ELECTRIC Beyond X Residential MCB/RCBO 32BKE-K family. | Application: Residential distribution panel (MCB). | Frame: 32AF | Type: Standard (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: C (5~10×In), D' | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32BKE-K family. | Application: Residential distribution panel (MCB). | Frame: 32AF | Type: Standard (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: C (5~10×In), D' | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32BKE-K | [LS ELECTRIC] — 32BKE-K Beyond X Residential MCB/RCBO (Standard (with auxiliary contact compatibility), 32AF MCB, 5kA @ 220V AC, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32EGR family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BKE-series compatible) | Trip method: Thermal + RCD | Trip curve: Thermal standard | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 4613 / — | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32EGR family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BKE-series compatible) | Trip method: Thermal + RCD | Trip curve: Thermal standard | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 4613 / — | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32EGR/15/15, 30 | EGR 32EGR — 32EGR 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BKE-series compatible) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal + RCD | Trip curve: Thermal standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32EGR/20/15, 30 | EGR 32EGR — 32EGR 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BKE-series compatible) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal + RCD | Trip curve: Thermal standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32EGR/30/15, 30 | EGR 32EGR — 32EGR 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BKE-series compatible) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal + RCD | Trip curve: Thermal standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Residential MCB/RCBO 32EGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal trip, BKE-compatible) | Trip method: Thermal + RCD | Trip curve: D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32EGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal trip, BKE-compatible) | Trip method: Thermal + RCD | Trip curve: D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32EGR-K | [LS ELECTRIC] — 32EGR-K Beyond X Residential MCB/RCBO (Standard RCBO (Thermal trip, BKE-compatible), 32AF RCBO, 5kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GR-cd family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KS 4613 / — | Note: 32GRc=1.5kA, 32GRd=2.5kA | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GR-cd family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KS 4613 / — | Note: 32GRc=1.5kA, 32GRd=2.5kA | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32GRc/15/15, 30 | GR 32GR-cd — 32GRc 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA | |
| 32GRc/20/15, 30 | GR 32GR-cd — 32GRc 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA | |
| 32GRc/30/15, 30 | GR 32GR-cd — 32GRc 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA | |
| 32GRd/15/15, 30 | GR 32GR-cd — 32GRd 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA | |
| 32GRd/20/15, 30 | GR 32GR-cd — 32GRd 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA | |
| 32GRd/30/15, 30 | GR 32GR-cd — 32GRd 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BS-series compatible) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32GRc=1.5kA, 32GRd=2.5kA |
LS ELECTRIC Beyond X Residential MCB/RCBO 32GR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal-Magnetic) | Trip method: Thermal-Magnetic + RCD | Trip curve: D (10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / — | Note: 32GRc-K=1.5kA, 32GRd-K=2.5kA | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32GR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal-Magnetic) | Trip method: Thermal-Magnetic + RCD | Trip curve: D (10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / — | Note: 32GRc-K=1.5kA, 32GRd-K=2.5kA | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32GR-K | [LS ELECTRIC] — 32GR-K Beyond X Residential MCB/RCBO (Standard RCBO (Thermal-Magnetic), 32AF RCBO, 1.5/2.5kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-H family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: H-type RCBO (high-h variant, highest breaking) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 3.5kA @ 220V AC / 3.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-H family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: H-type RCBO (high-h variant, highest breaking) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 3.5kA @ 220V AC / 3.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32GRhH/15/15, 30 | GR 32GRh-H — 32GRhH 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: H-type RCBO (high-h variant, highest breaking) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 3.5kA @ 220V AC / 3.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhH/20/15, 30 | GR 32GRh-H — 32GRhH 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: H-type RCBO (high-h variant, highest breaking) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 3.5kA @ 220V AC / 3.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhH/30/15, 30 | GR 32GRh-H — 32GRhH 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: H-type RCBO (high-h variant, highest breaking) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 3.5kA @ 220V AC / 3.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-H family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: H-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 3kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-H family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: H-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 3kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32GRh-K-H | [LS ELECTRIC] — 32GRh-K-H Beyond X Residential MCB/RCBO (H-type RCBO (bidirectional connection -KB), 32AF RCBO, 3kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-N family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: N-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 1.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-N family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: N-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 1.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32GRh-K-N | [LS ELECTRIC] — 32GRh-K-N Beyond X Residential MCB/RCBO (N-type RCBO (bidirectional connection -KB), 32AF RCBO, 1.5kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-S family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: S-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32GRh-K-S family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: S-type RCBO (bidirectional connection -KB) | Trip method: Thermal-Magnetic + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32GRh-K-S | [LS ELECTRIC] — 32GRh-K-S Beyond X Residential MCB/RCBO (S-type RCBO (bidirectional connection -KB), 32AF RCBO, 2.5kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-N family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: N-type RCBO (high-h variant) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5kA @ 220V AC / 1.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-N family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: N-type RCBO (high-h variant) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5kA @ 220V AC / 1.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32GRhN/15/15, 30 | GR 32GRh-N — 32GRhN 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: N-type RCBO (high-h variant) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5kA @ 220V AC / 1.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhN/20/15, 30 | GR 32GRh-N — 32GRhN 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: N-type RCBO (high-h variant) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5kA @ 220V AC / 1.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhN/30/15, 30 | GR 32GRh-N — 32GRhN 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: N-type RCBO (high-h variant) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5kA @ 220V AC / 1.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-S family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: S-type RCBO (high-h variant) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 2.5kA @ 220V AC / 2.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32GRh-S family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: S-type RCBO (high-h variant) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 2.5kA @ 220V AC / 2.5kA @ 230V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220/230V | Standard: KS 4613 / — | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32GRhS/15/15, 30 | GR 32GRh-S — 32GRhS 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: S-type RCBO (high-h variant) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 2.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhS/20/15, 30 | GR 32GRh-S — 32GRhS 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: S-type RCBO (high-h variant) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 2.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 32GRhS/30/15, 30 | GR 32GRh-S — 32GRhS 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: S-type RCBO (high-h variant) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 2.5kA @ 230V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220/230V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32KGR family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KS 4613 / — | Note: 32KGRc=1.5kA, 32KGRd=2.5kA | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 32KGR family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KS 4613 / — | Note: 32KGRc=1.5kA, 32KGRd=2.5kA | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 32KGRc/15/15, 30 | KGR 32KGR — 32KGRc 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA | |
| 32KGRc/20/15, 30 | KGR 32KGR — 32KGRc 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA | |
| 32KGRc/30/15, 30 | KGR 32KGR — 32KGRc 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA | |
| 32KGRd/15/15, 30 | KGR 32KGR — 32KGRd 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA | |
| 32KGRd/20/15, 30 | KGR 32KGR — 32KGRd 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA | |
| 32KGRd/30/15, 30 | KGR 32KGR — 32KGRd 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: Standard RCBO (BK-series compatible) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic + RCD | Trip curve: Thermal-Magnetic standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | Variant: 32KGRc=1.5kA, 32KGRd=2.5kA |
LS ELECTRIC Beyond X Residential MCB/RCBO 32KGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal trip, BS-K compatible) | Trip method: Thermal + RCD | Trip curve: D (10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / — | Note: 32KGRc-K=1.5kA, 32KGRd-K=2.5kA | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 32KGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: Standard RCBO (Thermal trip, BS-K compatible) | Trip method: Thermal + RCD | Trip curve: D (10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / — | Note: 32KGRc-K=1.5kA, 32KGRd-K=2.5kA | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-32KGR-K | [LS ELECTRIC] — 32KGR-K Beyond X Residential MCB/RCBO (Standard RCBO (Thermal trip, BS-K compatible), 32AF RCBO, 1.5/2.5kA @ 220V AC, 15, 30mA, 16~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52BKE family. | Application: Industrial distribution panel (MCB). | Frame: 50AF | Type: Standard MCB (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: Trip range (8~15)×In | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / — | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52BKE family. | Application: Industrial distribution panel (MCB). | Frame: 50AF | Type: Standard MCB (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: Trip range (8~15)×In | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / — | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 52BKE/40 | BKE 52BKE — 52BKE 40A 2P (MCB) | LS ELECTRIC | Frame: 50AF | Type: Standard MCB (with auxiliary contact compatibility) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal | Trip curve: Trip range (8~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | |
| 52BKE/50 | BKE 52BKE — 52BKE 50A 2P (MCB) | LS ELECTRIC | Frame: 50AF | Type: Standard MCB (with auxiliary contact compatibility) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal | Trip curve: Trip range (8~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) |
LS ELECTRIC Beyond X Residential MCB/RCBO 52BKE-K family. | Application: Residential distribution panel (MCB). | Frame: 50AF | Type: Standard (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: C (5~10×In), D' | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 52BKE-K family. | Application: Residential distribution panel (MCB). | Frame: 50AF | Type: Standard (with auxiliary contact compatibility) | Trip method: Thermal | Trip curve: C (5~10×In), D' | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-52BKE-K | [LS ELECTRIC] — 52BKE-K Beyond X Residential MCB/RCBO (Standard (with auxiliary contact compatibility), 50AF MCB, 5kA @ 220V AC, 40~50A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52EGR family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: Standard RCBO (BKE-series compatible) | Trip method: Thermal + RCD | Trip curve: Thermal standard | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 4613 / — | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52EGR family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: Standard RCBO (BKE-series compatible) | Trip method: Thermal + RCD | Trip curve: Thermal standard | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 4613 / — | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 52EGR/40/15, 30 | EGR 52EGR — 52EGR 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: Standard RCBO (BKE-series compatible) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal + RCD | Trip curve: Thermal standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 52EGR/50/15, 30 | EGR 52EGR — 52EGR 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: Standard RCBO (BKE-series compatible) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal + RCD | Trip curve: Thermal standard | Sensitivity (I△n): 15, 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Residential MCB/RCBO 52EGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: Standard RCBO (Thermal trip, BKE-compatible) | Trip method: Thermal + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 5 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO 52EGR-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: Standard RCBO (Thermal trip, BKE-compatible) | Trip method: Thermal + RCD | Trip curve: C (5~10×In), D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 5 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-52EGR-K | [LS ELECTRIC] — 52EGR-K Beyond X Residential MCB/RCBO (Standard RCBO (Thermal trip, BKE-compatible), 50AF RCBO, 5kA @ 220V AC, 15, 30mA, 16~50A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52GRb family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Rated current (In): 15A, 20A, 30A, 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KS 4613 / — | 5 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO 52GRb family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Rated current (In): 15A, 20A, 30A, 40A, 50A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KS 4613 / — | 5 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 52GRb/15/30 | GR 52GRb — 52GRb 15A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 52GRb/20/30 | GR 52GRb — 52GRb 20A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 52GRb/30/30 | GR 52GRb — 52GRb 30A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 52GRb/40/30 | GR 52GRb — 52GRb 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) | |
| 52GRb/50/30 | GR 52GRb — 52GRb 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: b-type RCBO (50AF expansion, fully electronic) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Fully Electronic + RCD | Trip curve: Fully electronic | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KS 4613 / — | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO ABE100Fb family. | Application: Industrial distribution panel (MCB). | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO ABE100Fb family. | Application: Industrial distribution panel (MCB). | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ABE102Fb/60 | ABE Fb ABE100Fb — ABE102Fb 60A 2P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 60A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | |
| ABE102Fb/75 | ABE Fb ABE100Fb — ABE102Fb 75A 2P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 75A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | |
| ABE102Fb/100 | ABE Fb ABE100Fb — ABE102Fb 100A 2P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 100A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | |
| ABE103Fb/60 | ABE Fb ABE100Fb — ABE103Fb 60A 3P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 60A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | |
| ABE103Fb/75 | ABE Fb ABE100Fb — ABE103Fb 75A 3P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 75A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | |
| ABE103Fb/100 | ABE Fb ABE100Fb — ABE103Fb 100A 3P (MCB) | LS ELECTRIC | Frame: 100AF | Type: E-type Hydraulic-Magnetic (Economy) | Rated current (In): 100A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 460V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic | Trip curve: (7~15)×In | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/460V | Standard: KSC 8321 / IEC 60947-2 | Application: Industrial distribution panel (MCB) |