Proportional Power Saving
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 125 L/min (1β125 L/min). Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 125 L/min (1β125 L/min). Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-03-125-C-61 | EFBG-03 Power-Saving (E), 125L/min, pilot relief C, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.4β15.7 MPa), rated current 890 mA | Pilot: Internal pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-03-125-C-E-61 | EFBG-03 Power-Saving (E), 125L/min, pilot relief C, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.4β15.7 MPa), rated current 890 mA | Pilot: External pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-03-125-H-61 | EFBG-03 Power-Saving (E), 125L/min, pilot relief H, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.4β24.5 MPa), rated current 930 mA | Pilot: Internal pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-03-125-H-E-61 | EFBG-03 Power-Saving (E), 125L/min, pilot relief H, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.4β24.5 MPa), rated current 930 mA | Pilot: External pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-03-125-61 | EFBG-03 Power-Saving (E), 125L/min, no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-03-125-E-61 | EFBG-03 Power-Saving (E), 125L/min, no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 800 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min (2.5β250 L/min). Pilot-relief pressure range C: 1.6β15.7 MPa / H: 1.8β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min (2.5β250 L/min). Pilot-relief pressure range C: 1.6β15.7 MPa / H: 1.8β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-03-250-C-51 | EFBG-03-250 High-Flow Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.6β15.7 MPa), rated current 850 mA | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-03-250-C-E-51 | EFBG-03-250 High-Flow Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.6β15.7 MPa), rated current 850 mA | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-03-250-H-51 | EFBG-03-250 High-Flow Power-Saving (E), pilot relief H, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.8β24.5 MPa), rated current 870 mA | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-03-250-H-E-51 | EFBG-03-250 High-Flow Power-Saving (E), pilot relief H, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.8β24.5 MPa), rated current 870 mA | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-03-250-51 | EFBG-03-250 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-03-250-E-51 | EFBG-03-250 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 0.8 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 |
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min (2.5β250 L/min). Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min (2.5β250 L/min). Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-06-250-C-61 | EFBG-06 Power-Saving (E), 250L/min, pilot relief C, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.4β15.7 MPa), rated current 820 mA | Pilot: Internal pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-06-250-C-E-61 | EFBG-06 Power-Saving (E), 250L/min, pilot relief C, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.4β15.7 MPa), rated current 820 mA | Pilot: External pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-06-250-H-61 | EFBG-06 Power-Saving (E), 250L/min, pilot relief H, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.4β24.5 MPa), rated current 880 mA | Pilot: Internal pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-06-250-H-E-61 | EFBG-06 Power-Saving (E), 250L/min, pilot relief H, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.4β24.5 MPa), rated current 880 mA | Pilot: External pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-06-250-61 | EFBG-06 Power-Saving (E), 250L/min, no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 | |
| EFBG-06-250-E-61 | EFBG-06 Power-Saving (E), 250L/min, no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 750 mA | Valve Pressure Drop: 0.7 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 61 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min (5β500 L/min). Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min (5β500 L/min). Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-06-500-C-51 | EFBG-06-500 High-Flow Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.5β15.7 MPa), rated current 800 mA | Pilot: Internal pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-06-500-C-E-51 | EFBG-06-500 High-Flow Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.5β15.7 MPa), rated current 800 mA | Pilot: External pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-06-500-H-51 | EFBG-06-500 High-Flow Power-Saving (E), pilot relief H, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.5β24.5 MPa), rated current 900 mA | Pilot: Internal pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-06-500-H-E-51 | EFBG-06-500 High-Flow Power-Saving (E), pilot relief H, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.5β24.5 MPa), rated current 900 mA | Pilot: External pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-06-500-51 | EFBG-06-500 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-06-500-E-51 | EFBG-06-500 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 780 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 |
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min (5β500 L/min). Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
10Ξ©-10Ξ© Series Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator: it controls pump pressure with a very small differential against the load pressure, so power consumption is low; a temperature-compensated meter-in flow-adjusting valve giving stable flow control regardless of oil temperature. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min (5β500 L/min). Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-10-500-C-51 | EFBG-10 Power-Saving (E), 500L/min, pilot relief C, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.5β15.7 MPa), rated current 800 mA | Pilot: Internal pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-500-C-E-51 | EFBG-10 Power-Saving (E), 500L/min, pilot relief C, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.5β15.7 MPa), rated current 800 mA | Pilot: External pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-500-H-51 | EFBG-10 Power-Saving (E), 500L/min, pilot relief H, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.5β24.5 MPa), rated current 900 mA | Pilot: Internal pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-500-H-E-51 | EFBG-10 Power-Saving (E), 500L/min, pilot relief H, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.5β24.5 MPa), rated current 900 mA | Pilot: External pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-500-51 | EFBG-10 Power-Saving (E), 500L/min, no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-500-E-51 | EFBG-10 Power-Saving (E), 500L/min, no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief, E series, current-driven) | Series: EFBG (10Ξ©-10Ξ©) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 900 mA | Valve Pressure Drop: 0.9 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 1000 L/min (10β1000 L/min). Pilot-relief pressure range C: 1.1β15.7 MPa / H: 1.1β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the E-series EFBG power-saving valve, with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 1000 L/min (10β1000 L/min). Pilot-relief pressure range C: 1.1β15.7 MPa / H: 1.1β24.5 MPa; or no pilot relief valve (safety valve built-in). Internal/external pilot. Coil 10Ξ©, current-driven.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFBG-10-1000-C-51 | EFBG-10-1000 High-Flow Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.1β15.7 MPa), rated current 900 mA | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-1000-C-E-51 | EFBG-10-1000 High-Flow Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: C (1.1β15.7 MPa), rated current 900 mA | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-1000-H-51 | EFBG-10-1000 High-Flow Power-Saving (E), pilot relief H, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.1β24.5 MPa), rated current 950 mA | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-1000-H-E-51 | EFBG-10-1000 High-Flow Power-Saving (E), pilot relief H, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief Pressure: H (1.1β24.5 MPa), rated current 950 mA | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-1000-51 | EFBG-10-1000 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: Internal pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 | |
| EFBG-10-1000-E-51 | EFBG-10-1000 High-Flow Power-Saving (E), no pilot relief valve (safety valve built-in), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: EFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Flow Adj. Range: 10β1000 L/min | Max Pressure: 24.5 MPa | Pilot Relief: None (safety valve built-in), max adjustment pressure 24.5 MPa | Pilot: External pilot | Flow-control Rated Current: 830 mA | Valve Pressure Drop: 1.2 MPa | Coil: 10Ξ© | Drive: Current input (use with dedicated power amplifier) | Design No.: 51 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2β15.7 MPa / H: 1.4β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2β15.7 MPa / H: 1.4β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-60-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-E-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1β60 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-E-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range C (1.2β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6β15.7 MPa / H: 1.8β24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ξ©, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6β15.7 MPa / H: 1.8β24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ξ©, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-250-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-E-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.6β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.6β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.6β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.6β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.8β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.8β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.8β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.8β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4β15.7 MPa / H: 1.4β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-250-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-E-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.4β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.4β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.4β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range C (1.4β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5β250 L/min | Pilot Relief Pressure: Range H (1.4β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ξ©, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125β250, 06: 250β500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ξ©, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-500-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-E-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5β15.7 MPa / H: 1.5β24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ξ©, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-500-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-E-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range C (1.5β15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5β500 L/min | Pilot Relief Pressure: Range H (1.5β24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ξ©, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-1000 | EHFBG-10-1000 High-Flow Power-Saving, 1000 L/min, available by separate inquiry (RFQ) | Yuken | Type: High-Flow Proportional Power-Saving Valve | Series: EHFBG (High Flow) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Max Pressure: 24.5 MPa | Availability: Made to order β full options by separate inquiry (RFQ) |
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ξ©) while the pressure-control system is current-driven (coil 10Ξ©). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 125 L/min (1β125 L/min). Pilot-relief pressure range C: 1.6β16 MPa. Internal/external pilot. Hysteresis 0.5%.
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ξ©) while the pressure-control system is current-driven (coil 10Ξ©). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 125 L/min (1β125 L/min). Pilot-relief pressure range C: 1.6β16 MPa. Internal/external pilot. Hysteresis 0.5%.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELFBG-03-125-C-10 | ELFBG-03-125 High-Performance Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (1.6β16 MPa) | Pressure-control Rated Current: 890 mA | Pilot: Internal pilot | Flow-control: Voltage input DC10V, coil 4Ξ©, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ξ© | Valve Pressure Drop: 0.6β0.8 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 | |
| ELFBG-03-125-C-E-10 | ELFBG-03-125 High-Performance Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1β125 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (1.6β16 MPa) | Pressure-control Rated Current: 890 mA | Pilot: External pilot | Flow-control: Voltage input DC10V, coil 4Ξ©, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ξ© | Valve Pressure Drop: 0.6β0.8 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 |
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ξ©) while the pressure-control system is current-driven (coil 10Ξ©). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 170 L/min (1β170 L/min). Pilot-relief pressure range C: 2.3β18 MPa. Internal/external pilot. Hysteresis 0.5%.
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ξ©) while the pressure-control system is current-driven (coil 10Ξ©). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 170 L/min (1β170 L/min). Pilot-relief pressure range C: 2.3β18 MPa. Internal/external pilot. Hysteresis 0.5%.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELFBG-03-170-C-10 | ELFBG-03-170 High-Performance Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 170 L/min | Flow Adj. Range: 1β170 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (2.3β18 MPa) | Pressure-control Rated Current: 970 mA | Pilot: Internal pilot | Flow-control: Voltage input DC10V, coil 4Ξ©, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ξ© | Valve Pressure Drop: 0.85β1 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 | |
| ELFBG-03-170-C-E-10 | ELFBG-03-170 High-Performance Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 170 L/min | Flow Adj. Range: 1β170 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (2.3β18 MPa) | Pressure-control Rated Current: 970 mA | Pilot: External pilot | Flow-control: Voltage input DC10V, coil 4Ξ©, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ξ© | Valve Pressure Drop: 0.85β1 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 |