Proportional Setters & Controllers
Yuken multifunction slope controller that outputs arbitrary 2-channel analog voltage patterns and supports both slope-constant and time-constant ramping. The two channels can be used independently and can also serve as a setter for 04E-control variable piston pumps. Output channels 2 (A, B); output range 0β+5 V / 0βΒ±5 V / 0β+10 V / 0βΒ±10 V (DIP-selectable); slope shapes 4 (1 linear + 3 curves, DIP-selectable); max slope time 5/20/50/100 s; setting resolution 0.1% over 0βΒ±99.9%. Control modes: mode 1 (4-bit binary, 15 patterns) with stop mode, mode 2 (6-bit binary, 63 patterns), mode 3 (timer, 9 patterns Γ 4). Control input: current 10 mA/bit or voltage DC8β48 V photo-coupler isolated; output: transistor open collector max 30 V/50 mA. Settings stored in EEP-ROM (no battery). Common AC100/200V (85β260 V) 50/60 Hz, 10 VA, mass 1 kg.
Yuken multifunction slope controller that outputs arbitrary 2-channel analog voltage patterns and supports both slope-constant and time-constant ramping. The two channels can be used independently and can also serve as a setter for 04E-control variable piston pumps. Output channels 2 (A, B); output range 0β+5 V / 0βΒ±5 V / 0β+10 V / 0βΒ±10 V (DIP-selectable); slope shapes 4 (1 linear + 3 curves, DIP-selectable); max slope time 5/20/50/100 s; setting resolution 0.1% over 0βΒ±99.9%. Control modes: mode 1 (4-bit binary, 15 patterns) with stop mode, mode 2 (6-bit binary, 63 patterns), mode 3 (timer, 9 patterns Γ 4). Control input: current 10 mA/bit or voltage DC8β48 V photo-coupler isolated; output: transistor open collector max 30 V/50 mA. Settings stored in EEP-ROM (no battery). Common AC100/200V (85β260 V) 50/60 Hz, 10 VA, mass 1 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMC-T-20 | Yuken AMC-T-20 multifunction 2-channel slope controller | Yuken | Type: Multifunction slope controller | Brand: Yuken | Model: AMC-T-20 | Output Channels: 2 (A, B) | Output Voltage Range: 0β+5 / 0βΒ±5 / 0β+10 / 0βΒ±10 V (DIP) | Slope Mode: slope-constant or time-constant (DIP) | Slope Shapes: 4 (1 linear + 3 curves, DIP) | Max Slope Time: 5 / 20 / 50 / 100 s (DIP) | Setting Resolution: 0.1% over 0βΒ±99.9% | Control Modes: mode1 4-bit (15 patterns, stop mode) / mode2 6-bit (63 patterns) / mode3 timer (9Γ4) | Control Input: current 10 mA/bit or voltage DC8β48 V (photo-coupler isolated) | Control Output: transistor open collector max 30 V/50 mA | Data Storage: EEP-ROM (no battery) | Power Supply: AC100/200V common (85β260 V) 50/60 Hz | Power Consumption: 10 VA | Mass: 1 kg | Also usable as: setter for 04E-control variable piston pumps | Design No.: 20 |
Yuken compact, lightweight slope controller β about 1/5 the weight and 1/4 the volume of the earlier slope controller, with one-touch (plug-in) wiring. A 4-bit switching signal selects arbitrary level and acceleration/deceleration-time output patterns. Output channels 1; output voltage range 0β+5 V (factory), 0β+10 V, Β±5 V, Β±10 V; max slope time 1β9999 s (slope-constant or time-constant, 1 s steps); slope shapes 1 linear + 3 curves; setting resolution 0.1% over 0βΒ±99.9%; 4-bit binary input giving 15 output patterns. Sequence input 10 mA/24 V (10β28 V range), sequence output 50 mA / 32 V. Supply DC24V (20β30 V incl. ripple), 3 W, mass 0.2 kg.
Yuken compact, lightweight slope controller β about 1/5 the weight and 1/4 the volume of the earlier slope controller, with one-touch (plug-in) wiring. A 4-bit switching signal selects arbitrary level and acceleration/deceleration-time output patterns. Output channels 1; output voltage range 0β+5 V (factory), 0β+10 V, Β±5 V, Β±10 V; max slope time 1β9999 s (slope-constant or time-constant, 1 s steps); slope shapes 1 linear + 3 curves; setting resolution 0.1% over 0βΒ±99.9%; 4-bit binary input giving 15 output patterns. Sequence input 10 mA/24 V (10β28 V range), sequence output 50 mA / 32 V. Supply DC24V (20β30 V incl. ripple), 3 W, mass 0.2 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-T-10 | Yuken AMN-T-10 compact 1-channel slope controller | Yuken | Type: Compact slope controller | Brand: Yuken | Model: AMN-T-10 | Output Channels: 1 | Output Voltage Range: 0β+5 / 0β+10 / Β±5 / Β±10 V | Max Slope Time: 1β9999 s (slope- or time-constant, 1 s steps) | Slope Shapes: 1 linear + 3 curves | Setting Resolution: 0.1% over 0βΒ±99.9% | Output Patterns: 4-bit binary input β 15 patterns | Sequence Input: 10 mA/24 V (10β28 V range) | Sequence Output: 50 mA / 32 V max | Power Supply: DC24V (20β30 V incl. ripple) | Power Consumption: 3 W | Mass: 0.2 kg | Features: 1/5 weight & 1/4 volume vs previous, one-touch wiring | Design No.: 10 |
Yuken setting adjusters that supply the command-signal voltage to proportional-control power amplifiers. As setting depends on the actual operating method, setters are normally built to customer request; the following are sold as standard products. MC-01 is the simplest manual dial setter (single 1 kΞ© volume); MC-02 is a centre-tapped manual dial setter (1 kΩ·1 kΞ©) suited to servo systems; AMC-V6 is a 6-point setter for individual setting of six points. Use the setter potentiometer impedance specified for each amplifier (typically 1β2 kΞ©).
Yuken setting adjusters that supply the command-signal voltage to proportional-control power amplifiers. As setting depends on the actual operating method, setters are normally built to customer request; the following are sold as standard products. MC-01 is the simplest manual dial setter (single 1 kΞ© volume); MC-02 is a centre-tapped manual dial setter (1 kΩ·1 kΞ©) suited to servo systems; AMC-V6 is a 6-point setter for individual setting of six points. Use the setter potentiometer impedance specified for each amplifier (typically 1β2 kΞ©).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MC-01 | Yuken MC-01 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: MC-01 | Description: Manual dial setting adjuster with a single 1 kΞ© volume, dial and scale; the simplest setter. Panel-mount, mass 0.5 kg. | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier | |
| MC-02 | Yuken MC-02 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: MC-02 | Description: Manual dial setting adjuster with a centre-tapped volume (1 kΞ© Β· 1 kΞ©), dial and scale; suited to servo systems. | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier | |
| AMC-V6-S-10 | Yuken AMC-V6-S-10 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: AMC-V6-S-10 | Description: 6-point setter with six volumes, allowing individual setting of six points. Full order code AMC-V6-S-β»-10 (β» = option, specify by inquiry / RFQ). | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier |