Converter Units
FR-HC2 high power factor converter, 3-phase 200V, 7.5-75kW. Harmonic suppression (equivalent-capacity conversion coefficient K5=0), standard power regeneration (100% continuous / 150% 60s), input power factor 0.99+, up to 10 inverters connectable.
FR-HC2 high power factor converter, 3-phase 200V, 7.5-75kW. Harmonic suppression (equivalent-capacity conversion coefficient K5=0), standard power regeneration (100% continuous / 150% 60s), input power factor 0.99+, up to 10 inverters connectable.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-HC2-7.5K | FR-HC2 high power factor converter 7.5kW, 200V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 7.5 kW Β· Rated DC Output Capacity: 10.7 kW Β· Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz Β· Rated Input Current: 33 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 14 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Closed IP20 Β· Cooling: Forced-air Β· Mass (converter): 7 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-7.5K), Reactor 2 (FR-HCL22-7.5K), Outside Box (FR-HCB2-7.5K) | |
| FR-HC2-15K | FR-HC2 high power factor converter 15kW, 200V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 15 kW Β· Rated DC Output Capacity: 19.8 kW Β· Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz Β· Rated Input Current: 61 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 25 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Closed IP20 Β· Cooling: Forced-air Β· Mass (converter): 12 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-15K), Reactor 2 (FR-HCL22-15K), Outside Box (FR-HCB2-15K) | |
| FR-HC2-30K | FR-HC2 high power factor converter 30kW, 200V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 30 kW Β· Rated DC Output Capacity: 38 kW Β· Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz Β· Rated Input Current: 115 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 47 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 24 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-30K), Reactor 2 (FR-HCL22-30K), Outside Box (FR-HCB2-30K) | |
| FR-HC2-55K | FR-HC2 high power factor converter 55kW, 200V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 55 kW Β· Rated DC Output Capacity: 71 kW Β· Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz Β· Rated Input Current: 215 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 170-242V 50Hz / 170-253V 60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 88 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 39 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-55K), Reactor 2 (FR-HCL22-55K), Outside Box (FR-HCB2-55K) | |
| FR-HC2-75K | FR-HC2 high power factor converter 75kW, 200V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 75 kW Β· Rated DC Output Capacity: 92 kW Β· Rated Input Voltage: 3-ph 200-220V 50Hz / 200-230V 60Hz Β· Rated Input Current: 278 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 170-230V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 110 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 53 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-75K), Reactor 2 (FR-HCL22-75K), Outside Box (FR-HCB2-75K) |
FR-HC2 high power factor converter, 3-phase 400V, 7.5-560kW. Harmonic suppression (equivalent-capacity conversion coefficient K5=0), standard power regeneration (100% continuous / 150% 60s), input power factor 0.99+, up to 10 inverters connectable.
FR-HC2 high power factor converter, 3-phase 400V, 7.5-560kW. Harmonic suppression (equivalent-capacity conversion coefficient K5=0), standard power regeneration (100% continuous / 150% 60s), input power factor 0.99+, up to 10 inverters connectable.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-HC2-H7.5K | FR-HC2 high power factor converter 7.5kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 7.5 kW Β· Rated DC Output Capacity: 11.0 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 17 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-506V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 14 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Closed IP20 Β· Cooling: Forced-air Β· Mass (converter): 9 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H7.5K), Reactor 2 (FR-HCL22-H7.5K), Outside Box (FR-HCB2-H7.5K) | |
| FR-HC2-H15K | FR-HC2 high power factor converter 15kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 15 kW Β· Rated DC Output Capacity: 20.2 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 31 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-506V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 26 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Closed IP20 Β· Cooling: Forced-air Β· Mass (converter): 9 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H15K), Reactor 2 (FR-HCL22-H15K), Outside Box (FR-HCB2-H15K) | |
| FR-HC2-H30K | FR-HC2 high power factor converter 30kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 30 kW Β· Rated DC Output Capacity: 37 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 57 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-506V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 47 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 26 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H30K), Reactor 2 (FR-HCL22-H30K), Outside Box (FR-HCB2-H30K) | |
| FR-HC2-H55K | FR-HC2 high power factor converter 55kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 55 kW Β· Rated DC Output Capacity: 73 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 110 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-506V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 90 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 43 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H55K), Reactor 2 (FR-HCL22-H55K), Outside Box (FR-HCB2-H55K) | |
| FR-HC2-H75K | FR-HC2 high power factor converter 75kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 75 kW Β· Rated DC Output Capacity: 92 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 139 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 113 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 37 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H75K), Reactor 2 (FR-HCL22-H75K), Outside Box (FR-HCB2-H75K) | |
| FR-HC2-H110K | FR-HC2 high power factor converter 110kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 110 kW Β· Rated DC Output Capacity: 135 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 203 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 165 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 56 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H110K), Reactor 2 (FR-HCL22-H110K), Outside Box (FR-HCB2-H110K) | |
| FR-HC2-H160K | FR-HC2 high power factor converter 160kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 160 kW Β· Rated DC Output Capacity: 192 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 290 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 235 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 120 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H160K), Reactor 2 (FR-HCL22-H160K), Outside Box (FR-HCB2-H160K) | |
| FR-HC2-H220K | FR-HC2 high power factor converter 220kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 220 kW Β· Rated DC Output Capacity: 264 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 397 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 322 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 120 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H220K), Reactor 2 (FR-HCL22-H220K), Outside Box (FR-HCB2-H220K) | |
| FR-HC2-H280K | FR-HC2 high power factor converter 280kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 280 kW Β· Rated DC Output Capacity: 336 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 506 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 410 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 160 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H280K), Reactor 2 (FR-HCL22-H280K), Filter Capacitor (FR-HCC2-H280K), Inrush Resistor (FR-HCR2-H280K), MC Kit (FR-HCM2-H280K) | |
| FR-HC2-H400K | FR-HC2 high power factor converter 400kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 400 kW Β· Rated DC Output Capacity: 476 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 716 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 580 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 250 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H400K), Reactor 2 (FR-HCL22-H400K), Filter Capacitor (FR-HCC2-H400K), Inrush Resistor (FR-HCR2-H400K), MC Kit (FR-HCM2-H400K) | |
| FR-HC2-H560K | FR-HC2 high power factor converter 560kW, 400V class, harmonic suppression + power regeneration | MITSUBISHI ELECTRIC | Applicable Inverter Capacity: 560 kW Β· Rated DC Output Capacity: 660 kW Β· Rated Input Voltage: 3-ph 380-460V 50/60Hz Β· Rated Input Current: 993 A Β· Overload: 150% 60s Β· Permissible Voltage Fluctuation: 323-460V 50/60Hz Β· Frequency Fluctuation: +/-5% Β· Input Power Factor: 0.99 or more (at 100% load) Β· Power Supply Capacity: 804 kVA Β· Power Regeneration: 100% torque continuous / 150% torque 60s max Β· Harmonic Suppression: equivalent-capacity conversion coefficient K5=0 Β· Multi-inverter: up to 10 units connectable Β· Enclosure: Open IP00 Β· Cooling: Forced-air Β· Mass (converter): 250 kg Β· Included Peripherals: Reactor 1 (FR-HCL21-H560K), Reactor 2 (FR-HCL22-H560K), Filter Capacitor (FR-HCC2-H560K), Inrush Resistor (FR-HCR2-H560K), MC Kit (FR-HCM2-H560K) |
[MITSUBISHI ELECTRIC] β FREQROL FR-CC2-H Converter Unit (400V, 315-630kW, for FR-A842 inverter)
βΆMitsubishi FREQROL FR-CC2-H converter unit for the FR-A842 separate-converter inverter, three-phase 400V, 315-630kW. DC 430-780V bus output, built-in DC reactor, IP00, forced-air cooling.
Mitsubishi FREQROL FR-CC2-H converter unit for the FR-A842 separate-converter inverter, three-phase 400V, 315-630kW. DC 430-780V bus output, built-in DC reactor, IP00, forced-air cooling.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-CC2-H315K | FR-CC2-H315K converter unit, 315kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 315 kW Β· Overload Rating: 200% 60s / 250% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 610 A Β· Power Supply Capacity: 465 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 210 kg | |
| FR-CC2-H355K | FR-CC2-H355K converter unit, 355kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 355 kW Β· Overload Rating: 200% 60s / 250% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 683 A Β· Power Supply Capacity: 521 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 213 kg | |
| FR-CC2-H400K | FR-CC2-H400K converter unit, 400kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 400 kW Β· Overload Rating: 200% 60s / 250% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 770 A Β· Power Supply Capacity: 587 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 282 kg | |
| FR-CC2-H450K | FR-CC2-H450K converter unit, 450kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 450 kW Β· Overload Rating: 200% 60s / 250% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 866 A Β· Power Supply Capacity: 660 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 285 kg | |
| FR-CC2-H500K | FR-CC2-H500K converter unit, 500kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 500 kW Β· Overload Rating: 150% 60s / 200% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 962 A Β· Power Supply Capacity: 733 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 288 kg | |
| FR-CC2-H560K | FR-CC2-H560K converter unit, 560kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 560 kW Β· Overload Rating: 120% 60s / 150% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 1094 A Β· Power Supply Capacity: 833 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 293 kg | |
| FR-CC2-H630K | FR-CC2-H630K converter unit, 630kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) Β· Applied Motor: 630 kW Β· Overload Rating: 110% 60s / 120% 3s Β· DC Output Voltage: DC 430-780V Β· Rated Input Current: 1212 A Β· Power Supply Capacity: 924 kVA Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) Β· Weight: 294 kg |
Mitsubishi FREQROL FR-CC2-H-P parallel converter unit for FR-A842-P parallel-operation inverters, three-phase 400V, used in 2-unit or 3-unit parallel up to 1350kW. DC 430-780V output, built-in DC reactor, IP00.
Mitsubishi FREQROL FR-CC2-H-P parallel converter unit for FR-A842-P parallel-operation inverters, three-phase 400V, used in 2-unit or 3-unit parallel up to 1350kW. DC 430-780V output, built-in DC reactor, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-CC2-H400K-P | FR-CC2-H400K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) Β· Base Unit: FR-CC2-H400K-P Β· 2-unit Parallel Motor: 630 kW Β· 3-unit Parallel Motor: 945 kW Β· 2-unit Input Current: 1232 A Β· 3-unit Input Current: 1848 A Β· 2-unit Power Supply Capacity: 939 kVA Β· 3-unit Power Supply Capacity: 1409 kVA Β· Overload Rating: 150% 60s / 200% 3s Β· DC Output Voltage: DC 430-780V Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) | |
| FR-CC2-H450K-P | FR-CC2-H450K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) Β· Base Unit: FR-CC2-H450K-P Β· 2-unit Parallel Motor: 710 kW Β· 3-unit Parallel Motor: 1065 kW Β· 2-unit Input Current: 1386 A Β· 3-unit Input Current: 2078 A Β· 2-unit Power Supply Capacity: 1056 kVA Β· 3-unit Power Supply Capacity: 1584 kVA Β· Overload Rating: 150% 60s / 200% 3s Β· DC Output Voltage: DC 430-780V Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) | |
| FR-CC2-H500K-P | FR-CC2-H500K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) Β· Base Unit: FR-CC2-H500K-P Β· 2-unit Parallel Motor: 800 kW Β· 3-unit Parallel Motor: 1200 kW Β· 2-unit Input Current: 1539 A Β· 3-unit Input Current: 2309 A Β· 2-unit Power Supply Capacity: 1173 kVA Β· 3-unit Power Supply Capacity: 1759 kVA Β· Overload Rating: 150% 60s / 200% 3s Β· DC Output Voltage: DC 430-780V Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) | |
| FR-CC2-H560K-P | FR-CC2-H560K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) Β· Base Unit: FR-CC2-H560K-P Β· 2-unit Parallel Motor: 900 kW Β· 3-unit Parallel Motor: 1350 kW Β· 2-unit Input Current: 1750 A Β· 3-unit Input Current: 2626 A Β· 2-unit Power Supply Capacity: 1334 kVA Β· 3-unit Power Supply Capacity: 2002 kVA Β· Overload Rating: 150% 60s / 200% 3s Β· DC Output Voltage: DC 430-780V Β· Input: 3-phase 380-500V 50/60Hz Β· DC Reactor: Built-in Β· Cooling: Forced-air cooling Β· Protection: IP00 (open chassis) |