Magnetic Starters
Mitsubishi Electric MS-T/N series N125-frame reversing enclosed-type magnetic starter MS-2xN125: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N125-frame reversing enclosed-type magnetic starter MS-2xN125: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN125 42A AC24V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC48V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC100V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC200V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC300V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC400V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 42A AC500V | MS-2xN125 enclosed reversing starter, N125 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC24V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC48V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC100V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC200V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC300V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC400V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 54A AC500V | MS-2xN125 enclosed reversing starter, N125 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC24V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC48V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC100V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC200V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC300V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC400V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 67A AC500V | MS-2xN125 enclosed reversing starter, N125 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC24V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC48V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC100V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC200V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC300V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC400V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 82A AC500V | MS-2xN125 enclosed reversing starter, N125 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC24V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC48V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC100V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC200V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC300V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC400V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN125 105A AC500V | MS-2xN125 enclosed reversing starter, N125 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N150-frame reversing enclosed-type magnetic starter MS-2xN150: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N150-frame reversing enclosed-type magnetic starter MS-2xN150: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN150 42A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 42A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 54A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 67A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 82A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 105A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC24V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC48V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC100V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC200V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC300V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC400V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN150 125A AC500V | MS-2xN150 enclosed reversing starter, N150 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N180-frame reversing enclosed-type magnetic starter MS-2xN180: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 45kW / 180A (AC-3) at 200-220V and 90kW / 180A at 380-440V, Ith 260A. Heater designations 82A to 150A (4 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N180-frame reversing enclosed-type magnetic starter MS-2xN180: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 45kW / 180A (AC-3) at 200-220V and 90kW / 180A at 380-440V, Ith 260A. Heater designations 82A to 150A (4 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN180 82A AC48V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 82A AC100V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 82A AC200V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 82A AC300V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 82A AC400V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 82A AC500V | MS-2xN180 enclosed reversing starter, N180 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC48V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC100V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC200V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC300V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC400V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 105A AC500V | MS-2xN180 enclosed reversing starter, N180 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC48V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC100V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC200V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC300V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC400V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 125A AC500V | MS-2xN180 enclosed reversing starter, N180 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC48V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC100V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC200V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC300V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC400V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN180 150A AC500V | MS-2xN180 enclosed reversing starter, N180 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N220-frame reversing enclosed-type magnetic starter MS-2xN220: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N220-frame reversing enclosed-type magnetic starter MS-2xN220: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN220 82A AC48V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 82A AC100V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 82A AC200V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 82A AC300V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 82A AC400V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 82A AC500V | MS-2xN220 enclosed reversing starter, N220 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC48V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC100V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC200V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC300V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC400V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 105A AC500V | MS-2xN220 enclosed reversing starter, N220 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC48V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC100V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC200V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC300V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC400V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 125A AC500V | MS-2xN220 enclosed reversing starter, N220 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC48V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC100V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC200V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC300V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC400V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 150A AC500V | MS-2xN220 enclosed reversing starter, N220 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC48V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC100V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC200V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC300V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC400V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN220 180A AC500V | MS-2xN220 enclosed reversing starter, N220 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N300-frame reversing enclosed-type magnetic starter MS-2xN300: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N300-frame reversing enclosed-type magnetic starter MS-2xN300: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN300 105A AC48V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 105A AC100V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 105A AC200V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 105A AC300V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 105A AC400V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 105A AC500V | MS-2xN300 enclosed reversing starter, N300 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC48V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC100V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC200V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC300V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC400V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 125A AC500V | MS-2xN300 enclosed reversing starter, N300 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC48V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC100V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC200V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC300V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC400V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 150A AC500V | MS-2xN300 enclosed reversing starter, N300 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC48V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC100V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC200V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC300V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC400V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 180A AC500V | MS-2xN300 enclosed reversing starter, N300 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC48V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC100V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC200V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC300V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC400V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN300 250A AC500V | MS-2xN300 enclosed reversing starter, N300 frame, 250A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N400-frame reversing enclosed-type magnetic starter MS-2xN400: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N400-frame reversing enclosed-type magnetic starter MS-2xN400: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xN400 105A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 105A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 105A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 105A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 105A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 105A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 125A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 150A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 180A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 250A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 250A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC48V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC100V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC200V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC300V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC400V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xN400 330A AC500V | MS-2xN400 enclosed reversing starter, N400 frame, 330A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T100-frame reversing enclosed-type magnetic starter MS-2xT100: AC-operated contactor with TH-T65/T100 2-element thermal overload relay housed in a protective enclosure. Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T100-frame reversing enclosed-type magnetic starter MS-2xT100: AC-operated contactor with TH-T65/T100 2-element thermal overload relay housed in a protective enclosure. Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT100 15A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 15A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 22A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 29A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 35A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 42A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 54A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 67A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC24V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC48V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC100V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC200V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC300V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC400V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT100 82A AC500V | MS-2xT100 enclosed reversing starter, T100 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T21-frame reversing enclosed-type magnetic starter MS-2xT21: AC-operated contactor with TH-T25 2-element thermal overload relay housed in a protective enclosure. Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T21-frame reversing enclosed-type magnetic starter MS-2xT21: AC-operated contactor with TH-T25 2-element thermal overload relay housed in a protective enclosure. Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT21 0.24A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.24A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.35A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.5A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.7A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 0.9A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.3A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 1.7A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.1A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 2.5A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 3.6A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 5A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 6.6A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 9A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 11A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC24V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC48V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC100V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC200V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC300V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC400V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT21 15A AC500V | MS-2xT21 enclosed reversing starter, T21 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T35-frame reversing enclosed-type magnetic starter MS-2xT35: AC-operated contactor with TH-T25/T50 2-element thermal overload relay housed in a protective enclosure. Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T35-frame reversing enclosed-type magnetic starter MS-2xT35: AC-operated contactor with TH-T25/T50 2-element thermal overload relay housed in a protective enclosure. Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT35 0.24A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.24A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.35A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.5A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.7A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 0.9A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.3A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 1.7A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.1A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 2.5A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 3.6A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 5A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 6.6A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 9A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 11A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 15A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 22A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC24V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC48V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC100V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC200V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC300V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC400V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT35 29A AC500V | MS-2xT35 enclosed reversing starter, T35 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T50-frame reversing enclosed-type magnetic starter MS-2xT50: AC-operated contactor with TH-T25/T50 2-element thermal overload relay housed in a protective enclosure. Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T50-frame reversing enclosed-type magnetic starter MS-2xT50: AC-operated contactor with TH-T25/T50 2-element thermal overload relay housed in a protective enclosure. Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT50 0.24A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.24A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.35A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.5A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.7A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 0.9A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.3A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 1.7A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.1A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 2.5A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 3.6A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 5A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 6.6A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 9A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 11A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 15A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 22A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 29A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 35A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC24V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC48V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC100V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC200V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC300V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC400V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT50 42A AC500V | MS-2xT50 enclosed reversing starter, T50 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T65-frame reversing enclosed-type magnetic starter MS-2xT65: AC-operated contactor with TH-T65 2-element thermal overload relay housed in a protective enclosure. Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T65-frame reversing enclosed-type magnetic starter MS-2xT65: AC-operated contactor with TH-T65 2-element thermal overload relay housed in a protective enclosure. Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT65 15A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 15A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 22A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 29A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 35A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 42A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC24V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC48V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC100V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC200V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC300V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC400V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT65 54A AC500V | MS-2xT65 enclosed reversing starter, T65 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T80-frame reversing enclosed-type magnetic starter MS-2xT80: AC-operated contactor with TH-T100 2-element thermal overload relay housed in a protective enclosure. Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series T80-frame reversing enclosed-type magnetic starter MS-2xT80: AC-operated contactor with TH-T100 2-element thermal overload relay housed in a protective enclosure. Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-2xT80 67A AC24V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC48V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC100V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC200V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC300V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC400V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-2xT80 67A AC500V | MS-2xT80 enclosed reversing starter, T80 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (enclosed-type dedicated 67A) (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N125-frame non-reversing enclosed-type magnetic starter MS-N125: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N125-frame non-reversing enclosed-type magnetic starter MS-N125: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N125 42A AC24V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC48V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC100V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC200V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC300V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC400V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 42A AC500V | MS-N125 enclosed non-reversing starter, N125 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC24V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC48V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC100V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC200V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC300V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC400V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 54A AC500V | MS-N125 enclosed non-reversing starter, N125 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC24V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC48V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC100V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC200V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC300V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC400V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 67A AC500V | MS-N125 enclosed non-reversing starter, N125 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC24V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC48V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC100V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC200V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC300V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC400V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 82A AC500V | MS-N125 enclosed non-reversing starter, N125 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC24V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC48V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC100V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC200V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC300V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC400V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N125 105A AC500V | MS-N125 enclosed non-reversing starter, N125 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N150-frame non-reversing enclosed-type magnetic starter MS-N150: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N150-frame non-reversing enclosed-type magnetic starter MS-N150: AC-operated contactor with TH-N120(TA) 2-element thermal overload relay housed in a protective enclosure. Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N150 42A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 42A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 54A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 67A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 82A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 105A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC24V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC48V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC100V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC200V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC300V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC400V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N150 125A AC500V | MS-N150 enclosed non-reversing starter, N150 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N180-frame non-reversing enclosed-type magnetic starter MS-N180: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 45kW / 180A (AC-3) at 200-220V and 90kW / 180A at 380-440V, Ith 260A. Heater designations 82A to 150A (4 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N180-frame non-reversing enclosed-type magnetic starter MS-N180: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 45kW / 180A (AC-3) at 200-220V and 90kW / 180A at 380-440V, Ith 260A. Heater designations 82A to 150A (4 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N180 82A AC48V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 82A AC100V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 82A AC200V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 82A AC300V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 82A AC400V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 82A AC500V | MS-N180 enclosed non-reversing starter, N180 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC48V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC100V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC200V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC300V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC400V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 105A AC500V | MS-N180 enclosed non-reversing starter, N180 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC48V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC100V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC200V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC300V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC400V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 125A AC500V | MS-N180 enclosed non-reversing starter, N180 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC48V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC100V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC200V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC300V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC400V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N180 150A AC500V | MS-N180 enclosed non-reversing starter, N180 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N180 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 45kW@200-220V / 90kW@380-440V / 110kW@500-550V · AC-3 Current: 180A@200-220V / 180A@380-440V / 180A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N220-frame non-reversing enclosed-type magnetic starter MS-N220: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N220-frame non-reversing enclosed-type magnetic starter MS-N220: AC-operated contactor with TH-N220RH 2-element thermal overload relay housed in a protective enclosure. Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N220 82A AC48V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 82A AC100V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 82A AC200V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 82A AC300V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 82A AC400V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 82A AC500V | MS-N220 enclosed non-reversing starter, N220 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC48V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC100V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC200V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC300V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC400V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 105A AC500V | MS-N220 enclosed non-reversing starter, N220 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC48V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC100V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC200V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC300V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC400V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 125A AC500V | MS-N220 enclosed non-reversing starter, N220 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC48V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC100V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC200V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC300V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC400V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 150A AC500V | MS-N220 enclosed non-reversing starter, N220 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC48V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC100V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC200V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC300V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC400V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N220 180A AC500V | MS-N220 enclosed non-reversing starter, N220 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N300-frame non-reversing enclosed-type magnetic starter MS-N300: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N300-frame non-reversing enclosed-type magnetic starter MS-N300: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N300 105A AC48V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 105A AC100V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 105A AC200V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 105A AC300V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 105A AC400V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 105A AC500V | MS-N300 enclosed non-reversing starter, N300 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC48V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC100V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC200V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC300V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC400V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 125A AC500V | MS-N300 enclosed non-reversing starter, N300 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC48V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC100V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC200V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC300V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC400V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 150A AC500V | MS-N300 enclosed non-reversing starter, N300 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC48V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC100V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC200V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC300V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC400V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 180A AC500V | MS-N300 enclosed non-reversing starter, N300 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC48V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC100V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC200V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC300V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC300V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC400V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC400V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N300 250A AC500V | MS-N300 enclosed non-reversing starter, N300 frame, 250A heater, AC500V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N400-frame non-reversing enclosed-type magnetic starter MS-N400: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series N400-frame non-reversing enclosed-type magnetic starter MS-N400: AC-operated contactor with TH-N400RH 2-element thermal overload relay housed in a protective enclosure. Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-N400 105A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 105A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 105A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 105A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 105A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 105A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 105A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 125A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 125A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 150A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 150A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 180A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 180A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 250A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 250A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC48V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC100V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC200V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC300V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC300V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC400V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC400V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-N400 330A AC500V | MS-N400 enclosed non-reversing starter, N400 frame, 330A heater, AC500V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T10-frame non-reversing enclosed-type magnetic starter MS-T10: AC-operated contactor with TH-T18 2-element thermal overload relay housed in a protective enclosure. Rated 2.2kW / 11A (AC-3) at 200-220V and 2.7kW / 7A at 380-440V, Ith 20A. Heater designations 0.12A to 9A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series T10-frame non-reversing enclosed-type magnetic starter MS-T10: AC-operated contactor with TH-T18 2-element thermal overload relay housed in a protective enclosure. Rated 2.2kW / 11A (AC-3) at 200-220V and 2.7kW / 7A at 380-440V, Ith 20A. Heater designations 0.12A to 9A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-T10 0.12A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.12A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.17A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.24A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.35A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.5A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.7A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 0.9A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.3A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 1.7A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.1A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 2.5A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 3.6A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 5A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 6.6A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC24V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC48V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC100V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC200V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC300V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC400V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T10 9A AC500V | MS-T10 enclosed non-reversing starter, T10 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T10 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.2kW@200-220V / 2.7kW@380-440V / 2.7kW@500-550V · AC-3 Current: 11A@200-220V / 7A@380-440V / 6A@500-550V · AC-1 Current: 20A@200-220V / 11A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T100-frame non-reversing enclosed-type magnetic starter MS-T100: AC-operated contactor with TH-T65/T100 2-element thermal overload relay housed in a protective enclosure. Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
Mitsubishi Electric MS-T/N series T100-frame non-reversing enclosed-type magnetic starter MS-T100: AC-operated contactor with TH-T65/T100 2-element thermal overload relay housed in a protective enclosure. Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Auxiliary contact option units cannot be added to enclosed types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MS-T100 15A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 15A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 22A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 29A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 35A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 42A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 54A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 67A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC24V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC48V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC100V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC200V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC300V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC300V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC400V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC400V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MS-T100 82A AC500V | MS-T100 enclosed non-reversing starter, T100 frame, 82A heater, AC500V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Enclosed Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |