Variable Frequency Drives
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0362. Maximum applicable motor: ND 185kW / HD 160kW. Rated output current: ND 362A / HD 304A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0362. Maximum applicable motor: ND 185kW / HD 160kW. Rated output current: ND 362A / HD 304A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0362 | A1000 400V class AC drive/inverter; ND 185kW / HD 160kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0362 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 185kW / HD 160kW · Rated Input Current: ND 346A / HD 300A · Rated Output Capacity: ND 276kVA / HD 232kVA · Rated Output Current: ND 362A / HD 304A · Power Supply Capacity: ND 316kVA / HD 274kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0414. Maximum applicable motor: ND 220kW / HD 185kW. Rated output current: ND 414A / HD 370A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0414. Maximum applicable motor: ND 220kW / HD 185kW. Rated output current: ND 414A / HD 370A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0414 | A1000 400V class AC drive/inverter; ND 220kW / HD 185kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0414 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 220kW / HD 185kW · Rated Input Current: ND 410A / HD 346A · Rated Output Capacity: ND 316kVA / HD 282kVA · Rated Output Current: ND 414A / HD 370A · Power Supply Capacity: ND 375kVA / HD 316kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0515. Maximum applicable motor: ND 250kW / HD 220kW. Rated output current: ND 515A / HD 450A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0515. Maximum applicable motor: ND 250kW / HD 220kW. Rated output current: ND 515A / HD 450A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0515 | A1000 400V class AC drive/inverter; ND 250kW / HD 220kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0515 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 250kW / HD 220kW · Rated Input Current: ND 465A / HD 410A · Rated Output Capacity: ND 392kVA / HD 343kVA · Rated Output Current: ND 515A / HD 450A · Power Supply Capacity: ND 425kVA / HD 375kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0675. Maximum applicable motor: ND 355kW / HD 315kW. Rated output current: ND 675A / HD 605A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0675. Maximum applicable motor: ND 355kW / HD 315kW. Rated output current: ND 675A / HD 605A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0675 | A1000 400V class AC drive/inverter; ND 355kW / HD 315kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0675 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 355kW / HD 315kW · Rated Input Current: ND 657A / HD 584A · Rated Output Capacity: ND 514kVA / HD 461kVA · Rated Output Current: ND 675A / HD 605A · Power Supply Capacity: ND 601kVA / HD 534kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 400 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0930. Maximum applicable motor: ND 500kW / HD 450kW. Rated output current: ND 930A / HD 810A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A0930. Maximum applicable motor: ND 500kW / HD 450kW. Rated output current: ND 930A / HD 810A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A0930 | A1000 400V class AC drive/inverter; ND 500kW / HD 450kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A0930 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 500kW / HD 450kW · Rated Input Current: ND 922A / HD 830A · Rated Output Capacity: ND 709kVA / HD 617kVA · Rated Output Current: ND 930A / HD 810A · Power Supply Capacity: ND 843kVA / HD 759kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 150 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A1200. Maximum applicable motor: ND 630kW / HD 560kW. Rated output current: ND 1200A / HD 1090A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
Yaskawa A1000 400V class AC drive/inverter, model CIMR-AT4A1200. Maximum applicable motor: ND 630kW / HD 560kW. Rated output current: ND 1200A / HD 1090A. Designed for variable-speed motor control with selectable Normal Duty (ND) and Heavy Duty (HD) ratings.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| CIMR-AT4A1200 | A1000 400V class AC drive/inverter; ND 630kW / HD 560kW | YASKAWA | Series: A1000 · Model: CIMR-AT4A1200 · Voltage Class: 400V · Rated Supply: 3-phase 380–480 V AC, 50/60 Hz · DC Supply: 510–680 V DC · Maximum Applicable Motor: ND 630kW / HD 560kW · Rated Input Current: ND 1158A / HD 1031A · Rated Output Capacity: ND 915kVA / HD 831kVA · Rated Output Current: ND 1200A / HD 1090A · Power Supply Capacity: ND 1059kVA / HD 943kVA · Overload Capacity: ND 120% for 60s / HD 150% for 60s · Maximum Output Frequency: 150 Hz · Frequency Control Range: 0.01–400Hz · Control: V/f, vector and PM motor control modes · Communication: MEMOBUS RS-485/422 up to 115.2kbps · Safety Standards: UL508C, EN61800-3, EN61800-5-1, ISO13849-1 Cat.3 PLd, IEC/EN61508 SIL2 |