PBPC Phase Bus Protective Cover — terminal protection cover required for installation of PB-series Phase Bus busbars. PBPC-32 covers all PB-32 variants (PB-322/323/324/325 + PBL-322/323). PBPC-63 covers PB-632/633. CE/UL certified.
PBPC Phase Bus Protective Cover — terminal protection cover required for installation of PB-series Phase Bus busbars. PBPC-32 covers all PB-32 variants (PB-322/323/324/325 + PBL-322/323). PBPC-63 covers PB-632/633. CE/UL certified.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PBPC-32 | Phase Bus Protective Cover for PB-32 series | LS ELECTRIC | Type: Phase Bus Protective Cover | Compatible: PB-322, PB-323, PB-324, PB-325, PBL-322, PBL-323 | Frame: 32AF | Function: Terminal protection cover for parallel busbar | Standards: CE, UL | |
| PBPC-63 | Phase Bus Protective Cover for PB-63 series | LS ELECTRIC | Type: Phase Bus Protective Cover | Compatible: PB-632, PB-633 | Frame: 63AF | Function: Terminal protection cover for parallel busbar | Standards: CE, UL |
RS Shunt Release for remote tripping of Metasol MMS. Right side-mount, single unit per MMS. Operating voltage range 0.7~1.1×Us. Available in 6 voltages: 24V, 110V, 220-230V, 240V, 380-400V, 415-440V (50/60Hz). Inrush 8.5VA/6W, holding 3VA/1.2W. CRITICAL: do not apply trip signal continuously for more than 10 seconds. Mutually exclusive with RU and RUX (only one right-side device permitted).
RS Shunt Release for remote tripping of Metasol MMS. Right side-mount, single unit per MMS. Operating voltage range 0.7~1.1×Us. Available in 6 voltages: 24V, 110V, 220-230V, 240V, 380-400V, 415-440V (50/60Hz). Inrush 8.5VA/6W, holding 3VA/1.2W. CRITICAL: do not apply trip signal continuously for more than 10 seconds. Mutually exclusive with RU and RUX (only one right-side device permitted).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| RS-AC24 | RS Shunt Release Trip, 24V 50Hz / 28V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 24V 50Hz / 28V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX | |
| RS-AC110 | RS Shunt Release Trip, 110V 50Hz / 120V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 110V 50Hz / 120V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX | |
| RS-AC220 | RS Shunt Release Trip, 220-230V 50Hz / 240-260V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 220-230V 50Hz / 240-260V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX | |
| RS-AC240 | RS Shunt Release Trip, 240V 50Hz / 277V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 240V 50Hz / 277V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX | |
| RS-AC380 | RS Shunt Release Trip, 380-400V 50Hz / 440-460V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 380-400V 50Hz / 440-460V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX | |
| RS-AC415 | RS Shunt Release Trip, 415-440V 50Hz / 460-480V 60Hz | LS ELECTRIC | Type: Shunt Release (RS) | Function: Trips MMS on signal (remote trip) | Mount: Right side-mount (single unit only) | Operating Voltage: 415-440V 50Hz / 460-480V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Operating Range: 0.7~1.1 × Us (pickup) | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Weight: 110g | Important: Do not apply trip signal for more than 10 seconds continuously | Mutual Exclusion: Cannot be installed simultaneously with RU or RUX |
RU Undervoltage Release — trips Metasol MMS when supply voltage drops below threshold. Pickup 0.85~1.1×Us, drop-out 0.7~0.35×Us. Right side-mount, single unit. 6 voltages available. Opening time 20ms. WARNING: if undervoltage persists, operating MMS may briefly energize main contacts; resolve undervoltage first. Mutually exclusive with RS and RUX.
RU Undervoltage Release — trips Metasol MMS when supply voltage drops below threshold. Pickup 0.85~1.1×Us, drop-out 0.7~0.35×Us. Right side-mount, single unit. 6 voltages available. Opening time 20ms. WARNING: if undervoltage persists, operating MMS may briefly energize main contacts; resolve undervoltage first. Mutually exclusive with RS and RUX.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| RU-AC24 | RU Undervoltage Release, 24V 50Hz / 28V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 24V 50Hz / 28V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. | |
| RU-AC110 | RU Undervoltage Release, 110V 50Hz / 120V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 110V 50Hz / 120V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. | |
| RU-AC220 | RU Undervoltage Release, 220-230V 50Hz / 240-260V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 220-230V 50Hz / 240-260V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. | |
| RU-AC240 | RU Undervoltage Release, 240V 50Hz / 277V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 240V 50Hz / 277V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. | |
| RU-AC380 | RU Undervoltage Release, 380-400V 50Hz / 440-460V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 380-400V 50Hz / 440-460V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. | |
| RU-AC415 | RU Undervoltage Release, 415-440V 50Hz / 460-480V 60Hz | LS ELECTRIC | Type: Undervoltage Release (RU) | Function: Trips MMS when supply voltage drops | Mount: Right side-mount (single unit only) | Operating Voltage: 415-440V 50Hz / 460-480V 60Hz | Compatible MMS: All Metasol MMS frames (32/63/100AF, S/H/HI) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 110g | Mutual Exclusion: Cannot be installed simultaneously with RS or RUX | Warning: If undervoltage condition persists, MMS may briefly energize main contacts when operated. Resolve undervoltage before operating MMS. |
RUX combines undervoltage release function with built-in alarm contact for remote signaling of undervoltage events. IMPORTANT: NOT compatible with MMS-32S — use with MMS-32H/HI or 63/100AF only. Pickup 0.85~1.1×Us, opening time 20ms. 6 voltages available. Right side-mount, single unit, mutually exclusive with RS and RU. After undervoltage trip, MMS handle must be moved to OFF position before re-energizing.
RUX combines undervoltage release function with built-in alarm contact for remote signaling of undervoltage events. IMPORTANT: NOT compatible with MMS-32S — use with MMS-32H/HI or 63/100AF only. Pickup 0.85~1.1×Us, opening time 20ms. 6 voltages available. Right side-mount, single unit, mutually exclusive with RS and RU. After undervoltage trip, MMS handle must be moved to OFF position before re-energizing.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| RUX-AC24 | RUX Undervoltage Release with Alarm Switch, 24V 50Hz / 28V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 24V 50Hz / 28V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU | |
| RUX-AC110 | RUX Undervoltage Release with Alarm Switch, 110V 50Hz / 120V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 110V 50Hz / 120V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU | |
| RUX-AC220 | RUX Undervoltage Release with Alarm Switch, 220-230V 50Hz / 240-260V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 220-230V 50Hz / 240-260V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU | |
| RUX-AC240 | RUX Undervoltage Release with Alarm Switch, 240V 50Hz / 277V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 240V 50Hz / 277V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU | |
| RUX-AC380 | RUX Undervoltage Release with Alarm Switch, 380-400V 50Hz / 440-460V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 380-400V 50Hz / 440-460V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU | |
| RUX-AC415 | RUX Undervoltage Release with Alarm Switch, 415-440V 50Hz / 460-480V 60Hz | LS ELECTRIC | Type: Undervoltage Release with Alarm Switch (RUX) | Function: Trips MMS on undervoltage AND provides alarm contact | Mount: Right side-mount (single unit only) | Operating Voltage: 415-440V 50Hz / 460-480V 60Hz | Compatible MMS: MMS-32H/HI, MMS-63S/H/HI, MMS-100S/H/HI | Incompatible MMS: MMS-32S (NOT supported) | Pickup Voltage: 0.85~1.1 × Us | Drop-out Voltage: 0.7~0.35 × Us | Inrush Power: 8.5VA / 6W | Holding Power: 3VA / 1.2W | Opening Time: 20ms | Weight: 120g | Alarm Contact: Built-in (D1-07 / D2-08 terminals) | Mutual Exclusion: Cannot be installed simultaneously with RS or RU |
MP-32 Screw Mounting Holder for MMS-32 series. Adapts MMS-32 (which is normally DIN-rail mounted) for direct panel mounting via M4 screws. Useful when DIN rail installation is not practical or when the panel layout calls for fixed-position mounting.
MP-32 Screw Mounting Holder for MMS-32 series. Adapts MMS-32 (which is normally DIN-rail mounted) for direct panel mounting via M4 screws. Useful when DIN rail installation is not practical or when the panel layout calls for fixed-position mounting.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MP-32 | Screw Mounting Holder for MMS-32 series | LS ELECTRIC | Type: Screw Mounting Holder | Compatible MMS: MMS-32S, MMS-32H, MMS-32HI | Function: Allows direct panel screw mounting (alternative to DIN rail) | Hardware: M4 screw |
TB-32 Terminal Block / Insulation Distance Extension. Extends phase-to-phase insulation distance on MMS-32H/32HI to satisfy UL Combination Motor Controller Type E requirements. Pair with MMS-32H/HI for UL 508 Type E compliant installations.
TB-32 Terminal Block / Insulation Distance Extension. Extends phase-to-phase insulation distance on MMS-32H/32HI to satisfy UL Combination Motor Controller Type E requirements. Pair with MMS-32H/HI for UL 508 Type E compliant installations.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TB-32 | Terminal Block / Insulation Distance Extension for MMS-32H/HI | LS ELECTRIC | Type: Terminal Block (Insulation Distance Extension) | Compatible MMS: MMS-32H, MMS-32HI | Function: Extends phase-to-phase insulation distance | Compliance: Required for UL Combination Motor Controller Type E rating |
Metasol MMS-100H Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100H Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100H/50A | Metasol MMS-100H 50A, Standard terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/50A O-RING TERMINAL | Metasol MMS-100H 50A, O-Ring Terminal terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/63A | Metasol MMS-100H 63A, Standard terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/63A O-RING TERMINAL | Metasol MMS-100H 63A, O-Ring Terminal terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/75A | Metasol MMS-100H 75A, Standard terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: 55~75A (±20% via dial) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/75A O-RING TERMINAL | Metasol MMS-100H 75A, O-Ring Terminal terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: 55~75A (±20% via dial) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/90A | Metasol MMS-100H 90A, Standard terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: 70~90A (±20% via dial) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/90A O-RING TERMINAL | Metasol MMS-100H 90A, O-Ring Terminal terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: 70~90A (±20% via dial) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/100A | Metasol MMS-100H 100A, Standard terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: 80~100A (±20% via dial) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/100A O-RING TERMINAL | Metasol MMS-100H 100A, O-Ring Terminal terminal, High Breaking (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: 80~100A (±20% via dial) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-100H Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100H Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100H/17A | Metasol MMS-100H 17A, Standard terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/17A O-RING TERMINAL | Metasol MMS-100H 17A, O-Ring Terminal terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/22A | Metasol MMS-100H 22A, Standard terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/22A O-RING TERMINAL | Metasol MMS-100H 22A, O-Ring Terminal terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/26A | Metasol MMS-100H 26A, Standard terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/26A O-RING TERMINAL | Metasol MMS-100H 26A, O-Ring Terminal terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/32A | Metasol MMS-100H 32A, Standard terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/32A O-RING TERMINAL | Metasol MMS-100H 32A, O-Ring Terminal terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/40A | Metasol MMS-100H 40A, Standard terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100H/40A O-RING TERMINAL | Metasol MMS-100H 40A, O-Ring Terminal terminal, High Breaking (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-100HI Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100HI Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100HI/50A | Metasol MMS-100HI 50A, Standard terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/50A O-RING TERMINAL | Metasol MMS-100HI 50A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/63A | Metasol MMS-100HI 63A, Standard terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/63A O-RING TERMINAL | Metasol MMS-100HI 63A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/75A | Metasol MMS-100HI 75A, Standard terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/75A O-RING TERMINAL | Metasol MMS-100HI 75A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/90A | Metasol MMS-100HI 90A, Standard terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/90A O-RING TERMINAL | Metasol MMS-100HI 90A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/100A | Metasol MMS-100HI 100A, Standard terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/100A O-RING TERMINAL | Metasol MMS-100HI 100A, O-Ring Terminal terminal, Instantaneous (MCP) (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-100HI Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100HI Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100HI/17A | Metasol MMS-100HI 17A, Standard terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/17A O-RING TERMINAL | Metasol MMS-100HI 17A, O-Ring Terminal terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/22A | Metasol MMS-100HI 22A, Standard terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/22A O-RING TERMINAL | Metasol MMS-100HI 22A, O-Ring Terminal terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/26A | Metasol MMS-100HI 26A, Standard terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/26A O-RING TERMINAL | Metasol MMS-100HI 26A, O-Ring Terminal terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/32A | Metasol MMS-100HI 32A, Standard terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/32A O-RING TERMINAL | Metasol MMS-100HI 32A, O-Ring Terminal terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/40A | Metasol MMS-100HI 40A, Standard terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100HI/40A O-RING TERMINAL | Metasol MMS-100HI 40A, O-Ring Terminal terminal, Instantaneous (MCP) (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-100S Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100S Manual Motor Starter — High Range (50~100A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. High range for motors 11~45kW (30kW @ 220V / 45kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100S/50A | Metasol MMS-100S 50A, Standard terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/50A O-RING TERMINAL | Metasol MMS-100S 50A, O-Ring Terminal terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 50A | Adjustment Range: 34~50A (±20% via dial) | Instantaneous Trip: 650A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/11kW · 400V/22kW · 690V/45kW · 230V/15HP · 460V/40HP · 575V/50HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/63A | Metasol MMS-100S 63A, Standard terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/63A O-RING TERMINAL | Metasol MMS-100S 63A, O-Ring Terminal terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 63A | Adjustment Range: 45~63A (±20% via dial) | Instantaneous Trip: 819A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/15kW · 400V/30kW · 690V/55kW · 230V/20HP · 460V/50HP · 575V/60HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/75A | Metasol MMS-100S 75A, Standard terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: 55~75A (±20% via dial) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/75A O-RING TERMINAL | Metasol MMS-100S 75A, O-Ring Terminal terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 75A | Adjustment Range: 55~75A (±20% via dial) | Instantaneous Trip: 975A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/22kW · 400V/37kW · 690V/63kW · 230V/25HP · 460V/60HP · 575V/75HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/90A | Metasol MMS-100S 90A, Standard terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: 70~90A (±20% via dial) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/90A O-RING TERMINAL | Metasol MMS-100S 90A, O-Ring Terminal terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 90A | Adjustment Range: 70~90A (±20% via dial) | Instantaneous Trip: 1170A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/75kW · 230V/30HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/100A | Metasol MMS-100S 100A, Standard terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: 80~100A (±20% via dial) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/100A O-RING TERMINAL | Metasol MMS-100S 100A, O-Ring Terminal terminal, Standard (High Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: High Range (50~100A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 100A | Adjustment Range: 80~100A (±20% via dial) | Instantaneous Trip: 1300A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/30kW · 400V/45kW · 690V/90kW · 230V/40HP · 460V/75HP · 575V/100HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-100S Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-100S Manual Motor Starter — Mid Range (17~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (100AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Mid range for motors 4~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 100AF, width 70mm. Rated insulation voltage Ui = 1000V, impulse Uimp = 8kV. Up to 690V Ue, 50/60Hz. Mechanical life 50,000 ops, electrical life 25,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-100S/17A | Metasol MMS-100S 17A, Standard terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/17A O-RING TERMINAL | Metasol MMS-100S 17A, O-Ring Terminal terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/22A | Metasol MMS-100S 22A, Standard terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/22A O-RING TERMINAL | Metasol MMS-100S 22A, O-Ring Terminal terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/26A | Metasol MMS-100S 26A, Standard terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/26A O-RING TERMINAL | Metasol MMS-100S 26A, O-Ring Terminal terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/10HP · 460V/20HP · 575V/25HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/32A | Metasol MMS-100S 32A, Standard terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/32A O-RING TERMINAL | Metasol MMS-100S 32A, O-Ring Terminal terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/25HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/40A | Metasol MMS-100S 40A, Standard terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-100S/40A O-RING TERMINAL | Metasol MMS-100S 40A, O-Ring Terminal terminal, Standard (Mid Range) | LS ELECTRIC | Frame: 100AF | Capacity Band: Mid Range (17~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 1000V | Impulse Uimp: 8kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 50,000 operations | Electrical Life: 25,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 70mm | Weight: ~2200g | Mounting: 35mm DIN rail / panel screw / 75mm DIN rail | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32H Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32H Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32H/1.6A | Metasol MMS-32H 1.6A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/1.6A O-RING TERMINAL | Metasol MMS-32H 1.6A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/2.5A | Metasol MMS-32H 2.5A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/2.5A O-RING TERMINAL | Metasol MMS-32H 2.5A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/4A | Metasol MMS-32H 4A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/4A O-RING TERMINAL | Metasol MMS-32H 4A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/6A | Metasol MMS-32H 6A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/6A O-RING TERMINAL | Metasol MMS-32H 6A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/8A | Metasol MMS-32H 8A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/8A O-RING TERMINAL | Metasol MMS-32H 8A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/10A | Metasol MMS-32H 10A, Standard terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/10A O-RING TERMINAL | Metasol MMS-32H 10A, O-Ring Terminal terminal, High Breaking (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32H Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32H Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32H/13A | Metasol MMS-32H 13A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/13A O-RING TERMINAL | Metasol MMS-32H 13A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/17A | Metasol MMS-32H 17A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/17A O-RING TERMINAL | Metasol MMS-32H 17A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/22A | Metasol MMS-32H 22A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/22A O-RING TERMINAL | Metasol MMS-32H 22A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/26A | Metasol MMS-32H 26A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/26A O-RING TERMINAL | Metasol MMS-32H 26A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/32A | Metasol MMS-32H 32A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/32A O-RING TERMINAL | Metasol MMS-32H 32A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/40A | Metasol MMS-32H 40A, Standard terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/40A O-RING TERMINAL | Metasol MMS-32H 40A, O-Ring Terminal terminal, High Breaking (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32H Manual Motor Starter — Sub-Amp (0.16~1A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Sub-amp range for control circuits, micro motors, instrumentation, and small valve actuators. Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32H Manual Motor Starter — Sub-Amp (0.16~1A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. High breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Trip-cause indicator on front. Sub-amp range for control circuits, micro motors, instrumentation, and small valve actuators. Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32H/0.16A | Metasol MMS-32H 0.16A, Standard terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: 0.1~0.16A (±20% via dial) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.16A O-RING TERMINAL | Metasol MMS-32H 0.16A, O-Ring Terminal terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: 0.1~0.16A (±20% via dial) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.25A | Metasol MMS-32H 0.25A, Standard terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: 0.16~0.25A (±20% via dial) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.25A O-RING TERMINAL | Metasol MMS-32H 0.25A, O-Ring Terminal terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: 0.16~0.25A (±20% via dial) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.4A | Metasol MMS-32H 0.4A, Standard terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: 0.25~0.4A (±20% via dial) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.4A O-RING TERMINAL | Metasol MMS-32H 0.4A, O-Ring Terminal terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: 0.25~0.4A (±20% via dial) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.63A | Metasol MMS-32H 0.63A, Standard terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: 0.4~0.63A (±20% via dial) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/0.63A O-RING TERMINAL | Metasol MMS-32H 0.63A, O-Ring Terminal terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: 0.4~0.63A (±20% via dial) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/1A | Metasol MMS-32H 1A, Standard terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: 0.63~1A (±20% via dial) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32H/1A O-RING TERMINAL | Metasol MMS-32H 1A, O-Ring Terminal terminal, High Breaking (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: High Breaking (H) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: 0.63~1A (±20% via dial) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32HI Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32HI Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32HI/1.6A | Metasol MMS-32HI 1.6A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/1.6A O-RING TERMINAL | Metasol MMS-32HI 1.6A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/2.5A | Metasol MMS-32HI 2.5A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/2.5A O-RING TERMINAL | Metasol MMS-32HI 2.5A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/4A | Metasol MMS-32HI 4A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/4A O-RING TERMINAL | Metasol MMS-32HI 4A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/6A | Metasol MMS-32HI 6A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/6A O-RING TERMINAL | Metasol MMS-32HI 6A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/8A | Metasol MMS-32HI 8A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/8A O-RING TERMINAL | Metasol MMS-32HI 8A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/10A | Metasol MMS-32HI 10A, Standard terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/10A O-RING TERMINAL | Metasol MMS-32HI 10A, O-Ring Terminal terminal, Instantaneous (MCP) (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32HI Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32HI Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32HI/13A | Metasol MMS-32HI 13A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/13A O-RING TERMINAL | Metasol MMS-32HI 13A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/17A | Metasol MMS-32HI 17A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/17A O-RING TERMINAL | Metasol MMS-32HI 17A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/22A | Metasol MMS-32HI 22A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/22A O-RING TERMINAL | Metasol MMS-32HI 22A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/26A | Metasol MMS-32HI 26A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/26A O-RING TERMINAL | Metasol MMS-32HI 26A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/32A | Metasol MMS-32HI 32A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/32A O-RING TERMINAL | Metasol MMS-32HI 32A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/40A | Metasol MMS-32HI 40A, Standard terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/40A O-RING TERMINAL | Metasol MMS-32HI 40A, O-Ring Terminal terminal, Instantaneous (MCP) (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32HI Manual Motor Starter — Sub-Amp (0.16~1A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Sub-amp range for control circuits, micro motors, instrumentation, and small valve actuators. Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32HI Manual Motor Starter — Sub-Amp (0.16~1A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Motor Circuit Protector — instantaneous magnetic trip only (no overload, no phase-loss). Pair with separate overload relay (e.g., MT-series TOR). Sub-amp range for control circuits, micro motors, instrumentation, and small valve actuators. Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508 Type E (Combination Motor Controller), K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32HI/0.16A | Metasol MMS-32HI 0.16A, Standard terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.16A O-RING TERMINAL | Metasol MMS-32HI 0.16A, O-Ring Terminal terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.16A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 2.1A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 400V/0.02kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.25A | Metasol MMS-32HI 0.25A, Standard terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.25A O-RING TERMINAL | Metasol MMS-32HI 0.25A, O-Ring Terminal terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.25A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 3.3A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.03kW · 400V/0.06kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.4A | Metasol MMS-32HI 0.4A, Standard terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.4A O-RING TERMINAL | Metasol MMS-32HI 0.4A, O-Ring Terminal terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.4A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 5.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.06kW · 400V/0.09kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.63A | Metasol MMS-32HI 0.63A, Standard terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/0.63A O-RING TERMINAL | Metasol MMS-32HI 0.63A, O-Ring Terminal terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 0.63A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 8.2A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.09kW · 400V/0.12kW · 690V/0.25kW | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/1A | Metasol MMS-32HI 1A, Standard terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32HI/1A O-RING TERMINAL | Metasol MMS-32HI 1A, O-Ring Terminal terminal, Instantaneous (MCP) (Sub-Amp) | LS ELECTRIC | Frame: 32AF | Capacity Band: Sub-Amp (0.16~1A) | Type: Instantaneous (MCP) (HI) | Pole: 3-Pole | Rated Current Ie: 1A | Adjustment Range: Fixed (instantaneous only, no thermal adjustment) | Instantaneous Trip: 13A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: None — pair with external TOR | Phase-Loss Protection: No | Handle: Rotary | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: Yes (Trip Indicator) | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~360g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.12kW · 400V/0.25kW · 690V/0.55kW · 460V/1/2HP · 575V/1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32S Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508, K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32S Manual Motor Starter — Low Range (1.6~10A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Low range for fractional-HP motors up to ~3kW (1.5kW @ 220V / 3kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508, K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32S/1.6A | Metasol MMS-32S 1.6A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/1.6A O-RING TERMINAL | Metasol MMS-32S 1.6A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 1.6A | Adjustment Range: 1~1.6A (±20% via dial) | Instantaneous Trip: 20.8A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.25kW · 400V/0.55kW · 690V/1.1kW · 230V/1/3HP · 460V/3/4HP · 575V/1HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/2.5A | Metasol MMS-32S 2.5A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/2.5A O-RING TERMINAL | Metasol MMS-32S 2.5A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 2.5A | Adjustment Range: 1.6~2.5A (±20% via dial) | Instantaneous Trip: 32.5A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.37kW · 400V/0.75kW · 690V/1.5kW · 230V/1/2HP · 460V/1-1/2HP · 575V/1-1/2HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/4A | Metasol MMS-32S 4A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/4A O-RING TERMINAL | Metasol MMS-32S 4A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 4A | Adjustment Range: 2.5~4A (±20% via dial) | Instantaneous Trip: 52A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/0.75kW · 400V/1.5kW · 690V/3kW · 230V/1HP · 460V/2HP · 575V/3HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/6A | Metasol MMS-32S 6A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/6A O-RING TERMINAL | Metasol MMS-32S 6A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 6A | Adjustment Range: 4~6A (±20% via dial) | Instantaneous Trip: 78A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/2.2kW · 690V/4kW · 230V/1-1/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/8A | Metasol MMS-32S 8A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/8A O-RING TERMINAL | Metasol MMS-32S 8A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 8A | Adjustment Range: 5~8A (±20% via dial) | Instantaneous Trip: 104A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/1.5kW · 400V/3kW · 690V/5.5kW · 230V/2HP · 460V/5HP · 575V/5HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/10A | Metasol MMS-32S 10A, Standard terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/10A O-RING TERMINAL | Metasol MMS-32S 10A, O-Ring Terminal terminal, Standard (Low Range) | LS ELECTRIC | Frame: 32AF | Capacity Band: Low Range (1.6~10A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 10A | Adjustment Range: 6~10A (±20% via dial) | Instantaneous Trip: 130A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/4kW · 690V/7.5kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |
Metasol MMS-32S Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508, K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
Metasol MMS-32S Manual Motor Starter — Standard (13~40A) variant. 3-pole MCCB-type motor protector combining circuit breaker and thermal overload functions in one compact device. Standard breaking capacity (32AF) with full motor protection: adjustable thermal overload (Class 10), instantaneous magnetic short-circuit, and phase-loss detection. Standard range for general-purpose motors 3~18.5kW (7.5kW @ 220V / 18.5kW @ 440V). Frame: 32AF, width 45mm. Rated insulation voltage Ui = 690V, impulse Uimp = 6kV. Up to 690V Ue, 50/60Hz. Mechanical life 100,000 ops, electrical life 100,000 ops. Operating temperature -20°C to +60°C with automatic temperature compensation. DIN-rail or panel screw mount. Compliant with IEC 60947-1/-2/-4, UL 508, K 60947, GB 14048. Certifications: CE, KEMA, cULus, EAC, Marine (7 societies), KC, CCC. Common accessories across 32/63/100AF: FX/LX aux contacts, LA/LAM alarm contacts, RS shunt / RU undervoltage / RUX undervoltage-with-alarm trip releases, phase bus, E-handle, enclosure. Direct-mount adapter (DA) for Mini-MC, Metasol MC, Susol MC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMS-32S/13A | Metasol MMS-32S 13A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/13A O-RING TERMINAL | Metasol MMS-32S 13A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 13A | Adjustment Range: 9~13A (±20% via dial) | Instantaneous Trip: 169A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/3kW · 400V/5.5kW · 690V/11kW · 230V/3HP · 460V/7-1/2HP · 575V/10HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/17A | Metasol MMS-32S 17A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/17A O-RING TERMINAL | Metasol MMS-32S 17A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 17A | Adjustment Range: 11~17A (±20% via dial) | Instantaneous Trip: 221A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/11kW · 230V/5HP · 460V/10HP · 575V/15HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/22A | Metasol MMS-32S 22A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/22A O-RING TERMINAL | Metasol MMS-32S 22A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 22A | Adjustment Range: 14~22A (±20% via dial) | Instantaneous Trip: 286A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/4kW · 400V/7.5kW · 690V/15kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/26A | Metasol MMS-32S 26A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/26A O-RING TERMINAL | Metasol MMS-32S 26A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 26A | Adjustment Range: 18~26A (±20% via dial) | Instantaneous Trip: 338A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/5.5kW · 400V/11kW · 690V/18.5kW · 230V/7-1/2HP · 460V/15HP · 575V/20HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/32A | Metasol MMS-32S 32A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/32A O-RING TERMINAL | Metasol MMS-32S 32A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 32A | Adjustment Range: 22~32A (±20% via dial) | Instantaneous Trip: 416A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/15kW · 690V/22kW · 230V/10HP · 460V/20HP · 575V/30HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/40A | Metasol MMS-32S 40A, Standard terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: Standard | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC | |
| MMS-32S/40A O-RING TERMINAL | Metasol MMS-32S 40A, O-Ring Terminal terminal, Standard (Standard) | LS ELECTRIC | Frame: 32AF | Capacity Band: Standard (13~40A) | Type: Standard (S) | Pole: 3-Pole | Rated Current Ie: 40A | Adjustment Range: 28~40A (±20% via dial) | Instantaneous Trip: 520A (13 × Ie max) | Rated Voltage Ue: Up to 690V AC, 50/60Hz | Rated Insulation Ui: 690V | Impulse Uimp: 6kV | Overload Protection: Class 10 (thermal, adjustable) | Phase-Loss Protection: Yes | Handle: Toggle | Terminal: O-Ring Terminal | Trip Test Button: Yes | Trip Cause Indicator: No | Mechanical Life: 100,000 operations | Electrical Life: 100,000 operations | Operating Temp: -20°C to +60°C (auto compensation) | Width: 45mm | Weight: ~320g | Mounting: 35mm DIN rail / panel screw | 3-Phase Motor Rating: 230V/7.5kW · 400V/18.5kW · 690V/30kW · 230V/15HP · 460V/30HP · 575V/40HP | Standards: IEC 60947-1/-2/-4, UL 508 (Type E), K 60947, GB 14048 | Certifications: CE, KEMA, cULus, EAC, Marine, KC, CCC |