Molded Case Circuit Breakers
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FTU-60A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-60A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-ATU-320A-3P | Susol Beyond X UTV400-E-ATU-IEC — 320A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-320A-4P | Susol Beyond X UTV400-E-ATU-IEC — 320A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-400A-3P | Susol Beyond X UTV400-E-ATU-IEC — 400A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-400A-4P | Susol Beyond X UTV400-E-ATU-IEC — 400A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-FMU-320A-3P | Susol Beyond X UTV400-E-FMU-IEC — 320A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-320A-4P | Susol Beyond X UTV400-E-FMU-IEC — 320A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-400A-3P | Susol Beyond X UTV400-E-FMU-IEC — 400A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-400A-4P | Susol Beyond X UTV400-E-FMU-IEC — 400A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-FTU-320A-3P | Susol Beyond X UTV400-E-FTU-IEC — 320A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-320A-4P | Susol Beyond X UTV400-E-FTU-IEC — 320A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-400A-3P | Susol Beyond X UTV400-E-FTU-IEC — 400A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-400A-4P | Susol Beyond X UTV400-E-FTU-IEC — 400A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-ATU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-ATU-320A-3P | Susol Beyond X UTV400-N-ATU-IEC — 320A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-320A-4P | Susol Beyond X UTV400-N-ATU-IEC — 320A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-400A-3P | Susol Beyond X UTV400-N-ATU-IEC — 400A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-400A-4P | Susol Beyond X UTV400-N-ATU-IEC — 400A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-FMU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FMU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-FMU-320A-3P | Susol Beyond X UTV400-N-FMU-IEC — 320A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-320A-4P | Susol Beyond X UTV400-N-FMU-IEC — 320A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-400A-3P | Susol Beyond X UTV400-N-FMU-IEC — 400A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-400A-4P | Susol Beyond X UTV400-N-FMU-IEC — 400A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-FTU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FTU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-FTU-320A-3P | Susol Beyond X UTV400-N-FTU-IEC — 320A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-320A-4P | Susol Beyond X UTV400-N-FTU-IEC — 320A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-400A-3P | Susol Beyond X UTV400-N-FTU-IEC — 400A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-400A-4P | Susol Beyond X UTV400-N-FTU-IEC — 400A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |