Circuit Breakers
LS ELECTRIC Beyond X Residential MCB/RCBO BF50-K-N family. | Application: Residential distribution panel (MCB). | Frame: 50AF | Type: N-type (Normal breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 5kA @ 220V AC / 5kA @ 380V AC | Ics: 100% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 36 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO BF50-K-N family. | Application: Residential distribution panel (MCB). | Frame: 50AF | Type: N-type (Normal breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 5kA @ 220V AC / 5kA @ 380V AC | Ics: 100% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 36 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-BF50-K-N | [LS ELECTRIC] — BF50-K-N Beyond X Residential MCB/RCBO (N-type (Normal breaking), 50AF MCB, 5kA @ 220V AC / 5kA @ 380V AC, 1~50A) | LS ELECTRIC |
LS ELECTRIC Beyond X Residential MCB/RCBO BF60-K-H family. | Application: Residential distribution panel (MCB). | Frame: 60AF | Type: H-type (High breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 380V AC | Ics: 75% Icn | Rated current (In): 63A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO BF60-K-H family. | Application: Residential distribution panel (MCB). | Frame: 60AF | Type: H-type (High breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 380V AC | Ics: 75% Icn | Rated current (In): 63A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-BF60-K-H | [LS ELECTRIC] — BF60-K-H Beyond X Residential MCB/RCBO (H-type (High breaking), 60AF MCB, 10kA @ 220V AC / 10kA @ 380V AC, 63A) | LS ELECTRIC |
LS ELECTRIC Beyond X Residential MCB/RCBO BF60-K-N family. | Application: Residential distribution panel (MCB). | Frame: 60AF | Type: N-type (Normal breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 5kA @ 220V AC / 5kA @ 380V AC | Ics: 100% Icn | Rated current (In): 63A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 3 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO BF60-K-N family. | Application: Residential distribution panel (MCB). | Frame: 60AF | Type: N-type (Normal breaking) | Trip method: Thermal-Magnetic | Trip curve: B / C / D | Breaking capacity Icn: 5kA @ 220V AC / 5kA @ 380V AC | Ics: 100% Icn | Rated current (In): 63A | Pole: 1P / 2P / 3P | Mounting: Holder | Uimp: 4kV | Standard: KS C 8332 / IEC 60898-1 | 3 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-BF60-K-N | [LS ELECTRIC] — BF60-K-N Beyond X Residential MCB/RCBO (N-type (Normal breaking), 60AF MCB, 5kA @ 220V AC / 5kA @ 380V AC, 63A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BK63H family. | Application: Industrial distribution panel (MCB). | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Pole: 1P / 2P / 3P / 4P | Mounting: DIN rail (35mm) | Uimp: 6kV | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | 52 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BK63H family. | Application: Industrial distribution panel (MCB). | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Pole: 1P / 2P / 3P / 4P | Mounting: DIN rail (35mm) | Uimp: 6kV | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | 52 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BK63H/1A 1P | BK63H BK63H — BK63H 1A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 1A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/2A 1P | BK63H BK63H — BK63H 2A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 2A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/3A 1P | BK63H BK63H — BK63H 3A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 3A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/4A 1P | BK63H BK63H — BK63H 4A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 4A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/6A 1P | BK63H BK63H — BK63H 6A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 6A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/10A 1P | BK63H BK63H — BK63H 10A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 10A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/16A 1P | BK63H BK63H — BK63H 16A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 16A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/20A 1P | BK63H BK63H — BK63H 20A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 20A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/25A 1P | BK63H BK63H — BK63H 25A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 25A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/32A 1P | BK63H BK63H — BK63H 32A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 32A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/40A 1P | BK63H BK63H — BK63H 40A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 40A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/50A 1P | BK63H BK63H — BK63H 50A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 50A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/63A 1P | BK63H BK63H — BK63H 63A 1P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 63A | Pole: 1P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/1A 2P | BK63H BK63H — BK63H 1A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 1A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/2A 2P | BK63H BK63H — BK63H 2A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 2A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/3A 2P | BK63H BK63H — BK63H 3A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 3A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/4A 2P | BK63H BK63H — BK63H 4A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 4A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/6A 2P | BK63H BK63H — BK63H 6A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 6A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/10A 2P | BK63H BK63H — BK63H 10A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/16A 2P | BK63H BK63H — BK63H 16A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 16A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/20A 2P | BK63H BK63H — BK63H 20A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/25A 2P | BK63H BK63H — BK63H 25A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 25A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/32A 2P | BK63H BK63H — BK63H 32A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 32A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/40A 2P | BK63H BK63H — BK63H 40A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/50A 2P | BK63H BK63H — BK63H 50A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/63A 2P | BK63H BK63H — BK63H 63A 2P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 63A | Pole: 2P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/1A 3P | BK63H BK63H — BK63H 1A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 1A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/2A 3P | BK63H BK63H — BK63H 2A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 2A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/3A 3P | BK63H BK63H — BK63H 3A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 3A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/4A 3P | BK63H BK63H — BK63H 4A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 4A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/6A 3P | BK63H BK63H — BK63H 6A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 6A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/10A 3P | BK63H BK63H — BK63H 10A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/16A 3P | BK63H BK63H — BK63H 16A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 16A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/20A 3P | BK63H BK63H — BK63H 20A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/25A 3P | BK63H BK63H — BK63H 25A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 25A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/32A 3P | BK63H BK63H — BK63H 32A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 32A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/40A 3P | BK63H BK63H — BK63H 40A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/50A 3P | BK63H BK63H — BK63H 50A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/63A 3P | BK63H BK63H — BK63H 63A 3P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 63A | Pole: 3P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/1A 4P | BK63H BK63H — BK63H 1A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 1A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/2A 4P | BK63H BK63H — BK63H 2A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 2A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/3A 4P | BK63H BK63H — BK63H 3A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 3A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/4A 4P | BK63H BK63H — BK63H 4A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 4A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/6A 4P | BK63H BK63H — BK63H 6A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 6A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/10A 4P | BK63H BK63H — BK63H 10A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 10A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/16A 4P | BK63H BK63H — BK63H 16A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 16A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/20A 4P | BK63H BK63H — BK63H 20A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 20A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/25A 4P | BK63H BK63H — BK63H 25A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 25A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/32A 4P | BK63H BK63H — BK63H 32A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 32A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/40A 4P | BK63H BK63H — BK63H 40A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 40A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/50A 4P | BK63H BK63H — BK63H 50A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 50A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA | |
| BK63H/63A 4P | BK63H BK63H — BK63H 63A 4P (MCB) | LS ELECTRIC | Frame: 63AF | Type: Miniature Circuit Breaker (1P/2P/3P/4P) | Rated current (In): 63A | Pole: 4P | Breaking capacity Icn: 10kA @ 220V AC / 10kA @ 415V AC | Ics: 75% Icn | Trip method: Thermal-Coil Magnetic | Trip curve: B (4×In) / C (7.5×In) / D (12×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: 240V (1P) / 240/415V (2/3/4P) | Standard: KSC 8332 / KC / IEC 60898 / IEC 60947-2 | Application: Industrial distribution panel (MCB) | Approval: CE, UL1077, KC, ABS, BV, DNV, GL, KR, LR, RINA |
LS ELECTRIC Beyond X BK63H HOUSE family. | Application: Residential/commercial. | Frame: 63AF | Type: AC Miniature Circuit Breaker | Standard: IEC60898-1 / IEC60947-2 | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P / 4P | Breaking capacity: 10kA (Icu) | Ics: 75% Icu | Trip curve: B (4In) / C (7.5In) / D (12In) | Trip method: Thermal-Magnetic | Voltage: 240VAC (1P) / 415VAC (2~4P) | DC voltage: 60VDC (1P) / 125VDC (2~4P) | Uimp: 6kV | Ui: 500V | Mounting: 35mm DIN rail | Terminal: Lug/Screw dual | Endurance: 10,000 (electrical) / 20,000 (mechanical) | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS — see RFQ table for specific MPN.
LS ELECTRIC Beyond X BK63H HOUSE family. | Application: Residential/commercial. | Frame: 63AF | Type: AC Miniature Circuit Breaker | Standard: IEC60898-1 / IEC60947-2 | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P / 4P | Breaking capacity: 10kA (Icu) | Ics: 75% Icu | Trip curve: B (4In) / C (7.5In) / D (12In) | Trip method: Thermal-Magnetic | Voltage: 240VAC (1P) / 415VAC (2~4P) | DC voltage: 60VDC (1P) / 125VDC (2~4P) | Uimp: 6kV | Ui: 500V | Mounting: 35mm DIN rail | Terminal: Lug/Screw dual | Endurance: 10,000 (electrical) / 20,000 (mechanical) | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BK63H B1/1P | BK63H B1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C1/1P | BK63H C1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D1/1P | BK63H D1A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B2/1P | BK63H B2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C2/1P | BK63H C2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D2/1P | BK63H D2A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B3/1P | BK63H B3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C3/1P | BK63H C3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D3/1P | BK63H D3A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B4/1P | BK63H B4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C4/1P | BK63H C4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D4/1P | BK63H D4A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B6/1P | BK63H B6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C6/1P | BK63H C6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D6/1P | BK63H D6A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B10/1P | BK63H B10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C10/1P | BK63H C10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D10/1P | BK63H D10A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B16/1P | BK63H B16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C16/1P | BK63H C16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D16/1P | BK63H D16A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B20/1P | BK63H B20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C20/1P | BK63H C20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D20/1P | BK63H D20A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B25/1P | BK63H B25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C25/1P | BK63H C25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D25/1P | BK63H D25A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B32/1P | BK63H B32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C32/1P | BK63H C32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D32/1P | BK63H D32A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B40/1P | BK63H B40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C40/1P | BK63H C40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D40/1P | BK63H D40A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B50/1P | BK63H B50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C50/1P | BK63H C50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D50/1P | BK63H D50A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B63/1P | BK63H B63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C63/1P | BK63H C63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D63/1P | BK63H D63A 1P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 240VAC | DC: 60V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B1/2P | BK63H B1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C1/2P | BK63H C1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D1/2P | BK63H D1A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B2/2P | BK63H B2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C2/2P | BK63H C2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D2/2P | BK63H D2A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B3/2P | BK63H B3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C3/2P | BK63H C3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D3/2P | BK63H D3A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B4/2P | BK63H B4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C4/2P | BK63H C4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D4/2P | BK63H D4A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B6/2P | BK63H B6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C6/2P | BK63H C6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D6/2P | BK63H D6A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B10/2P | BK63H B10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C10/2P | BK63H C10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D10/2P | BK63H D10A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B16/2P | BK63H B16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C16/2P | BK63H C16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D16/2P | BK63H D16A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B20/2P | BK63H B20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C20/2P | BK63H C20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D20/2P | BK63H D20A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B25/2P | BK63H B25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C25/2P | BK63H C25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D25/2P | BK63H D25A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B32/2P | BK63H B32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C32/2P | BK63H C32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D32/2P | BK63H D32A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B40/2P | BK63H B40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C40/2P | BK63H C40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D40/2P | BK63H D40A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B50/2P | BK63H B50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C50/2P | BK63H C50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D50/2P | BK63H D50A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B63/2P | BK63H B63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C63/2P | BK63H C63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D63/2P | BK63H D63A 2P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B1/3P | BK63H B1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C1/3P | BK63H C1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D1/3P | BK63H D1A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B2/3P | BK63H B2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C2/3P | BK63H C2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D2/3P | BK63H D2A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B3/3P | BK63H B3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C3/3P | BK63H C3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D3/3P | BK63H D3A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B4/3P | BK63H B4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C4/3P | BK63H C4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D4/3P | BK63H D4A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B6/3P | BK63H B6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C6/3P | BK63H C6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D6/3P | BK63H D6A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B10/3P | BK63H B10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C10/3P | BK63H C10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D10/3P | BK63H D10A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B16/3P | BK63H B16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C16/3P | BK63H C16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D16/3P | BK63H D16A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B20/3P | BK63H B20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C20/3P | BK63H C20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D20/3P | BK63H D20A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B25/3P | BK63H B25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C25/3P | BK63H C25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D25/3P | BK63H D25A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B32/3P | BK63H B32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C32/3P | BK63H C32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D32/3P | BK63H D32A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B40/3P | BK63H B40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C40/3P | BK63H C40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D40/3P | BK63H D40A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B50/3P | BK63H B50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C50/3P | BK63H C50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D50/3P | BK63H D50A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B63/3P | BK63H B63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C63/3P | BK63H C63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D63/3P | BK63H D63A 3P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B1/4P | BK63H B1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C1/4P | BK63H C1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D1/4P | BK63H D1A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B2/4P | BK63H B2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C2/4P | BK63H C2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D2/4P | BK63H D2A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B3/4P | BK63H B3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C3/4P | BK63H C3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D3/4P | BK63H D3A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B4/4P | BK63H B4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C4/4P | BK63H C4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D4/4P | BK63H D4A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B6/4P | BK63H B6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C6/4P | BK63H C6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D6/4P | BK63H D6A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B10/4P | BK63H B10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C10/4P | BK63H C10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D10/4P | BK63H D10A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B16/4P | BK63H B16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C16/4P | BK63H C16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D16/4P | BK63H D16A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B20/4P | BK63H B20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C20/4P | BK63H C20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D20/4P | BK63H D20A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B25/4P | BK63H B25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C25/4P | BK63H C25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D25/4P | BK63H D25A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B32/4P | BK63H B32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C32/4P | BK63H C32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D32/4P | BK63H D32A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B40/4P | BK63H B40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C40/4P | BK63H C40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D40/4P | BK63H D40A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B50/4P | BK63H B50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C50/4P | BK63H C50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D50/4P | BK63H D50A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H B63/4P | BK63H B63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H C63/4P | BK63H C63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS | |
| BK63H D63/4P | BK63H D63A 4P (HOUSE, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 4P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Ics: 75% Icu | Voltage: 415VAC | DC: 125V | Standard: IEC60898-1 / IEC60947-2 | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB | Marine: ABS, BV, DNV, GL, KR, LR, RINA, RS |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BK63H-DC family. | Application: Industrial distribution panel (DC Circuit MCB). | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Pole: 1P / 2P / 3P / 4P | Mounting: DIN rail (35mm) | Uimp: 6kV | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Approval: CE, SEMKO CB | 52 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BK63H-DC family. | Application: Industrial distribution panel (DC Circuit MCB). | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Rated current (In): 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A | Pole: 1P / 2P / 3P / 4P | Mounting: DIN rail (35mm) | Uimp: 6kV | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Approval: CE, SEMKO CB | 52 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BK63H DC/1A 1P | BK63H DC BK63H-DC — BK63H DC 1A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 1A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/2A 1P | BK63H DC BK63H-DC — BK63H DC 2A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 2A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/3A 1P | BK63H DC BK63H-DC — BK63H DC 3A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 3A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/4A 1P | BK63H DC BK63H-DC — BK63H DC 4A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 4A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/6A 1P | BK63H DC BK63H-DC — BK63H DC 6A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 6A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/10A 1P | BK63H DC BK63H-DC — BK63H DC 10A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 10A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/16A 1P | BK63H DC BK63H-DC — BK63H DC 16A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 16A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/20A 1P | BK63H DC BK63H-DC — BK63H DC 20A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 20A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/25A 1P | BK63H DC BK63H-DC — BK63H DC 25A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 25A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/32A 1P | BK63H DC BK63H-DC — BK63H DC 32A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 32A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/40A 1P | BK63H DC BK63H-DC — BK63H DC 40A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 40A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/50A 1P | BK63H DC BK63H-DC — BK63H DC 50A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 50A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/63A 1P | BK63H DC BK63H-DC — BK63H DC 63A 1P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 63A | Pole: 1P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/1A 2P | BK63H DC BK63H-DC — BK63H DC 1A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 1A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/2A 2P | BK63H DC BK63H-DC — BK63H DC 2A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 2A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/3A 2P | BK63H DC BK63H-DC — BK63H DC 3A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 3A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/4A 2P | BK63H DC BK63H-DC — BK63H DC 4A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 4A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/6A 2P | BK63H DC BK63H-DC — BK63H DC 6A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 6A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/10A 2P | BK63H DC BK63H-DC — BK63H DC 10A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/16A 2P | BK63H DC BK63H-DC — BK63H DC 16A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 16A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/20A 2P | BK63H DC BK63H-DC — BK63H DC 20A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/25A 2P | BK63H DC BK63H-DC — BK63H DC 25A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 25A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/32A 2P | BK63H DC BK63H-DC — BK63H DC 32A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 32A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/40A 2P | BK63H DC BK63H-DC — BK63H DC 40A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/50A 2P | BK63H DC BK63H-DC — BK63H DC 50A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/63A 2P | BK63H DC BK63H-DC — BK63H DC 63A 2P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 63A | Pole: 2P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/1A 3P | BK63H DC BK63H-DC — BK63H DC 1A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 1A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/2A 3P | BK63H DC BK63H-DC — BK63H DC 2A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 2A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/3A 3P | BK63H DC BK63H-DC — BK63H DC 3A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 3A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/4A 3P | BK63H DC BK63H-DC — BK63H DC 4A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 4A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/6A 3P | BK63H DC BK63H-DC — BK63H DC 6A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 6A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/10A 3P | BK63H DC BK63H-DC — BK63H DC 10A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/16A 3P | BK63H DC BK63H-DC — BK63H DC 16A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 16A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/20A 3P | BK63H DC BK63H-DC — BK63H DC 20A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/25A 3P | BK63H DC BK63H-DC — BK63H DC 25A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 25A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/32A 3P | BK63H DC BK63H-DC — BK63H DC 32A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 32A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/40A 3P | BK63H DC BK63H-DC — BK63H DC 40A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/50A 3P | BK63H DC BK63H-DC — BK63H DC 50A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/63A 3P | BK63H DC BK63H-DC — BK63H DC 63A 3P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 63A | Pole: 3P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/1A 4P | BK63H DC BK63H-DC — BK63H DC 1A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 1A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/2A 4P | BK63H DC BK63H-DC — BK63H DC 2A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 2A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/3A 4P | BK63H DC BK63H-DC — BK63H DC 3A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 3A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/4A 4P | BK63H DC BK63H-DC — BK63H DC 4A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 4A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/6A 4P | BK63H DC BK63H-DC — BK63H DC 6A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 6A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/10A 4P | BK63H DC BK63H-DC — BK63H DC 10A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 10A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/16A 4P | BK63H DC BK63H-DC — BK63H DC 16A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 16A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/20A 4P | BK63H DC BK63H-DC — BK63H DC 20A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 20A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/25A 4P | BK63H DC BK63H-DC — BK63H DC 25A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 25A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/32A 4P | BK63H DC BK63H-DC — BK63H DC 32A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 32A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/40A 4P | BK63H DC BK63H-DC — BK63H DC 40A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 40A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/50A 4P | BK63H DC BK63H-DC — BK63H DC 50A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 50A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB | |
| BK63H DC/63A 4P | BK63H DC BK63H-DC — BK63H DC 63A 4P (MCB-DC) | LS ELECTRIC | Frame: 63AF | Type: DC Circuit Miniature Circuit Breaker (PV/Renewable) | Rated current (In): 63A | Pole: 4P | Breaking capacity Icn: 10kA DC | Ics: 75% Icn | Trip method: Thermal-Magnetic | Trip curve: B (5×In) / C (8×In) | Uimp: 6kV | Mounting: DIN rail (35mm) | Voltage: DC 250V (1P) / 500V (2P) / 750V (3P) / 1000V (4P) | Standard: — / IEC 60947-2 | Application: Industrial distribution panel (MCB-DC) | Approval: CE, SEMKO CB |
LS ELECTRIC Beyond X BK63HU IEC family. | Application: Industrial/control panel. | Frame: 63AF | Type: AC Miniature Circuit Breaker (IEC) | Standard: IEC60947-2 | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P | Breaking capacity: 10kA (1P) / 6kA (2P, 3P) | Trip curve: B (4In) / C (7.5In) / D (12In) | Trip method: Thermal-Magnetic | Voltage: 240VAC (1P) / 440VAC (2~3P) | Uimp: 6kV | Ui: 500V | Mounting: 35mm DIN rail | Terminal: Lug/Screw dual (M5) | Wire: 18-6 AWG (single) / 18-10 AWG (double) | Endurance: 10,000 (electrical) / 20,000 (mechanical) | Approval: CE, KC, SEMKO CB, Nuclear Q-Class — see RFQ table for specific MPN.
LS ELECTRIC Beyond X BK63HU IEC family. | Application: Industrial/control panel. | Frame: 63AF | Type: AC Miniature Circuit Breaker (IEC) | Standard: IEC60947-2 | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P | Breaking capacity: 10kA (1P) / 6kA (2P, 3P) | Trip curve: B (4In) / C (7.5In) / D (12In) | Trip method: Thermal-Magnetic | Voltage: 240VAC (1P) / 440VAC (2~3P) | Uimp: 6kV | Ui: 500V | Mounting: 35mm DIN rail | Terminal: Lug/Screw dual (M5) | Wire: 18-6 AWG (single) / 18-10 AWG (double) | Endurance: 10,000 (electrical) / 20,000 (mechanical) | Approval: CE, KC, SEMKO CB, Nuclear Q-Class — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BK63HU B1/1P | BK63HU B1A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C1/1P | BK63HU C1A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D1/1P | BK63HU D1A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B2/1P | BK63HU B2A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C2/1P | BK63HU C2A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D2/1P | BK63HU D2A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B3/1P | BK63HU B3A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C3/1P | BK63HU C3A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D3/1P | BK63HU D3A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B4/1P | BK63HU B4A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C4/1P | BK63HU C4A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D4/1P | BK63HU D4A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B5/1P | BK63HU B5A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C5/1P | BK63HU C5A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D5/1P | BK63HU D5A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B6/1P | BK63HU B6A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C6/1P | BK63HU C6A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D6/1P | BK63HU D6A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B8/1P | BK63HU B8A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C8/1P | BK63HU C8A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D8/1P | BK63HU D8A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B10/1P | BK63HU B10A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C10/1P | BK63HU C10A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D10/1P | BK63HU D10A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B15/1P | BK63HU B15A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C15/1P | BK63HU C15A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D15/1P | BK63HU D15A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B16/1P | BK63HU B16A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C16/1P | BK63HU C16A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D16/1P | BK63HU D16A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B20/1P | BK63HU B20A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C20/1P | BK63HU C20A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D20/1P | BK63HU D20A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B25/1P | BK63HU B25A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C25/1P | BK63HU C25A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D25/1P | BK63HU D25A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B30/1P | BK63HU B30A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C30/1P | BK63HU C30A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D30/1P | BK63HU D30A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B32/1P | BK63HU B32A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C32/1P | BK63HU C32A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D32/1P | BK63HU D32A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B40/1P | BK63HU B40A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C40/1P | BK63HU C40A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D40/1P | BK63HU D40A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B50/1P | BK63HU B50A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C50/1P | BK63HU C50A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D50/1P | BK63HU D50A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B63/1P | BK63HU B63A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C63/1P | BK63HU C63A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D63/1P | BK63HU D63A 1P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 10kA | Voltage: 240VAC | DC: 60V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B1/2P | BK63HU B1A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C1/2P | BK63HU C1A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D1/2P | BK63HU D1A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B2/2P | BK63HU B2A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C2/2P | BK63HU C2A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D2/2P | BK63HU D2A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B3/2P | BK63HU B3A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C3/2P | BK63HU C3A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D3/2P | BK63HU D3A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B4/2P | BK63HU B4A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C4/2P | BK63HU C4A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D4/2P | BK63HU D4A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B5/2P | BK63HU B5A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C5/2P | BK63HU C5A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D5/2P | BK63HU D5A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B6/2P | BK63HU B6A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C6/2P | BK63HU C6A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D6/2P | BK63HU D6A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B8/2P | BK63HU B8A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C8/2P | BK63HU C8A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D8/2P | BK63HU D8A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B10/2P | BK63HU B10A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C10/2P | BK63HU C10A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D10/2P | BK63HU D10A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B15/2P | BK63HU B15A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C15/2P | BK63HU C15A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D15/2P | BK63HU D15A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B16/2P | BK63HU B16A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C16/2P | BK63HU C16A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D16/2P | BK63HU D16A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B20/2P | BK63HU B20A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C20/2P | BK63HU C20A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D20/2P | BK63HU D20A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B25/2P | BK63HU B25A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C25/2P | BK63HU C25A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D25/2P | BK63HU D25A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B30/2P | BK63HU B30A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C30/2P | BK63HU C30A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D30/2P | BK63HU D30A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B32/2P | BK63HU B32A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C32/2P | BK63HU C32A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D32/2P | BK63HU D32A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B40/2P | BK63HU B40A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C40/2P | BK63HU C40A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D40/2P | BK63HU D40A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B50/2P | BK63HU B50A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C50/2P | BK63HU C50A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D50/2P | BK63HU D50A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B63/2P | BK63HU B63A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C63/2P | BK63HU C63A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D63/2P | BK63HU D63A 2P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B1/3P | BK63HU B1A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C1/3P | BK63HU C1A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D1/3P | BK63HU D1A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B2/3P | BK63HU B2A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C2/3P | BK63HU C2A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D2/3P | BK63HU D2A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B3/3P | BK63HU B3A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C3/3P | BK63HU C3A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D3/3P | BK63HU D3A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B4/3P | BK63HU B4A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C4/3P | BK63HU C4A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D4/3P | BK63HU D4A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B5/3P | BK63HU B5A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C5/3P | BK63HU C5A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D5/3P | BK63HU D5A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B6/3P | BK63HU B6A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C6/3P | BK63HU C6A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D6/3P | BK63HU D6A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B8/3P | BK63HU B8A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C8/3P | BK63HU C8A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D8/3P | BK63HU D8A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B10/3P | BK63HU B10A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C10/3P | BK63HU C10A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D10/3P | BK63HU D10A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B15/3P | BK63HU B15A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C15/3P | BK63HU C15A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D15/3P | BK63HU D15A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B16/3P | BK63HU B16A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C16/3P | BK63HU C16A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D16/3P | BK63HU D16A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B20/3P | BK63HU B20A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C20/3P | BK63HU C20A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D20/3P | BK63HU D20A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B25/3P | BK63HU B25A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C25/3P | BK63HU C25A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D25/3P | BK63HU D25A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B30/3P | BK63HU B30A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C30/3P | BK63HU C30A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D30/3P | BK63HU D30A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B32/3P | BK63HU B32A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C32/3P | BK63HU C32A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D32/3P | BK63HU D32A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B40/3P | BK63HU B40A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C40/3P | BK63HU C40A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D40/3P | BK63HU D40A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B50/3P | BK63HU B50A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C50/3P | BK63HU C50A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D50/3P | BK63HU D50A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU B63/3P | BK63HU B63A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU C63/3P | BK63HU C63A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) | |
| BK63HU D63/3P | BK63HU D63A 3P (IEC, AC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity Icu: 6kA | Voltage: 440VAC | DC: 125V | Standard: IEC60947-2 | Uimp: 6kV | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual | Endurance: 10,000 elec / 20,000 mech | Approval: CE, KC, SEMKO CB, Q-Class (Nuclear) |
LS ELECTRIC Beyond X BK63HU UL489 family. | Application: North America industrial/panel. | Frame: 63AF | Type: AC/DC Miniature Circuit Breaker | Standard: UL489, UL486E (Lug) | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P | Breaking capacity: 10kA | Trip curve: B (3-5In) / C (5-10In) / D (10-20In) | Trip method: Thermal-Magnetic | Voltage AC: 277V (120/240V) / 120/240V / 480Y/277V (240V) / 240V | Voltage DC: 60V (1P) / 125V (2-3P) | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual, Cu only | Wire: 18-6 AWG (single) / 18-10 AWG (double) | Endurance: 6,000 (electrical) | Operating frequency: 360 ops/hour | Approval: UL Listed — see RFQ table for specific MPN.
LS ELECTRIC Beyond X BK63HU UL489 family. | Application: North America industrial/panel. | Frame: 63AF | Type: AC/DC Miniature Circuit Breaker | Standard: UL489, UL486E (Lug) | Rated current (In): 1A~63A | Pole: 1P / 2P / 3P | Breaking capacity: 10kA | Trip curve: B (3-5In) / C (5-10In) / D (10-20In) | Trip method: Thermal-Magnetic | Voltage AC: 277V (120/240V) / 120/240V / 480Y/277V (240V) / 240V | Voltage DC: 60V (1P) / 125V (2-3P) | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual, Cu only | Wire: 18-6 AWG (single) / 18-10 AWG (double) | Endurance: 6,000 (electrical) | Operating frequency: 360 ops/hour | Approval: UL Listed — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BK63HU B1/1P UL | BK63HU B1A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C1/1P UL | BK63HU C1A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D1/1P UL | BK63HU D1A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B2/1P UL | BK63HU B2A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C2/1P UL | BK63HU C2A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D2/1P UL | BK63HU D2A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B3/1P UL | BK63HU B3A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C3/1P UL | BK63HU C3A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D3/1P UL | BK63HU D3A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B4/1P UL | BK63HU B4A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C4/1P UL | BK63HU C4A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D4/1P UL | BK63HU D4A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B5/1P UL | BK63HU B5A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C5/1P UL | BK63HU C5A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D5/1P UL | BK63HU D5A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B6/1P UL | BK63HU B6A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C6/1P UL | BK63HU C6A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D6/1P UL | BK63HU D6A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B8/1P UL | BK63HU B8A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C8/1P UL | BK63HU C8A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D8/1P UL | BK63HU D8A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B10/1P UL | BK63HU B10A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C10/1P UL | BK63HU C10A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D10/1P UL | BK63HU D10A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B15/1P UL | BK63HU B15A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C15/1P UL | BK63HU C15A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D15/1P UL | BK63HU D15A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B16/1P UL | BK63HU B16A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C16/1P UL | BK63HU C16A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D16/1P UL | BK63HU D16A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B20/1P UL | BK63HU B20A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C20/1P UL | BK63HU C20A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D20/1P UL | BK63HU D20A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B25/1P UL | BK63HU B25A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C25/1P UL | BK63HU C25A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D25/1P UL | BK63HU D25A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 277V (120/240V) | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B30/1P UL | BK63HU B30A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C30/1P UL | BK63HU C30A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D30/1P UL | BK63HU D30A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B32/1P UL | BK63HU B32A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C32/1P UL | BK63HU C32A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D32/1P UL | BK63HU D32A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B40/1P UL | BK63HU B40A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C40/1P UL | BK63HU C40A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D40/1P UL | BK63HU D40A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B50/1P UL | BK63HU B50A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C50/1P UL | BK63HU C50A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D50/1P UL | BK63HU D50A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B60/1P UL | BK63HU B60A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 60A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C60/1P UL | BK63HU C60A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 60A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D60/1P UL | BK63HU D60A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 60A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B63/1P UL | BK63HU B63A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C63/1P UL | BK63HU C63A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D63/1P UL | BK63HU D63A 1P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 1P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 120/240V | Voltage DC: 60V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B1/2P UL | BK63HU B1A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C1/2P UL | BK63HU C1A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D1/2P UL | BK63HU D1A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B2/2P UL | BK63HU B2A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C2/2P UL | BK63HU C2A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D2/2P UL | BK63HU D2A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B3/2P UL | BK63HU B3A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C3/2P UL | BK63HU C3A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D3/2P UL | BK63HU D3A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B4/2P UL | BK63HU B4A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C4/2P UL | BK63HU C4A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D4/2P UL | BK63HU D4A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B5/2P UL | BK63HU B5A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C5/2P UL | BK63HU C5A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D5/2P UL | BK63HU D5A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B6/2P UL | BK63HU B6A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C6/2P UL | BK63HU C6A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D6/2P UL | BK63HU D6A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B8/2P UL | BK63HU B8A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C8/2P UL | BK63HU C8A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D8/2P UL | BK63HU D8A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B10/2P UL | BK63HU B10A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C10/2P UL | BK63HU C10A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D10/2P UL | BK63HU D10A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B15/2P UL | BK63HU B15A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C15/2P UL | BK63HU C15A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D15/2P UL | BK63HU D15A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B16/2P UL | BK63HU B16A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C16/2P UL | BK63HU C16A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D16/2P UL | BK63HU D16A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B20/2P UL | BK63HU B20A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C20/2P UL | BK63HU C20A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D20/2P UL | BK63HU D20A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B25/2P UL | BK63HU B25A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C25/2P UL | BK63HU C25A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D25/2P UL | BK63HU D25A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B30/2P UL | BK63HU B30A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C30/2P UL | BK63HU C30A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D30/2P UL | BK63HU D30A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B32/2P UL | BK63HU B32A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C32/2P UL | BK63HU C32A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D32/2P UL | BK63HU D32A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B40/2P UL | BK63HU B40A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C40/2P UL | BK63HU C40A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D40/2P UL | BK63HU D40A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B50/2P UL | BK63HU B50A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C50/2P UL | BK63HU C50A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D50/2P UL | BK63HU D50A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B60/2P UL | BK63HU B60A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 60A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C60/2P UL | BK63HU C60A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 60A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D60/2P UL | BK63HU D60A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 60A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B63/2P UL | BK63HU B63A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C63/2P UL | BK63HU C63A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D63/2P UL | BK63HU D63A 2P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 2P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B1/3P UL | BK63HU B1A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C1/3P UL | BK63HU C1A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D1/3P UL | BK63HU D1A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 1A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B2/3P UL | BK63HU B2A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C2/3P UL | BK63HU C2A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D2/3P UL | BK63HU D2A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 2A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B3/3P UL | BK63HU B3A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C3/3P UL | BK63HU C3A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D3/3P UL | BK63HU D3A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 3A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B4/3P UL | BK63HU B4A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C4/3P UL | BK63HU C4A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D4/3P UL | BK63HU D4A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 4A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B5/3P UL | BK63HU B5A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C5/3P UL | BK63HU C5A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D5/3P UL | BK63HU D5A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 5A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B6/3P UL | BK63HU B6A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C6/3P UL | BK63HU C6A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D6/3P UL | BK63HU D6A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 6A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B8/3P UL | BK63HU B8A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C8/3P UL | BK63HU C8A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D8/3P UL | BK63HU D8A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 8A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B10/3P UL | BK63HU B10A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C10/3P UL | BK63HU C10A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D10/3P UL | BK63HU D10A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 10A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B15/3P UL | BK63HU B15A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C15/3P UL | BK63HU C15A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D15/3P UL | BK63HU D15A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 15A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B16/3P UL | BK63HU B16A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C16/3P UL | BK63HU C16A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D16/3P UL | BK63HU D16A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 16A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B20/3P UL | BK63HU B20A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C20/3P UL | BK63HU C20A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D20/3P UL | BK63HU D20A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 20A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B25/3P UL | BK63HU B25A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C25/3P UL | BK63HU C25A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D25/3P UL | BK63HU D25A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 25A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 480Y/277V (240V) | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B30/3P UL | BK63HU B30A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C30/3P UL | BK63HU C30A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D30/3P UL | BK63HU D30A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 30A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B32/3P UL | BK63HU B32A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C32/3P UL | BK63HU C32A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D32/3P UL | BK63HU D32A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 32A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B40/3P UL | BK63HU B40A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C40/3P UL | BK63HU C40A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D40/3P UL | BK63HU D40A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 40A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B50/3P UL | BK63HU B50A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C50/3P UL | BK63HU C50A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D50/3P UL | BK63HU D50A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 50A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B60/3P UL | BK63HU B60A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 60A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C60/3P UL | BK63HU C60A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 60A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D60/3P UL | BK63HU D60A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 60A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU B63/3P UL | BK63HU B63A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: B (3-5In, residential/lighting) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU C63/3P UL | BK63HU C63A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: C (5-10In, general/inductive) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed | |
| BK63HU D63/3P UL | BK63HU D63A 3P (UL489, AC/DC MCB) | LS ELECTRIC | Frame: 63AF | Pole: 3P | Rated current (In): 63A | Trip curve: D (10-20In, motor/transformer) | Breaking capacity: 10kA | Voltage AC: 240V | Voltage DC: 125V | Standard: UL489, UL486E | Trip method: Thermal-Magnetic | Mounting: 35mm DIN rail | Terminal: Lug/Screw M5 dual (Cu only) | Endurance: 6,000 elec | Operating frequency: 360 ops/hour | Approval: UL Listed |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BS32 family. | Application: Industrial distribution panel (MCB). | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 6A, 10A, 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KSC 8321 / — | Note: BS32c=1.5kA, BS32d=2.5kA | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO BS32 family. | Application: Industrial distribution panel (MCB). | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 6A, 10A, 15A, 20A, 30A | Pole: 2P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V | Standard: KSC 8321 / — | Note: BS32c=1.5kA, BS32d=2.5kA | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BS32c/6 | BS BS32 — BS32c 6A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 6A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32c/10 | BS BS32 — BS32c 10A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32c/15 | BS BS32 — BS32c 15A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32c/20 | BS BS32 — BS32c 20A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32c/30 | BS BS32 — BS32c 30A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32d/10 | BS BS32 — BS32d 10A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32d/15 | BS BS32 — BS32d 15A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32d/20 | BS BS32 — BS32d 20A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA | |
| BS32d/30 | BS BS32 — BS32d 30A 2P (MCB) | LS ELECTRIC | Frame: 30AF | Type: Branch circuit MCB (compact, economy) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Trip method: Thermal-Magnetic | Trip curve: Thermal-Magnetic standard | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V | Standard: KSC 8321 / — | Application: Industrial distribution panel (MCB) | Variant: BS32c=1.5kA, BS32d=2.5kA |
LS ELECTRIC Beyond X Residential MCB/RCBO BS32-K family. | Application: Residential distribution panel (MCB). | Frame: 32AF | Type: Branch circuit type (compact, economy) | Trip method: Thermal-Magnetic | Trip curve: D (6A: 10~50×In, 10~32A: 10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 6A, 10A, 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | Note: BS32c-K=1.5kA, BS32d-K=2.5kA | 10 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO BS32-K family. | Application: Residential distribution panel (MCB). | Frame: 32AF | Type: Branch circuit type (compact, economy) | Trip method: Thermal-Magnetic | Trip curve: D (6A: 10~50×In, 10~32A: 10~30×In) | Breaking capacity Icn: 1.5/2.5kA @ 220V AC | Ics: 100% Icn | Rated current (In): 6A, 10A, 16A, 20A, 32A | Pole: 2P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 8332 / IEC 60898 | Note: BS32c-K=1.5kA, BS32d-K=2.5kA | 10 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-BS32-K | [LS ELECTRIC] — BS32-K Beyond X Residential MCB/RCBO (Branch circuit type (compact, economy), 32AF MCB, 1.5/2.5kA @ 220V AC, 6~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE100Fb-100mA family. | Application: Industrial distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE100Fb-100mA family. | Application: Industrial distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE102Fb/60/100 | EBE Fb EBE100Fb-100mA — EBE102Fb 60A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 60A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE102Fb/75/100 | EBE Fb EBE100Fb-100mA — EBE102Fb 75A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 75A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE102Fb/100/100 | EBE Fb EBE100Fb-100mA — EBE102Fb 100A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 100A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/60/100 | EBE Fb EBE100Fb-100mA — EBE103Fb 60A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 60A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/75/100 | EBE Fb EBE100Fb-100mA — EBE103Fb 75A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 75A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/100/100 | EBE Fb EBE100Fb-100mA — EBE103Fb 100A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 100A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Operating time: ≤0.1s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE100Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE100Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 60A, 75A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE102Fb/60/30 | EBE Fb EBE100Fb-30mA — EBE102Fb 60A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 60A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE102Fb/75/30 | EBE Fb EBE100Fb-30mA — EBE102Fb 75A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 75A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE102Fb/100/30 | EBE Fb EBE100Fb-30mA — EBE102Fb 100A 2P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 100A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/60/30 | EBE Fb EBE100Fb-30mA — EBE103Fb 60A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 60A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/75/30 | EBE Fb EBE100Fb-30mA — EBE103Fb 75A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 75A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE103Fb/100/30 | EBE Fb EBE100Fb-30mA — EBE103Fb 100A 3P (RCBO) | LS ELECTRIC | Frame: 100AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 100A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Residential MCB/RCBO EBE100Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30, 100mA | Rated current (In): 63A, 80A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBE100Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 100AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30, 100mA | Rated current (In): 63A, 80A, 100A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBE100Fb-K | [LS ELECTRIC] — EBE100Fb-K Beyond X Residential MCB/RCBO (E-type RCBO (Hydraulic-Magnetic), 100AF RCBO, 5kA @ 220V AC / 2.5kA @ 380V AC, 30, 100mA, 63~100A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE30Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 3A, 5A, 10A, 15A, 20A, 30A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE30Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 3A, 5A, 10A, 15A, 20A, 30A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE32Fb/3/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 3A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 3A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE32Fb/5/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 5A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 5A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE32Fb/10/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 10A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE32Fb/15/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE32Fb/20/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE32Fb/30/30 | EBE Fb EBE30Fb-30mA — EBE32Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/3/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 3A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 3A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/5/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 5A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 5A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/10/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 10A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/15/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/20/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE33Fb/30/30 | EBE Fb EBE30Fb-30mA — EBE33Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE30Fb-50mA family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Rated current (In): 15A, 20A, 30A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 50mA: 15A and above only (3, 5, 10A not available) | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE30Fb-50mA family. | Application: Industrial distribution panel (RCBO). | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Rated current (In): 15A, 20A, 30A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 50mA: 15A and above only (3, 5, 10A not available) | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE32Fb/15/50 | EBE Fb EBE30Fb-50mA — EBE32Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) | |
| EBE32Fb/20/50 | EBE Fb EBE30Fb-50mA — EBE32Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) | |
| EBE32Fb/30/50 | EBE Fb EBE30Fb-50mA — EBE32Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) | |
| EBE33Fb/15/50 | EBE Fb EBE30Fb-50mA — EBE33Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) | |
| EBE33Fb/20/50 | EBE Fb EBE30Fb-50mA — EBE33Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) | |
| EBE33Fb/30/50 | EBE Fb EBE30Fb-50mA — EBE33Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 30AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only (3, 5, 10A not available) |
LS ELECTRIC Beyond X Residential MCB/RCBO EBE32Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBE32Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 32AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBE32Fb-K | [LS ELECTRIC] — EBE32Fb-K Beyond X Residential MCB/RCBO (E-type RCBO (Hydraulic-Magnetic), 32AF RCBO, 2.5kA @ 220V AC / 1.5kA @ 380V AC, 15, 30mA, 3~32A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE50Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE50Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE52Fb/5/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 5A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 5A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/10/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 10A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/15/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/20/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/30/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/40/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE52Fb/50/30 | EBE Fb EBE50Fb-30mA — EBE52Fb 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/5/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 5A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 5A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/10/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 10A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/15/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/20/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/30/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/40/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 40A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBE53Fb/50/30 | EBE Fb EBE50Fb-30mA — EBE53Fb 50A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE50Fb-50mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Rated current (In): 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 50mA: 15A and above only | 10 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBE50Fb-50mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Rated current (In): 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 50mA: 15A and above only | 10 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBE52Fb/15/50 | EBE Fb EBE50Fb-50mA — EBE52Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE52Fb/20/50 | EBE Fb EBE50Fb-50mA — EBE52Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE52Fb/30/50 | EBE Fb EBE50Fb-50mA — EBE52Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE52Fb/40/50 | EBE Fb EBE50Fb-50mA — EBE52Fb 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE52Fb/50/50 | EBE Fb EBE50Fb-50mA — EBE52Fb 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE53Fb/15/50 | EBE Fb EBE50Fb-50mA — EBE53Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE53Fb/20/50 | EBE Fb EBE50Fb-50mA — EBE53Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE53Fb/30/50 | EBE Fb EBE50Fb-50mA — EBE53Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE53Fb/40/50 | EBE Fb EBE50Fb-50mA — EBE53Fb 40A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only | |
| EBE53Fb/50/50 | EBE Fb EBE50Fb-50mA — EBE53Fb 50A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: E-type RCBO (Economy, Hydraulic-Magnetic) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 50mA | Operating time: ≤0.03s | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 50mA: 15A and above only |
LS ELECTRIC Beyond X Residential MCB/RCBO EBE50Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBE50Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: E-type RCBO (Hydraulic-Magnetic) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 2.5kA @ 220V AC / 1.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBE50Fb-K | [LS ELECTRIC] — EBE50Fb-K Beyond X Residential MCB/RCBO (E-type RCBO (Hydraulic-Magnetic), 50AF RCBO, 2.5kA @ 220V AC / 1.5kA @ 380V AC, 15, 30mA, 3~50A) | LS ELECTRIC |
LS ELECTRIC Metasol ELCB EBH125-A family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 28 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBH125-A family. Frame: 125AF | Type: H-type (High breaking capacity) | Breaking capacity Icu: 50kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 15A, 16A, 20A, 25A, 30A, 32A, 40A, 50A, 60A, 63A, 75A, 80A, 100A, 125A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 28 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBH103c/15A-A-TYPE | Metasol ELCB EBH125-A — 15A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/15A-A-TYPE | Metasol ELCB EBH125-A — 15A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 15A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/16A-A-TYPE | Metasol ELCB EBH125-A — 16A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/16A-A-TYPE | Metasol ELCB EBH125-A — 16A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/20A-A-TYPE | Metasol ELCB EBH125-A — 20A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/20A-A-TYPE | Metasol ELCB EBH125-A — 20A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/25A-A-TYPE | Metasol ELCB EBH125-A — 25A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/25A-A-TYPE | Metasol ELCB EBH125-A — 25A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/30A-A-TYPE | Metasol ELCB EBH125-A — 30A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/30A-A-TYPE | Metasol ELCB EBH125-A — 30A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 30A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/32A-A-TYPE | Metasol ELCB EBH125-A — 32A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/32A-A-TYPE | Metasol ELCB EBH125-A — 32A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/40A-A-TYPE | Metasol ELCB EBH125-A — 40A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/40A-A-TYPE | Metasol ELCB EBH125-A — 40A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/50A-A-TYPE | Metasol ELCB EBH125-A — 50A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/50A-A-TYPE | Metasol ELCB EBH125-A — 50A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/60A-A-TYPE | Metasol ELCB EBH125-A — 60A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/60A-A-TYPE | Metasol ELCB EBH125-A — 60A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/63A-A-TYPE | Metasol ELCB EBH125-A — 63A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/63A-A-TYPE | Metasol ELCB EBH125-A — 63A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/75A-A-TYPE | Metasol ELCB EBH125-A — 75A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/75A-A-TYPE | Metasol ELCB EBH125-A — 75A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 75A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/80A-A-TYPE | Metasol ELCB EBH125-A — 80A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/80A-A-TYPE | Metasol ELCB EBH125-A — 80A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/100A-A-TYPE | Metasol ELCB EBH125-A — 100A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/100A-A-TYPE | Metasol ELCB EBH125-A — 100A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH103c/125A-A-TYPE | Metasol ELCB EBH125-A — 125A 3P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 90×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBH104c/125A-A-TYPE | Metasol ELCB EBH125-A — 125A 4P, A Type | LS ELECTRIC | Frame: 125AF | Type: H-type (High breaking capacity) | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 120×155×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |