Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. Standard FM terminal. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. Standard FM terminal. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720-0.1K | FR-E720-0.1K Standard FM terminal, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.4 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: Standard FM terminal | |
| FR-E720-0.2K | FR-E720-0.2K Standard FM terminal, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.8 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: Standard FM terminal | |
| FR-E720-0.4K | FR-E720-0.4K Standard FM terminal, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.7 kg · Spec Type: Standard FM terminal | |
| FR-E720-0.75K | FR-E720-0.75K Standard FM terminal, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.0 kg · Spec Type: Standard FM terminal | |
| FR-E720-1.5K | FR-E720-1.5K Standard FM terminal, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 50% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Standard FM terminal | |
| FR-E720-2.2K | FR-E720-2.2K Standard FM terminal, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Standard FM terminal | |
| FR-E720-3.7K | FR-E720-3.7K Standard FM terminal, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.0 kVA · Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.7 kg · Spec Type: Standard FM terminal | |
| FR-E720-5.5K | FR-E720-5.5K Standard FM terminal, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: Standard FM terminal | |
| FR-E720-7.5K | FR-E720-7.5K Standard FM terminal, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.1 kVA · Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: Standard FM terminal | |
| FR-E720-11K | FR-E720-11K Standard FM terminal, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 18.7 kVA · Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: Standard FM terminal | |
| FR-E720-15K | FR-E720-15K Standard FM terminal, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.9 kVA · Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: Standard FM terminal |
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. CC-Link communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. CC-Link communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E740-0.4KNC | FR-E740-0.4KNC CC-Link communication, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: CC-Link communication | |
| FR-E740-0.75KNC | FR-E740-0.75KNC CC-Link communication, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: CC-Link communication | |
| FR-E740-1.5KNC | FR-E740-1.5KNC CC-Link communication, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.0 kVA · Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 50% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: CC-Link communication | |
| FR-E740-2.2KNC | FR-E740-2.2KNC CC-Link communication, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.6 kVA · Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: CC-Link communication | |
| FR-E740-3.7KNC | FR-E740-3.7KNC CC-Link communication, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.2 kVA · Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 9.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: CC-Link communication | |
| FR-E740-5.5KNC | FR-E740-5.5KNC CC-Link communication, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: CC-Link communication | |
| FR-E740-7.5KNC | FR-E740-7.5KNC CC-Link communication, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.0 kVA · Rated Current: 17 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: CC-Link communication | |
| FR-E740-11KNC | FR-E740-11KNC CC-Link communication, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: CC-Link communication | |
| FR-E740-15KNC | FR-E740-15KNC CC-Link communication, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.0 kVA · Rated Current: 30 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: CC-Link communication |
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. FL-remote communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. FL-remote communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E740-0.4KNF | FR-E740-0.4KNF FL-remote communication, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: FL-remote communication | |
| FR-E740-0.75KNF | FR-E740-0.75KNF FL-remote communication, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: FL-remote communication | |
| FR-E740-1.5KNF | FR-E740-1.5KNF FL-remote communication, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.0 kVA · Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 50% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: FL-remote communication | |
| FR-E740-2.2KNF | FR-E740-2.2KNF FL-remote communication, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.6 kVA · Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: FL-remote communication | |
| FR-E740-3.7KNF | FR-E740-3.7KNF FL-remote communication, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.2 kVA · Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 9.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: FL-remote communication | |
| FR-E740-5.5KNF | FR-E740-5.5KNF FL-remote communication, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: FL-remote communication | |
| FR-E740-7.5KNF | FR-E740-7.5KNF FL-remote communication, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.0 kVA · Rated Current: 17 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: FL-remote communication | |
| FR-E740-11KNF | FR-E740-11KNF FL-remote communication, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: FL-remote communication | |
| FR-E740-15KNF | FR-E740-15KNF FL-remote communication, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.0 kVA · Rated Current: 30 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: FL-remote communication |
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. Safety Stop compatible. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. Safety Stop compatible. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E740-0.4KSC | FR-E740-0.4KSC Safety Stop compatible, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Safety Stop compatible | |
| FR-E740-0.75KSC | FR-E740-0.75KSC Safety Stop compatible, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Safety Stop compatible | |
| FR-E740-1.5KSC | FR-E740-1.5KSC Safety Stop compatible, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.0 kVA · Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 50% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Safety Stop compatible | |
| FR-E740-2.2KSC | FR-E740-2.2KSC Safety Stop compatible, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.6 kVA · Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Safety Stop compatible | |
| FR-E740-3.7KSC | FR-E740-3.7KSC Safety Stop compatible, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.2 kVA · Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 9.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Safety Stop compatible | |
| FR-E740-5.5KSC | FR-E740-5.5KSC Safety Stop compatible, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: Safety Stop compatible | |
| FR-E740-7.5KSC | FR-E740-7.5KSC Safety Stop compatible, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.0 kVA · Rated Current: 17 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: Safety Stop compatible | |
| FR-E740-11KSC | FR-E740-11KSC Safety Stop compatible, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: Safety Stop compatible | |
| FR-E740-15KSC | FR-E740-15KSC Safety Stop compatible, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.0 kVA · Rated Current: 30 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: Safety Stop compatible |
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. Standard FM terminal. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 400V compact VFD, 0.4–15kW. Standard FM terminal. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E740-0.4K | FR-E740-0.4K Standard FM terminal, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 1.6 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Standard FM terminal | |
| FR-E740-0.75K | FR-E740-0.75K Standard FM terminal, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 2.6 A (2.2 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 100% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Standard FM terminal | |
| FR-E740-1.5K | FR-E740-1.5K Standard FM terminal, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.0 kVA · Rated Current: 4.0 A (3.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 50% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Standard FM terminal | |
| FR-E740-2.2K | FR-E740-2.2K Standard FM terminal, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.6 kVA · Rated Current: 6.0 A (5.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Standard FM terminal | |
| FR-E740-3.7K | FR-E740-3.7K Standard FM terminal, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.2 kVA · Rated Current: 9.5 A (8.7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 9.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.9 kg · Spec Type: Standard FM terminal | |
| FR-E740-5.5K | FR-E740-5.5K Standard FM terminal, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: Standard FM terminal | |
| FR-E740-7.5K | FR-E740-7.5K Standard FM terminal, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.0 kVA · Rated Current: 17 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 3.2 kg · Spec Type: Standard FM terminal | |
| FR-E740-11K | FR-E740-11K Standard FM terminal, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: Standard FM terminal | |
| FR-E740-15K | FR-E740-15K Standard FM terminal, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.0 kVA · Rated Current: 30 A · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 380-480V · Regenerative Torque: 20% · Input: 3-phase 380-480V 50/60Hz · Input Voltage Range: 325-528V · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 6.0 kg · Spec Type: Standard FM terminal |
Mitsubishi FREQROL-E700 single-phase 100V input compact VFD, 0.1–0.75kW, voltage-doubler 3-phase 200-230V output. Advanced magnetic flux vector control, 200%/0.5Hz starting torque. EMC directive not applicable.
Mitsubishi FREQROL-E700 single-phase 100V input compact VFD, 0.1–0.75kW, voltage-doubler 3-phase 200-230V output. Advanced magnetic flux vector control, 200%/0.5Hz starting torque. EMC directive not applicable.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E710W-0.1K | FR-E710W-0.1K Standard FM terminal, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-230V (Voltage-doubler) · Regenerative Torque: 150% · Input: Single-phase 100-115V 50/60Hz · Input Voltage Range: 90-132V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE (EMC directive not applicable for E710W) · Mass: 0.6 kg · Spec Type: Standard FM terminal | |
| FR-E710W-0.2K | FR-E710W-0.2K Standard FM terminal, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-230V (Voltage-doubler) · Regenerative Torque: 150% · Input: Single-phase 100-115V 50/60Hz · Input Voltage Range: 90-132V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE (EMC directive not applicable for E710W) · Mass: 0.7 kg · Spec Type: Standard FM terminal | |
| FR-E710W-0.4K | FR-E710W-0.4K Standard FM terminal, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3.0 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-230V (Voltage-doubler) · Regenerative Torque: 100% · Input: Single-phase 100-115V 50/60Hz · Input Voltage Range: 90-132V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE (EMC directive not applicable for E710W) · Mass: 0.9 kg · Spec Type: Standard FM terminal | |
| FR-E710W-0.75K | FR-E710W-0.75K Standard FM terminal, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5.0 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-230V (Voltage-doubler) · Regenerative Torque: 100% · Input: Single-phase 100-115V 50/60Hz · Input Voltage Range: 90-132V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE (EMC directive not applicable for E710W) · Mass: 1.5 kg · Spec Type: Standard FM terminal |
Mitsubishi FREQROL-E700 single-phase 200V input compact VFD, 0.1–2.2kW, 3-phase 200-240V output. Safety Stop compatible. Advanced magnetic flux vector control, 200%/0.5Hz starting torque (≤3.7K).
Mitsubishi FREQROL-E700 single-phase 200V input compact VFD, 0.1–2.2kW, 3-phase 200-240V output. Safety Stop compatible. Advanced magnetic flux vector control, 200%/0.5Hz starting torque (≤3.7K).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720S-0.1KSC | FR-E720S-0.1KSC Safety Stop compatible, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 150% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.6 kg · Spec Type: Safety Stop compatible | |
| FR-E720S-0.2KSC | FR-E720S-0.2KSC Safety Stop compatible, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 150% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.6 kg · Spec Type: Safety Stop compatible | |
| FR-E720S-0.4KSC | FR-E720S-0.4KSC Safety Stop compatible, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3.0 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 100% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.9 kg · Spec Type: Safety Stop compatible | |
| FR-E720S-0.75KSC | FR-E720S-0.75KSC Safety Stop compatible, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5.0 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 100% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Safety Stop compatible | |
| FR-E720S-1.5KSC | FR-E720S-1.5KSC Safety Stop compatible, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8.0 A (7.0 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 50% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.0 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.5 kg · Spec Type: Safety Stop compatible | |
| FR-E720S-2.2KSC | FR-E720S-2.2KSC Safety Stop compatible, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11.0 A (10.0 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 20% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.2 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 2.0 kg · Spec Type: Safety Stop compatible |
Mitsubishi FREQROL-E700 single-phase 200V input compact VFD, 0.1–2.2kW, 3-phase 200-240V output. Standard FM terminal. Advanced magnetic flux vector control, 200%/0.5Hz starting torque (≤3.7K).
Mitsubishi FREQROL-E700 single-phase 200V input compact VFD, 0.1–2.2kW, 3-phase 200-240V output. Standard FM terminal. Advanced magnetic flux vector control, 200%/0.5Hz starting torque (≤3.7K).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720S-0.1K | FR-E720S-0.1K Standard FM terminal, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 150% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.6 kg · Spec Type: Standard FM terminal | |
| FR-E720S-0.2K | FR-E720S-0.2K Standard FM terminal, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 150% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 0.9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.6 kg · Spec Type: Standard FM terminal | |
| FR-E720S-0.4K | FR-E720S-0.4K Standard FM terminal, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3.0 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 100% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 0.9 kg · Spec Type: Standard FM terminal | |
| FR-E720S-0.75K | FR-E720S-0.75K Standard FM terminal, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5.0 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 100% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Standard FM terminal | |
| FR-E720S-1.5K | FR-E720S-1.5K Standard FM terminal, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8.0 A (7.0 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 50% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 4.0 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 1.5 kg · Spec Type: Standard FM terminal | |
| FR-E720S-2.2K | FR-E720S-2.2K Standard FM terminal, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11.0 A (10.0 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V (Doubled output) · Regenerative Torque: 20% · Input: Single-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V · Frequency Tolerance: ±5% · Power Supply Capacity: 5.2 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: — · Standards: UL, cUL, CE · Mass: 2.0 kg · Spec Type: Standard FM terminal |