Circuit Breakers
LS ELECTRIC Beyond X Residential MCB/RCBO EBS50c-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: S-type (RCBO, 4-pole only) | Trip method: Thermal-Magnetic (TM) + RCD | Trip curve: D (16~40A) / C,D (50A) | Breaking capacity Icn: 20kA @ 380V AC | Ics: 50% Icn | Sensitivity (I△n): 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A | Pole: 4P | Mounting: Screw | Uimp: 6kV | Standard: KS C 4621 / IEC 61009 | 5 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBS50c-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: S-type (RCBO, 4-pole only) | Trip method: Thermal-Magnetic (TM) + RCD | Trip curve: D (16~40A) / C,D (50A) | Breaking capacity Icn: 20kA @ 380V AC | Ics: 50% Icn | Sensitivity (I△n): 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A | Pole: 4P | Mounting: Screw | Uimp: 6kV | Standard: KS C 4621 / IEC 61009 | 5 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBS50c-K | [LS ELECTRIC] — EBS50c-K Beyond X Residential MCB/RCBO (S-type (RCBO, 4-pole only), 50AF RCBO, 20kA @ 380V AC, 30mA, 16~50A) | LS ELECTRIC |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-100mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 100mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 100mA available in 3-pole only | 7 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-100mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 100mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Note: 100mA available in 3-pole only | 7 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS53Fb/5/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 5A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 5A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/10/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 10A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/15/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/20/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/30/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/40/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 40A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only | |
| EBS53Fb/50/100 | EBS Fb EBS50Fb-100mA — EBS53Fb 50A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 100mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 220/380V | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | Note: 100mA available in 3-pole only |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-15mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-15mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS52Fb/5/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 5A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 5A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/10/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 10A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/15/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/20/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/30/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/40/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/50/15 | EBS Fb EBS50Fb-15mA — EBS52Fb 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/5/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 5A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 5A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/10/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 10A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/15/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/20/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/30/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/40/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 40A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/50/15 | EBS Fb EBS50Fb-15mA — EBS53Fb 50A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 15mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Industrial Distribution Panel MCB/RCBO EBS50Fb-30mA family. | Application: Industrial distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 30mA | Rated current (In): 5A, 10A, 15A, 20A, 30A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN rail | Uimp: 4kV | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | 14 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS52Fb/5/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 5A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 5A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/10/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 10A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 10A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/15/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 15A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 15A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/20/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 20A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 20A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/30/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 30A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 30A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/40/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 40A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 40A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS52Fb/50/30 | EBS Fb EBS50Fb-30mA — EBS52Fb 50A 2P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 50A | Pole: 2P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/5/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 5A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 5A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/10/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 10A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 10A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/15/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 15A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 15A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/20/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 20A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 20A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/30/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 30A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 30A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/40/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 40A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 40A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) | |
| EBS53Fb/50/30 | EBS Fb EBS50Fb-30mA — EBS53Fb 50A 3P (RCBO) | LS ELECTRIC | Frame: 50AF | Type: S-type RCBO (Standard, Hydraulic-Magnetic, High breaking) | Rated current (In): 50A | Pole: 3P | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Trip method: Hydraulic-Magnetic + RCD | Trip curve: (7~15)×In | Sensitivity (I△n): 30mA | Uimp: 4kV | Mounting: Screw or DIN rail | Voltage: AC 110/220V (2P) / 220/380V (3P) | Standard: KSC 8321 / KSC 4613 / IEC 60947-2 | Application: Industrial distribution panel (RCBO) |
LS ELECTRIC Beyond X Residential MCB/RCBO EBS50Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 16 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBS50Fb-K family. | Application: Residential distribution panel (RCBO). | Frame: 50AF | Type: S-type RCBO (Hydraulic-Magnetic, High breaking) | Trip method: Hydraulic-Magnetic + RCD | Trip curve: C (5~10×In) / D (10~20×In) | Breaking capacity Icn: 5kA @ 220V AC / 2.5kA @ 380V AC | Ics: 100% Icn | Sensitivity (I△n): 15, 30mA | Rated current (In): 3A, 6A, 10A, 16A, 20A, 32A, 40A, 50A | Pole: 2P / 3P | Mounting: Screw or DIN-Rail | Uimp: 4kV | Standard: KS C 4621 / IEC 61009 | 16 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBS50Fb-K | [LS ELECTRIC] — EBS50Fb-K Beyond X Residential MCB/RCBO (S-type RCBO (Hydraulic-Magnetic, High breaking), 50AF RCBO, 5kA @ 220V AC / 2.5kA @ 380V AC, 15, 30mA, 3~50A) | LS ELECTRIC |
[LS ELECTRIC] — EBS60-A Metasol ELCB (S-type (Standard breaking capacity), 18kA @ 415V, A Type, 60A)
▶LS ELECTRIC Metasol ELCB EBS60-A family. Frame: 60AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 60A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBS60-A family. Frame: 60AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: A Type (AC + Pulsating DC leakage current detection) | Rated current (In): 60A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS63c/60A-A-TYPE | Metasol ELCB EBS60-A — 60A 3P, A Type | LS ELECTRIC | Frame: 60AF | Type: S-type (Standard breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers | |
| EBS64c/60A-A-TYPE | Metasol ELCB EBS60-A — 60A 4P, A Type | LS ELECTRIC | Frame: 60AF | Type: S-type (Standard breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: A Type | Detection: AC + Pulsating DC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: EV chargers, Inverters (Single-phase UPS, PV, Motor drive), Rectifiers |
LS ELECTRIC Metasol ELCB EBS60-AC family. Frame: 60AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 60A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBS60-AC family. Frame: 60AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 18kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 60A | Pole: 3P / 4P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS63c/60A | Metasol ELCB EBS60-AC — 60A 3P, AC Type | LS ELECTRIC | Frame: 60AF | Type: S-type (Standard breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 75×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBS64c/60A | Metasol ELCB EBS60-AC — 60A 4P, AC Type | LS ELECTRIC | Frame: 60AF | Type: S-type (Standard breaking capacity) | Rated current (In): 60A | Breaking capacity Icu: 18kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 4P | Dimensions (W×H×D): 100×130×60 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Beyond X Residential MCB/RCBO EBS60c-K family. | Application: Residential distribution panel (RCBO). | Frame: 60AF | Type: S-type (RCBO, 4-pole only) | Trip method: Thermal-Magnetic (TM) + RCD | Trip curve: D (16~40A) / C,D (50,63A) | Breaking capacity Icn: 20kA @ 380V AC | Ics: 50% Icn | Sensitivity (I△n): 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A, 63A | Pole: 4P | Mounting: Screw | Uimp: 6kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
LS ELECTRIC Beyond X Residential MCB/RCBO EBS60c-K family. | Application: Residential distribution panel (RCBO). | Frame: 60AF | Type: S-type (RCBO, 4-pole only) | Trip method: Thermal-Magnetic (TM) + RCD | Trip curve: D (16~40A) / C,D (50,63A) | Breaking capacity Icn: 20kA @ 380V AC | Ics: 50% Icn | Sensitivity (I△n): 30mA | Rated current (In): 16A, 20A, 32A, 40A, 50A, 63A | Pole: 4P | Mounting: Screw | Uimp: 6kV | Standard: KS C 4621 / IEC 61009 | 6 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | |
|---|---|---|---|
| LSE-EBS60c-K | [LS ELECTRIC] — EBS60c-K Beyond X Residential MCB/RCBO (S-type (RCBO, 4-pole only), 60AF RCBO, 20kA @ 380V AC, 30mA, 16~63A) | LS ELECTRIC |
LS ELECTRIC Metasol ELCB EBS630-AC family. Frame: 630AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBS630-AC family. Frame: 630AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 500A, 630A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS603c/500A | Metasol ELCB EBS630-AC — 500A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: S-type (Standard breaking capacity) | Rated current (In): 500A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBS603c/630A | Metasol ELCB EBS630-AC — 630A 3P, AC Type | LS ELECTRIC | Frame: 630AF | Type: S-type (Standard breaking capacity) | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Metasol ELCB EBS800-AC family. Frame: 800AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 700A, 800A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
LS ELECTRIC Metasol ELCB EBS800-AC family. Frame: 800AF | Type: S-type (Standard breaking capacity) | Breaking capacity Icu: 65kA @ 415V AC | Leakage type: AC Type (AC leakage current detection) | Rated current (In): 700A, 800A | Pole: 3P | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV (8kV for 30AF) | Application: General load, Lighting, Heater, Passive electronic equipment | 2 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EBS803c/700A | Metasol ELCB EBS800-AC — 700A 3P, AC Type | LS ELECTRIC | Frame: 800AF | Type: S-type (Standard breaking capacity) | Rated current (In): 700A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment | |
| EBS803c/800A | Metasol ELCB EBS800-AC — 800A 3P, AC Type | LS ELECTRIC | Frame: 800AF | Type: S-type (Standard breaking capacity) | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC AC | Leakage type: AC Type | Detection: AC leakage current detection | Sensitivity (rated I△n): 30mA / 100mA / 100·200·500mA (selectable) | Operating time: ≤0.1s (high-speed type) | Pole: 3P | Dimensions (W×H×D): 210×280×109 mm | Standard: KS C 4613 / IEC 60947-2 | Ui 1000V | Uimp 6kV | Application: General load, Lighting, Heater, Passive electronic equipment |
LS ELECTRIC Susol MCCB TD100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100H-FTU100-16A-2P | Susol MCCB TD100H-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-16A-3P | Susol MCCB TD100H-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-16A-4PL | Susol MCCB TD100H-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-2P | Susol MCCB TD100H-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-3P | Susol MCCB TD100H-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-20A-4PL | Susol MCCB TD100H-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-2P | Susol MCCB TD100H-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-3P | Susol MCCB TD100H-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-25A-4PL | Susol MCCB TD100H-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-2P | Susol MCCB TD100H-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-3P | Susol MCCB TD100H-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-32A-4PL | Susol MCCB TD100H-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-2P | Susol MCCB TD100H-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-3P | Susol MCCB TD100H-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-40A-4PL | Susol MCCB TD100H-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-2P | Susol MCCB TD100H-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-3P | Susol MCCB TD100H-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-50A-4PL | Susol MCCB TD100H-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-2P | Susol MCCB TD100H-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-3P | Susol MCCB TD100H-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-63A-4PL | Susol MCCB TD100H-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-2P | Susol MCCB TD100H-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-3P | Susol MCCB TD100H-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-80A-4PL | Susol MCCB TD100H-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-2P | Susol MCCB TD100H-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-3P | Susol MCCB TD100H-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100H-FTU100-100A-4PL | Susol MCCB TD100H-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100L-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100L-FTU100-16A-2P | Susol MCCB TD100L-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-16A-3P | Susol MCCB TD100L-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-16A-4PL | Susol MCCB TD100L-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-2P | Susol MCCB TD100L-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-3P | Susol MCCB TD100L-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-20A-4PL | Susol MCCB TD100L-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-2P | Susol MCCB TD100L-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-3P | Susol MCCB TD100L-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-25A-4PL | Susol MCCB TD100L-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-2P | Susol MCCB TD100L-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-3P | Susol MCCB TD100L-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-32A-4PL | Susol MCCB TD100L-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-2P | Susol MCCB TD100L-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-3P | Susol MCCB TD100L-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-40A-4PL | Susol MCCB TD100L-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-2P | Susol MCCB TD100L-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-3P | Susol MCCB TD100L-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-50A-4PL | Susol MCCB TD100L-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-2P | Susol MCCB TD100L-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-3P | Susol MCCB TD100L-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-63A-4PL | Susol MCCB TD100L-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-2P | Susol MCCB TD100L-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-3P | Susol MCCB TD100L-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-80A-4PL | Susol MCCB TD100L-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-2P | Susol MCCB TD100L-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-3P | Susol MCCB TD100L-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100L-FTU100-100A-4PL | Susol MCCB TD100L-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD100N-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 27 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD100N-FTU100-16A-2P | Susol MCCB TD100N-FTU — 16A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-16A-3P | Susol MCCB TD100N-FTU — 16A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-16A-4PL | Susol MCCB TD100N-FTU — 16A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 16A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-2P | Susol MCCB TD100N-FTU — 20A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-3P | Susol MCCB TD100N-FTU — 20A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-20A-4PL | Susol MCCB TD100N-FTU — 20A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 20A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-2P | Susol MCCB TD100N-FTU — 25A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-3P | Susol MCCB TD100N-FTU — 25A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-25A-4PL | Susol MCCB TD100N-FTU — 25A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 25A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-2P | Susol MCCB TD100N-FTU — 32A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-3P | Susol MCCB TD100N-FTU — 32A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-32A-4PL | Susol MCCB TD100N-FTU — 32A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 32A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-2P | Susol MCCB TD100N-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-3P | Susol MCCB TD100N-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-40A-4PL | Susol MCCB TD100N-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-2P | Susol MCCB TD100N-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-3P | Susol MCCB TD100N-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-50A-4PL | Susol MCCB TD100N-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-2P | Susol MCCB TD100N-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-3P | Susol MCCB TD100N-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-63A-4PL | Susol MCCB TD100N-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-2P | Susol MCCB TD100N-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-3P | Susol MCCB TD100N-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-80A-4PL | Susol MCCB TD100N-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-2P | Susol MCCB TD100N-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-3P | Susol MCCB TD100N-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD100N-FTU100-100A-4PL | Susol MCCB TD100N-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160H-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160H-FTU160-100A-2P | Susol MCCB TD160H-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-100A-3P | Susol MCCB TD160H-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-100A-4PL | Susol MCCB TD160H-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-2P | Susol MCCB TD160H-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-3P | Susol MCCB TD160H-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-125A-4PL | Susol MCCB TD160H-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-2P | Susol MCCB TD160H-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-3P | Susol MCCB TD160H-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160H-FTU160-160A-4PL | Susol MCCB TD160H-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160L-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160L-FTU160-100A-2P | Susol MCCB TD160L-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-100A-3P | Susol MCCB TD160L-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-100A-4PL | Susol MCCB TD160L-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-2P | Susol MCCB TD160L-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-3P | Susol MCCB TD160L-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-125A-4PL | Susol MCCB TD160L-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-2P | Susol MCCB TD160L-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-3P | Susol MCCB TD160L-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160L-FTU160-160A-4PL | Susol MCCB TD160L-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TD160N-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TD160N-FTU family. Frame: 160AF | Breaking capacity Icu @ 415V AC: 50kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 100A, 125A, 160A | Pole: 2P / 3P / 4P (N-arrangement L) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 9 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TD160N-FTU160-100A-2P | Susol MCCB TD160N-FTU — 100A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-100A-3P | Susol MCCB TD160N-FTU — 100A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-100A-4PL | Susol MCCB TD160N-FTU — 100A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 100A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-2P | Susol MCCB TD160N-FTU — 125A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-3P | Susol MCCB TD160N-FTU — 125A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-125A-4PL | Susol MCCB TD160N-FTU — 125A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 125A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-2P | Susol MCCB TD160N-FTU — 160A FTU160, 2-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-3P | Susol MCCB TD160N-FTU — 160A FTU160, 3-pole | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 90×140×86 mm | Weight: 1.5 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TD160N-FTU160-160A-4PL | Susol MCCB TD160N-FTU — 160A FTU160, 4-pole (L) | LS ELECTRIC | Frame: 160AF | Rated current (In): 160A | Breaking capacity Icu: 50kA @ 415V AC | Trip unit: FTU160 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 120×140×86 mm | Weight: 1.8 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100H-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100H-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100H-ETS100-40A-2P | Susol MCCB TS100H-ETS — 40A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-3P | Susol MCCB TS100H-ETS — 40A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-4PL | Susol MCCB TS100H-ETS — 40A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-40A-4PR | Susol MCCB TS100H-ETS — 40A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-2P | Susol MCCB TS100H-ETS — 80A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-3P | Susol MCCB TS100H-ETS — 80A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-4PL | Susol MCCB TS100H-ETS — 80A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-80A-4PR | Susol MCCB TS100H-ETS — 80A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-2P | Susol MCCB TS100H-ETS — 100A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-3P | Susol MCCB TS100H-ETS — 100A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-4PL | Susol MCCB TS100H-ETS — 100A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-ETS100-100A-4PR | Susol MCCB TS100H-ETS — 100A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100H-FTU family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 85kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 40A, 50A, 63A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 20 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100H-FTU100-40A-2P | Susol MCCB TS100H-FTU — 40A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-3P | Susol MCCB TS100H-FTU — 40A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-4PL | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-40A-4PR | Susol MCCB TS100H-FTU — 40A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-2P | Susol MCCB TS100H-FTU — 50A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-3P | Susol MCCB TS100H-FTU — 50A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-4PL | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-50A-4PR | Susol MCCB TS100H-FTU — 50A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 50A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-2P | Susol MCCB TS100H-FTU — 63A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-3P | Susol MCCB TS100H-FTU — 63A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-4PL | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-63A-4PR | Susol MCCB TS100H-FTU — 63A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 63A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-2P | Susol MCCB TS100H-FTU — 80A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-3P | Susol MCCB TS100H-FTU — 80A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-4PL | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-80A-4PR | Susol MCCB TS100H-FTU — 80A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-2P | Susol MCCB TS100H-FTU — 100A FTU100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-3P | Susol MCCB TS100H-FTU — 100A FTU100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-4PL | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100H-FTU100-100A-4PR | Susol MCCB TS100H-FTU — 100A FTU100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: FTU100 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS100Hi family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS100Hi family. Frame: 100AF | Rated current: 40A, 100A | Icu @ 415V AC: 85kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100Hi-ETSi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-3P | Susol Smart MCCB TS100Hi — 40A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-4PL | Susol Smart MCCB TS100Hi — 40A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-40A-4PR | Susol Smart MCCB TS100Hi — 40A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETSi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETSi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETMi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETMi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETHi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETHi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-3P | Susol Smart MCCB TS100Hi — 100A ETLi, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-4PL | Susol Smart MCCB TS100Hi — 100A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100Hi-ETLi-100A-4PR | Susol Smart MCCB TS100Hi — 100A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 85kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 140×160×86 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS100L-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS100L-ETS family. Frame: 100AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 40A, 80A, 100A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS100L-ETS100-40A-2P | Susol MCCB TS100L-ETS — 40A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-3P | Susol MCCB TS100L-ETS — 40A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-4PL | Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-40A-4PR | Susol MCCB TS100L-ETS — 40A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 40A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-2P | Susol MCCB TS100L-ETS — 80A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-3P | Susol MCCB TS100L-ETS — 80A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-4PL | Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-80A-4PR | Susol MCCB TS100L-ETS — 80A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 80A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-2P | Susol MCCB TS100L-ETS — 100A ETS100, 2-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-3P | Susol MCCB TS100L-ETS — 100A ETS100, 3-pole | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 105×160×86 mm | Weight: 2.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-4PL | Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (L) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS100L-ETS100-100A-4PR | Susol MCCB TS100L-ETS — 100A ETS100, 4-pole (R) | LS ELECTRIC | Frame: 100AF | Rated current (In): 100A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS100 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 140×160×86 mm | Weight: 2.6 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |