Mitsubishi FREQROL FR-A840 high-performance general-purpose inverter (VFD), Three-Phase 400V, ND-rated 0.4-280kW. Real/PM sensorless vector control, four selectable rating modes (SLD/LD/ND/HD), FM/CA output terminal; 150% 60s / 200% 3s ND overload.
Mitsubishi FREQROL FR-A840 high-performance general-purpose inverter (VFD), Three-Phase 400V, ND-rated 0.4-280kW. Real/PM sensorless vector control, four selectable rating modes (SLD/LD/ND/HD), FM/CA output terminal; 150% 60s / 200% 3s ND overload.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A840-0.4K | FR-A840 three-phase 400v high-performance inverter, ND 0.4kW (00023), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (SLD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00023 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-0.75K | FR-A840 three-phase 400v high-performance inverter, ND 0.75kW (00038), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (SLD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00038 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-1.5K | FR-A840 three-phase 400v high-performance inverter, ND 1.5kW (00052), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (SLD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00052 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-2.2K | FR-A840 three-phase 400v high-performance inverter, ND 2.2kW (00083), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (SLD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00083 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-3.7K | FR-A840 three-phase 400v high-performance inverter, ND 3.7kW (00126), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (SLD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00126 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-5.5K | FR-A840 three-phase 400v high-performance inverter, ND 5.5kW (00170), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (SLD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00170 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-7.5K | FR-A840 three-phase 400v high-performance inverter, ND 7.5kW (00250), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (SLD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00250 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-11K | FR-A840 three-phase 400v high-performance inverter, ND 11kW (00310), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (SLD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00310 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-15K | FR-A840 three-phase 400v high-performance inverter, ND 15kW (00380), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (SLD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00380 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-18.5K | FR-A840 three-phase 400v high-performance inverter, ND 18.5kW (00470), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (SLD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00470 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-22K | FR-A840 three-phase 400v high-performance inverter, ND 22kW (00620), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (SLD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00620 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-30K | FR-A840 three-phase 400v high-performance inverter, ND 30kW (00770), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (SLD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00770 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 23 kg | |
| FR-A840-37K | FR-A840 three-phase 400v high-performance inverter, ND 37kW (00930), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (SLD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00930 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-45K | FR-A840 three-phase 400v high-performance inverter, ND 45kW (01160), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (SLD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01160 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-55K | FR-A840 three-phase 400v high-performance inverter, ND 55kW (01800), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (SLD): 75/90 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01800 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 43 kg | |
| FR-A840-75K | FR-A840 three-phase 400v high-performance inverter, ND 75kW (02160), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (SLD): 110 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02160 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 52 kg | |
| FR-A840-90K | FR-A840 three-phase 400v high-performance inverter, ND 90kW (02600), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (SLD): 132 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02600 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 55 kg | |
| FR-A840-110K | FR-A840 three-phase 400v high-performance inverter, ND 110kW (03250), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (SLD): 160 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03250 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 71 kg | |
| FR-A840-132K | FR-A840 three-phase 400v high-performance inverter, ND 132kW (03610), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (SLD): 185 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03610 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 78 kg | |
| FR-A840-160K | FR-A840 three-phase 400v high-performance inverter, ND 160kW (04320), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 160 kW · Max Applied Motor (SLD): 220 kW · Rated Output Current (ND): 325 A · Rated Capacity (ND): 248 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04320 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-185K | FR-A840 three-phase 400v high-performance inverter, ND 185kW (04810), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 185 kW · Max Applied Motor (SLD): 250 kW · Rated Output Current (ND): 361 A · Rated Capacity (ND): 275 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04810 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-220K | FR-A840 three-phase 400v high-performance inverter, ND 220kW (05470), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 220 kW · Max Applied Motor (SLD): 280 kW · Rated Output Current (ND): 432 A · Rated Capacity (ND): 329 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 05470 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-250K | FR-A840 three-phase 400v high-performance inverter, ND 250kW (06100), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 250 kW · Max Applied Motor (SLD): 315 kW · Rated Output Current (ND): 481 A · Rated Capacity (ND): 367 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06100 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-280K | FR-A840 three-phase 400v high-performance inverter, ND 280kW (06830), sensorless vector | MITSUBISHI ELECTRIC | Applied Motor (ND): 280 kW · Max Applied Motor (SLD): 355 kW · Rated Output Current (ND): 547 A · Rated Capacity (ND): 417 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06830 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg |
Mitsubishi FREQROL FR-A840-E high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in ethernet. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
Mitsubishi FREQROL FR-A840-E high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in ethernet. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A840-0.4K-E | FR-A840-E three-phase 400v inverter, ND 0.4kW (00023), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (SLD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00023 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-0.75K-E | FR-A840-E three-phase 400v inverter, ND 0.75kW (00038), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (SLD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00038 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-1.5K-E | FR-A840-E three-phase 400v inverter, ND 1.5kW (00052), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (SLD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00052 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-2.2K-E | FR-A840-E three-phase 400v inverter, ND 2.2kW (00083), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (SLD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00083 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-3.7K-E | FR-A840-E three-phase 400v inverter, ND 3.7kW (00126), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (SLD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00126 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-5.5K-E | FR-A840-E three-phase 400v inverter, ND 5.5kW (00170), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (SLD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00170 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-7.5K-E | FR-A840-E three-phase 400v inverter, ND 7.5kW (00250), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (SLD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00250 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-11K-E | FR-A840-E three-phase 400v inverter, ND 11kW (00310), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (SLD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00310 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-15K-E | FR-A840-E three-phase 400v inverter, ND 15kW (00380), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (SLD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00380 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-18.5K-E | FR-A840-E three-phase 400v inverter, ND 18.5kW (00470), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (SLD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00470 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-22K-E | FR-A840-E three-phase 400v inverter, ND 22kW (00620), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (SLD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00620 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-30K-E | FR-A840-E three-phase 400v inverter, ND 30kW (00770), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (SLD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00770 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 23 kg | |
| FR-A840-37K-E | FR-A840-E three-phase 400v inverter, ND 37kW (00930), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (SLD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00930 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-45K-E | FR-A840-E three-phase 400v inverter, ND 45kW (01160), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (SLD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01160 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-55K-E | FR-A840-E three-phase 400v inverter, ND 55kW (01800), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (SLD): 75/90 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01800 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 43 kg | |
| FR-A840-75K-E | FR-A840-E three-phase 400v inverter, ND 75kW (02160), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (SLD): 110 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02160 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 52 kg | |
| FR-A840-90K-E | FR-A840-E three-phase 400v inverter, ND 90kW (02600), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (SLD): 132 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02600 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 55 kg | |
| FR-A840-110K-E | FR-A840-E three-phase 400v inverter, ND 110kW (03250), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (SLD): 160 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03250 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 71 kg | |
| FR-A840-132K-E | FR-A840-E three-phase 400v inverter, ND 132kW (03610), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (SLD): 185 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03610 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 78 kg | |
| FR-A840-160K-E | FR-A840-E three-phase 400v inverter, ND 160kW (04320), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 160 kW · Max Applied Motor (SLD): 220 kW · Rated Output Current (ND): 325 A · Rated Capacity (ND): 248 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04320 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-185K-E | FR-A840-E three-phase 400v inverter, ND 185kW (04810), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 185 kW · Max Applied Motor (SLD): 250 kW · Rated Output Current (ND): 361 A · Rated Capacity (ND): 275 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04810 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-220K-E | FR-A840-E three-phase 400v inverter, ND 220kW (05470), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 220 kW · Max Applied Motor (SLD): 280 kW · Rated Output Current (ND): 432 A · Rated Capacity (ND): 329 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 05470 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-250K-E | FR-A840-E three-phase 400v inverter, ND 250kW (06100), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 250 kW · Max Applied Motor (SLD): 315 kW · Rated Output Current (ND): 481 A · Rated Capacity (ND): 367 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06100 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-280K-E | FR-A840-E three-phase 400v inverter, ND 280kW (06830), built-in ethernet | MITSUBISHI ELECTRIC | Applied Motor (ND): 280 kW · Max Applied Motor (SLD): 355 kW · Rated Output Current (ND): 547 A · Rated Capacity (ND): 417 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06830 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg |
Mitsubishi FREQROL FR-A840-GF high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie field network. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
Mitsubishi FREQROL FR-A840-GF high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie field network. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A840-0.4K-GF | FR-A840-GF three-phase 400v inverter, ND 0.4kW (00023), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (SLD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00023 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-0.75K-GF | FR-A840-GF three-phase 400v inverter, ND 0.75kW (00038), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (SLD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00038 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-1.5K-GF | FR-A840-GF three-phase 400v inverter, ND 1.5kW (00052), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (SLD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00052 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-2.2K-GF | FR-A840-GF three-phase 400v inverter, ND 2.2kW (00083), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (SLD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00083 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-3.7K-GF | FR-A840-GF three-phase 400v inverter, ND 3.7kW (00126), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (SLD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00126 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-5.5K-GF | FR-A840-GF three-phase 400v inverter, ND 5.5kW (00170), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (SLD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00170 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-7.5K-GF | FR-A840-GF three-phase 400v inverter, ND 7.5kW (00250), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (SLD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00250 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-11K-GF | FR-A840-GF three-phase 400v inverter, ND 11kW (00310), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (SLD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00310 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-15K-GF | FR-A840-GF three-phase 400v inverter, ND 15kW (00380), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (SLD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00380 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-18.5K-GF | FR-A840-GF three-phase 400v inverter, ND 18.5kW (00470), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (SLD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00470 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-22K-GF | FR-A840-GF three-phase 400v inverter, ND 22kW (00620), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (SLD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00620 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-30K-GF | FR-A840-GF three-phase 400v inverter, ND 30kW (00770), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (SLD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00770 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 23 kg | |
| FR-A840-37K-GF | FR-A840-GF three-phase 400v inverter, ND 37kW (00930), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (SLD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00930 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-45K-GF | FR-A840-GF three-phase 400v inverter, ND 45kW (01160), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (SLD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01160 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-55K-GF | FR-A840-GF three-phase 400v inverter, ND 55kW (01800), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (SLD): 75/90 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01800 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 43 kg | |
| FR-A840-75K-GF | FR-A840-GF three-phase 400v inverter, ND 75kW (02160), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (SLD): 110 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02160 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 52 kg | |
| FR-A840-90K-GF | FR-A840-GF three-phase 400v inverter, ND 90kW (02600), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (SLD): 132 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02600 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 55 kg | |
| FR-A840-110K-GF | FR-A840-GF three-phase 400v inverter, ND 110kW (03250), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (SLD): 160 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03250 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 71 kg | |
| FR-A840-132K-GF | FR-A840-GF three-phase 400v inverter, ND 132kW (03610), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (SLD): 185 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03610 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 78 kg | |
| FR-A840-160K-GF | FR-A840-GF three-phase 400v inverter, ND 160kW (04320), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 160 kW · Max Applied Motor (SLD): 220 kW · Rated Output Current (ND): 325 A · Rated Capacity (ND): 248 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04320 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-185K-GF | FR-A840-GF three-phase 400v inverter, ND 185kW (04810), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 185 kW · Max Applied Motor (SLD): 250 kW · Rated Output Current (ND): 361 A · Rated Capacity (ND): 275 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04810 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-220K-GF | FR-A840-GF three-phase 400v inverter, ND 220kW (05470), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 220 kW · Max Applied Motor (SLD): 280 kW · Rated Output Current (ND): 432 A · Rated Capacity (ND): 329 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 05470 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-250K-GF | FR-A840-GF three-phase 400v inverter, ND 250kW (06100), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 250 kW · Max Applied Motor (SLD): 315 kW · Rated Output Current (ND): 481 A · Rated Capacity (ND): 367 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06100 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-280K-GF | FR-A840-GF three-phase 400v inverter, ND 280kW (06830), built-in cc-link ie field network | MITSUBISHI ELECTRIC | Applied Motor (ND): 280 kW · Max Applied Motor (SLD): 355 kW · Rated Output Current (ND): 547 A · Rated Capacity (ND): 417 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06830 · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg |
Mitsubishi FREQROL FR-A840-GN high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie tsn. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
Mitsubishi FREQROL FR-A840-GN high-performance inverter (VFD), Three-Phase 400V, ND 0.4-280kW, with built-in cc-link ie tsn. Real/PM sensorless vector, SLD/LD/ND/HD selectable rating, FM/CA output; same ratings as standard FR-A840.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A840-0.4K-GN | FR-A840-GN three-phase 400v inverter, ND 0.4kW (00023), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (SLD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00023 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-0.75K-GN | FR-A840-GN three-phase 400v inverter, ND 0.75kW (00038), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (SLD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00038 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-1.5K-GN | FR-A840-GN three-phase 400v inverter, ND 1.5kW (00052), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (SLD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00052 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self-cooling · Weight: 3.0 kg | |
| FR-A840-2.2K-GN | FR-A840-GN three-phase 400v inverter, ND 2.2kW (00083), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (SLD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00083 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-3.7K-GN | FR-A840-GN three-phase 400v inverter, ND 3.7kW (00126), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (SLD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00126 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 3.4 kg | |
| FR-A840-5.5K-GN | FR-A840-GN three-phase 400v inverter, ND 5.5kW (00170), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (SLD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00170 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-7.5K-GN | FR-A840-GN three-phase 400v inverter, ND 7.5kW (00250), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (SLD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00250 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 6.7 kg | |
| FR-A840-11K-GN | FR-A840-GN three-phase 400v inverter, ND 11kW (00310), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (SLD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00310 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-15K-GN | FR-A840-GN three-phase 400v inverter, ND 15kW (00380), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (SLD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00380 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 8.3 kg | |
| FR-A840-18.5K-GN | FR-A840-GN three-phase 400v inverter, ND 18.5kW (00470), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (SLD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00470 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-22K-GN | FR-A840-GN three-phase 400v inverter, ND 22kW (00620), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (SLD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00620 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 15 kg | |
| FR-A840-30K-GN | FR-A840-GN three-phase 400v inverter, ND 30kW (00770), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (SLD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00770 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 23 kg | |
| FR-A840-37K-GN | FR-A840-GN three-phase 400v inverter, ND 37kW (00930), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (SLD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 00930 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-45K-GN | FR-A840-GN three-phase 400v inverter, ND 45kW (01160), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (SLD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01160 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 41 kg | |
| FR-A840-55K-GN | FR-A840-GN three-phase 400v inverter, ND 55kW (01800), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (SLD): 75/90 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 01800 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 43 kg | |
| FR-A840-75K-GN | FR-A840-GN three-phase 400v inverter, ND 75kW (02160), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (SLD): 110 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02160 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 52 kg | |
| FR-A840-90K-GN | FR-A840-GN three-phase 400v inverter, ND 90kW (02600), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (SLD): 132 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 02600 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 55 kg | |
| FR-A840-110K-GN | FR-A840-GN three-phase 400v inverter, ND 110kW (03250), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (SLD): 160 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03250 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 71 kg | |
| FR-A840-132K-GN | FR-A840-GN three-phase 400v inverter, ND 132kW (03610), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (SLD): 185 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 03610 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 78 kg | |
| FR-A840-160K-GN | FR-A840-GN three-phase 400v inverter, ND 160kW (04320), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 160 kW · Max Applied Motor (SLD): 220 kW · Rated Output Current (ND): 325 A · Rated Capacity (ND): 248 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04320 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-185K-GN | FR-A840-GN three-phase 400v inverter, ND 185kW (04810), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 185 kW · Max Applied Motor (SLD): 250 kW · Rated Output Current (ND): 361 A · Rated Capacity (ND): 275 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 04810 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 117 kg | |
| FR-A840-220K-GN | FR-A840-GN three-phase 400v inverter, ND 220kW (05470), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 220 kW · Max Applied Motor (SLD): 280 kW · Rated Output Current (ND): 432 A · Rated Capacity (ND): 329 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 05470 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-250K-GN | FR-A840-GN three-phase 400v inverter, ND 250kW (06100), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 250 kW · Max Applied Motor (SLD): 315 kW · Rated Output Current (ND): 481 A · Rated Capacity (ND): 367 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06100 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg | |
| FR-A840-280K-GN | FR-A840-GN three-phase 400v inverter, ND 280kW (06830), built-in cc-link ie tsn | MITSUBISHI ELECTRIC | Applied Motor (ND): 280 kW · Max Applied Motor (SLD): 355 kW · Rated Output Current (ND): 547 A · Rated Capacity (ND): 417 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 06830 · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Weight: 166 kg |
Mitsubishi FREQROL FR-A842 separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
Mitsubishi FREQROL FR-A842 separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A842-315K | FR-A842 three-phase 400v separate-converter inverter, ND 315kW (07700) | MITSUBISHI ELECTRIC | Applied Motor (ND): 315 kW · Max Applied Motor (SLD): 400 kW · Rated Output Current (ND): 610 A · Rated Capacity (ND): 465 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 07700 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-355K | FR-A842 three-phase 400v separate-converter inverter, ND 355kW (08660) | MITSUBISHI ELECTRIC | Applied Motor (ND): 355 kW · Max Applied Motor (SLD): 450 kW · Rated Output Current (ND): 683 A · Rated Capacity (ND): 521 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 08660 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-400K | FR-A842 three-phase 400v separate-converter inverter, ND 400kW (09620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 400 kW · Max Applied Motor (SLD): 500 kW · Rated Output Current (ND): 770 A · Rated Capacity (ND): 587 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 09620 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-450K | FR-A842 three-phase 400v separate-converter inverter, ND 450kW (10940) | MITSUBISHI ELECTRIC | Applied Motor (ND): 450 kW · Max Applied Motor (SLD): 560 kW · Rated Output Current (ND): 866 A · Rated Capacity (ND): 660 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 10940 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-500K | FR-A842 three-phase 400v separate-converter inverter, ND 500kW (12120) | MITSUBISHI ELECTRIC | Applied Motor (ND): 500 kW · Max Applied Motor (SLD): 630 kW · Rated Output Current (ND): 962 A · Rated Capacity (ND): 733 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 12120 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg |
Mitsubishi FREQROL FR-A842-E separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in ethernet (ethernet/ip, modbus/tcp). DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
Mitsubishi FREQROL FR-A842-E separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in ethernet (ethernet/ip, modbus/tcp). DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A842-315K-E | FR-A842-E three-phase 400v separate-converter inverter, ND 315kW (07700) | MITSUBISHI ELECTRIC | Applied Motor (ND): 315 kW · Max Applied Motor (SLD): 400 kW · Rated Output Current (ND): 610 A · Rated Capacity (ND): 465 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 07700 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-355K-E | FR-A842-E three-phase 400v separate-converter inverter, ND 355kW (08660) | MITSUBISHI ELECTRIC | Applied Motor (ND): 355 kW · Max Applied Motor (SLD): 450 kW · Rated Output Current (ND): 683 A · Rated Capacity (ND): 521 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 08660 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-400K-E | FR-A842-E three-phase 400v separate-converter inverter, ND 400kW (09620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 400 kW · Max Applied Motor (SLD): 500 kW · Rated Output Current (ND): 770 A · Rated Capacity (ND): 587 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 09620 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-450K-E | FR-A842-E three-phase 400v separate-converter inverter, ND 450kW (10940) | MITSUBISHI ELECTRIC | Applied Motor (ND): 450 kW · Max Applied Motor (SLD): 560 kW · Rated Output Current (ND): 866 A · Rated Capacity (ND): 660 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 10940 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-500K-E | FR-A842-E three-phase 400v separate-converter inverter, ND 500kW (12120) | MITSUBISHI ELECTRIC | Applied Motor (ND): 500 kW · Max Applied Motor (SLD): 630 kW · Rated Output Current (ND): 962 A · Rated Capacity (ND): 733 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 12120 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg |
Mitsubishi FREQROL FR-A842-GF separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie field network. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
Mitsubishi FREQROL FR-A842-GF separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie field network. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A842-315K-GF | FR-A842-GF three-phase 400v separate-converter inverter, ND 315kW (07700) | MITSUBISHI ELECTRIC | Applied Motor (ND): 315 kW · Max Applied Motor (SLD): 400 kW · Rated Output Current (ND): 610 A · Rated Capacity (ND): 465 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 07700 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-355K-GF | FR-A842-GF three-phase 400v separate-converter inverter, ND 355kW (08660) | MITSUBISHI ELECTRIC | Applied Motor (ND): 355 kW · Max Applied Motor (SLD): 450 kW · Rated Output Current (ND): 683 A · Rated Capacity (ND): 521 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 08660 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-400K-GF | FR-A842-GF three-phase 400v separate-converter inverter, ND 400kW (09620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 400 kW · Max Applied Motor (SLD): 500 kW · Rated Output Current (ND): 770 A · Rated Capacity (ND): 587 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 09620 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-450K-GF | FR-A842-GF three-phase 400v separate-converter inverter, ND 450kW (10940) | MITSUBISHI ELECTRIC | Applied Motor (ND): 450 kW · Max Applied Motor (SLD): 560 kW · Rated Output Current (ND): 866 A · Rated Capacity (ND): 660 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 10940 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-500K-GF | FR-A842-GF three-phase 400v separate-converter inverter, ND 500kW (12120) | MITSUBISHI ELECTRIC | Applied Motor (ND): 500 kW · Max Applied Motor (SLD): 630 kW · Rated Output Current (ND): 962 A · Rated Capacity (ND): 733 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 12120 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE Field Network · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg |
Mitsubishi FREQROL FR-A842-GN separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie tsn. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
Mitsubishi FREQROL FR-A842-GN separate-converter high-performance inverter (VFD), Three-Phase 400V, ND 315-500kW built-in cc-link ie tsn. DC bus input (requires FR-CC2 converter unit), SLD/LD/ND/HD rating, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A842-315K-GN | FR-A842-GN three-phase 400v separate-converter inverter, ND 315kW (07700) | MITSUBISHI ELECTRIC | Applied Motor (ND): 315 kW · Max Applied Motor (SLD): 400 kW · Rated Output Current (ND): 610 A · Rated Capacity (ND): 465 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 07700 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-355K-GN | FR-A842-GN three-phase 400v separate-converter inverter, ND 355kW (08660) | MITSUBISHI ELECTRIC | Applied Motor (ND): 355 kW · Max Applied Motor (SLD): 450 kW · Rated Output Current (ND): 683 A · Rated Capacity (ND): 521 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 08660 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 163 kg | |
| FR-A842-400K-GN | FR-A842-GN three-phase 400v separate-converter inverter, ND 400kW (09620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 400 kW · Max Applied Motor (SLD): 500 kW · Rated Output Current (ND): 770 A · Rated Capacity (ND): 587 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 09620 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-450K-GN | FR-A842-GN three-phase 400v separate-converter inverter, ND 450kW (10940) | MITSUBISHI ELECTRIC | Applied Motor (ND): 450 kW · Max Applied Motor (SLD): 560 kW · Rated Output Current (ND): 866 A · Rated Capacity (ND): 660 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 10940 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg | |
| FR-A842-500K-GN | FR-A842-GN three-phase 400v separate-converter inverter, ND 500kW (12120) | MITSUBISHI ELECTRIC | Applied Motor (ND): 500 kW · Max Applied Motor (SLD): 630 kW · Rated Output Current (ND): 962 A · Rated Capacity (ND): 733 kVA · Rating Modes: SLD/LD/ND/HD selectable · Inverter Rating Code: 12120 · Input: DC 430-780V (separate converter type, requires FR-CC2) · Network Interface: Built-in CC-Link IE TSN · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 243 kg |
Mitsubishi FREQROL FR-A842-P parallel-operation high-performance inverter (VFD), three-phase 400V, for 2-unit or 3-unit parallel drive up to 1200kW ND. DC bus input (requires FR-CC2 converter), LD/ND rating, IP00; base units 400/450/500K.
Mitsubishi FREQROL FR-A842-P parallel-operation high-performance inverter (VFD), three-phase 400V, for 2-unit or 3-unit parallel drive up to 1200kW ND. DC bus input (requires FR-CC2 converter), LD/ND rating, IP00; base units 400/450/500K.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A842-400K-P | FR-A842-400K-P parallel-operation 400V inverter (09620), 2/3-unit parallel | MITSUBISHI ELECTRIC | Configuration: Parallel-operation inverter (separate converter type) · Base Unit: FR-A842-400K-P (243 kg/unit) · 2-unit Parallel Motor (ND/LD): 630/710 kW · 2-unit Parallel Current (ND): 1232 A · 2-unit Parallel Capacity (ND): 939 kVA · 3-unit Parallel Motor (ND/LD): 945/1065 kW · 3-unit Parallel Current (ND): 1848 A · 3-unit Parallel Capacity (ND): 1409 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 09620 · Input: DC 430-780V (requires FR-CC2 converter) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight (per unit): 243 kg | |
| FR-A842-450K-P | FR-A842-450K-P parallel-operation 400V inverter (10940), 2/3-unit parallel | MITSUBISHI ELECTRIC | Configuration: Parallel-operation inverter (separate converter type) · Base Unit: FR-A842-450K-P (243 kg/unit) · 2-unit Parallel Motor (ND/LD): 710/800 kW · 2-unit Parallel Current (ND): 1386 A · 2-unit Parallel Capacity (ND): 1056 kVA · 3-unit Parallel Motor (ND/LD): 1065/1200 kW · 3-unit Parallel Current (ND): 2078 A · 3-unit Parallel Capacity (ND): 1584 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 10940 · Input: DC 430-780V (requires FR-CC2 converter) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight (per unit): 243 kg | |
| FR-A842-500K-P | FR-A842-500K-P parallel-operation 400V inverter (12120), 2/3-unit parallel | MITSUBISHI ELECTRIC | Configuration: Parallel-operation inverter (separate converter type) · Base Unit: FR-A842-500K-P (243 kg/unit) · 2-unit Parallel Motor (ND/LD): 800/900 kW · 2-unit Parallel Current (ND): 1539 A · 2-unit Parallel Capacity (ND): 1173 kVA · 3-unit Parallel Motor (ND/LD): 1200/1350 kW · 3-unit Parallel Current (ND): 2309 A · 3-unit Parallel Capacity (ND): 1759 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 12120 · Input: DC 430-780V (requires FR-CC2 converter) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight (per unit): 243 kg |
Mitsubishi FREQROL FR-A846 IP55 dust/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW. Real/PM sensorless vector, LD/ND selectable rating, IP55 / UL Type 12, internal circulation fan.
Mitsubishi FREQROL FR-A846 IP55 dust/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW. Real/PM sensorless vector, LD/ND selectable rating, IP55 / UL Type 12, internal circulation fan.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A846-0.4K | FR-A846 three-phase 400v IP55 inverter, ND 0.4kW (00023) | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (LD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00023 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-0.75K | FR-A846 three-phase 400v IP55 inverter, ND 0.75kW (00038) | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (LD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00038 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-1.5K | FR-A846 three-phase 400v IP55 inverter, ND 1.5kW (00052) | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (LD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00052 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-2.2K | FR-A846 three-phase 400v IP55 inverter, ND 2.2kW (00083) | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (LD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00083 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-3.7K | FR-A846 three-phase 400v IP55 inverter, ND 3.7kW (00126) | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (LD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00126 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 16 kg | |
| FR-A846-5.5K | FR-A846 three-phase 400v IP55 inverter, ND 5.5kW (00170) | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (LD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00170 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 17 kg | |
| FR-A846-7.5K | FR-A846 three-phase 400v IP55 inverter, ND 7.5kW (00250) | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (LD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00250 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 26 kg | |
| FR-A846-11K | FR-A846 three-phase 400v IP55 inverter, ND 11kW (00310) | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (LD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00310 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 26 kg | |
| FR-A846-15K | FR-A846 three-phase 400v IP55 inverter, ND 15kW (00380) | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (LD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00380 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 27 kg | |
| FR-A846-18.5K | FR-A846 three-phase 400v IP55 inverter, ND 18.5kW (00470) | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (LD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00470 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 27 kg | |
| FR-A846-22K | FR-A846 three-phase 400v IP55 inverter, ND 22kW (00620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (LD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00620 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 59 kg | |
| FR-A846-30K | FR-A846 three-phase 400v IP55 inverter, ND 30kW (00770) | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (LD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00770 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 60 kg | |
| FR-A846-37K | FR-A846 three-phase 400v IP55 inverter, ND 37kW (00930) | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (LD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00930 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 63 kg | |
| FR-A846-45K | FR-A846 three-phase 400v IP55 inverter, ND 45kW (01160) | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (LD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 01160 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 64 kg | |
| FR-A846-55K | FR-A846 three-phase 400v IP55 inverter, ND 55kW (01800) | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (LD): 75 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 01800 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 147 kg | |
| FR-A846-75K | FR-A846 three-phase 400v IP55 inverter, ND 75kW (02160) | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (LD): 90 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 02160 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 150 kg | |
| FR-A846-90K | FR-A846 three-phase 400v IP55 inverter, ND 90kW (02600) | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (LD): 110 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 02600 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 153 kg | |
| FR-A846-110K | FR-A846 three-phase 400v IP55 inverter, ND 110kW (03250) | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (LD): 132 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 03250 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 189 kg | |
| FR-A846-132K | FR-A846 three-phase 400v IP55 inverter, ND 132kW (03610) | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (LD): 160 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 03610 · Protection: IP55 (dust/water-proof), UL Type 12 · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 193 kg |
Mitsubishi FREQROL FR-A846-E IP55 dust/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW built-in ethernet (ethernet/ip, modbus/tcp). Real/PM sensorless vector, LD/ND selectable rating, IP55 / UL Type 12, internal circulation fan.
Mitsubishi FREQROL FR-A846-E IP55 dust/water-proof high-performance inverter (VFD), Three-Phase 400V, ND 0.4-132kW built-in ethernet (ethernet/ip, modbus/tcp). Real/PM sensorless vector, LD/ND selectable rating, IP55 / UL Type 12, internal circulation fan.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-A846-0.4K-E | FR-A846-E three-phase 400v IP55 inverter, ND 0.4kW (00023) | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.4 kW · Max Applied Motor (LD): 0.75 kW · Rated Output Current (ND): 1.5 A · Rated Capacity (ND): 1.1 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00023 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-0.75K-E | FR-A846-E three-phase 400v IP55 inverter, ND 0.75kW (00038) | MITSUBISHI ELECTRIC | Applied Motor (ND): 0.75 kW · Max Applied Motor (LD): 1.5 kW · Rated Output Current (ND): 2.5 A · Rated Capacity (ND): 1.9 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00038 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-1.5K-E | FR-A846-E three-phase 400v IP55 inverter, ND 1.5kW (00052) | MITSUBISHI ELECTRIC | Applied Motor (ND): 1.5 kW · Max Applied Motor (LD): 2.2 kW · Rated Output Current (ND): 4 A · Rated Capacity (ND): 3 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00052 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-2.2K-E | FR-A846-E three-phase 400v IP55 inverter, ND 2.2kW (00083) | MITSUBISHI ELECTRIC | Applied Motor (ND): 2.2 kW · Max Applied Motor (LD): 3.7 kW · Rated Output Current (ND): 6 A · Rated Capacity (ND): 4.6 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00083 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 15 kg | |
| FR-A846-3.7K-E | FR-A846-E three-phase 400v IP55 inverter, ND 3.7kW (00126) | MITSUBISHI ELECTRIC | Applied Motor (ND): 3.7 kW · Max Applied Motor (LD): 5.5 kW · Rated Output Current (ND): 9 A · Rated Capacity (ND): 6.9 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00126 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 16 kg | |
| FR-A846-5.5K-E | FR-A846-E three-phase 400v IP55 inverter, ND 5.5kW (00170) | MITSUBISHI ELECTRIC | Applied Motor (ND): 5.5 kW · Max Applied Motor (LD): 7.5 kW · Rated Output Current (ND): 12 A · Rated Capacity (ND): 9.1 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00170 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 17 kg | |
| FR-A846-7.5K-E | FR-A846-E three-phase 400v IP55 inverter, ND 7.5kW (00250) | MITSUBISHI ELECTRIC | Applied Motor (ND): 7.5 kW · Max Applied Motor (LD): 11 kW · Rated Output Current (ND): 17 A · Rated Capacity (ND): 13 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00250 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 26 kg | |
| FR-A846-11K-E | FR-A846-E three-phase 400v IP55 inverter, ND 11kW (00310) | MITSUBISHI ELECTRIC | Applied Motor (ND): 11 kW · Max Applied Motor (LD): 15 kW · Rated Output Current (ND): 23 A · Rated Capacity (ND): 18 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00310 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 26 kg | |
| FR-A846-15K-E | FR-A846-E three-phase 400v IP55 inverter, ND 15kW (00380) | MITSUBISHI ELECTRIC | Applied Motor (ND): 15 kW · Max Applied Motor (LD): 18.5 kW · Rated Output Current (ND): 31 A · Rated Capacity (ND): 24 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00380 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 27 kg | |
| FR-A846-18.5K-E | FR-A846-E three-phase 400v IP55 inverter, ND 18.5kW (00470) | MITSUBISHI ELECTRIC | Applied Motor (ND): 18.5 kW · Max Applied Motor (LD): 22 kW · Rated Output Current (ND): 38 A · Rated Capacity (ND): 29 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00470 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 27 kg | |
| FR-A846-22K-E | FR-A846-E three-phase 400v IP55 inverter, ND 22kW (00620) | MITSUBISHI ELECTRIC | Applied Motor (ND): 22 kW · Max Applied Motor (LD): 30 kW · Rated Output Current (ND): 44 A · Rated Capacity (ND): 34 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00620 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 59 kg | |
| FR-A846-30K-E | FR-A846-E three-phase 400v IP55 inverter, ND 30kW (00770) | MITSUBISHI ELECTRIC | Applied Motor (ND): 30 kW · Max Applied Motor (LD): 37 kW · Rated Output Current (ND): 57 A · Rated Capacity (ND): 43 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00770 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 60 kg | |
| FR-A846-37K-E | FR-A846-E three-phase 400v IP55 inverter, ND 37kW (00930) | MITSUBISHI ELECTRIC | Applied Motor (ND): 37 kW · Max Applied Motor (LD): 45 kW · Rated Output Current (ND): 71 A · Rated Capacity (ND): 54 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 00930 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 63 kg | |
| FR-A846-45K-E | FR-A846-E three-phase 400v IP55 inverter, ND 45kW (01160) | MITSUBISHI ELECTRIC | Applied Motor (ND): 45 kW · Max Applied Motor (LD): 55 kW · Rated Output Current (ND): 86 A · Rated Capacity (ND): 66 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 01160 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 64 kg | |
| FR-A846-55K-E | FR-A846-E three-phase 400v IP55 inverter, ND 55kW (01800) | MITSUBISHI ELECTRIC | Applied Motor (ND): 55 kW · Max Applied Motor (LD): 75 kW · Rated Output Current (ND): 110 A · Rated Capacity (ND): 84 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 01800 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 147 kg | |
| FR-A846-75K-E | FR-A846-E three-phase 400v IP55 inverter, ND 75kW (02160) | MITSUBISHI ELECTRIC | Applied Motor (ND): 75 kW · Max Applied Motor (LD): 90 kW · Rated Output Current (ND): 144 A · Rated Capacity (ND): 110 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 02160 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 150 kg | |
| FR-A846-90K-E | FR-A846-E three-phase 400v IP55 inverter, ND 90kW (02600) | MITSUBISHI ELECTRIC | Applied Motor (ND): 90 kW · Max Applied Motor (LD): 110 kW · Rated Output Current (ND): 180 A · Rated Capacity (ND): 137 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 02600 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 153 kg | |
| FR-A846-110K-E | FR-A846-E three-phase 400v IP55 inverter, ND 110kW (03250) | MITSUBISHI ELECTRIC | Applied Motor (ND): 110 kW · Max Applied Motor (LD): 132 kW · Rated Output Current (ND): 216 A · Rated Capacity (ND): 165 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 03250 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 189 kg | |
| FR-A846-132K-E | FR-A846-E three-phase 400v IP55 inverter, ND 132kW (03610) | MITSUBISHI ELECTRIC | Applied Motor (ND): 132 kW · Max Applied Motor (LD): 160 kW · Rated Output Current (ND): 260 A · Rated Capacity (ND): 198 kVA · Rating Modes: LD/ND selectable · Inverter Rating Code: 03610 · Protection: IP55 (dust/water-proof), UL Type 12 · Network Interface: Built-in Ethernet (EtherNet/IP, Modbus/TCP) · Output Terminal: FM (pulse) / CA (0-10V analog), Pr.54 selectable · Cooling: Self/Forced-air cooling + internal circulation fan · Weight: 193 kg |
Mitsubishi FREQROL FR-CC2-H converter unit for the FR-A842 separate-converter inverter, three-phase 400V, 315-630kW. DC 430-780V bus output, built-in DC reactor, IP00, forced-air cooling.
Mitsubishi FREQROL FR-CC2-H converter unit for the FR-A842 separate-converter inverter, three-phase 400V, 315-630kW. DC 430-780V bus output, built-in DC reactor, IP00, forced-air cooling.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-CC2-H315K | FR-CC2-H315K converter unit, 315kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 315 kW · Overload Rating: 200% 60s / 250% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 610 A · Power Supply Capacity: 465 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 210 kg | |
| FR-CC2-H355K | FR-CC2-H355K converter unit, 355kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 355 kW · Overload Rating: 200% 60s / 250% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 683 A · Power Supply Capacity: 521 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 213 kg | |
| FR-CC2-H400K | FR-CC2-H400K converter unit, 400kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 400 kW · Overload Rating: 200% 60s / 250% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 770 A · Power Supply Capacity: 587 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 282 kg | |
| FR-CC2-H450K | FR-CC2-H450K converter unit, 450kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 450 kW · Overload Rating: 200% 60s / 250% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 866 A · Power Supply Capacity: 660 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 285 kg | |
| FR-CC2-H500K | FR-CC2-H500K converter unit, 500kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 500 kW · Overload Rating: 150% 60s / 200% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 962 A · Power Supply Capacity: 733 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 288 kg | |
| FR-CC2-H560K | FR-CC2-H560K converter unit, 560kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 560 kW · Overload Rating: 120% 60s / 150% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 1094 A · Power Supply Capacity: 833 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 293 kg | |
| FR-CC2-H630K | FR-CC2-H630K converter unit, 630kW, DC430-780V, for FR-A842 | MITSUBISHI ELECTRIC | Type: Converter unit (for FR-A842 separate-converter inverter) · Applied Motor: 630 kW · Overload Rating: 110% 60s / 120% 3s · DC Output Voltage: DC 430-780V · Rated Input Current: 1212 A · Power Supply Capacity: 924 kVA · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) · Weight: 294 kg |
Mitsubishi FREQROL FR-CC2-H-P parallel converter unit for FR-A842-P parallel-operation inverters, three-phase 400V, used in 2-unit or 3-unit parallel up to 1350kW. DC 430-780V output, built-in DC reactor, IP00.
Mitsubishi FREQROL FR-CC2-H-P parallel converter unit for FR-A842-P parallel-operation inverters, three-phase 400V, used in 2-unit or 3-unit parallel up to 1350kW. DC 430-780V output, built-in DC reactor, IP00.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-CC2-H400K-P | FR-CC2-H400K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) · Base Unit: FR-CC2-H400K-P · 2-unit Parallel Motor: 630 kW · 3-unit Parallel Motor: 945 kW · 2-unit Input Current: 1232 A · 3-unit Input Current: 1848 A · 2-unit Power Supply Capacity: 939 kVA · 3-unit Power Supply Capacity: 1409 kVA · Overload Rating: 150% 60s / 200% 3s · DC Output Voltage: DC 430-780V · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) | |
| FR-CC2-H450K-P | FR-CC2-H450K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) · Base Unit: FR-CC2-H450K-P · 2-unit Parallel Motor: 710 kW · 3-unit Parallel Motor: 1065 kW · 2-unit Input Current: 1386 A · 3-unit Input Current: 2078 A · 2-unit Power Supply Capacity: 1056 kVA · 3-unit Power Supply Capacity: 1584 kVA · Overload Rating: 150% 60s / 200% 3s · DC Output Voltage: DC 430-780V · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) | |
| FR-CC2-H500K-P | FR-CC2-H500K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) · Base Unit: FR-CC2-H500K-P · 2-unit Parallel Motor: 800 kW · 3-unit Parallel Motor: 1200 kW · 2-unit Input Current: 1539 A · 3-unit Input Current: 2309 A · 2-unit Power Supply Capacity: 1173 kVA · 3-unit Power Supply Capacity: 1759 kVA · Overload Rating: 150% 60s / 200% 3s · DC Output Voltage: DC 430-780V · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) | |
| FR-CC2-H560K-P | FR-CC2-H560K-P parallel converter unit, 2/3-unit parallel, for FR-A842-P | MITSUBISHI ELECTRIC | Type: Parallel converter unit (for FR-A842-P parallel inverters) · Base Unit: FR-CC2-H560K-P · 2-unit Parallel Motor: 900 kW · 3-unit Parallel Motor: 1350 kW · 2-unit Input Current: 1750 A · 3-unit Input Current: 2626 A · 2-unit Power Supply Capacity: 1334 kVA · 3-unit Power Supply Capacity: 2002 kVA · Overload Rating: 150% 60s / 200% 3s · DC Output Voltage: DC 430-780V · Input: 3-phase 380-500V 50/60Hz · DC Reactor: Built-in · Cooling: Forced-air cooling · Protection: IP00 (open chassis) |
Mitsubishi FREQROL FR-D710W general-purpose inverter (VFD), Single-Phase 100V input, 0.1-0.75kW (3-phase 200-230V output). Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20.
Mitsubishi FREQROL FR-D710W general-purpose inverter (VFD), Single-Phase 100V input, 0.1-0.75kW (3-phase 200-230V output). Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-D710W-0.1K | FR-D710W single-phase 100v inverter, 0.1kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A · Input Power: Single-phase 100-115V 50/60Hz · Output Voltage: 3-phase 200-230V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.6 kg | |
| FR-D710W-0.2K | FR-D710W single-phase 100v inverter, 0.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.4 A · Input Power: Single-phase 100-115V 50/60Hz · Output Voltage: 3-phase 200-230V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.7 kg | |
| FR-D710W-0.4K | FR-D710W single-phase 100v inverter, 0.4kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.0 kVA · Rated Current: 2.5 A · Input Power: Single-phase 100-115V 50/60Hz · Output Voltage: 3-phase 200-230V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.9 kg | |
| FR-D710W-0.75K | FR-D710W single-phase 100v inverter, 0.75kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 4.2 A · Input Power: Single-phase 100-115V 50/60Hz · Output Voltage: 3-phase 200-230V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 1.4 kg |
Mitsubishi FREQROL FR-D720 general-purpose inverter (VFD), Three-Phase 200V input, 0.1-15kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
Mitsubishi FREQROL FR-D720 general-purpose inverter (VFD), Three-Phase 200V input, 0.1-15kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-D720-0.1K | FR-D720 three-phase 200v inverter, 0.1kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720-0.1K-EA | FR-D720 three-phase 200v inverter, 0.1kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720-0.2K | FR-D720 three-phase 200v inverter, 0.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.4 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720-0.2K-EA | FR-D720 three-phase 200v inverter, 0.2kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.4 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720-0.4K | FR-D720 three-phase 200v inverter, 0.4kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.0 kVA · Rated Current: 2.5 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.8 kg | |
| FR-D720-0.4K-EA | FR-D720 three-phase 200v inverter, 0.4kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.0 kVA · Rated Current: 2.5 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.8 kg | |
| FR-D720-0.75K | FR-D720 three-phase 200v inverter, 0.75kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 4.2 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 1.0 kg | |
| FR-D720-0.75K-EA | FR-D720 three-phase 200v inverter, 0.75kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 4.2 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 1.0 kg | |
| FR-D720-1.5K | FR-D720 three-phase 200v inverter, 1.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.8 kVA · Rated Current: 7.0 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 50% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D720-1.5K-EA | FR-D720 three-phase 200v inverter, 1.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.8 kVA · Rated Current: 7.0 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 50% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D720-2.2K | FR-D720 three-phase 200v inverter, 2.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.0 kVA · Rated Current: 10.0 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D720-2.2K-EA | FR-D720 three-phase 200v inverter, 2.2kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.0 kVA · Rated Current: 10.0 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D720-3.7K | FR-D720 three-phase 200v inverter, 3.7kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 6.6 kVA · Rated Current: 16.5 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.8 kg | |
| FR-D720-3.7K-EA | FR-D720 three-phase 200v inverter, 3.7kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 6.6 kVA · Rated Current: 16.5 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.8 kg | |
| FR-D720-5.5K | FR-D720 three-phase 200v inverter, 5.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 23.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 3.6 kg | |
| FR-D720-5.5K-EA | FR-D720 three-phase 200v inverter, 5.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 23.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 3.6 kg | |
| FR-D720-7.5K | FR-D720 three-phase 200v inverter, 7.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 12.7 kVA · Rated Current: 31.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 3.6 kg | |
| FR-D720-7.5K-EA | FR-D720 three-phase 200v inverter, 7.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 12.7 kVA · Rated Current: 31.8 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 3.6 kg | |
| FR-D720-11K | FR-D720 three-phase 200v inverter, 11kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.9 kVA · Rated Current: 45 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 6.5 kg | |
| FR-D720-11K-EA | FR-D720 three-phase 200v inverter, 11kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.1 kVA · Rated Current: 45 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 6.5 kg | |
| FR-D720-15K | FR-D720 three-phase 200v inverter, 15kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.1 kVA · Rated Current: 58 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 6.5 kg | |
| FR-D720-15K-EA | FR-D720 three-phase 200v inverter, 15kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 22.1 kVA · Rated Current: 58 A · Input Power: 3-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 6.5 kg |
Mitsubishi FREQROL FR-D720S general-purpose inverter (VFD), Single-Phase 200V input, 0.1-2.2kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
Mitsubishi FREQROL FR-D720S general-purpose inverter (VFD), Single-Phase 200V input, 0.1-2.2kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-D720S-0.1K | FR-D720S single-phase 200v inverter, 0.1kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720S-0.1K-EA | FR-D720S single-phase 200v inverter, 0.1kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720S-0.2K | FR-D720S single-phase 200v inverter, 0.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.4 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720S-0.2K-EA | FR-D720S single-phase 200v inverter, 0.2kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.4 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 150% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.5 kg | |
| FR-D720S-0.4K | FR-D720S single-phase 200v inverter, 0.4kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.0 kVA · Rated Current: 2.5 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 0.9 kg | |
| FR-D720S-0.4K-EA | FR-D720S single-phase 200v inverter, 0.4kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.0 kVA · Rated Current: 2.5 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 0.9 kg | |
| FR-D720S-0.75K | FR-D720S single-phase 200v inverter, 0.75kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 4.2 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 1.1 kg | |
| FR-D720S-0.75K-EA | FR-D720S single-phase 200v inverter, 0.75kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 4.2 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 1.1 kg | |
| FR-D720S-1.5K | FR-D720S single-phase 200v inverter, 1.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.8 kVA · Rated Current: 7.0 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 50% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D720S-1.5K-EA | FR-D720S single-phase 200v inverter, 1.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.8 kVA · Rated Current: 7.0 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 50% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D720S-2.2K | FR-D720S single-phase 200v inverter, 2.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.0 kVA · Rated Current: 10.0 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 2.0 kg | |
| FR-D720S-2.2K-EA | FR-D720S single-phase 200v inverter, 2.2kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.0 kVA · Rated Current: 10.0 A · Input Power: Single-phase 200-240V 50/60Hz · Output Voltage: 3-phase 200-240V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 2.0 kg |
Mitsubishi FREQROL FR-D740 general-purpose inverter (VFD), Three-Phase 400V input, 0.4-15kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
Mitsubishi FREQROL FR-D740 general-purpose inverter (VFD), Three-Phase 400V input, 0.4-15kW. Spring-clamp control terminals, 150% 60s / 200% 0.5s overload, IP20; FM (pulse) and AM (0-10V) output terminal versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-D740-0.4K | FR-D740 three-phase 400v inverter, 0.4kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 0.9 kVA · Rated Current: 1.2 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 1.3 kg | |
| FR-D740-0.4K-EA | FR-D740 three-phase 400v inverter, 0.4kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 0.9 kVA · Rated Current: 1.2 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 1.3 kg | |
| FR-D740-0.75K | FR-D740 three-phase 400v inverter, 0.75kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 2.2 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 100% · Output Monitor: FM terminal (pulse train output) · Cooling: Self-cooling · Weight: 1.3 kg | |
| FR-D740-0.75K-EA | FR-D740 three-phase 400v inverter, 0.75kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 1.7 kVA · Rated Current: 2.2 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 100% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Self-cooling · Weight: 1.3 kg | |
| FR-D740-1.5K | FR-D740 three-phase 400v inverter, 1.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.7 kVA · Rated Current: 3.6 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 50% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D740-1.5K-EA | FR-D740 three-phase 400v inverter, 1.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 2.7 kVA · Rated Current: 3.6 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 50% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.4 kg | |
| FR-D740-2.2K | FR-D740 three-phase 400v inverter, 2.2kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 3.8 kVA · Rated Current: 5.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D740-2.2K-EA | FR-D740 three-phase 400v inverter, 2.2kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 3.8 kVA · Rated Current: 5.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D740-3.7K | FR-D740 three-phase 400v inverter, 3.7kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 6.1 kVA · Rated Current: 8.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D740-3.7K-EA | FR-D740 three-phase 400v inverter, 3.7kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 6.1 kVA · Rated Current: 8.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 1.5 kg | |
| FR-D740-5.5K | FR-D740 three-phase 400v inverter, 5.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 3.3 kg | |
| FR-D740-5.5K-EA | FR-D740 three-phase 400v inverter, 5.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.1 kVA · Rated Current: 12.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 3.3 kg | |
| FR-D740-7.5K | FR-D740 three-phase 400v inverter, 7.5kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 12.2 kVA · Rated Current: 16.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 3.3 kg | |
| FR-D740-7.5K-EA | FR-D740 three-phase 400v inverter, 7.5kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 12.2 kVA · Rated Current: 16.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 3.3 kg | |
| FR-D740-11K | FR-D740 three-phase 400v inverter, 11kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 6.0 kg | |
| FR-D740-11K-EA | FR-D740 three-phase 400v inverter, 11kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 17.5 kVA · Rated Current: 23.0 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 6.0 kg | |
| FR-D740-15K | FR-D740 three-phase 400v inverter, 15kW, FM terminal | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 22.5 kVA · Rated Current: 29.5 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: FM terminal (pulse train output) · Cooling: Forced-air cooling · Weight: 6.0 kg | |
| FR-D740-15K-EA | FR-D740 three-phase 400v inverter, 15kW, AM terminal | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 22.5 kVA · Rated Current: 29.5 A · Input Power: 3-phase 380-480V 50/60Hz · Output Voltage: 3-phase 380-480V · Regen Braking Torque: 20% · Output Monitor: AM terminal (0-10V analog output) · Cooling: Forced-air cooling · Weight: 6.0 kg |
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. CC-Link communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. CC-Link communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720-0.1KNC | FR-E720-0.1KNC CC-Link communication, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.4 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: CC-Link communication | |
| FR-E720-0.2KNC | FR-E720-0.2KNC CC-Link communication, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.8 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: CC-Link communication | |
| FR-E720-0.4KNC | FR-E720-0.4KNC CC-Link communication, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 0.7 kg · Spec Type: CC-Link communication | |
| FR-E720-0.75KNC | FR-E720-0.75KNC CC-Link communication, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.0 kg · Spec Type: CC-Link communication | |
| FR-E720-1.5KNC | FR-E720-1.5KNC CC-Link communication, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 50% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: CC-Link communication | |
| FR-E720-2.2KNC | FR-E720-2.2KNC CC-Link communication, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: CC-Link communication | |
| FR-E720-3.7KNC | FR-E720-3.7KNC CC-Link communication, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.0 kVA · Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 1.7 kg · Spec Type: CC-Link communication | |
| FR-E720-5.5KNC | FR-E720-5.5KNC CC-Link communication, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: CC-Link communication | |
| FR-E720-7.5KNC | FR-E720-7.5KNC CC-Link communication, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.1 kVA · Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: CC-Link communication | |
| FR-E720-11KNC | FR-E720-11KNC CC-Link communication, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 18.7 kVA · Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: CC-Link communication | |
| FR-E720-15KNC | FR-E720-15KNC CC-Link communication, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.9 kVA · Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: CC-Link (2-port A6CON-L5P / 35505-6000-B0M GF) · Safety Function: S1/S2 dual-channel input · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: CC-Link communication |
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. FL-remote communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. FL-remote communication. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720-0.1KNF | FR-E720-0.1KNF FL-remote communication, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.4 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: FL-remote communication | |
| FR-E720-0.2KNF | FR-E720-0.2KNF FL-remote communication, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.8 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: FL-remote communication | |
| FR-E720-0.4KNF | FR-E720-0.4KNF FL-remote communication, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 0.7 kg · Spec Type: FL-remote communication | |
| FR-E720-0.75KNF | FR-E720-0.75KNF FL-remote communication, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.0 kg · Spec Type: FL-remote communication | |
| FR-E720-1.5KNF | FR-E720-1.5KNF FL-remote communication, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 50% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: FL-remote communication | |
| FR-E720-2.2KNF | FR-E720-2.2KNF FL-remote communication, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: FL-remote communication | |
| FR-E720-3.7KNF | FR-E720-3.7KNF FL-remote communication, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.0 kVA · Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 1.7 kg · Spec Type: FL-remote communication | |
| FR-E720-5.5KNF | FR-E720-5.5KNF FL-remote communication, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: FL-remote communication | |
| FR-E720-7.5KNF | FR-E720-7.5KNF FL-remote communication, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.1 kVA · Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: FL-remote communication | |
| FR-E720-11KNF | FR-E720-11KNF FL-remote communication, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 18.7 kVA · Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: FL-remote communication | |
| FR-E720-15KNF | FR-E720-15KNF FL-remote communication, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.9 kVA · Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP00 (open type) · Communication: FL-remote network (dedicated connector) · Safety Function: S1/S2 dual-channel input (Safety Monitor 2 output) · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: FL-remote communication |
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. Safety Stop compatible. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
Mitsubishi FREQROL-E700 3-phase 200V compact VFD, 0.1–15kW. Safety Stop compatible. Advanced magnetic flux vector control with 200%/0.5Hz starting torque (≤3.7K). UL/cUL/CE compliant.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FR-E720-0.1KSC | FR-E720-0.1KSC Safety Stop compatible, 0.1kW | MITSUBISHI ELECTRIC | Applied Motor: 0.1 kW · Rated Capacity: 0.3 kVA · Rated Current: 0.8 A (0.8 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.4 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: Safety Stop compatible | |
| FR-E720-0.2KSC | FR-E720-0.2KSC Safety Stop compatible, 0.2kW | MITSUBISHI ELECTRIC | Applied Motor: 0.2 kW · Rated Capacity: 0.6 kVA · Rated Current: 1.5 A (1.4 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 150% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 0.8 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: None (no brake resistor connection) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.5 kg · Spec Type: Safety Stop compatible | |
| FR-E720-0.4KSC | FR-E720-0.4KSC Safety Stop compatible, 0.4kW | MITSUBISHI ELECTRIC | Applied Motor: 0.4 kW · Rated Capacity: 1.2 kVA · Rated Current: 3 A (2.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 1.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 0.7 kg · Spec Type: Safety Stop compatible | |
| FR-E720-0.75KSC | FR-E720-0.75KSC Safety Stop compatible, 0.75kW | MITSUBISHI ELECTRIC | Applied Motor: 0.75 kW · Rated Capacity: 2.0 kVA · Rated Current: 5 A (4.1 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 100% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 2.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Self-cooled · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.0 kg · Spec Type: Safety Stop compatible | |
| FR-E720-1.5KSC | FR-E720-1.5KSC Safety Stop compatible, 1.5kW | MITSUBISHI ELECTRIC | Applied Motor: 1.5 kW · Rated Capacity: 3.2 kVA · Rated Current: 8 A (7 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 50% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 4.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Safety Stop compatible | |
| FR-E720-2.2KSC | FR-E720-2.2KSC Safety Stop compatible, 2.2kW | MITSUBISHI ELECTRIC | Applied Motor: 2.2 kW · Rated Capacity: 4.4 kVA · Rated Current: 11 A (10 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 5.5 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.4 kg · Spec Type: Safety Stop compatible | |
| FR-E720-3.7KSC | FR-E720-3.7KSC Safety Stop compatible, 3.7kW | MITSUBISHI ELECTRIC | Applied Motor: 3.7 kW · Rated Capacity: 7.0 kVA · Rated Current: 17.5 A (16.5 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 9 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 1.7 kg · Spec Type: Safety Stop compatible | |
| FR-E720-5.5KSC | FR-E720-5.5KSC Safety Stop compatible, 5.5kW | MITSUBISHI ELECTRIC | Applied Motor: 5.5 kW · Rated Capacity: 9.5 kVA · Rated Current: 24 A (23 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 12 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: Safety Stop compatible | |
| FR-E720-7.5KSC | FR-E720-7.5KSC Safety Stop compatible, 7.5kW | MITSUBISHI ELECTRIC | Applied Motor: 7.5 kW · Rated Capacity: 13.1 kVA · Rated Current: 33 A (31 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 17 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 4.3 kg · Spec Type: Safety Stop compatible | |
| FR-E720-11KSC | FR-E720-11KSC Safety Stop compatible, 11kW | MITSUBISHI ELECTRIC | Applied Motor: 11 kW · Rated Capacity: 18.7 kVA · Rated Current: 47 A (44 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 20 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: Safety Stop compatible | |
| FR-E720-15KSC | FR-E720-15KSC Safety Stop compatible, 15kW | MITSUBISHI ELECTRIC | Applied Motor: 15 kW · Rated Capacity: 23.9 kVA · Rated Current: 60 A (57 A at 2kHz+ low-noise PWM) · Overload Current: 150% 60s, 200% 3s (inverse-time) · Output Voltage: 3-Phase 200-240V · Regenerative Torque: 20% · Input: 3-phase 200-240V 50/60Hz · Input Voltage Range: 170-264V (DC240-373V) · Frequency Tolerance: ±5% · Power Supply Capacity: 28 kVA · Control Method: V/F, General-purpose magnetic flux vector, Advanced magnetic flux vector, Optimum excitation · Max Frequency: 400 Hz · PWM Carrier Frequency: 0.7–14.5 kHz (Soft-PWM selectable) · Brake Transistor: Built-in (0.4K and above) · Cooling: Forced air · Protection Structure: IP20 (enclosed) · Communication: RS-485 (PU connector, EIA-485), USB Mini-B (Ver 1.1) · Safety Function: EN ISO 13849-1 Cat.3 PLd / EN62061 SIL2 / IEC61508 SIL2 · Standards: UL, cUL, CE · Mass: 6.5 kg · Spec Type: Safety Stop compatible |