Sensors
[OMRON] — E2B M18 Cylindrical Proximity Sensor (Single/Double, Shielded/Unshielded, Brass, PNP/NPN)
▶OMRON E2B Series M18 brass cylindrical proximity sensor. Single: Shielded 5mm / Unshielded 10mm. Double: Shielded 8mm / Unshielded 16mm. Short and Long barrel. PNP and NPN. NO and NC. Pre-wired 2m/5m and M12 connector.
OMRON E2B Series M18 brass cylindrical proximity sensor. Single: Shielded 5mm / Unshielded 10mm. Double: Shielded 8mm / Unshielded 16mm. Short and Long barrel. PNP and NPN. NO and NC. Pre-wired 2m/5m and M12 connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2B-M18KS05-WP-B1 2M | E2B M18 Single distance Shielded 5 mm PNP NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KS05-WP-B1 5M | E2B M18 Single distance Shielded 5 mm PNP NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KS05-WP-B2 2M | E2B M18 Single distance Shielded 5 mm PNP NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KS05-WP-B2 5M | E2B M18 Single distance Shielded 5 mm PNP NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KS05-WP-C1 2M | E2B M18 Single distance Shielded 5 mm NPN NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KS05-WP-C1 5M | E2B M18 Single distance Shielded 5 mm NPN NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KS05-WP-C2 2M | E2B M18 Single distance Shielded 5 mm NPN NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KS05-WP-C2 5M | E2B M18 Single distance Shielded 5 mm NPN NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KS05-M1-B1 | E2B M18 Single distance Shielded 5 mm PNP NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18KS05-M1-B2 | E2B M18 Single distance Shielded 5 mm PNP NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18KS05-M1-C1 | E2B M18 Single distance Shielded 5 mm NPN NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18KS05-M1-C2 | E2B M18 Single distance Shielded 5 mm NPN NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18LS05-WP-B1 2M | E2B M18 Single distance Shielded 5 mm PNP NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LS05-WP-B1 5M | E2B M18 Single distance Shielded 5 mm PNP NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LS05-WP-B2 2M | E2B M18 Single distance Shielded 5 mm PNP NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LS05-WP-B2 5M | E2B M18 Single distance Shielded 5 mm PNP NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LS05-WP-C1 2M | E2B M18 Single distance Shielded 5 mm NPN NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LS05-WP-C1 5M | E2B M18 Single distance Shielded 5 mm NPN NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LS05-WP-C2 2M | E2B M18 Single distance Shielded 5 mm NPN NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LS05-WP-C2 5M | E2B M18 Single distance Shielded 5 mm NPN NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LS05-M1-B1 | E2B M18 Single distance Shielded 5 mm PNP NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18LS05-M1-B2 | E2B M18 Single distance Shielded 5 mm PNP NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18LS05-M1-C1 | E2B M18 Single distance Shielded 5 mm NPN NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18LS05-M1-C2 | E2B M18 Single distance Shielded 5 mm NPN NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Shielded | Sensing Distance: 5 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18KN10-WP-B1 2M | E2B M18 Single distance Unshielded 10 mm PNP NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KN10-WP-B1 5M | E2B M18 Single distance Unshielded 10 mm PNP NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KN10-WP-B2 2M | E2B M18 Single distance Unshielded 10 mm PNP NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KN10-WP-B2 5M | E2B M18 Single distance Unshielded 10 mm PNP NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KN10-WP-C1 2M | E2B M18 Single distance Unshielded 10 mm NPN NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KN10-WP-C1 5M | E2B M18 Single distance Unshielded 10 mm NPN NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KN10-WP-C2 2M | E2B M18 Single distance Unshielded 10 mm NPN NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KN10-WP-C2 5M | E2B M18 Single distance Unshielded 10 mm NPN NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KN10-M1-B1 | E2B M18 Single distance Unshielded 10 mm PNP NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18KN10-M1-B2 | E2B M18 Single distance Unshielded 10 mm PNP NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18KN10-M1-C1 | E2B M18 Single distance Unshielded 10 mm NPN NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18KN10-M1-C2 | E2B M18 Single distance Unshielded 10 mm NPN NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18LN10-WP-B1 2M | E2B M18 Single distance Unshielded 10 mm PNP NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LN10-WP-B1 5M | E2B M18 Single distance Unshielded 10 mm PNP NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LN10-WP-B2 2M | E2B M18 Single distance Unshielded 10 mm PNP NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LN10-WP-B2 5M | E2B M18 Single distance Unshielded 10 mm PNP NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LN10-WP-C1 2M | E2B M18 Single distance Unshielded 10 mm NPN NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LN10-WP-C1 5M | E2B M18 Single distance Unshielded 10 mm NPN NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LN10-WP-C2 2M | E2B M18 Single distance Unshielded 10 mm NPN NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LN10-WP-C2 5M | E2B M18 Single distance Unshielded 10 mm NPN NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LN10-M1-B1 | E2B M18 Single distance Unshielded 10 mm PNP NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18LN10-M1-B2 | E2B M18 Single distance Unshielded 10 mm PNP NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18LN10-M1-C1 | E2B M18 Single distance Unshielded 10 mm NPN NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18LN10-M1-C2 | E2B M18 Single distance Unshielded 10 mm NPN NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Single distance | Shield: Unshielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18KS08-WP-B1 2M | E2B M18 Double distance Shielded 8 mm PNP NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KS08-WP-B1 5M | E2B M18 Double distance Shielded 8 mm PNP NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KS08-WP-B2 2M | E2B M18 Double distance Shielded 8 mm PNP NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KS08-WP-B2 5M | E2B M18 Double distance Shielded 8 mm PNP NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KS08-WP-C1 2M | E2B M18 Double distance Shielded 8 mm NPN NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KS08-WP-C1 5M | E2B M18 Double distance Shielded 8 mm NPN NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KS08-WP-C2 2M | E2B M18 Double distance Shielded 8 mm NPN NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KS08-WP-C2 5M | E2B M18 Double distance Shielded 8 mm NPN NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KS08-M1-B1 | E2B M18 Double distance Shielded 8 mm PNP NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18KS08-M1-B2 | E2B M18 Double distance Shielded 8 mm PNP NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18KS08-M1-C1 | E2B M18 Double distance Shielded 8 mm NPN NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18KS08-M1-C2 | E2B M18 Double distance Shielded 8 mm NPN NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18LS08-WP-B1 2M | E2B M18 Double distance Shielded 8 mm PNP NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LS08-WP-B1 5M | E2B M18 Double distance Shielded 8 mm PNP NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LS08-WP-B2 2M | E2B M18 Double distance Shielded 8 mm PNP NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LS08-WP-B2 5M | E2B M18 Double distance Shielded 8 mm PNP NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LS08-WP-C1 2M | E2B M18 Double distance Shielded 8 mm NPN NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LS08-WP-C1 5M | E2B M18 Double distance Shielded 8 mm NPN NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LS08-WP-C2 2M | E2B M18 Double distance Shielded 8 mm NPN NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LS08-WP-C2 5M | E2B M18 Double distance Shielded 8 mm NPN NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LS08-M1-B1 | E2B M18 Double distance Shielded 8 mm PNP NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18LS08-M1-B2 | E2B M18 Double distance Shielded 8 mm PNP NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18LS08-M1-C1 | E2B M18 Double distance Shielded 8 mm NPN NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18LS08-M1-C2 | E2B M18 Double distance Shielded 8 mm NPN NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Shielded | Sensing Distance: 8 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18KN16-WP-B1 2M | E2B M18 Double distance Unshielded 16 mm PNP NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KN16-WP-B1 5M | E2B M18 Double distance Unshielded 16 mm PNP NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KN16-WP-B2 2M | E2B M18 Double distance Unshielded 16 mm PNP NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KN16-WP-B2 5M | E2B M18 Double distance Unshielded 16 mm PNP NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KN16-WP-C1 2M | E2B M18 Double distance Unshielded 16 mm NPN NO Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18KN16-WP-C1 5M | E2B M18 Double distance Unshielded 16 mm NPN NO Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18KN16-WP-C2 2M | E2B M18 Double distance Unshielded 16 mm NPN NC Short 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18KN16-WP-C2 5M | E2B M18 Double distance Unshielded 16 mm NPN NC Short 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18KN16-M1-B1 | E2B M18 Double distance Unshielded 16 mm PNP NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18KN16-M1-B2 | E2B M18 Double distance Unshielded 16 mm PNP NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18KN16-M1-C1 | E2B M18 Double distance Unshielded 16 mm NPN NO Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18KN16-M1-C2 | E2B M18 Double distance Unshielded 16 mm NPN NC Short M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M18LN16-WP-B1 2M | E2B M18 Double distance Unshielded 16 mm PNP NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LN16-WP-B1 5M | E2B M18 Double distance Unshielded 16 mm PNP NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LN16-WP-B2 2M | E2B M18 Double distance Unshielded 16 mm PNP NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LN16-WP-B2 5M | E2B M18 Double distance Unshielded 16 mm PNP NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LN16-WP-C1 2M | E2B M18 Double distance Unshielded 16 mm NPN NO Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M18LN16-WP-C1 5M | E2B M18 Double distance Unshielded 16 mm NPN NO Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M18LN16-WP-C2 2M | E2B M18 Double distance Unshielded 16 mm NPN NC Long 2m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M18LN16-WP-C2 5M | E2B M18 Double distance Unshielded 16 mm NPN NC Long 5m | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M18LN16-M1-B1 | E2B M18 Double distance Unshielded 16 mm PNP NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M18LN16-M1-B2 | E2B M18 Double distance Unshielded 16 mm PNP NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M18LN16-M1-C1 | E2B M18 Double distance Unshielded 16 mm NPN NO Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M18LN16-M1-C2 | E2B M18 Double distance Unshielded 16 mm NPN NC Long M12 Connector | OMRON | Size: M18 | Body Material: Brass | Grade: Double distance | Shield: Unshielded | Sensing Distance: 16 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC |
[OMRON] — E2B M30 Cylindrical Proximity Sensor (Single/Double, Shielded/Unshielded, Brass, PNP/NPN)
▶OMRON E2B Series M30 brass cylindrical proximity sensor. Single: Shielded 10mm / Unshielded 20mm. Double: Shielded 15mm / Unshielded 30mm (Long barrel only). PNP and NPN. NO and NC. Pre-wired 2m/5m and M12 connector.
OMRON E2B Series M30 brass cylindrical proximity sensor. Single: Shielded 10mm / Unshielded 20mm. Double: Shielded 15mm / Unshielded 30mm (Long barrel only). PNP and NPN. NO and NC. Pre-wired 2m/5m and M12 connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2B-M30KS10-WP-B1 2M | E2B M30 Single Shielded 10 mm PNP NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KS10-WP-B1 5M | E2B M30 Single Shielded 10 mm PNP NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KS10-WP-B2 2M | E2B M30 Single Shielded 10 mm PNP NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KS10-WP-B2 5M | E2B M30 Single Shielded 10 mm PNP NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KS10-WP-C1 2M | E2B M30 Single Shielded 10 mm NPN NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KS10-WP-C1 5M | E2B M30 Single Shielded 10 mm NPN NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KS10-WP-C2 2M | E2B M30 Single Shielded 10 mm NPN NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KS10-WP-C2 5M | E2B M30 Single Shielded 10 mm NPN NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KS10-M1-B1 | E2B M30 Single Shielded 10 mm PNP NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30KS10-M1-B2 | E2B M30 Single Shielded 10 mm PNP NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30KS10-M1-C1 | E2B M30 Single Shielded 10 mm NPN NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30KS10-M1-C2 | E2B M30 Single Shielded 10 mm NPN NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30LS10-WP-B1 2M | E2B M30 Single Shielded 10 mm PNP NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LS10-WP-B1 5M | E2B M30 Single Shielded 10 mm PNP NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LS10-WP-B2 2M | E2B M30 Single Shielded 10 mm PNP NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LS10-WP-B2 5M | E2B M30 Single Shielded 10 mm PNP NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LS10-WP-C1 2M | E2B M30 Single Shielded 10 mm NPN NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LS10-WP-C1 5M | E2B M30 Single Shielded 10 mm NPN NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LS10-WP-C2 2M | E2B M30 Single Shielded 10 mm NPN NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LS10-WP-C2 5M | E2B M30 Single Shielded 10 mm NPN NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LS10-M1-B1 | E2B M30 Single Shielded 10 mm PNP NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30LS10-M1-B2 | E2B M30 Single Shielded 10 mm PNP NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30LS10-M1-C1 | E2B M30 Single Shielded 10 mm NPN NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30LS10-M1-C2 | E2B M30 Single Shielded 10 mm NPN NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Shielded | Sensing Distance: 10 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30KN20-WP-B1 2M | E2B M30 Single Unshielded 20 mm PNP NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KN20-WP-B1 5M | E2B M30 Single Unshielded 20 mm PNP NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KN20-WP-B2 2M | E2B M30 Single Unshielded 20 mm PNP NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KN20-WP-B2 5M | E2B M30 Single Unshielded 20 mm PNP NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KN20-WP-C1 2M | E2B M30 Single Unshielded 20 mm NPN NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KN20-WP-C1 5M | E2B M30 Single Unshielded 20 mm NPN NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KN20-WP-C2 2M | E2B M30 Single Unshielded 20 mm NPN NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KN20-WP-C2 5M | E2B M30 Single Unshielded 20 mm NPN NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KN20-M1-B1 | E2B M30 Single Unshielded 20 mm PNP NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30KN20-M1-B2 | E2B M30 Single Unshielded 20 mm PNP NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30KN20-M1-C1 | E2B M30 Single Unshielded 20 mm NPN NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30KN20-M1-C2 | E2B M30 Single Unshielded 20 mm NPN NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30LN20-WP-B1 2M | E2B M30 Single Unshielded 20 mm PNP NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LN20-WP-B1 5M | E2B M30 Single Unshielded 20 mm PNP NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LN20-WP-B2 2M | E2B M30 Single Unshielded 20 mm PNP NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LN20-WP-B2 5M | E2B M30 Single Unshielded 20 mm PNP NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LN20-WP-C1 2M | E2B M30 Single Unshielded 20 mm NPN NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LN20-WP-C1 5M | E2B M30 Single Unshielded 20 mm NPN NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LN20-WP-C2 2M | E2B M30 Single Unshielded 20 mm NPN NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LN20-WP-C2 5M | E2B M30 Single Unshielded 20 mm NPN NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LN20-M1-B1 | E2B M30 Single Unshielded 20 mm PNP NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30LN20-M1-B2 | E2B M30 Single Unshielded 20 mm PNP NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30LN20-M1-C1 | E2B M30 Single Unshielded 20 mm NPN NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30LN20-M1-C2 | E2B M30 Single Unshielded 20 mm NPN NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Single | Shield: Unshielded | Sensing Distance: 20 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30KS15-WP-B1 2M | E2B M30 Double Shielded 15 mm PNP NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KS15-WP-B1 5M | E2B M30 Double Shielded 15 mm PNP NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KS15-WP-B2 2M | E2B M30 Double Shielded 15 mm PNP NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KS15-WP-B2 5M | E2B M30 Double Shielded 15 mm PNP NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KS15-WP-C1 2M | E2B M30 Double Shielded 15 mm NPN NO Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30KS15-WP-C1 5M | E2B M30 Double Shielded 15 mm NPN NO Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30KS15-WP-C2 2M | E2B M30 Double Shielded 15 mm NPN NC Short 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30KS15-WP-C2 5M | E2B M30 Double Shielded 15 mm NPN NC Short 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30KS15-M1-B1 | E2B M30 Double Shielded 15 mm PNP NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30KS15-M1-B2 | E2B M30 Double Shielded 15 mm PNP NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30KS15-M1-C1 | E2B M30 Double Shielded 15 mm NPN NO Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30KS15-M1-C2 | E2B M30 Double Shielded 15 mm NPN NC Short M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Short | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30LS15-WP-B1 2M | E2B M30 Double Shielded 15 mm PNP NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LS15-WP-B1 5M | E2B M30 Double Shielded 15 mm PNP NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LS15-WP-B2 2M | E2B M30 Double Shielded 15 mm PNP NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LS15-WP-B2 5M | E2B M30 Double Shielded 15 mm PNP NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LS15-WP-C1 2M | E2B M30 Double Shielded 15 mm NPN NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LS15-WP-C1 5M | E2B M30 Double Shielded 15 mm NPN NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LS15-WP-C2 2M | E2B M30 Double Shielded 15 mm NPN NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LS15-WP-C2 5M | E2B M30 Double Shielded 15 mm NPN NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LS15-M1-B1 | E2B M30 Double Shielded 15 mm PNP NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30LS15-M1-B2 | E2B M30 Double Shielded 15 mm PNP NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30LS15-M1-C1 | E2B M30 Double Shielded 15 mm NPN NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30LS15-M1-C2 | E2B M30 Double Shielded 15 mm NPN NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Shielded | Sensing Distance: 15 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC | |
| E2B-M30LN30-WP-B1 2M | E2B M30 Double Unshielded 30 mm PNP NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LN30-WP-B1 5M | E2B M30 Double Unshielded 30 mm PNP NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LN30-WP-B2 2M | E2B M30 Double Unshielded 30 mm PNP NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LN30-WP-B2 5M | E2B M30 Double Unshielded 30 mm PNP NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LN30-WP-C1 2M | E2B M30 Double Unshielded 30 mm NPN NO Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-M30LN30-WP-C1 5M | E2B M30 Double Unshielded 30 mm NPN NO Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-M30LN30-WP-C2 2M | E2B M30 Double Unshielded 30 mm NPN NC Long 2m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-M30LN30-WP-C2 5M | E2B M30 Double Unshielded 30 mm NPN NC Long 5m | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-M30LN30-M1-B1 | E2B M30 Double Unshielded 30 mm PNP NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NO | |
| E2B-M30LN30-M1-B2 | E2B M30 Double Unshielded 30 mm PNP NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: M12 Connector | Output: PNP | Operation Mode: NC | |
| E2B-M30LN30-M1-C1 | E2B M30 Double Unshielded 30 mm NPN NO Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NO | |
| E2B-M30LN30-M1-C2 | E2B M30 Double Unshielded 30 mm NPN NC Long M12 Connector | OMRON | Size: M30 | Body Material: Brass | Grade: Double | Shield: Unshielded | Sensing Distance: 30 mm | Barrel: Long | Connection: M12 Connector | Output: NPN | Operation Mode: NC |
OMRON E2B Series M8 stainless steel cylindrical proximity sensor. Single: Shielded 1.5mm / Unshielded 2mm. Double: Shielded 2mm / Unshielded 4mm. Short and Long barrel. PNP and NPN. NO and NC. Pre-wired 2m/5m and M8 connector (3-pin).
OMRON E2B Series M8 stainless steel cylindrical proximity sensor. Single: Shielded 1.5mm / Unshielded 2mm. Double: Shielded 2mm / Unshielded 4mm. Short and Long barrel. PNP and NPN. NO and NC. Pre-wired 2m/5m and M8 connector (3-pin).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2B-S08KS01-WP-B1 2M | E2B M08 Single distance Shielded 1.5 mm PNP NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KS01-WP-B1 5M | E2B M08 Single distance Shielded 1.5 mm PNP NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KS01-WP-B2 2M | E2B M08 Single distance Shielded 1.5 mm PNP NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KS01-WP-B2 5M | E2B M08 Single distance Shielded 1.5 mm PNP NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KS01-WP-C1 2M | E2B M08 Single distance Shielded 1.5 mm NPN NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KS01-WP-C1 5M | E2B M08 Single distance Shielded 1.5 mm NPN NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KS01-WP-C2 2M | E2B M08 Single distance Shielded 1.5 mm NPN NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KS01-WP-C2 5M | E2B M08 Single distance Shielded 1.5 mm NPN NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KS01-MC-B1 | E2B M08 Single distance Shielded 1.5 mm PNP NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08KS01-MC-B2 | E2B M08 Single distance Shielded 1.5 mm PNP NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08KS01-MC-C1 | E2B M08 Single distance Shielded 1.5 mm NPN NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08KS01-MC-C2 | E2B M08 Single distance Shielded 1.5 mm NPN NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08LS01-WP-B1 2M | E2B M08 Single distance Shielded 1.5 mm PNP NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LS01-WP-B1 5M | E2B M08 Single distance Shielded 1.5 mm PNP NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LS01-WP-B2 2M | E2B M08 Single distance Shielded 1.5 mm PNP NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LS01-WP-B2 5M | E2B M08 Single distance Shielded 1.5 mm PNP NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LS01-WP-C1 2M | E2B M08 Single distance Shielded 1.5 mm NPN NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LS01-WP-C1 5M | E2B M08 Single distance Shielded 1.5 mm NPN NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LS01-WP-C2 2M | E2B M08 Single distance Shielded 1.5 mm NPN NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LS01-WP-C2 5M | E2B M08 Single distance Shielded 1.5 mm NPN NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LS01-MC-B1 | E2B M08 Single distance Shielded 1.5 mm PNP NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08LS01-MC-B2 | E2B M08 Single distance Shielded 1.5 mm PNP NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08LS01-MC-C1 | E2B M08 Single distance Shielded 1.5 mm NPN NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08LS01-MC-C2 | E2B M08 Single distance Shielded 1.5 mm NPN NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Shielded | Sensing Distance: 1.5 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08KN02-WP-B1 2M | E2B M08 Single distance Unshielded 2 mm PNP NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KN02-WP-B1 5M | E2B M08 Single distance Unshielded 2 mm PNP NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KN02-WP-B2 2M | E2B M08 Single distance Unshielded 2 mm PNP NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KN02-WP-B2 5M | E2B M08 Single distance Unshielded 2 mm PNP NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KN02-WP-C1 2M | E2B M08 Single distance Unshielded 2 mm NPN NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KN02-WP-C1 5M | E2B M08 Single distance Unshielded 2 mm NPN NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KN02-WP-C2 2M | E2B M08 Single distance Unshielded 2 mm NPN NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KN02-WP-C2 5M | E2B M08 Single distance Unshielded 2 mm NPN NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KN02-MC-B1 | E2B M08 Single distance Unshielded 2 mm PNP NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08KN02-MC-B2 | E2B M08 Single distance Unshielded 2 mm PNP NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08KN02-MC-C1 | E2B M08 Single distance Unshielded 2 mm NPN NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08KN02-MC-C2 | E2B M08 Single distance Unshielded 2 mm NPN NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08LN02-WP-B1 2M | E2B M08 Single distance Unshielded 2 mm PNP NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LN02-WP-B1 5M | E2B M08 Single distance Unshielded 2 mm PNP NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LN02-WP-B2 2M | E2B M08 Single distance Unshielded 2 mm PNP NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LN02-WP-B2 5M | E2B M08 Single distance Unshielded 2 mm PNP NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LN02-WP-C1 2M | E2B M08 Single distance Unshielded 2 mm NPN NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LN02-WP-C1 5M | E2B M08 Single distance Unshielded 2 mm NPN NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LN02-WP-C2 2M | E2B M08 Single distance Unshielded 2 mm NPN NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LN02-WP-C2 5M | E2B M08 Single distance Unshielded 2 mm NPN NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LN02-MC-B1 | E2B M08 Single distance Unshielded 2 mm PNP NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08LN02-MC-B2 | E2B M08 Single distance Unshielded 2 mm PNP NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08LN02-MC-C1 | E2B M08 Single distance Unshielded 2 mm NPN NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08LN02-MC-C2 | E2B M08 Single distance Unshielded 2 mm NPN NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Single distance | Shield: Unshielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08KS02-WP-B1 2M | E2B M08 Double distance Shielded 2 mm PNP NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KS02-WP-B1 5M | E2B M08 Double distance Shielded 2 mm PNP NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KS02-WP-B2 2M | E2B M08 Double distance Shielded 2 mm PNP NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KS02-WP-B2 5M | E2B M08 Double distance Shielded 2 mm PNP NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KS02-WP-C1 2M | E2B M08 Double distance Shielded 2 mm NPN NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KS02-WP-C1 5M | E2B M08 Double distance Shielded 2 mm NPN NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KS02-WP-C2 2M | E2B M08 Double distance Shielded 2 mm NPN NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KS02-WP-C2 5M | E2B M08 Double distance Shielded 2 mm NPN NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KS02-MC-B1 | E2B M08 Double distance Shielded 2 mm PNP NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08KS02-MC-B2 | E2B M08 Double distance Shielded 2 mm PNP NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08KS02-MC-C1 | E2B M08 Double distance Shielded 2 mm NPN NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08KS02-MC-C2 | E2B M08 Double distance Shielded 2 mm NPN NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08LS02-WP-B1 2M | E2B M08 Double distance Shielded 2 mm PNP NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LS02-WP-B1 5M | E2B M08 Double distance Shielded 2 mm PNP NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LS02-WP-B2 2M | E2B M08 Double distance Shielded 2 mm PNP NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LS02-WP-B2 5M | E2B M08 Double distance Shielded 2 mm PNP NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LS02-WP-C1 2M | E2B M08 Double distance Shielded 2 mm NPN NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LS02-WP-C1 5M | E2B M08 Double distance Shielded 2 mm NPN NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LS02-WP-C2 2M | E2B M08 Double distance Shielded 2 mm NPN NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LS02-WP-C2 5M | E2B M08 Double distance Shielded 2 mm NPN NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LS02-MC-B1 | E2B M08 Double distance Shielded 2 mm PNP NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08LS02-MC-B2 | E2B M08 Double distance Shielded 2 mm PNP NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08LS02-MC-C1 | E2B M08 Double distance Shielded 2 mm NPN NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08LS02-MC-C2 | E2B M08 Double distance Shielded 2 mm NPN NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Shielded | Sensing Distance: 2 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08KN04-WP-B1 2M | E2B M08 Double distance Unshielded 4 mm PNP NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KN04-WP-B1 5M | E2B M08 Double distance Unshielded 4 mm PNP NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KN04-WP-B2 2M | E2B M08 Double distance Unshielded 4 mm PNP NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KN04-WP-B2 5M | E2B M08 Double distance Unshielded 4 mm PNP NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KN04-WP-C1 2M | E2B M08 Double distance Unshielded 4 mm NPN NO Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08KN04-WP-C1 5M | E2B M08 Double distance Unshielded 4 mm NPN NO Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08KN04-WP-C2 2M | E2B M08 Double distance Unshielded 4 mm NPN NC Short 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08KN04-WP-C2 5M | E2B M08 Double distance Unshielded 4 mm NPN NC Short 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08KN04-MC-B1 | E2B M08 Double distance Unshielded 4 mm PNP NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08KN04-MC-B2 | E2B M08 Double distance Unshielded 4 mm PNP NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08KN04-MC-C1 | E2B M08 Double distance Unshielded 4 mm NPN NO Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08KN04-MC-C2 | E2B M08 Double distance Unshielded 4 mm NPN NC Short M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Short | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC | |
| E2B-S08LN04-WP-B1 2M | E2B M08 Double distance Unshielded 4 mm PNP NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LN04-WP-B1 5M | E2B M08 Double distance Unshielded 4 mm PNP NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LN04-WP-B2 2M | E2B M08 Double distance Unshielded 4 mm PNP NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LN04-WP-B2 5M | E2B M08 Double distance Unshielded 4 mm PNP NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: PNP | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LN04-WP-C1 2M | E2B M08 Double distance Unshielded 4 mm NPN NO Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 2 m | |
| E2B-S08LN04-WP-C1 5M | E2B M08 Double distance Unshielded 4 mm NPN NO Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NO | Cable: Pre-wired 5 m | |
| E2B-S08LN04-WP-C2 2M | E2B M08 Double distance Unshielded 4 mm NPN NC Long 2m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 2 m | |
| E2B-S08LN04-WP-C2 5M | E2B M08 Double distance Unshielded 4 mm NPN NC Long 5m | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: Pre-wired | Output: NPN | Operation Mode: NC | Cable: Pre-wired 5 m | |
| E2B-S08LN04-MC-B1 | E2B M08 Double distance Unshielded 4 mm PNP NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NO | |
| E2B-S08LN04-MC-B2 | E2B M08 Double distance Unshielded 4 mm PNP NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: PNP | Operation Mode: NC | |
| E2B-S08LN04-MC-C1 | E2B M08 Double distance Unshielded 4 mm NPN NO Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NO | |
| E2B-S08LN04-MC-C2 | E2B M08 Double distance Unshielded 4 mm NPN NC Long M8 Connector (3-pin) | OMRON | Size: M08 | Body Material: Stainless steel | Grade: Double distance | Shield: Unshielded | Sensing Distance: 4 mm | Barrel: Long | Connection: M8 Connector (3-pin) | Output: NPN | Operation Mode: NC |
[OMRON] — E2CY-SD Non-ferrous-metal-detecting Proximity Sensor Amplifier Unit (NPN/PNP, DC 3-Wire)
▶OMRON E2CY-SD Series amplifier units for non-ferrous metal detection. DC 3-wire. E2CY-SD11: NPN open collector. E2CY-SD41: PNP open collector. Cable 2m.
OMRON E2CY-SD Series amplifier units for non-ferrous metal detection. DC 3-wire. E2CY-SD11: NPN open collector. E2CY-SD41: PNP open collector. Cable 2m.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2CY-SD11 2M | Non-ferrous amplifier NPN DC 3-wire 2m | OMRON | Type: Amplifier Unit | Wire: DC 3-wire | Output: NPN open collector | Cable: 2 m | Compatible Heads: E2CY-X1R5A/C1R5A-1/C2A/V3A/C2AF | |
| E2CY-SD41 2M | Non-ferrous amplifier PNP DC 3-wire 2m | OMRON | Type: Amplifier Unit | Wire: DC 3-wire | Output: PNP open collector | Cable: 2 m | Compatible Heads: E2CY-X1R5A/C1R5A-1/C2A/V3A/C2AF |
OMRON E2CY-SD Series non-ferrous-metal-detecting proximity sensor heads. Detects aluminum, copper, stainless steel. Shielded. Cable 3m. M5 (1.5mm), 5.4dia (1.5mm), 8dia (2mm), Flat (3mm). Requires E2CY-SD11 (NPN) or E2CY-SD41 (PNP) amplifier.
OMRON E2CY-SD Series non-ferrous-metal-detecting proximity sensor heads. Detects aluminum, copper, stainless steel. Shielded. Cable 3m. M5 (1.5mm), 5.4dia (1.5mm), 8dia (2mm), Flat (3mm). Requires E2CY-SD11 (NPN) or E2CY-SD41 (PNP) amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2CY-X1R5A 3M | M5 1.5mm shielded 3m | OMRON | Type: Shielded M5 screw | Sensing Distance: 1.5 mm (stable) | Detection: Non-ferrous metals: aluminum, copper, stainless steel | Cable: 3 m | Required Amplifier: E2CY-SD11 (NPN) or E2CY-SD41 (PNP) | |
| E2CY-C1R5A-1 3M | 5.4dia 1.5mm shielded 3m | OMRON | Type: Shielded Cylindrical 5.4 dia. | Sensing Distance: 1.5 mm (stable) | Detection: Non-ferrous metals | Cable: 3 m | Required Amplifier: E2CY-SD11 (NPN) or E2CY-SD41 (PNP) | |
| E2CY-C2A 3M | 8dia 2mm shielded 3m | OMRON | Type: Shielded Cylindrical 8 dia. | Sensing Distance: 2 mm (stable) | Detection: Non-ferrous metals | Cable: 3 m | Required Amplifier: E2CY-SD11 (NPN) or E2CY-SD41 (PNP) | |
| E2CY-V3A 3M | Flat 3mm shielded 3m | OMRON | Type: Shielded Flat | Sensing Distance: 3 mm (stable) | Detection: Non-ferrous metals | Cable: 3 m | Required Amplifier: E2CY-SD11 (NPN) or E2CY-SD41 (PNP) | |
| E2CY-C2AF 3M | 8dia 2mm shielded 3m variant | OMRON | Type: Shielded Cylindrical 8 dia. (F variant) | Sensing Distance: 2 mm (stable) | Detection: Non-ferrous metals | Cable: 3 m | Required Amplifier: E2CY-SD11 (NPN) or E2CY-SD41 (PNP) |
OMRON E2E Series AC 2-wire shielded proximity sensors. M12 (2mm), M18 (5mm), M30 (10mm). NO and NC. PVC oil-resistant cable. Pre-wired 2m and M12 connector. UL and frequency variants also available.
OMRON E2E Series AC 2-wire shielded proximity sensors. M12 (2mm), M18 (5mm), M30 (10mm). NO and NC. PVC oil-resistant cable. Pre-wired 2m and M12 connector. UL and frequency variants also available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X2Y1 2M | AC 2W shielded M12 2 mm NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X2Y1-M1 | AC 2W shielded M12 2 mm NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X2Y2 2M | AC 2W shielded M12 2 mm NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X2Y2-M1 | AC 2W shielded M12 2 mm NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) | |
| E2E-X5Y1 2M | AC 2W shielded M18 5 mm NO 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X5Y1-M1 | AC 2W shielded M18 5 mm NO M12 conn | OMRON | Size: M18 | Sensing Distance: 5 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X5Y2 2M | AC 2W shielded M18 5 mm NC 2m | OMRON | Size: M18 | Sensing Distance: 5 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X5Y2-M1 | AC 2W shielded M18 5 mm NC M12 conn | OMRON | Size: M18 | Sensing Distance: 5 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) | |
| E2E-X10Y1 2M | AC 2W shielded M30 10 mm NO 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X10Y1-M1 | AC 2W shielded M30 10 mm NO M12 conn | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X10Y2 2M | AC 2W shielded M30 10 mm NC 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: Pre-wired 2 m | |
| E2E-X10Y2-M1 | AC 2W shielded M30 10 mm NC M12 conn | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]Y[]5; UL model: E2E-X[]Y[]-US; M4 conn: E2E-X[]Y[]-M4 | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) |
OMRON E2E Series AC 2-wire unshielded proximity sensors. M12 (5mm), M18 (10mm), M30 (18mm). NO and NC. PVC oil-resistant cable. Pre-wired 2m and M12 connector. UL and frequency variants also available.
OMRON E2E Series AC 2-wire unshielded proximity sensors. M12 (5mm), M18 (10mm), M30 (18mm). NO and NC. PVC oil-resistant cable. Pre-wired 2m and M12 connector. UL and frequency variants also available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X5MY1 2M | AC 2W unshielded M12 5 mm NO 2m | OMRON | Size: M12 | Sensing Distance: 5 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X5MY1-M1 | AC 2W unshielded M12 5 mm NO M12 conn | OMRON | Size: M12 | Sensing Distance: 5 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X5MY2 2M | AC 2W unshielded M12 5 mm NC 2m | OMRON | Size: M12 | Sensing Distance: 5 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X5MY2-M1 | AC 2W unshielded M12 5 mm NC M12 conn | OMRON | Size: M12 | Sensing Distance: 5 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) | |
| E2E-X10MY1 2M | AC 2W unshielded M18 10 mm NO 2m | OMRON | Size: M18 | Sensing Distance: 10 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X10MY1-M1 | AC 2W unshielded M18 10 mm NO M12 conn | OMRON | Size: M18 | Sensing Distance: 10 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X10MY2 2M | AC 2W unshielded M18 10 mm NC 2m | OMRON | Size: M18 | Sensing Distance: 10 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X10MY2-M1 | AC 2W unshielded M18 10 mm NC M12 conn | OMRON | Size: M18 | Sensing Distance: 10 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) | |
| E2E-X18MY1 2M | AC 2W unshielded M30 18 mm NO 2m | OMRON | Size: M30 | Sensing Distance: 18 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X18MY1-M1 | AC 2W unshielded M30 18 mm NO M12 conn | OMRON | Size: M30 | Sensing Distance: 18 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (3, 4): (AC, AC) | |
| E2E-X18MY2 2M | AC 2W unshielded M30 18 mm NC 2m | OMRON | Size: M30 | Sensing Distance: 18 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: Pre-wired 2 m | |
| E2E-X18MY2-M1 | AC 2W unshielded M30 18 mm NC M12 conn | OMRON | Size: M30 | Sensing Distance: 18 mm | Shield: Unshielded | Wire: AC 2-wire | Cable: PVC oil-resistant | Operation Mode: NC | Note: Freq variant: E2E-X[]MY[]5; UL model: E2E-X[]MY[]-US | Connection: M12 Connector | Pin Arrangement: (1, 2): (AC, AC) |
OMRON E2E Series AC/DC 2-wire shielded proximity sensors. M12 (3mm), M18 (7mm), M30 (10mm). NO only. PVC oil-resistant cable. Pre-wired 2m. No unshielded models available.
OMRON E2E Series AC/DC 2-wire shielded proximity sensors. M12 (3mm), M18 (7mm), M30 (10mm). NO only. PVC oil-resistant cable. Pre-wired 2m. No unshielded models available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X3T1 2M | AC/DC 2W shielded M12 3 mm NO 2m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: AC/DC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: No unshielded models available | Connection: Pre-wired 2 m | |
| E2E-X7T1 2M | AC/DC 2W shielded M18 7 mm NO 2m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: AC/DC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: No unshielded models available | Connection: Pre-wired 2 m | |
| E2E-X10T1 2M | AC/DC 2W shielded M30 10 mm NO 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: AC/DC 2-wire | Cable: PVC oil-resistant | Operation Mode: NO | Note: No unshielded models available | Connection: Pre-wired 2 m |
OMRON E2E Series DC 2-wire shielded proximity sensors with PUR (polyurethane) cable. M8 (2mm), M12 (3mm), M18 (7mm), M30 (10mm). NO and NC. Pre-wired 2m and M12 Smartclick connector 0.3m.
OMRON E2E Series DC 2-wire shielded proximity sensors with PUR (polyurethane) cable. M8 (2mm), M12 (3mm), M18 (7mm), M30 (10mm). NO and NC. Pre-wired 2m and M12 Smartclick connector 0.3m.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X2D1-U 2M | DC 2W PUR M8 2 mm NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X2D1-M1TGJ-U 0.3M | DC 2W PUR M8 2 mm NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 4: 0 V | |
| E2E-X2D2-U 2M | DC 2W PUR M8 2 mm NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X2D2-M1TGJ-U 0.3M | DC 2W PUR M8 2 mm NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 2: 0 V | |
| E2E-X3D1-U 2M | DC 2W PUR M12 3 mm NO 2m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X3D1-M1TGJ-U 0.3M | DC 2W PUR M12 3 mm NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 4: 0 V | |
| E2E-X3D2-U 2M | DC 2W PUR M12 3 mm NC 2m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X3D2-M1TGJ-U 0.3M | DC 2W PUR M12 3 mm NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 2: 0 V | |
| E2E-X7D1-U 2M | DC 2W PUR M18 7 mm NO 2m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X7D1-M1TGJ-U 0.3M | DC 2W PUR M18 7 mm NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 4: 0 V | |
| E2E-X7D2-U 2M | DC 2W PUR M18 7 mm NC 2m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X7D2-M1TGJ-U 0.3M | DC 2W PUR M18 7 mm NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 2: 0 V | |
| E2E-X10D1-U 2M | DC 2W PUR M30 10 mm NO 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X10D1-M1TGJ-U 0.3M | DC 2W PUR M30 10 mm NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NO | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 4: 0 V | |
| E2E-X10D2-U 2M | DC 2W PUR M30 10 mm NC 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: Pre-wired 2 m | |
| E2E-X10D2-M1TGJ-U 0.3M | DC 2W PUR M30 10 mm NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire | Cable: PUR (polyurethane) | Polarity: Yes | Operation Mode: NC | Note: DC 3W/2W standard models integrated into E2E NEXT Series | Connection: M12 Pre-wired Smartclick Connector 0.3 m | Pin Arrangement: 1: +V, 2: 0 V |
OMRON E2E Series DC 2-wire shielded proximity sensors with self-diagnosis output. M12 (3mm), M18 (7mm), M30 (10mm). NO only. PVC oil-resistant cable. Pre-wired 2m and M12 connector. Frequency variant models also available.
OMRON E2E Series DC 2-wire shielded proximity sensors with self-diagnosis output. M12 (3mm), M18 (7mm), M30 (10mm). NO only. PVC oil-resistant cable. Pre-wired 2m and M12 connector. Frequency variant models also available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X3D1S 2M | DC 2W self-diag shielded M12 3 mm 2m | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: Pre-wired 2 m | |
| E2E-X3D1S-M1 | DC 2W self-diag shielded M12 3 mm M12 conn | OMRON | Size: M12 | Sensing Distance: 3 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: M12 Connector | |
| E2E-X7D1S 2M | DC 2W self-diag shielded M18 7 mm 2m | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: Pre-wired 2 m | |
| E2E-X7D1S-M1 | DC 2W self-diag shielded M18 7 mm M12 conn | OMRON | Size: M18 | Sensing Distance: 7 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: M12 Connector | |
| E2E-X10D1S 2M | DC 2W self-diag shielded M30 10 mm 2m | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: Pre-wired 2 m | |
| E2E-X10D1S-M1 | DC 2W self-diag shielded M30 10 mm M12 conn | OMRON | Size: M30 | Sensing Distance: 10 mm | Shield: Shielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]D15S (add '5' before 'S') | Connection: M12 Connector |
OMRON E2E Series DC 2-wire unshielded proximity sensors with self-diagnosis output. M12 (8mm), M18 (14mm), M30 (20mm). NO only. PVC oil-resistant cable. Pre-wired 2m and M12 connector. Frequency variant models also available.
OMRON E2E Series DC 2-wire unshielded proximity sensors with self-diagnosis output. M12 (8mm), M18 (14mm), M30 (20mm). NO only. PVC oil-resistant cable. Pre-wired 2m and M12 connector. Frequency variant models also available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X8MD1S 2M | DC 2W self-diag unshielded M12 8 mm 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: Pre-wired 2 m | |
| E2E-X8MD1S-M1 | DC 2W self-diag unshielded M12 8 mm M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: M12 Connector | |
| E2E-X14MD1S 2M | DC 2W self-diag unshielded M18 14 mm 2m | OMRON | Size: M18 | Sensing Distance: 14 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: Pre-wired 2 m | |
| E2E-X14MD1S-M1 | DC 2W self-diag unshielded M18 14 mm M12 conn | OMRON | Size: M18 | Sensing Distance: 14 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: M12 Connector | |
| E2E-X20MD1S 2M | DC 2W self-diag unshielded M30 20 mm 2m | OMRON | Size: M30 | Sensing Distance: 20 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: Pre-wired 2 m | |
| E2E-X20MD1S-M1 | DC 2W self-diag unshielded M30 20 mm M12 conn | OMRON | Size: M30 | Sensing Distance: 20 mm | Shield: Unshielded | Wire: DC 2-wire with self-diagnosis output | Cable: PVC oil-resistant | Polarity: Yes | Operation Mode: NO | Pin: 2: +V and diagnostic output / 3: 0V / 4: +V and control output | Note: Frequency variant available: E2E-X[]MD15S | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M12 body, Shielded. Sensing distance 4 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M12 body, Shielded. Sensing distance 4 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X4B1T12 2M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4B1T12 5M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4B1T12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B1T12-M1 | E2E NEXT M12 4 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4B1D12 2M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4B1D12 5M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4B1D12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B1D12-M1 | E2E NEXT M12 4 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4C112 2M | E2E NEXT M12 4 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4C112 5M | E2E NEXT M12 4 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4C112-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C112-M1 | E2E NEXT M12 4 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4B212 2M | E2E NEXT M12 4 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4B212 5M | E2E NEXT M12 4 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4B212-M1TJ 0.3M | E2E NEXT M12 4 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B212-M1 | E2E NEXT M12 4 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4C212 2M | E2E NEXT M12 4 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4C212 5M | E2E NEXT M12 4 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4C212-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C212-M1 | E2E NEXT M12 4 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4B3D12 2M | E2E NEXT M12 4 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4B3D12 5M | E2E NEXT M12 4 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4B3D12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B3D12-M1 | E2E NEXT M12 4 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X4C312 2M | E2E NEXT M12 4 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4C312 5M | E2E NEXT M12 4 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4C312-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C312-M1 | E2E NEXT M12 4 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X4B1TL12 2M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4B1TL12 5M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4B1TL12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B1TL12-M1 | E2E NEXT M12 4 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4B1DL12 2M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4B1DL12 5M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4B1DL12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B1DL12-M1 | E2E NEXT M12 4 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4C1L12 2M | E2E NEXT M12 4 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4C1L12 5M | E2E NEXT M12 4 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4C1L12-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C1L12-M1 | E2E NEXT M12 4 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4B2L12 2M | E2E NEXT M12 4 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4B2L12 5M | E2E NEXT M12 4 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4B2L12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B2L12-M1 | E2E NEXT M12 4 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4C2L12 2M | E2E NEXT M12 4 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4C2L12 5M | E2E NEXT M12 4 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4C2L12-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C2L12-M1 | E2E NEXT M12 4 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4B3DL12 2M | E2E NEXT M12 4 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4B3DL12 5M | E2E NEXT M12 4 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4B3DL12-M1TJ 0.3M | E2E NEXT M12 4 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4B3DL12-M1 | E2E NEXT M12 4 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X4C3L12 2M | E2E NEXT M12 4 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4C3L12 5M | E2E NEXT M12 4 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4C3L12-M1TJ 0.3M | E2E NEXT M12 4 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4C3L12-M1 | E2E NEXT M12 4 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 4 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M12 body, Unshielded. Sensing distance 8 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M12 body, Unshielded. Sensing distance 8 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X8MBB1T12 2M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBB1T12 5M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBB1T12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB1T12-M1 | E2E NEXT M12 8 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBB1D12 2M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBB1D12 5M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBB1D12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB1D12-M1 | E2E NEXT M12 8 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBC112 2M | E2E NEXT M12 8 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBC112 5M | E2E NEXT M12 8 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBC112-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC112-M1 | E2E NEXT M12 8 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBB212 2M | E2E NEXT M12 8 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8MBB212 5M | E2E NEXT M12 8 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8MBB212-M1TJ 0.3M | E2E NEXT M12 8 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB212-M1 | E2E NEXT M12 8 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8MBC212 2M | E2E NEXT M12 8 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8MBC212 5M | E2E NEXT M12 8 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8MBC212-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC212-M1 | E2E NEXT M12 8 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8MBB3D12 2M | E2E NEXT M12 8 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8MBB3D12 5M | E2E NEXT M12 8 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8MBB3D12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB3D12-M1 | E2E NEXT M12 8 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8MBC312 2M | E2E NEXT M12 8 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8MBC312 5M | E2E NEXT M12 8 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8MBC312-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC312-M1 | E2E NEXT M12 8 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8MBB1TL12 2M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBB1TL12 5M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBB1TL12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB1TL12-M1 | E2E NEXT M12 8 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBB1DL12 2M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBB1DL12 5M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBB1DL12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB1DL12-M1 | E2E NEXT M12 8 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBC1L12 2M | E2E NEXT M12 8 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8MBC1L12 5M | E2E NEXT M12 8 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8MBC1L12-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC1L12-M1 | E2E NEXT M12 8 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8MBB2L12 2M | E2E NEXT M12 8 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8MBB2L12 5M | E2E NEXT M12 8 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8MBB2L12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB2L12-M1 | E2E NEXT M12 8 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8MBC2L12 2M | E2E NEXT M12 8 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8MBC2L12 5M | E2E NEXT M12 8 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8MBC2L12-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC2L12-M1 | E2E NEXT M12 8 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8MBB3DL12 2M | E2E NEXT M12 8 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8MBB3DL12 5M | E2E NEXT M12 8 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8MBB3DL12-M1TJ 0.3M | E2E NEXT M12 8 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBB3DL12-M1 | E2E NEXT M12 8 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8MBC3L12 2M | E2E NEXT M12 8 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8MBC3L12 5M | E2E NEXT M12 8 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8MBC3L12-M1TJ 0.3M | E2E NEXT M12 8 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8MBC3L12-M1 | E2E NEXT M12 8 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 8 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M18 body, Shielded. Sensing distance 8 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M18 body, Shielded. Sensing distance 8 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X8B1T18 2M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8B1T18 5M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8B1T18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B1T18-M1 | E2E NEXT M18 8 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8B1D18 2M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8B1D18 5M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8B1D18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B1D18-M1 | E2E NEXT M18 8 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8C118 2M | E2E NEXT M18 8 mm NPN NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8C118 5M | E2E NEXT M18 8 mm NPN NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8C118-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C118-M1 | E2E NEXT M18 8 mm NPN NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8B218 2M | E2E NEXT M18 8 mm PNP NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8B218 5M | E2E NEXT M18 8 mm PNP NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8B218-M1TJ 0.3M | E2E NEXT M18 8 mm PNP NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B218-M1 | E2E NEXT M18 8 mm PNP NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8C218 2M | E2E NEXT M18 8 mm NPN NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8C218 5M | E2E NEXT M18 8 mm NPN NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8C218-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C218-M1 | E2E NEXT M18 8 mm NPN NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8B3D18 2M | E2E NEXT M18 8 mm PNP NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8B3D18 5M | E2E NEXT M18 8 mm PNP NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8B3D18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B3D18-M1 | E2E NEXT M18 8 mm PNP NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8C318 2M | E2E NEXT M18 8 mm NPN NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8C318 5M | E2E NEXT M18 8 mm NPN NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8C318-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C318-M1 | E2E NEXT M18 8 mm NPN NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8B1TL18 2M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8B1TL18 5M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8B1TL18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B1TL18-M1 | E2E NEXT M18 8 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8B1DL18 2M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8B1DL18 5M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8B1DL18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B1DL18-M1 | E2E NEXT M18 8 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8C1L18 2M | E2E NEXT M18 8 mm NPN NO 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X8C1L18 5M | E2E NEXT M18 8 mm NPN NO 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X8C1L18-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C1L18-M1 | E2E NEXT M18 8 mm NPN NO M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X8B2L18 2M | E2E NEXT M18 8 mm PNP NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8B2L18 5M | E2E NEXT M18 8 mm PNP NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8B2L18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B2L18-M1 | E2E NEXT M18 8 mm PNP NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8C2L18 2M | E2E NEXT M18 8 mm NPN NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X8C2L18 5M | E2E NEXT M18 8 mm NPN NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X8C2L18-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C2L18-M1 | E2E NEXT M18 8 mm NPN NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X8B3DL18 2M | E2E NEXT M18 8 mm PNP NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8B3DL18 5M | E2E NEXT M18 8 mm PNP NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8B3DL18-M1TJ 0.3M | E2E NEXT M18 8 mm PNP NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8B3DL18-M1 | E2E NEXT M18 8 mm PNP NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X8C3L18 2M | E2E NEXT M18 8 mm NPN NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X8C3L18 5M | E2E NEXT M18 8 mm NPN NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X8C3L18-M1TJ 0.3M | E2E NEXT M18 8 mm NPN NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X8C3L18-M1 | E2E NEXT M18 8 mm NPN NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 8 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M18 body, Unshielded. Sensing distance 16 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M18 body, Unshielded. Sensing distance 16 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X16MBB1T18 2M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBB1T18 5M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBB1T18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB1T18-M1 | E2E NEXT M18 16 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBB1D18 2M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBB1D18 5M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBB1D18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB1D18-M1 | E2E NEXT M18 16 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBC118 2M | E2E NEXT M18 16 mm NPN NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBC118 5M | E2E NEXT M18 16 mm NPN NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBC118-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC118-M1 | E2E NEXT M18 16 mm NPN NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBB218 2M | E2E NEXT M18 16 mm PNP NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X16MBB218 5M | E2E NEXT M18 16 mm PNP NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X16MBB218-M1TJ 0.3M | E2E NEXT M18 16 mm PNP NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB218-M1 | E2E NEXT M18 16 mm PNP NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X16MBC218 2M | E2E NEXT M18 16 mm NPN NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X16MBC218 5M | E2E NEXT M18 16 mm NPN NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X16MBC218-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC218-M1 | E2E NEXT M18 16 mm NPN NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X16MBB3D18 2M | E2E NEXT M18 16 mm PNP NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X16MBB3D18 5M | E2E NEXT M18 16 mm PNP NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X16MBB3D18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB3D18-M1 | E2E NEXT M18 16 mm PNP NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X16MBC318 2M | E2E NEXT M18 16 mm NPN NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X16MBC318 5M | E2E NEXT M18 16 mm NPN NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X16MBC318-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC318-M1 | E2E NEXT M18 16 mm NPN NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X16MBB1TL18 2M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBB1TL18 5M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBB1TL18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB1TL18-M1 | E2E NEXT M18 16 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBB1DL18 2M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBB1DL18 5M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBB1DL18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB1DL18-M1 | E2E NEXT M18 16 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBC1L18 2M | E2E NEXT M18 16 mm NPN NO 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X16MBC1L18 5M | E2E NEXT M18 16 mm NPN NO 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X16MBC1L18-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NO Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC1L18-M1 | E2E NEXT M18 16 mm NPN NO M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X16MBB2L18 2M | E2E NEXT M18 16 mm PNP NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X16MBB2L18 5M | E2E NEXT M18 16 mm PNP NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X16MBB2L18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB2L18-M1 | E2E NEXT M18 16 mm PNP NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X16MBC2L18 2M | E2E NEXT M18 16 mm NPN NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X16MBC2L18 5M | E2E NEXT M18 16 mm NPN NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X16MBC2L18-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NC Smartclick 0.3m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC2L18-M1 | E2E NEXT M18 16 mm NPN NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X16MBB3DL18 2M | E2E NEXT M18 16 mm PNP NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X16MBB3DL18 5M | E2E NEXT M18 16 mm PNP NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X16MBB3DL18-M1TJ 0.3M | E2E NEXT M18 16 mm PNP NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBB3DL18-M1 | E2E NEXT M18 16 mm PNP NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X16MBC3L18 2M | E2E NEXT M18 16 mm NPN NO+NC 2m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X16MBC3L18 5M | E2E NEXT M18 16 mm NPN NO+NC 5m | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X16MBC3L18-M1TJ 0.3M | E2E NEXT M18 16 mm NPN NO+NC Smartclick | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X16MBC3L18-M1 | E2E NEXT M18 16 mm NPN NO+NC M12 conn | OMRON | Size: M18 | Sensing Distance: 16 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M30 body, Shielded. Sensing distance 15 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M30 body, Shielded. Sensing distance 15 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X15B1T30 2M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15B1T30 5M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15B1T30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B1T30-M1 | E2E NEXT M30 15 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15B1D30 2M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15B1D30 5M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15B1D30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B1D30-M1 | E2E NEXT M30 15 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15C130 2M | E2E NEXT M30 15 mm NPN NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15C130 5M | E2E NEXT M30 15 mm NPN NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15C130-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C130-M1 | E2E NEXT M30 15 mm NPN NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15B230 2M | E2E NEXT M30 15 mm PNP NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X15B230 5M | E2E NEXT M30 15 mm PNP NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X15B230-M1TJ 0.3M | E2E NEXT M30 15 mm PNP NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B230-M1 | E2E NEXT M30 15 mm PNP NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X15C230 2M | E2E NEXT M30 15 mm NPN NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X15C230 5M | E2E NEXT M30 15 mm NPN NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X15C230-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C230-M1 | E2E NEXT M30 15 mm NPN NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X15B3D30 2M | E2E NEXT M30 15 mm PNP NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X15B3D30 5M | E2E NEXT M30 15 mm PNP NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X15B3D30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B3D30-M1 | E2E NEXT M30 15 mm PNP NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X15C330 2M | E2E NEXT M30 15 mm NPN NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X15C330 5M | E2E NEXT M30 15 mm NPN NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X15C330-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C330-M1 | E2E NEXT M30 15 mm NPN NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X15B1TL30 2M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15B1TL30 5M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15B1TL30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B1TL30-M1 | E2E NEXT M30 15 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15B1DL30 2M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15B1DL30 5M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15B1DL30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B1DL30-M1 | E2E NEXT M30 15 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15C1L30 2M | E2E NEXT M30 15 mm NPN NO 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X15C1L30 5M | E2E NEXT M30 15 mm NPN NO 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X15C1L30-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C1L30-M1 | E2E NEXT M30 15 mm NPN NO M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X15B2L30 2M | E2E NEXT M30 15 mm PNP NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X15B2L30 5M | E2E NEXT M30 15 mm PNP NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X15B2L30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B2L30-M1 | E2E NEXT M30 15 mm PNP NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X15C2L30 2M | E2E NEXT M30 15 mm NPN NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X15C2L30 5M | E2E NEXT M30 15 mm NPN NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X15C2L30-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C2L30-M1 | E2E NEXT M30 15 mm NPN NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X15B3DL30 2M | E2E NEXT M30 15 mm PNP NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X15B3DL30 5M | E2E NEXT M30 15 mm PNP NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X15B3DL30-M1TJ 0.3M | E2E NEXT M30 15 mm PNP NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15B3DL30-M1 | E2E NEXT M30 15 mm PNP NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X15C3L30 2M | E2E NEXT M30 15 mm NPN NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X15C3L30 5M | E2E NEXT M30 15 mm NPN NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X15C3L30-M1TJ 0.3M | E2E NEXT M30 15 mm NPN NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X15C3L30-M1 | E2E NEXT M30 15 mm NPN NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 15 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M30 body, Unshielded. Sensing distance 30 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M30 body, Unshielded. Sensing distance 30 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X30MBB1T30 2M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBB1T30 5M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBB1T30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB1T30-M1 | E2E NEXT M30 30 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBB1D30 2M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBB1D30 5M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBB1D30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB1D30-M1 | E2E NEXT M30 30 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBC130 2M | E2E NEXT M30 30 mm NPN NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBC130 5M | E2E NEXT M30 30 mm NPN NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBC130-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC130-M1 | E2E NEXT M30 30 mm NPN NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBB230 2M | E2E NEXT M30 30 mm PNP NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X30MBB230 5M | E2E NEXT M30 30 mm PNP NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X30MBB230-M1TJ 0.3M | E2E NEXT M30 30 mm PNP NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB230-M1 | E2E NEXT M30 30 mm PNP NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X30MBC230 2M | E2E NEXT M30 30 mm NPN NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X30MBC230 5M | E2E NEXT M30 30 mm NPN NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X30MBC230-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC230-M1 | E2E NEXT M30 30 mm NPN NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X30MBB3D30 2M | E2E NEXT M30 30 mm PNP NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X30MBB3D30 5M | E2E NEXT M30 30 mm PNP NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X30MBB3D30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB3D30-M1 | E2E NEXT M30 30 mm PNP NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X30MBC330 2M | E2E NEXT M30 30 mm NPN NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X30MBC330 5M | E2E NEXT M30 30 mm NPN NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X30MBC330-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC330-M1 | E2E NEXT M30 30 mm NPN NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X30MBB1TL30 2M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBB1TL30 5M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBB1TL30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB1TL30-M1 | E2E NEXT M30 30 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBB1DL30 2M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBB1DL30 5M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBB1DL30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB1DL30-M1 | E2E NEXT M30 30 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBC1L30 2M | E2E NEXT M30 30 mm NPN NO 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X30MBC1L30 5M | E2E NEXT M30 30 mm NPN NO 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X30MBC1L30-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NO Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC1L30-M1 | E2E NEXT M30 30 mm NPN NO M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X30MBB2L30 2M | E2E NEXT M30 30 mm PNP NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X30MBB2L30 5M | E2E NEXT M30 30 mm PNP NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X30MBB2L30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB2L30-M1 | E2E NEXT M30 30 mm PNP NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X30MBC2L30 2M | E2E NEXT M30 30 mm NPN NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X30MBC2L30 5M | E2E NEXT M30 30 mm NPN NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X30MBC2L30-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NC Smartclick 0.3m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC2L30-M1 | E2E NEXT M30 30 mm NPN NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X30MBB3DL30 2M | E2E NEXT M30 30 mm PNP NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X30MBB3DL30 5M | E2E NEXT M30 30 mm PNP NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X30MBB3DL30-M1TJ 0.3M | E2E NEXT M30 30 mm PNP NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBB3DL30-M1 | E2E NEXT M30 30 mm PNP NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X30MBC3L30 2M | E2E NEXT M30 30 mm NPN NO+NC 2m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X30MBC3L30 5M | E2E NEXT M30 30 mm NPN NO+NC 5m | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X30MBC3L30-M1TJ 0.3M | E2E NEXT M30 30 mm NPN NO+NC Smartclick | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X30MBC3L30-M1 | E2E NEXT M30 30 mm NPN NO+NC M12 conn | OMRON | Size: M30 | Sensing Distance: 30 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M8 body, Shielded. Sensing distance 2 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M8 body, Shielded. Sensing distance 2 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X2B1T8 2M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1T8 5M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1T8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1T8-M1 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1T8-M3 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2B1T8-M5 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2B1D8 2M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1D8 5M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1D8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1D8-M1 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1D8-M3 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2B1D8-M5 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2C18 2M | E2E NEXT M8 2 mm NPN NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2C18 5M | E2E NEXT M8 2 mm NPN NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2C18-M1TJ 0.3M | E2E NEXT M8 2 mm NPN NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C18-M1 | E2E NEXT M8 2 mm NPN NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2C18-M3 | E2E NEXT M8 2 mm NPN NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2C18-M5 | E2E NEXT M8 2 mm NPN NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2B28 2M | E2E NEXT M8 2 mm PNP NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2B28 5M | E2E NEXT M8 2 mm PNP NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2B28-M1TJ 0.3M | E2E NEXT M8 2 mm PNP NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B28-M1 | E2E NEXT M8 2 mm PNP NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2B28-M3 | E2E NEXT M8 2 mm PNP NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X2B28-M5 | E2E NEXT M8 2 mm PNP NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X2C28 2M | E2E NEXT M8 2 mm NPN NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2C28 5M | E2E NEXT M8 2 mm NPN NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2C28-M1TJ 0.3M | E2E NEXT M8 2 mm NPN NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C28-M1 | E2E NEXT M8 2 mm NPN NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2C28-M3 | E2E NEXT M8 2 mm NPN NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X2C28-M5 | E2E NEXT M8 2 mm NPN NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X2B1TL8 2M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1TL8 5M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1TL8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1TL8-M1 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1TL8-M3 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2B1TL8-M5 | E2E NEXT M8 2 mm PNP IO-Link COM3 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2B1DL8 2M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1DL8 5M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1DL8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1DL8-M1 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1DL8-M3 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2B1DL8-M5 | E2E NEXT M8 2 mm PNP IO-Link COM2 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2C1L8 2M | E2E NEXT M8 2 mm NPN NO 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2C1L8 5M | E2E NEXT M8 2 mm NPN NO 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2C1L8-M1TJ 0.3M | E2E NEXT M8 2 mm NPN NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C1L8-M1 | E2E NEXT M8 2 mm NPN NO M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2C1L8-M3 | E2E NEXT M8 2 mm NPN NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X2C1L8-M5 | E2E NEXT M8 2 mm NPN NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X2B2L8 2M | E2E NEXT M8 2 mm PNP NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2B2L8 5M | E2E NEXT M8 2 mm PNP NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2B2L8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B2L8-M1 | E2E NEXT M8 2 mm PNP NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2B2L8-M3 | E2E NEXT M8 2 mm PNP NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X2B2L8-M5 | E2E NEXT M8 2 mm PNP NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X2C2L8 2M | E2E NEXT M8 2 mm NPN NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2C2L8 5M | E2E NEXT M8 2 mm NPN NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2C2L8-M1TJ 0.3M | E2E NEXT M8 2 mm NPN NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C2L8-M1 | E2E NEXT M8 2 mm NPN NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2C2L8-M3 | E2E NEXT M8 2 mm NPN NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X2C2L8-M5 | E2E NEXT M8 2 mm NPN NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X2B3DL8 2M | E2E NEXT M8 2 mm PNP NO+NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2B3DL8 5M | E2E NEXT M8 2 mm PNP NO+NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2B3DL8-M1TJ 0.3M | E2E NEXT M8 2 mm PNP NO+NC Smartclick | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B3DL8-M1 | E2E NEXT M8 2 mm PNP NO+NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X2C3L8 2M | E2E NEXT M8 2 mm NPN NO+NC 2m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2C3L8 5M | E2E NEXT M8 2 mm NPN NO+NC 5m | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2C3L8-M1TJ 0.3M | E2E NEXT M8 2 mm NPN NO+NC Smartclick | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C3L8-M1 | E2E NEXT M8 2 mm NPN NO+NC M12 conn | OMRON | Size: M8 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M8 body, Unshielded. Sensing distance 4 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Double distance cylindrical proximity sensor. M8 body, Unshielded. Sensing distance 4 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X4MBB1T8 2M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBB1T8 5M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBB1T8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB1T8-M1 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBB1T8-M3 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBB1T8-M5 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBB1D8 2M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBB1D8 5M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBB1D8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB1D8-M1 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBB1D8-M3 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBB1D8-M5 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBC18 2M | E2E NEXT M8 4 mm NPN NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBC18 5M | E2E NEXT M8 4 mm NPN NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBC18-M1TJ 0.3M | E2E NEXT M8 4 mm NPN NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBC18-M1 | E2E NEXT M8 4 mm NPN NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBC18-M3 | E2E NEXT M8 4 mm NPN NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBC18-M5 | E2E NEXT M8 4 mm NPN NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBB28 2M | E2E NEXT M8 4 mm PNP NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4MBB28 5M | E2E NEXT M8 4 mm PNP NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4MBB28-M1TJ 0.3M | E2E NEXT M8 4 mm PNP NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB28-M1 | E2E NEXT M8 4 mm PNP NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4MBB28-M3 | E2E NEXT M8 4 mm PNP NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X4MBB28-M5 | E2E NEXT M8 4 mm PNP NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X4MBC28 2M | E2E NEXT M8 4 mm NPN NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4MBC28 5M | E2E NEXT M8 4 mm NPN NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4MBC28-M1TJ 0.3M | E2E NEXT M8 4 mm NPN NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBC28-M1 | E2E NEXT M8 4 mm NPN NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4MBC28-M3 | E2E NEXT M8 4 mm NPN NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X4MBC28-M5 | E2E NEXT M8 4 mm NPN NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X4MBB1TL8 2M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBB1TL8 5M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBB1TL8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB1TL8-M1 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBB1TL8-M3 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBB1TL8-M5 | E2E NEXT M8 4 mm PNP IO-Link COM3 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBB1DL8 2M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBB1DL8 5M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBB1DL8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB1DL8-M1 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBB1DL8-M3 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBB1DL8-M5 | E2E NEXT M8 4 mm PNP IO-Link COM2 NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBC1L8 2M | E2E NEXT M8 4 mm NPN NO 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X4MBC1L8 5M | E2E NEXT M8 4 mm NPN NO 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X4MBC1L8-M1TJ 0.3M | E2E NEXT M8 4 mm NPN NO Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBC1L8-M1 | E2E NEXT M8 4 mm NPN NO M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X4MBC1L8-M3 | E2E NEXT M8 4 mm NPN NO M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 4-pin | |
| E2E-X4MBC1L8-M5 | E2E NEXT M8 4 mm NPN NO M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M8 Connector 3-pin | |
| E2E-X4MBB2L8 2M | E2E NEXT M8 4 mm PNP NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4MBB2L8 5M | E2E NEXT M8 4 mm PNP NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4MBB2L8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB2L8-M1 | E2E NEXT M8 4 mm PNP NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4MBB2L8-M3 | E2E NEXT M8 4 mm PNP NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X4MBB2L8-M5 | E2E NEXT M8 4 mm PNP NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X4MBC2L8 2M | E2E NEXT M8 4 mm NPN NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X4MBC2L8 5M | E2E NEXT M8 4 mm NPN NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X4MBC2L8-M1TJ 0.3M | E2E NEXT M8 4 mm NPN NC Smartclick 0.3m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBC2L8-M1 | E2E NEXT M8 4 mm NPN NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X4MBC2L8-M3 | E2E NEXT M8 4 mm NPN NC M8 4pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 4-pin | |
| E2E-X4MBC2L8-M5 | E2E NEXT M8 4 mm NPN NC M8 3pin conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M8 Connector 3-pin | |
| E2E-X4MBB3DL8 2M | E2E NEXT M8 4 mm PNP NO+NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4MBB3DL8 5M | E2E NEXT M8 4 mm PNP NO+NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4MBB3DL8-M1TJ 0.3M | E2E NEXT M8 4 mm PNP NO+NC Smartclick | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBB3DL8-M1 | E2E NEXT M8 4 mm PNP NO+NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X4MBC3L8 2M | E2E NEXT M8 4 mm NPN NO+NC 2m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X4MBC3L8 5M | E2E NEXT M8 4 mm NPN NO+NC 5m | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X4MBC3L8-M1TJ 0.3M | E2E NEXT M8 4 mm NPN NO+NC Smartclick | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X4MBC3L8-M1 | E2E NEXT M8 4 mm NPN NO+NC M12 conn | OMRON | Size: M8 | Sensing Distance: 4 mm | Shield: Unshielded | Grade: BASIC Double distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |
OMRON E2E NEXT Series BASIC Single distance cylindrical proximity sensor. M12 body, Shielded. Sensing distance 2 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
OMRON E2E NEXT Series BASIC Single distance cylindrical proximity sensor. M12 body, Shielded. Sensing distance 2 mm (standard body). DC 3-wire. PNP IO-Link COM3/COM2 and NPN. NO/NC/NO+NC. Pre-wired 2m/5m, M12 Smartclick 0.3m, M12/M8 connector. IO-Link standard feature. Operation mode changeable via IO-Link.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E2E-X2B1T12 2M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1T12 5M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1T12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1T12-M1 | E2E NEXT M12 2 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1D12 2M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1D12 5M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1D12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1D12-M1 | E2E NEXT M12 2 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2C112 2M | E2E NEXT M12 2 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2C112 5M | E2E NEXT M12 2 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2C112-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C112-M1 | E2E NEXT M12 2 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B212 2M | E2E NEXT M12 2 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2B212 5M | E2E NEXT M12 2 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2B212-M1TJ 0.3M | E2E NEXT M12 2 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B212-M1 | E2E NEXT M12 2 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2C212 2M | E2E NEXT M12 2 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2C212 5M | E2E NEXT M12 2 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2C212-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C212-M1 | E2E NEXT M12 2 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2B3D12 2M | E2E NEXT M12 2 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2B3D12 5M | E2E NEXT M12 2 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2B3D12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B3D12-M1 | E2E NEXT M12 2 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X2C312 2M | E2E NEXT M12 2 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2C312 5M | E2E NEXT M12 2 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2C312-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C312-M1 | E2E NEXT M12 2 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Standard | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X2B1TL12 2M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1TL12 5M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1TL12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP IO-Link COM3 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1TL12-M1 | E2E NEXT M12 2 mm PNP IO-Link COM3 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM3 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B1DL12 2M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2B1DL12 5M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2B1DL12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP IO-Link COM2 NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B1DL12-M1 | E2E NEXT M12 2 mm PNP IO-Link COM2 NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP IO-Link COM2 | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2C1L12 2M | E2E NEXT M12 2 mm NPN NO 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 2 m | |
| E2E-X2C1L12 5M | E2E NEXT M12 2 mm NPN NO 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: Pre-wired 5 m | |
| E2E-X2C1L12-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NO Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C1L12-M1 | E2E NEXT M12 2 mm NPN NO M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO | Connection: M12 Connector | |
| E2E-X2B2L12 2M | E2E NEXT M12 2 mm PNP NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2B2L12 5M | E2E NEXT M12 2 mm PNP NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2B2L12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B2L12-M1 | E2E NEXT M12 2 mm PNP NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2C2L12 2M | E2E NEXT M12 2 mm NPN NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 2 m | |
| E2E-X2C2L12 5M | E2E NEXT M12 2 mm NPN NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: Pre-wired 5 m | |
| E2E-X2C2L12-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NC Smartclick 0.3m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C2L12-M1 | E2E NEXT M12 2 mm NPN NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NC | Connection: M12 Connector | |
| E2E-X2B3DL12 2M | E2E NEXT M12 2 mm PNP NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2B3DL12 5M | E2E NEXT M12 2 mm PNP NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2B3DL12-M1TJ 0.3M | E2E NEXT M12 2 mm PNP NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2B3DL12-M1 | E2E NEXT M12 2 mm PNP NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: PNP | Operation Mode: NO+NC | Connection: M12 Connector | |
| E2E-X2C3L12 2M | E2E NEXT M12 2 mm NPN NO+NC 2m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 2 m | |
| E2E-X2C3L12 5M | E2E NEXT M12 2 mm NPN NO+NC 5m | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: Pre-wired 5 m | |
| E2E-X2C3L12-M1TJ 0.3M | E2E NEXT M12 2 mm NPN NO+NC Smartclick | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Pre-wired Smartclick Connector 0.3 m | |
| E2E-X2C3L12-M1 | E2E NEXT M12 2 mm NPN NO+NC M12 conn | OMRON | Size: M12 | Sensing Distance: 2 mm | Shield: Shielded | Grade: BASIC Single distance | Body Length: Long | Note: IO-Link not supported for NC-type PNP or NPN outputs; NO mode changeable to NC via IO-Link | Output: NPN | Operation Mode: NO+NC | Connection: M12 Connector |