[MITSUBISHI ELECTRIC] β TH-N120 / TH-N120TA Series Thermal Overload Relay (42-125A, N120 Frame)
βΆMitsubishi Electric TH-N120 / TH-N120TA Series thermal overload relay for MS-T/N series magnetic contactors and starters, n120 frame, heater designations 42-125A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-N120 / TH-N120TA Series thermal overload relay for MS-T/N series magnetic contactors and starters, n120 frame, heater designations 42-125A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-N120 42A | TH-N120 thermal relay, 42A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120 54A | TH-N120 thermal relay, 54A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 54A (adjustable 43-65A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120 67A | TH-N120 thermal relay, 67A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 67A (adjustable 54-80A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120 82A | TH-N120 thermal relay, 82A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120KP 42A | TH-N120KP thermal relay, 42A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120KP 54A | TH-N120KP thermal relay, 54A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 54A (adjustable 43-65A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120KP 67A | TH-N120KP thermal relay, 67A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 67A (adjustable 54-80A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120KP 82A | TH-N120KP thermal relay, 82A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TA 105A | TH-N120TA thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TA 125A | TH-N120TA thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAHZ 105A | TH-N120TAHZ thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAHZ 125A | TH-N120TAHZ thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAKP 105A | TH-N120TAKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAKP 125A | TH-N120TAKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAHZKP 105A | TH-N120TAHZKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N120TAHZKP 125A | TH-N120TAHZKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N120 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-N220RH / TH-N220HZ thermal overload relay for MS-T/N series magnetic contactors and starters, n220 frame, heater designations 82-180A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-N220RH / TH-N220HZ thermal overload relay for MS-T/N series magnetic contactors and starters, n220 frame, heater designations 82-180A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-N220RH 82A | TH-N220RH thermal relay, 82A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RH 105A | TH-N220RH thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RH 125A | TH-N220RH thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RH 150A | TH-N220RH thermal relay, 150A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 150A (adjustable 120-180A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RH 180A | TH-N220RH thermal relay, 180A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 180A (adjustable 140-220A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZ 82A | TH-N220HZ thermal relay, 82A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 82A (adjustable 65-100A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZ 105A | TH-N220HZ thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZ 125A | TH-N220HZ thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZ 150A | TH-N220HZ thermal relay, 150A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 150A (adjustable 120-180A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZ 180A | TH-N220HZ thermal relay, 180A heater, 2-element | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 180A (adjustable 140-220A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RHKP 82A | TH-N220RHKP thermal relay, 82A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RHKP 105A | TH-N220RHKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RHKP 125A | TH-N220RHKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RHKP 150A | TH-N220RHKP thermal relay, 150A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 150A (adjustable 120-180A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220RHKP 180A | TH-N220RHKP thermal relay, 180A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 180A (adjustable 140-220A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZKP 82A | TH-N220HZKP thermal relay, 82A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 82A (adjustable 65-100A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZKP 105A | TH-N220HZKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZKP 125A | TH-N220HZKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZKP 150A | TH-N220HZKP thermal relay, 150A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 150A (adjustable 120-180A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N220HZKP 180A | TH-N220HZKP thermal relay, 180A heater, 3-element 2E | Mitsubishi Electric | Frame: N220 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 180A (adjustable 140-220A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-N400RH / TH-N400HZ thermal overload relay for MS-T/N series magnetic contactors and starters, n400 frame, heater designations 105-330A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-N400RH / TH-N400HZ thermal overload relay for MS-T/N series magnetic contactors and starters, n400 frame, heater designations 105-330A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-N400RH 105A | TH-N400RH thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RH 125A | TH-N400RH thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RH 150A | TH-N400RH thermal relay, 150A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 150A (adjustable 120-180A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RH 180A | TH-N400RH thermal relay, 180A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 180A (adjustable 140-220A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RH 250A | TH-N400RH thermal relay, 250A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 250A (adjustable 200-300A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RH 330A | TH-N400RH thermal relay, 330A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 330A (adjustable 260-400A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 105A | TH-N400HZ thermal relay, 105A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 125A | TH-N400HZ thermal relay, 125A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 150A | TH-N400HZ thermal relay, 150A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 150A (adjustable 120-180A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 180A | TH-N400HZ thermal relay, 180A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 180A (adjustable 140-220A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 250A | TH-N400HZ thermal relay, 250A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 250A (adjustable 200-300A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZ 330A | TH-N400HZ thermal relay, 330A heater, 2-element | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 330A (adjustable 260-400A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 105A | TH-N400RHKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 125A | TH-N400RHKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 150A | TH-N400RHKP thermal relay, 150A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 150A (adjustable 120-180A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 180A | TH-N400RHKP thermal relay, 180A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 180A (adjustable 140-220A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 250A | TH-N400RHKP thermal relay, 250A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 250A (adjustable 200-300A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400RHKP 330A | TH-N400RHKP thermal relay, 330A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 330A (adjustable 260-400A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 105A | TH-N400HZKP thermal relay, 105A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 105A (adjustable 85-125A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 125A | TH-N400HZKP thermal relay, 125A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 125A (adjustable 100-150A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 150A | TH-N400HZKP thermal relay, 150A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 150A (adjustable 120-180A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 180A | TH-N400HZKP thermal relay, 180A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 180A (adjustable 140-220A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 250A | TH-N400HZKP thermal relay, 250A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 250A (adjustable 200-300A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N400HZKP 330A | TH-N400HZKP thermal relay, 330A heater, 3-element 2E | Mitsubishi Electric | Frame: N400 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 330A (adjustable 260-400A) Β· Mounting: Standalone mounting Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-N600 / TH-N600KP thermal overload relay for MS-T/N series magnetic contactors and starters, n600 frame, heater designations 250-660A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Used in combination with separately sold Mitsubishi CW-type current transformers.
Mitsubishi Electric TH-N600 / TH-N600KP thermal overload relay for MS-T/N series magnetic contactors and starters, n600 frame, heater designations 250-660A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Used in combination with separately sold Mitsubishi CW-type current transformers.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-N600 250A | TH-N600 thermal relay, 250A heater, 2-element | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 250A (adjustable 200-300A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 400/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600 330A | TH-N600 thermal relay, 330A heater, 2-element | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 330A (adjustable 260-400A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 500/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600 500A | TH-N600 thermal relay, 500A heater, 2-element | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 500A (adjustable 400-600A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 750/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600 660A | TH-N600 thermal relay, 660A heater, 2-element | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 660A (adjustable 520-800A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 1000/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600KP 250A | TH-N600KP thermal relay, 250A heater, 3-element 2E | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 250A (adjustable 200-300A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 400/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600KP 330A | TH-N600KP thermal relay, 330A heater, 3-element 2E | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 330A (adjustable 260-400A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 500/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600KP 500A | TH-N600KP thermal relay, 500A heater, 3-element 2E | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 500A (adjustable 400-600A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 750/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-N600KP 660A | TH-N600KP thermal relay, 660A heater, 3-element 2E | Mitsubishi Electric | Frame: N600 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 660A (adjustable 520-800A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Current Transformer: CW type, ratio 1000/5A (sold separately) Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-T100 / TH-T100KP thermal overload relay for MS-T/N series magnetic contactors and starters, t100 frame, heater designations 67-82A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-T100 / TH-T100KP thermal overload relay for MS-T/N series magnetic contactors and starters, t100 frame, heater designations 67-82A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-T100 67A | TH-T100 thermal relay, 67A heater, 2-element | Mitsubishi Electric | Frame: T100 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 67A (adjustable 54-80A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T100 82A | TH-T100 thermal relay, 82A heater, 2-element | Mitsubishi Electric | Frame: T100 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T100KP 67A | TH-T100KP thermal relay, 67A heater, 3-element 2E | Mitsubishi Electric | Frame: T100 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 67A (adjustable 54-80A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T100KP 82A | TH-T100KP thermal relay, 82A heater, 3-element 2E | Mitsubishi Electric | Frame: T100 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 82A (adjustable 65-100A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-T18 / TH-T18KP thermal overload relay for MS-T/N series magnetic contactors and starters, t18 frame, heater designations 0.12-15A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-T18 / TH-T18KP thermal overload relay for MS-T/N series magnetic contactors and starters, t18 frame, heater designations 0.12-15A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-T18 0.12A | TH-T18 thermal relay, 0.12A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.12A (adjustable 0.1-0.16A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.17A | TH-T18 thermal relay, 0.17A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.17A (adjustable 0.14-0.22A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.24A | TH-T18 thermal relay, 0.24A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.24A (adjustable 0.2-0.32A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.35A | TH-T18 thermal relay, 0.35A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.35A (adjustable 0.28-0.42A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.5A | TH-T18 thermal relay, 0.5A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.5A (adjustable 0.4-0.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.7A | TH-T18 thermal relay, 0.7A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.7A (adjustable 0.55-0.85A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 0.9A | TH-T18 thermal relay, 0.9A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.9A (adjustable 0.7-1.1A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 1.3A | TH-T18 thermal relay, 1.3A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 1.3A (adjustable 1-1.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 1.7A | TH-T18 thermal relay, 1.7A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 1.7A (adjustable 1.4-2A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 2.1A | TH-T18 thermal relay, 2.1A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 2.1A (adjustable 1.7-2.5A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 2.5A | TH-T18 thermal relay, 2.5A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 2.5A (adjustable 2-3A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 3.6A | TH-T18 thermal relay, 3.6A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 3.6A (adjustable 2.8-4.4A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 5A | TH-T18 thermal relay, 5A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 5A (adjustable 4-6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 6.6A | TH-T18 thermal relay, 6.6A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 6.6A (adjustable 5.2-8A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 9A | TH-T18 thermal relay, 9A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 9A (adjustable 7-11A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 11A | TH-T18 thermal relay, 11A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 11A (adjustable 9-13A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18 15A | TH-T18 thermal relay, 15A heater, 2-element | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.12A | TH-T18KP thermal relay, 0.12A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.12A (adjustable 0.1-0.16A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.17A | TH-T18KP thermal relay, 0.17A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.17A (adjustable 0.14-0.22A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.24A | TH-T18KP thermal relay, 0.24A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.24A (adjustable 0.2-0.32A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.35A | TH-T18KP thermal relay, 0.35A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.35A (adjustable 0.28-0.42A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.5A | TH-T18KP thermal relay, 0.5A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.5A (adjustable 0.4-0.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.7A | TH-T18KP thermal relay, 0.7A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.7A (adjustable 0.55-0.85A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 0.9A | TH-T18KP thermal relay, 0.9A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.9A (adjustable 0.7-1.1A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 1.3A | TH-T18KP thermal relay, 1.3A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 1.3A (adjustable 1-1.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 1.7A | TH-T18KP thermal relay, 1.7A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 1.7A (adjustable 1.4-2A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 2.1A | TH-T18KP thermal relay, 2.1A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 2.1A (adjustable 1.7-2.5A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 2.5A | TH-T18KP thermal relay, 2.5A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 2.5A (adjustable 2-3A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 3.6A | TH-T18KP thermal relay, 3.6A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 3.6A (adjustable 2.8-4.4A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 5A | TH-T18KP thermal relay, 5A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 5A (adjustable 4-6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 6.6A | TH-T18KP thermal relay, 6.6A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 6.6A (adjustable 5.2-8A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 9A | TH-T18KP thermal relay, 9A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 9A (adjustable 7-11A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 11A | TH-T18KP thermal relay, 11A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 11A (adjustable 9-13A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T18KP 15A | TH-T18KP thermal relay, 15A heater, 3-element 2E | Mitsubishi Electric | Frame: T18 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-T25 / TH-T25KP thermal overload relay for MS-T/N series magnetic contactors and starters, t25 frame, heater designations 0.24-22A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-T25 / TH-T25KP thermal overload relay for MS-T/N series magnetic contactors and starters, t25 frame, heater designations 0.24-22A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-T25 0.24A | TH-T25 thermal relay, 0.24A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.24A (adjustable 0.2-0.32A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 0.35A | TH-T25 thermal relay, 0.35A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.35A (adjustable 0.28-0.42A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 0.5A | TH-T25 thermal relay, 0.5A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.5A (adjustable 0.4-0.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 0.7A | TH-T25 thermal relay, 0.7A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.7A (adjustable 0.55-0.85A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 0.9A | TH-T25 thermal relay, 0.9A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 0.9A (adjustable 0.7-1.1A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 1.3A | TH-T25 thermal relay, 1.3A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 1.3A (adjustable 1-1.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 1.7A | TH-T25 thermal relay, 1.7A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 1.7A (adjustable 1.4-2A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 2.1A | TH-T25 thermal relay, 2.1A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 2.1A (adjustable 1.7-2.5A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 2.5A | TH-T25 thermal relay, 2.5A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 2.5A (adjustable 2-3A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 3.6A | TH-T25 thermal relay, 3.6A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 3.6A (adjustable 2.8-4.4A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 5A | TH-T25 thermal relay, 5A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 5A (adjustable 4-6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 6.6A | TH-T25 thermal relay, 6.6A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 6.6A (adjustable 5.2-8A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 9A | TH-T25 thermal relay, 9A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 9A (adjustable 7-11A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 11A | TH-T25 thermal relay, 11A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 11A (adjustable 9-13A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 15A | TH-T25 thermal relay, 15A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25 22A | TH-T25 thermal relay, 22A heater, 2-element | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 22A (adjustable 18-26A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 0.24A | TH-T25KP thermal relay, 0.24A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.24A (adjustable 0.2-0.32A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 0.35A | TH-T25KP thermal relay, 0.35A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.35A (adjustable 0.28-0.42A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 0.5A | TH-T25KP thermal relay, 0.5A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.5A (adjustable 0.4-0.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 0.7A | TH-T25KP thermal relay, 0.7A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.7A (adjustable 0.55-0.85A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 0.9A | TH-T25KP thermal relay, 0.9A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 0.9A (adjustable 0.7-1.1A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 1.3A | TH-T25KP thermal relay, 1.3A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 1.3A (adjustable 1-1.6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 1.7A | TH-T25KP thermal relay, 1.7A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 1.7A (adjustable 1.4-2A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 2.1A | TH-T25KP thermal relay, 2.1A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 2.1A (adjustable 1.7-2.5A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 2.5A | TH-T25KP thermal relay, 2.5A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 2.5A (adjustable 2-3A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 3.6A | TH-T25KP thermal relay, 3.6A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 3.6A (adjustable 2.8-4.4A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 5A | TH-T25KP thermal relay, 5A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 5A (adjustable 4-6A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 6.6A | TH-T25KP thermal relay, 6.6A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 6.6A (adjustable 5.2-8A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 9A | TH-T25KP thermal relay, 9A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 9A (adjustable 7-11A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 11A | TH-T25KP thermal relay, 11A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 11A (adjustable 9-13A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 15A | TH-T25KP thermal relay, 15A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T25KP 22A | TH-T25KP thermal relay, 22A heater, 3-element 2E | Mitsubishi Electric | Frame: T25 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 22A (adjustable 18-26A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-T50 / TH-T50KP thermal overload relay for MS-T/N series magnetic contactors and starters, t50 frame, heater designations 29-42A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-T50 / TH-T50KP thermal overload relay for MS-T/N series magnetic contactors and starters, t50 frame, heater designations 29-42A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-T50 29A | TH-T50 thermal relay, 29A heater, 2-element | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 29A (adjustable 24-34A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T50 35A | TH-T50 thermal relay, 35A heater, 2-element | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 35A (adjustable 30-40A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T50 42A | TH-T50 thermal relay, 42A heater, 2-element | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T50KP 29A | TH-T50KP thermal relay, 29A heater, 3-element 2E | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 29A (adjustable 24-34A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T50KP 35A | TH-T50KP thermal relay, 35A heater, 3-element 2E | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 35A (adjustable 30-40A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T50KP 42A | TH-T50KP thermal relay, 42A heater, 3-element 2E | Mitsubishi Electric | Frame: T50 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric TH-T65 / TH-T65KP thermal overload relay for MS-T/N series magnetic contactors and starters, t65 frame, heater designations 15-54A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric TH-T65 / TH-T65KP thermal overload relay for MS-T/N series magnetic contactors and starters, t65 frame, heater designations 15-54A. 2-element type for overload protection, KP 3-element (2E) type for combined overload and open-phase protection. Manual reset standard (auto-reset AR type available to order); auxiliary contact 1a1b. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TH-T65 15A | TH-T65 thermal relay, 15A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65 22A | TH-T65 thermal relay, 22A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 22A (adjustable 18-26A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65 29A | TH-T65 thermal relay, 29A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 29A (adjustable 24-34A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65 35A | TH-T65 thermal relay, 35A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 35A (adjustable 30-40A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65 42A | TH-T65 thermal relay, 42A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65 54A | TH-T65 thermal relay, 54A heater, 2-element | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 2-element Β· Protection: Overload Β· Heater: 54A (adjustable 43-65A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 15A | TH-T65KP thermal relay, 15A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 15A (adjustable 12-18A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 22A | TH-T65KP thermal relay, 22A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 22A (adjustable 18-26A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 29A | TH-T65KP thermal relay, 29A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 29A (adjustable 24-34A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 35A | TH-T65KP thermal relay, 35A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 35A (adjustable 30-40A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 42A | TH-T65KP thermal relay, 42A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 42A (adjustable 34-50A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| TH-T65KP 54A | TH-T65KP thermal relay, 54A heater, 3-element 2E | Mitsubishi Electric | Frame: T65 Β· Type: Thermal Overload Relay Β· Elements: 3-element (2E) Β· Protection: Overload + Open-phase Β· Heater: 54A (adjustable 43-65A) Β· Mounting: For magnetic starter combination Β· Reset: Manual (standard) Β· Aux Contact: 1a1b Β· Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |