Electrical
LS ELECTRIC Susol Smart MCCB TS800Ni family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 65kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS800Ni family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 65kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800Ni-ETSi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-ATU-100A-3P | Susol Beyond X UTV250-E-ATU-IEC — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-100A-4P | Susol Beyond X UTV250-E-ATU-IEC — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-3P | Susol Beyond X UTV250-E-ATU-IEC — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-4P | Susol Beyond X UTV250-E-ATU-IEC — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-3P | Susol Beyond X UTV250-E-ATU-IEC — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-4P | Susol Beyond X UTV250-E-ATU-IEC — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-3P | Susol Beyond X UTV250-E-ATU-IEC — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-4P | Susol Beyond X UTV250-E-ATU-IEC — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-ATU-100A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-100A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FMU-60A-3P | Susol Beyond X UTV250-E-FMU-IEC — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-60A-4P | Susol Beyond X UTV250-E-FMU-IEC — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-3P | Susol Beyond X UTV250-E-FMU-IEC — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-4P | Susol Beyond X UTV250-E-FMU-IEC — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-3P | Susol Beyond X UTV250-E-FMU-IEC — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-4P | Susol Beyond X UTV250-E-FMU-IEC — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-3P | Susol Beyond X UTV250-E-FMU-IEC — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-4P | Susol Beyond X UTV250-E-FMU-IEC — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-3P | Susol Beyond X UTV250-E-FMU-IEC — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-4P | Susol Beyond X UTV250-E-FMU-IEC — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-3P | Susol Beyond X UTV250-E-FMU-IEC — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-4P | Susol Beyond X UTV250-E-FMU-IEC — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FMU-60A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-60A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FTU-60A-3P | Susol Beyond X UTV250-E-FTU-IEC — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-60A-4P | Susol Beyond X UTV250-E-FTU-IEC — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-3P | Susol Beyond X UTV250-E-FTU-IEC — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-4P | Susol Beyond X UTV250-E-FTU-IEC — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-3P | Susol Beyond X UTV250-E-FTU-IEC — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-4P | Susol Beyond X UTV250-E-FTU-IEC — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-3P | Susol Beyond X UTV250-E-FTU-IEC — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-4P | Susol Beyond X UTV250-E-FTU-IEC — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-3P | Susol Beyond X UTV250-E-FTU-IEC — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-4P | Susol Beyond X UTV250-E-FTU-IEC — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-3P | Susol Beyond X UTV250-E-FTU-IEC — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-4P | Susol Beyond X UTV250-E-FTU-IEC — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FTU-60A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-60A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-ATU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 100~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-ATU-100A-3P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-100A-4P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-3P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-4P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-3P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-4P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-3P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-4P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-ATU-100A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-100A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-FMU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FMU 60~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FMU-60A-3P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-60A-4P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-3P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-4P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-3P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-4P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-3P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-4P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-3P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-4P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-3P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-4P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FMU-60A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-60A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-FTU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FTU 60~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FTU-60A-3P | Susol Beyond X UTV250-N-FTU-IEC — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-60A-4P | Susol Beyond X UTV250-N-FTU-IEC — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-3P | Susol Beyond X UTV250-N-FTU-IEC — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-4P | Susol Beyond X UTV250-N-FTU-IEC — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-3P | Susol Beyond X UTV250-N-FTU-IEC — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-4P | Susol Beyond X UTV250-N-FTU-IEC — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-3P | Susol Beyond X UTV250-N-FTU-IEC — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-4P | Susol Beyond X UTV250-N-FTU-IEC — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-3P | Susol Beyond X UTV250-N-FTU-IEC — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-4P | Susol Beyond X UTV250-N-FTU-IEC — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-3P | Susol Beyond X UTV250-N-FTU-IEC — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-4P | Susol Beyond X UTV250-N-FTU-IEC — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FTU-60A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-60A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-3P-UL | Susol Beyond X UTV250-N-FTU-UL — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-4P-UL | Susol Beyond X UTV250-N-FTU-UL — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-ATU-320A-3P | Susol Beyond X UTV400-E-ATU-IEC — 320A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-320A-4P | Susol Beyond X UTV400-E-ATU-IEC — 320A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-400A-3P | Susol Beyond X UTV400-E-ATU-IEC — 400A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-ATU-400A-4P | Susol Beyond X UTV400-E-ATU-IEC — 400A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-FMU-320A-3P | Susol Beyond X UTV400-E-FMU-IEC — 320A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-320A-4P | Susol Beyond X UTV400-E-FMU-IEC — 320A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-400A-3P | Susol Beyond X UTV400-E-FMU-IEC — 400A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FMU-400A-4P | Susol Beyond X UTV400-E-FMU-IEC — 400A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-E-FTU-320A-3P | Susol Beyond X UTV400-E-FTU-IEC — 320A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-320A-4P | Susol Beyond X UTV400-E-FTU-IEC — 320A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-400A-3P | Susol Beyond X UTV400-E-FTU-IEC — 400A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-E-FTU-400A-4P | Susol Beyond X UTV400-E-FTU-IEC — 400A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-ATU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-ATU-320A-3P | Susol Beyond X UTV400-N-ATU-IEC — 320A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-320A-4P | Susol Beyond X UTV400-N-ATU-IEC — 320A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-400A-3P | Susol Beyond X UTV400-N-ATU-IEC — 400A ATU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-ATU-400A-4P | Susol Beyond X UTV400-N-ATU-IEC — 400A ATU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-FMU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FMU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-FMU-320A-3P | Susol Beyond X UTV400-N-FMU-IEC — 320A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-320A-4P | Susol Beyond X UTV400-N-FMU-IEC — 320A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-400A-3P | Susol Beyond X UTV400-N-FMU-IEC — 400A FMU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FMU-400A-4P | Susol Beyond X UTV400-N-FMU-IEC — 400A FMU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV400-N-FTU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FTU 320~400A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV400-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV400-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 400AF | Rated voltage: 800/1000 Vac | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 320A, 400A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 4 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV400-N-FTU-320A-3P | Susol Beyond X UTV400-N-FTU-IEC — 320A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-320A-4P | Susol Beyond X UTV400-N-FTU-IEC — 320A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 320A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-400A-3P | Susol Beyond X UTV400-N-FTU-IEC — 400A FTU, 3-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 140×290×110 mm | Weight: 7.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV400-N-FTU-400A-4P | Susol Beyond X UTV400-N-FTU-IEC — 400A FTU, 4-pole | LS ELECTRIC | Frame: 400AF | Rated voltage: 800/1000 Vac | Rated current (In): 400A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 186.5×290×110 mm | Weight: 8.7 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
Professional auto wire stripper made of highest quality tool steel with precision blade for clean stripping and wire length adjustment attachment
Professional auto wire stripper made of highest quality tool steel with precision blade for clean stripping and wire length adjustment attachment
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| 219-0149 | Professional auto wire stripper for solid wire small gauge | MARVEL | Model: MES-A, Application Range: 0.5/1.2/1.6/2.0mm, Application: Solid Wire | |
| 219-0158 | Professional auto wire stripper for solid wire medium gauge | MARVEL | Model: MES-B, Application Range: 1.0/1.6/2.0/2.6/3.2mm, Application: Solid Wire | |
| 219-0167 | Professional auto wire stripper for IV cable | MARVEL | Model: MES-C, Application Range: 1.25/2.0/3.5/5.5/8.0mm, Application: IV Cable | |
| 219-1218 | Professional auto wire stripper for twisted wire DIN standard | MARVEL | Model: MWSDIN, Application Range: DIN 0.5/0.75/1.0/1.5/2.5/4.0/6.0mm, Application: Twisted Wire, Standard: DIN |