Magnetic Starters
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T12 Magnetic Starter (13A AC-3, T12 Frame, TH-T18 Thermal)
▶Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSO-T12: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSO-T12: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T12 0.12A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.12A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.17A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.24A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.35A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.5A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.7A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC24V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC48V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC100V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC200V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC300V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC400V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 0.9A AC500V | MSO-T12 non-reversing starter, T12 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC24V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC48V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC100V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC200V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC300V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC400V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.3A AC500V | MSO-T12 non-reversing starter, T12 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC24V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC48V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC100V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC200V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC300V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC400V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 1.7A AC500V | MSO-T12 non-reversing starter, T12 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC24V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC48V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC100V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC200V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC300V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC400V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.1A AC500V | MSO-T12 non-reversing starter, T12 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC24V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC48V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC100V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC200V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC300V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC400V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 2.5A AC500V | MSO-T12 non-reversing starter, T12 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC24V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC48V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC100V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC200V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC300V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC400V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 3.6A AC500V | MSO-T12 non-reversing starter, T12 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC24V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC48V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC100V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC200V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC300V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC400V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 5A AC500V | MSO-T12 non-reversing starter, T12 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC24V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC48V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC100V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC200V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC300V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC400V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 6.6A AC500V | MSO-T12 non-reversing starter, T12 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC24V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC48V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC100V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC200V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC300V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC400V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 9A AC500V | MSO-T12 non-reversing starter, T12 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC24V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC48V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC100V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC200V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC300V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC400V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12 11A AC500V | MSO-T12 non-reversing starter, T12 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSO-T12KP with TH-T18KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSO-T12KP with TH-T18KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T12KP 0.12A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.12A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.17A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.24A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.35A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.5A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.7A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 0.9A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.3A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 1.7A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.1A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 2.5A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 3.6A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 5A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 6.6A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 9A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC24V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC48V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC100V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC200V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC300V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC400V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T12KP 11A AC500V | MSO-T12KP non-reversing starter with 2E thermal, T12 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T20 Magnetic Starter (18A AC-3, T20 Frame, TH-T18 Thermal)
▶Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSO-T20: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSO-T20: AC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T20 0.12A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.12A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.17A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.24A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.35A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.5A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.7A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC24V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC48V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC100V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC200V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC300V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC400V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 0.9A AC500V | MSO-T20 non-reversing starter, T20 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC24V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC48V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC100V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC200V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC300V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC400V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.3A AC500V | MSO-T20 non-reversing starter, T20 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC24V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC48V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC100V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC200V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC300V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC400V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 1.7A AC500V | MSO-T20 non-reversing starter, T20 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC24V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC48V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC100V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC200V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC300V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC400V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.1A AC500V | MSO-T20 non-reversing starter, T20 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC24V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC48V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC100V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC200V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC300V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC400V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 2.5A AC500V | MSO-T20 non-reversing starter, T20 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC24V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC48V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC100V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC200V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC300V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC400V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 3.6A AC500V | MSO-T20 non-reversing starter, T20 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC24V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC48V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC100V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC200V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC300V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC400V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 5A AC500V | MSO-T20 non-reversing starter, T20 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC24V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC48V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC100V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC200V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC300V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC400V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 6.6A AC500V | MSO-T20 non-reversing starter, T20 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC24V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC48V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC100V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC200V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC300V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC400V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 9A AC500V | MSO-T20 non-reversing starter, T20 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC24V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC48V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC100V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC200V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC300V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC400V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 11A AC500V | MSO-T20 non-reversing starter, T20 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC24V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC48V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC100V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC200V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC300V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC400V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20 15A AC500V | MSO-T20 non-reversing starter, T20 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSO-T20KP with TH-T18KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSO-T20KP with TH-T18KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T20KP 0.12A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.12A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.12A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.17A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.17A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.24A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.35A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.5A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.7A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 0.9A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.3A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 1.7A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.1A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 2.5A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 3.6A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 5A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 6.6A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 9A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 11A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC24V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC48V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC100V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC200V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC300V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC400V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T20KP 15A AC500V | MSO-T20KP non-reversing starter with 2E thermal, T20 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T18KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T21 Magnetic Starter (18A AC-3, T21 Frame, TH-T25 Thermal)
▶Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSO-T21: AC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSO-T21: AC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T21 0.24A AC24V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC48V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC100V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC200V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC300V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC400V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.24A AC500V | MSO-T21 non-reversing starter, T21 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC24V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC48V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC100V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC200V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC300V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC400V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.35A AC500V | MSO-T21 non-reversing starter, T21 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC24V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC48V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC100V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC200V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC300V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC400V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.5A AC500V | MSO-T21 non-reversing starter, T21 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC24V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC48V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC100V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC200V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC300V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC400V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.7A AC500V | MSO-T21 non-reversing starter, T21 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC24V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC48V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC100V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC200V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC300V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC400V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 0.9A AC500V | MSO-T21 non-reversing starter, T21 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC24V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC48V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC100V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC200V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC300V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC400V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.3A AC500V | MSO-T21 non-reversing starter, T21 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC24V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC48V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC100V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC200V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC300V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC400V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 1.7A AC500V | MSO-T21 non-reversing starter, T21 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC24V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC48V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC100V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC200V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC300V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC400V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.1A AC500V | MSO-T21 non-reversing starter, T21 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC24V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC48V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC100V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC200V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC300V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC400V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 2.5A AC500V | MSO-T21 non-reversing starter, T21 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC24V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC48V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC100V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC200V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC300V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC400V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 3.6A AC500V | MSO-T21 non-reversing starter, T21 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC24V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC48V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC100V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC200V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC300V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC400V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 5A AC500V | MSO-T21 non-reversing starter, T21 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC24V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC48V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC100V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC200V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC300V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC400V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 6.6A AC500V | MSO-T21 non-reversing starter, T21 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC24V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC48V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC100V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC200V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC300V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC400V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 9A AC500V | MSO-T21 non-reversing starter, T21 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC24V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC48V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC100V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC200V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC300V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC400V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 11A AC500V | MSO-T21 non-reversing starter, T21 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC24V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC48V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC100V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC200V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC300V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC400V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21 15A AC500V | MSO-T21 non-reversing starter, T21 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSO-T21KP with TH-T25KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSO-T21KP with TH-T25KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T21KP 0.24A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.24A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.35A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.5A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.7A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 0.9A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.3A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 1.7A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.1A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 2.5A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 3.6A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 5A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 6.6A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 9A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 11A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC24V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC48V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC100V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC200V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC300V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC400V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T21KP 15A AC500V | MSO-T21KP non-reversing starter with 2E thermal, T21 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T25 Magnetic Starter (26A AC-3, T25 Frame, TH-T25 Thermal)
▶Mitsubishi Electric MS-T/N series T25-frame non-reversing open-type magnetic starter MSO-T25: AC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 5.5kW / 26A (AC-3) at 200-220V and 11kW / 25A at 380-440V, Ith 32A. Heater designations 0.24A to 22A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T25-frame non-reversing open-type magnetic starter MSO-T25: AC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 5.5kW / 26A (AC-3) at 200-220V and 11kW / 25A at 380-440V, Ith 32A. Heater designations 0.24A to 22A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T25 0.24A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.24A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.35A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.5A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.7A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC24V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC48V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC100V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC200V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC300V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC400V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 0.9A AC500V | MSO-T25 non-reversing starter, T25 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC24V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC48V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC100V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC200V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC300V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC400V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.3A AC500V | MSO-T25 non-reversing starter, T25 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC24V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC48V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC100V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC200V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC300V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC400V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 1.7A AC500V | MSO-T25 non-reversing starter, T25 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC24V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC48V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC100V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC200V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC300V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC400V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.1A AC500V | MSO-T25 non-reversing starter, T25 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC24V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC48V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC100V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC200V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC300V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC400V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 2.5A AC500V | MSO-T25 non-reversing starter, T25 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC24V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC48V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC100V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC200V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC300V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC400V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 3.6A AC500V | MSO-T25 non-reversing starter, T25 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC24V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC48V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC100V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC200V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC300V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC400V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 5A AC500V | MSO-T25 non-reversing starter, T25 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC24V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC48V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC100V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC200V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC300V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC400V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 6.6A AC500V | MSO-T25 non-reversing starter, T25 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC24V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC48V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC100V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC200V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC300V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC400V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 9A AC500V | MSO-T25 non-reversing starter, T25 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC24V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC48V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC100V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC200V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC300V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC400V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 11A AC500V | MSO-T25 non-reversing starter, T25 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC24V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC48V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC100V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC200V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC300V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC400V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 15A AC500V | MSO-T25 non-reversing starter, T25 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC24V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC48V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC100V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC200V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC300V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC400V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25 22A AC500V | MSO-T25 non-reversing starter, T25 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T25-frame non-reversing open-type magnetic starter MSO-T25KP with TH-T25KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 5.5kW / 26A (AC-3) at 200-220V and 11kW / 25A at 380-440V, Ith 32A. Heater designations 0.24A to 22A (16 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T25-frame non-reversing open-type magnetic starter MSO-T25KP with TH-T25KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 5.5kW / 26A (AC-3) at 200-220V and 11kW / 25A at 380-440V, Ith 32A. Heater designations 0.24A to 22A (16 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T25KP 0.24A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.24A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.35A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.5A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.7A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 0.9A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.3A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 1.7A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.1A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 2.5A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 3.6A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 5A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 6.6A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 9A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 11A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 15A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC24V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC48V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC100V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC200V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC300V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC400V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T25KP 22A AC500V | MSO-T25KP non-reversing starter with 2E thermal, T25 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T25 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 5.5kW@200-220V / 11kW@380-440V / 11kW@500-550V · AC-3 Current: 26A@200-220V / 25A@380-440V / 20A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T35-frame non-reversing open-type magnetic starter MSO-T35: AC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T35-frame non-reversing open-type magnetic starter MSO-T35: AC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T35 0.24A AC24V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC48V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC100V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC200V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC300V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC400V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.24A AC500V | MSO-T35 non-reversing starter, T35 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC24V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC48V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC100V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC200V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC300V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC400V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.35A AC500V | MSO-T35 non-reversing starter, T35 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC24V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC48V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC100V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC200V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC300V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC400V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.5A AC500V | MSO-T35 non-reversing starter, T35 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC24V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC48V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC100V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC200V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC300V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC400V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.7A AC500V | MSO-T35 non-reversing starter, T35 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC24V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC48V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC100V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC200V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC300V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC400V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 0.9A AC500V | MSO-T35 non-reversing starter, T35 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC24V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC48V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC100V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC200V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC300V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC400V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.3A AC500V | MSO-T35 non-reversing starter, T35 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC24V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC48V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC100V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC200V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC300V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC400V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 1.7A AC500V | MSO-T35 non-reversing starter, T35 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC24V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC48V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC100V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC200V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC300V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC400V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.1A AC500V | MSO-T35 non-reversing starter, T35 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC24V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC48V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC100V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC200V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC300V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC400V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 2.5A AC500V | MSO-T35 non-reversing starter, T35 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC24V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC48V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC100V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC200V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC300V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC400V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 3.6A AC500V | MSO-T35 non-reversing starter, T35 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC24V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC48V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC100V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC200V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC300V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC400V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 5A AC500V | MSO-T35 non-reversing starter, T35 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC24V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC48V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC100V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC200V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC300V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC400V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 6.6A AC500V | MSO-T35 non-reversing starter, T35 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC24V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC48V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC100V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC200V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC300V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC400V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 9A AC500V | MSO-T35 non-reversing starter, T35 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC24V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC48V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC100V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC200V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC300V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC400V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 11A AC500V | MSO-T35 non-reversing starter, T35 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC24V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC48V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC100V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC200V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC300V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC400V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 15A AC500V | MSO-T35 non-reversing starter, T35 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC24V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC48V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC100V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC200V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC300V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC400V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 22A AC500V | MSO-T35 non-reversing starter, T35 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC24V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC48V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC100V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC200V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC300V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC400V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35 29A AC500V | MSO-T35 non-reversing starter, T35 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T35-frame non-reversing open-type magnetic starter MSO-T35KP with TH-T25/T50KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T35-frame non-reversing open-type magnetic starter MSO-T35KP with TH-T25/T50KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T35KP 0.24A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.24A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.35A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.5A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.7A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 0.9A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.3A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 1.7A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.1A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 2.5A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 3.6A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 5A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 6.6A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 9A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 11A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 15A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 22A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC24V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC48V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC100V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC200V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC300V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC400V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T35KP 29A AC500V | MSO-T35KP non-reversing starter with 2E thermal, T35 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T35 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T50-frame non-reversing open-type magnetic starter MSO-T50: AC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T50-frame non-reversing open-type magnetic starter MSO-T50: AC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T50 0.24A AC24V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC48V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC100V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC200V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC300V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC400V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.24A AC500V | MSO-T50 non-reversing starter, T50 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC24V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC48V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC100V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC200V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC300V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC400V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.35A AC500V | MSO-T50 non-reversing starter, T50 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC24V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC48V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC100V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC200V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC300V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC400V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.5A AC500V | MSO-T50 non-reversing starter, T50 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC24V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC48V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC100V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC200V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC300V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC400V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.7A AC500V | MSO-T50 non-reversing starter, T50 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC24V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC48V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC100V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC200V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC300V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC400V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 0.9A AC500V | MSO-T50 non-reversing starter, T50 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC24V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC48V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC100V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC200V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC300V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC400V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.3A AC500V | MSO-T50 non-reversing starter, T50 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC24V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC48V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC100V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC200V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC300V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC400V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 1.7A AC500V | MSO-T50 non-reversing starter, T50 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC24V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC48V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC100V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC200V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC300V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC400V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.1A AC500V | MSO-T50 non-reversing starter, T50 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC24V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC48V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC100V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC200V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC300V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC400V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 2.5A AC500V | MSO-T50 non-reversing starter, T50 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC24V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC48V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC100V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC200V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC300V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC400V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 3.6A AC500V | MSO-T50 non-reversing starter, T50 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC24V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC48V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC100V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC200V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC300V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC400V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 5A AC500V | MSO-T50 non-reversing starter, T50 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC24V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC48V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC100V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC200V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC300V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC400V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 6.6A AC500V | MSO-T50 non-reversing starter, T50 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC24V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC48V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC100V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC200V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC300V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC400V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 9A AC500V | MSO-T50 non-reversing starter, T50 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC24V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC48V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC100V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC200V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC300V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC400V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 11A AC500V | MSO-T50 non-reversing starter, T50 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC24V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC48V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC100V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC200V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC300V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC400V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 15A AC500V | MSO-T50 non-reversing starter, T50 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC24V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC48V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC100V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC200V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC300V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC400V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 22A AC500V | MSO-T50 non-reversing starter, T50 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC24V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC48V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC100V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC200V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC300V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC400V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 29A AC500V | MSO-T50 non-reversing starter, T50 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC24V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC48V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC100V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC200V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC300V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC400V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 35A AC500V | MSO-T50 non-reversing starter, T50 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC24V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC48V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC100V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC200V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC300V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC400V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50 42A AC500V | MSO-T50 non-reversing starter, T50 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T50-frame non-reversing open-type magnetic starter MSO-T50KP with TH-T25/T50KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T50-frame non-reversing open-type magnetic starter MSO-T50KP with TH-T25/T50KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T50KP 0.24A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.24A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.24A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.35A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.5A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.7A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 0.9A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 0.9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.3A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.3A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 1.7A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 1.7A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.1A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.1A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 2.5A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 2.5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 3.6A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 3.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 5A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 5A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 6.6A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 6.6A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 9A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 9A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 11A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 11A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 15A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 22A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T25KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 29A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 35A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC24V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC48V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC100V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC200V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC300V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-300V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC400V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T50KP 42A AC500V | MSO-T50KP non-reversing starter with 2E thermal, T50 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T50 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T50KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
[MITSUBISHI ELECTRIC] — MS-T/N Series MSO-T65 Magnetic Starter (65A AC-3, T65 Frame, TH-T65 Thermal)
▶Mitsubishi Electric MS-T/N series T65-frame non-reversing open-type magnetic starter MSO-T65: AC-operated contactor combined with TH-T65 2-element thermal overload relay (manual reset standard). Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T65-frame non-reversing open-type magnetic starter MSO-T65: AC-operated contactor combined with TH-T65 2-element thermal overload relay (manual reset standard). Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T65 15A AC24V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC48V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC100V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC200V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC300V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC400V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 15A AC500V | MSO-T65 non-reversing starter, T65 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC24V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC48V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC100V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC200V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC300V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC400V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 22A AC500V | MSO-T65 non-reversing starter, T65 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC24V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC48V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC100V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC200V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC300V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC400V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 29A AC500V | MSO-T65 non-reversing starter, T65 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC24V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC48V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC100V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC200V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC300V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC400V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 35A AC500V | MSO-T65 non-reversing starter, T65 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC24V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC48V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC100V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC200V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC300V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC400V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 42A AC500V | MSO-T65 non-reversing starter, T65 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC24V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC48V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC100V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC200V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC300V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC400V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65 54A AC500V | MSO-T65 non-reversing starter, T65 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T65-frame non-reversing open-type magnetic starter MSO-T65KP with TH-T65KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T65-frame non-reversing open-type magnetic starter MSO-T65KP with TH-T65KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T65KP 15A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 15A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 15A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 22A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 22A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 29A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 29A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 35A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 35A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 42A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 42A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC24V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC24V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC48V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC48V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC100V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC100V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC200V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC200V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC300V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC300V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC400V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC400V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T65KP 54A AC500V | MSO-T65KP non-reversing starter with 2E thermal, T65 frame, 54A heater, AC500V coil | Mitsubishi Electric | Frame: T65 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T65KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T80-frame non-reversing open-type magnetic starter MSO-T80: AC-operated contactor combined with TH-T100 2-element thermal overload relay (manual reset standard). Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T80-frame non-reversing open-type magnetic starter MSO-T80: AC-operated contactor combined with TH-T100 2-element thermal overload relay (manual reset standard). Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T80 67A AC24V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC48V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC100V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC200V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC300V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC400V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80 67A AC500V | MSO-T80 non-reversing starter, T80 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T80-frame non-reversing open-type magnetic starter MSO-T80KP with TH-T100KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
Mitsubishi Electric MS-T/N series T80-frame non-reversing open-type magnetic starter MSO-T80KP with TH-T100KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. AC-operated, rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSO-T80KP 67A AC24V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC24V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC24V (24V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC48V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC48V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC48V (48-50V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC100V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC100V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC100V (100-127V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC200V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC200V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC200V (200-240V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC300V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC300V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC300V (260-350V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC400V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC400V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC400V (380-440V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSO-T80KP 67A AC500V | MSO-T80KP non-reversing starter with 2E thermal, T80 frame, 67A heater, AC500V coil | Mitsubishi Electric | Frame: T80 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: AC operated · Coil: AC500V (460-550V 50/60Hz) · Thermal Relay: TH-T100KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N125-frame reversing open-type magnetic starter MSOD-2xN125: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series N125-frame reversing open-type magnetic starter MSOD-2xN125: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN125 42A DC12V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC24V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC48V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC100V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC110V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC125V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC200V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 42A DC220V | MSOD-2xN125 reversing starter, N125 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC12V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC24V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC48V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC100V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC110V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC125V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC200V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 54A DC220V | MSOD-2xN125 reversing starter, N125 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC12V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC24V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC48V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC100V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC110V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC125V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC200V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 67A DC220V | MSOD-2xN125 reversing starter, N125 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC12V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC24V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC48V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC100V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC110V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC125V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC200V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 82A DC220V | MSOD-2xN125 reversing starter, N125 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC12V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC24V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC48V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC100V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC110V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC125V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC200V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125 105A DC220V | MSOD-2xN125 reversing starter, N125 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N125-frame reversing open-type magnetic starter MSOD-2xN125KP with TH-N120(TA)KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. DC-operated, rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N125-frame reversing open-type magnetic starter MSOD-2xN125KP with TH-N120(TA)KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. DC-operated, rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN125KP 42A DC12V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC24V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC48V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC100V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC110V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC125V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC200V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 42A DC220V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC12V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC24V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC48V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC100V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC110V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC125V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC200V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 54A DC220V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC12V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC24V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC48V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC100V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC110V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC125V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC200V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 67A DC220V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC12V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC24V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC48V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC100V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC110V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC125V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC200V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 82A DC220V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC12V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC24V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC48V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC100V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC110V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC125V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC200V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN125KP 105A DC220V | MSOD-2xN125KP reversing starter with 2E thermal, N125 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N150-frame reversing open-type magnetic starter MSOD-2xN150: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series N150-frame reversing open-type magnetic starter MSOD-2xN150: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN150 42A DC12V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC24V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC48V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC100V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC110V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC125V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC200V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 42A DC220V | MSOD-2xN150 reversing starter, N150 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC12V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC24V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC48V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC100V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC110V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC125V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC200V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 54A DC220V | MSOD-2xN150 reversing starter, N150 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC12V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC24V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC48V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC100V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC110V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC125V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC200V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 67A DC220V | MSOD-2xN150 reversing starter, N150 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC12V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC24V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC48V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC100V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC110V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC125V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC200V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 82A DC220V | MSOD-2xN150 reversing starter, N150 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC12V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC24V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC48V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC100V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC110V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC125V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC200V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 105A DC220V | MSOD-2xN150 reversing starter, N150 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC12V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC24V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC48V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC100V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC110V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC125V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC200V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150 125A DC220V | MSOD-2xN150 reversing starter, N150 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N150-frame reversing open-type magnetic starter MSOD-2xN150KP with TH-N120(TA)KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. DC-operated, rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching.
Mitsubishi Electric MS-T/N series N150-frame reversing open-type magnetic starter MSOD-2xN150KP with TH-N120(TA)KP 3-element (2E) thermal overload relay providing combined overload and open-phase (single-phasing) protection. DC-operated, rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps). Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4. Mechanical interlock fitted as standard for forward/reverse switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN150KP 42A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 42A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 54A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 67A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 82A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120KP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 105A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC12V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC24V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC48V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC100V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC110V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC125V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC200V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN150KP 125A DC220V | MSOD-2xN150KP reversing starter with 2E thermal, N150 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TAKP (3-element 2E, manual reset) · Protection: Overload + Open-phase · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |