Molded Case Circuit Breakers
LS ELECTRIC Susol Smart MCCB TS800Hi family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 100kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS800Hi family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 100kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800Hi-ETSi-630A-3P | Susol Smart MCCB TS800Hi — 630A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETSi-630A-4PL | Susol Smart MCCB TS800Hi — 630A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETSi-630A-4PR | Susol Smart MCCB TS800Hi — 630A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-630A-3P | Susol Smart MCCB TS800Hi — 630A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-630A-4PL | Susol Smart MCCB TS800Hi — 630A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-630A-4PR | Susol Smart MCCB TS800Hi — 630A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-630A-3P | Susol Smart MCCB TS800Hi — 630A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-630A-4PL | Susol Smart MCCB TS800Hi — 630A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-630A-4PR | Susol Smart MCCB TS800Hi — 630A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-630A-3P | Susol Smart MCCB TS800Hi — 630A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-630A-4PL | Susol Smart MCCB TS800Hi — 630A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-630A-4PR | Susol Smart MCCB TS800Hi — 630A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETSi-800A-3P | Susol Smart MCCB TS800Hi — 800A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETSi-800A-4PL | Susol Smart MCCB TS800Hi — 800A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETSi-800A-4PR | Susol Smart MCCB TS800Hi — 800A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-800A-3P | Susol Smart MCCB TS800Hi — 800A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-800A-4PL | Susol Smart MCCB TS800Hi — 800A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETMi-800A-4PR | Susol Smart MCCB TS800Hi — 800A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-800A-3P | Susol Smart MCCB TS800Hi — 800A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-800A-4PL | Susol Smart MCCB TS800Hi — 800A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETHi-800A-4PR | Susol Smart MCCB TS800Hi — 800A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-800A-3P | Susol Smart MCCB TS800Hi — 800A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-800A-4PL | Susol Smart MCCB TS800Hi — 800A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Hi-ETLi-800A-4PR | Susol Smart MCCB TS800Hi — 800A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 100kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800L-ETM family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETM (Electronic Trip Unit Multi-Function) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800L-ETM family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETM (Electronic Trip Unit Multi-Function) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800L-ETM800-630A-2P | Susol MCCB TS800L-ETM — 630A ETM800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-630A-3P | Susol MCCB TS800L-ETM — 630A ETM800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-630A-4PL | Susol MCCB TS800L-ETM — 630A ETM800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-630A-4PR | Susol MCCB TS800L-ETM — 630A ETM800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-800A-2P | Susol MCCB TS800L-ETM — 800A ETM800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-800A-3P | Susol MCCB TS800L-ETM — 800A ETM800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-800A-4PL | Susol MCCB TS800L-ETM — 800A ETM800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETM800-800A-4PR | Susol MCCB TS800L-ETM — 800A ETM800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800L-ETS family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800L-ETS family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800L-ETS800-630A-2P | Susol MCCB TS800L-ETS — 630A ETS800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-630A-3P | Susol MCCB TS800L-ETS — 630A ETS800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-630A-4PL | Susol MCCB TS800L-ETS — 630A ETS800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-630A-4PR | Susol MCCB TS800L-ETS — 630A ETS800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-800A-2P | Susol MCCB TS800L-ETS — 800A ETS800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-800A-3P | Susol MCCB TS800L-ETS — 800A ETS800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-800A-4PL | Susol MCCB TS800L-ETS — 800A ETS800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-ETS800-800A-4PR | Susol MCCB TS800L-ETS — 800A ETS800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800L-FTU family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 700A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800L-FTU family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 150kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 700A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800L-FTU800-700A-2P | Susol MCCB TS800L-FTU — 700A FTU800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-700A-3P | Susol MCCB TS800L-FTU — 700A FTU800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-700A-4PL | Susol MCCB TS800L-FTU — 700A FTU800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-700A-4PR | Susol MCCB TS800L-FTU — 700A FTU800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-800A-2P | Susol MCCB TS800L-FTU — 800A FTU800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-800A-3P | Susol MCCB TS800L-FTU — 800A FTU800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-800A-4PL | Susol MCCB TS800L-FTU — 800A FTU800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800L-FTU800-800A-4PR | Susol MCCB TS800L-FTU — 800A FTU800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS800Li family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 150kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS800Li family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 150kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800Li-ETSi-630A-3P | Susol Smart MCCB TS800Li — 630A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETSi-630A-4PL | Susol Smart MCCB TS800Li — 630A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETSi-630A-4PR | Susol Smart MCCB TS800Li — 630A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-630A-3P | Susol Smart MCCB TS800Li — 630A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-630A-4PL | Susol Smart MCCB TS800Li — 630A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-630A-4PR | Susol Smart MCCB TS800Li — 630A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-630A-3P | Susol Smart MCCB TS800Li — 630A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-630A-4PL | Susol Smart MCCB TS800Li — 630A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-630A-4PR | Susol Smart MCCB TS800Li — 630A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-630A-3P | Susol Smart MCCB TS800Li — 630A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-630A-4PL | Susol Smart MCCB TS800Li — 630A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-630A-4PR | Susol Smart MCCB TS800Li — 630A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETSi-800A-3P | Susol Smart MCCB TS800Li — 800A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETSi-800A-4PL | Susol Smart MCCB TS800Li — 800A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETSi-800A-4PR | Susol Smart MCCB TS800Li — 800A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-800A-3P | Susol Smart MCCB TS800Li — 800A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-800A-4PL | Susol Smart MCCB TS800Li — 800A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETMi-800A-4PR | Susol Smart MCCB TS800Li — 800A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-800A-3P | Susol Smart MCCB TS800Li — 800A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-800A-4PL | Susol Smart MCCB TS800Li — 800A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETHi-800A-4PR | Susol Smart MCCB TS800Li — 800A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-800A-3P | Susol Smart MCCB TS800Li — 800A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-800A-4PL | Susol Smart MCCB TS800Li — 800A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Li-ETLi-800A-4PR | Susol Smart MCCB TS800Li — 800A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 150kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800N-ETM family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: ETM (Electronic Trip Unit Multi-Function) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800N-ETM family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: ETM (Electronic Trip Unit Multi-Function) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800N-ETM800-630A-2P | Susol MCCB TS800N-ETM — 630A ETM800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-630A-3P | Susol MCCB TS800N-ETM — 630A ETM800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-630A-4PL | Susol MCCB TS800N-ETM — 630A ETM800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-630A-4PR | Susol MCCB TS800N-ETM — 630A ETM800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-800A-2P | Susol MCCB TS800N-ETM — 800A ETM800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-800A-3P | Susol MCCB TS800N-ETM — 800A ETM800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-800A-4PL | Susol MCCB TS800N-ETM — 800A ETM800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETM800-800A-4PR | Susol MCCB TS800N-ETM — 800A ETM800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETM800 (Electronic) | Trip features: Adjustable In, LSIG protection (Long/Short/Instantaneous/Ground fault), 30-step, communication option (Z/A/E/C) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800N-ETS family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800N-ETS family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: ETS (Electronic Trip Unit Standard) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Rated current (In): 630A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800N-ETS800-630A-2P | Susol MCCB TS800N-ETS — 630A ETS800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-630A-3P | Susol MCCB TS800N-ETS — 630A ETS800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-630A-4PL | Susol MCCB TS800N-ETS — 630A ETS800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-630A-4PR | Susol MCCB TS800N-ETS — 630A ETS800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-800A-2P | Susol MCCB TS800N-ETS — 800A ETS800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-800A-3P | Susol MCCB TS800N-ETS — 800A ETS800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-800A-4PL | Susol MCCB TS800N-ETS — 800A ETS800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-ETS800-800A-4PR | Susol MCCB TS800N-ETS — 800A ETS800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETS800 (Electronic) | Trip features: Adjustable In, LSI protection (Long-time, Short-time, Instantaneous), 13-step adjustment | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol MCCB TS800N-FTU family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 700A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol MCCB TS800N-FTU family. Frame: 800AF | Breaking capacity Icu @ 415V AC: 65kA | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed rated current and instantaneous trip (10×In) | Rated current (In): 700A, 800A | Pole: 2P / 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800N-FTU800-700A-2P | Susol MCCB TS800N-FTU — 700A FTU800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-700A-3P | Susol MCCB TS800N-FTU — 700A FTU800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-700A-4PL | Susol MCCB TS800N-FTU — 700A FTU800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-700A-4PR | Susol MCCB TS800N-FTU — 700A FTU800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 700A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-800A-2P | Susol MCCB TS800N-FTU — 800A FTU800, 2-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 2-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-800A-3P | Susol MCCB TS800N-FTU — 800A FTU800, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Weight: 13.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-800A-4PL | Susol MCCB TS800N-FTU — 800A FTU800, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 좌측 (N-L1-L2-L3) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800N-FTU800-800A-4PR | Susol MCCB TS800N-FTU — 800A FTU800, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: FTU800 (Thermal-Magnetic) | Trip features: Fixed rated current and instantaneous trip (10×In) | Pole: 4-pole — N극 우측 (L1-L2-L3-N) | Dimensions (W×H×D): 280×320×135 mm | Weight: 17.0 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Smart MCCB TS800Ni family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 65kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
LS ELECTRIC Susol Smart MCCB TS800Ni family. Frame: 800AF | Rated current: 630A, 800A | Icu @ 415V AC: 65kA | Trip units: ETSi / ETMi / ETHi / ETLi (LSIG protection) | Pole: 3P / 4P (N-arrangement L or R) | Standard: IEC 60947-2 | 24 variants available — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TS800Ni-ETSi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-3P | Susol Smart MCCB TS800Ni — 630A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-4PL | Susol Smart MCCB TS800Ni — 630A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-630A-4PR | Susol Smart MCCB TS800Ni — 630A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 630A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETSi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETSi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETSi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETSi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETSi (Standard) | Trip features: LSIG protection, current metering | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETMi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETMi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETMi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETMi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETMi (Multi-Function) | Trip features: LSIG protection, current metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETHi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETHi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETHi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETHi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETHi (High-Performance) | Trip features: LSIG protection, current/voltage/power metering, RS485 communication | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-3P | Susol Smart MCCB TS800Ni — 800A ETLi, 3-pole | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 3-pole | Dimensions (W×H×D): 210×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-4PL | Susol Smart MCCB TS800Ni — 800A ETLi, 4-pole (L) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 좌측 (N-A-B-C) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | |
| TS800Ni-ETLi-800A-4PR | Susol Smart MCCB TS800Ni — 800A ETLi, 4-pole (R) | LS ELECTRIC | Frame: 800AF | Rated current (In): 800A @ 40°C | Breaking capacity Icu: 65kA @ 415V AC | Trip unit: ETLi (Limited (Mobile)) | Trip features: LSIG protection, current/voltage/power metering, RS485 + BLE mobile | Pole: 4-pole — N극 우측 (A-B-C-N) | Dimensions (W×H×D): 280×320×135 mm | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-ATU-100A-3P | Susol Beyond X UTV250-E-ATU-IEC — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-100A-4P | Susol Beyond X UTV250-E-ATU-IEC — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-3P | Susol Beyond X UTV250-E-ATU-IEC — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-4P | Susol Beyond X UTV250-E-ATU-IEC — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-3P | Susol Beyond X UTV250-E-ATU-IEC — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-4P | Susol Beyond X UTV250-E-ATU-IEC — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-3P | Susol Beyond X UTV250-E-ATU-IEC — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-4P | Susol Beyond X UTV250-E-ATU-IEC — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-ATU-100A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-100A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-150A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-200A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-3P-UL | Susol Beyond X UTV250-E-ATU-UL — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-ATU-250A-4P-UL | Susol Beyond X UTV250-E-ATU-UL — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FMU-60A-3P | Susol Beyond X UTV250-E-FMU-IEC — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-60A-4P | Susol Beyond X UTV250-E-FMU-IEC — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-3P | Susol Beyond X UTV250-E-FMU-IEC — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-4P | Susol Beyond X UTV250-E-FMU-IEC — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-3P | Susol Beyond X UTV250-E-FMU-IEC — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-4P | Susol Beyond X UTV250-E-FMU-IEC — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-3P | Susol Beyond X UTV250-E-FMU-IEC — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-4P | Susol Beyond X UTV250-E-FMU-IEC — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-3P | Susol Beyond X UTV250-E-FMU-IEC — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-4P | Susol Beyond X UTV250-E-FMU-IEC — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-3P | Susol Beyond X UTV250-E-FMU-IEC — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-4P | Susol Beyond X UTV250-E-FMU-IEC — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FMU-60A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-60A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-80A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-100A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-150A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-200A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-3P-UL | Susol Beyond X UTV250-E-FMU-UL — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FMU-250A-4P-UL | Susol Beyond X UTV250-E-FMU-UL — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 15kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FTU-60A-3P | Susol Beyond X UTV250-E-FTU-IEC — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-60A-4P | Susol Beyond X UTV250-E-FTU-IEC — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-3P | Susol Beyond X UTV250-E-FTU-IEC — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-4P | Susol Beyond X UTV250-E-FTU-IEC — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-3P | Susol Beyond X UTV250-E-FTU-IEC — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-4P | Susol Beyond X UTV250-E-FTU-IEC — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-3P | Susol Beyond X UTV250-E-FTU-IEC — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-4P | Susol Beyond X UTV250-E-FTU-IEC — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-3P | Susol Beyond X UTV250-E-FTU-IEC — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-4P | Susol Beyond X UTV250-E-FTU-IEC — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-3P | Susol Beyond X UTV250-E-FTU-IEC — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-4P | Susol Beyond X UTV250-E-FTU-IEC — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 15kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-E-FTU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 25kA @ 800V AC, 14kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-E-FTU-60A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-60A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-80A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-100A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-150A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-200A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-3P-UL | Susol Beyond X UTV250-E-FTU-UL — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-E-FTU-250A-4P-UL | Susol Beyond X UTV250-E-FTU-UL — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 25kA @ 800V AC, 14kA @ 1000V AC | Breaker type: E (Economic, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-ATU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, ATU 100~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-ATU-100A-3P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-100A-4P | Susol Beyond X UTV250-N-ATU-IEC — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-3P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-4P | Susol Beyond X UTV250-N-ATU-IEC — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-3P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-4P | Susol Beyond X UTV250-N-ATU-IEC — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-3P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-4P | Susol Beyond X UTV250-N-ATU-IEC — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-ATU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: ATU (Fully Adjustable Trip Unit) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Rated current (In): 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 8 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-ATU-100A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 100A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-100A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 100A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 150A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-150A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 150A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 200A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-200A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 200A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-3P-UL | Susol Beyond X UTV250-N-ATU-UL — 250A ATU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-ATU-250A-4P-UL | Susol Beyond X UTV250-N-ATU-UL — 250A ATU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: ATU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), adjustable magnetic (Ii=5~10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-FMU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FMU 60~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FMU-60A-3P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-60A-4P | Susol Beyond X UTV250-N-FMU-IEC — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-3P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-4P | Susol Beyond X UTV250-N-FMU-IEC — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-3P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-4P | Susol Beyond X UTV250-N-FMU-IEC — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-3P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-4P | Susol Beyond X UTV250-N-FMU-IEC — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-3P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-4P | Susol Beyond X UTV250-N-FMU-IEC — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-3P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-4P | Susol Beyond X UTV250-N-FMU-IEC — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FMU-UL family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FMU (Adjustable Thermal Trip Unit (Fixed Magnetic)) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FMU-60A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 60A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-60A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 60A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 80A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-80A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 80A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 100A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-100A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 100A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 150A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-150A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 150A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 200A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-200A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 200A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-3P-UL | Susol Beyond X UTV250-N-FMU-UL — 250A FMU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FMU-250A-4P-UL | Susol Beyond X UTV250-N-FMU-UL — 250A FMU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FMU (Thermal-Magnetic) | Trip features: Adjustable thermal (Ir=0.8~1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: UL489 + CSA | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |
[LS ELECTRIC] — UTV250-N-FTU-IEC Susol Beyond X MCCB (Normal, 42kA @ 800V, FTU 60~250A, IEC60947-2)
▶LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
LS ELECTRIC Susol Beyond X MCCB UTV250-N-FTU-IEC family. For renewable energy and high altitude applications. Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Breaking capacity: 42kA @ 800V AC, 20kA @ 1000V AC | Trip unit: FTU (Fixed Trip Unit (Thermal-Magnetic)) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Rated current (In): 60A, 80A, 100A, 150A, 200A, 250A | Pole: 3P / 4P | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | 12 variants — see RFQ table for specific MPN.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UTV250-N-FTU-60A-3P | Susol Beyond X UTV250-N-FTU-IEC — 60A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-60A-4P | Susol Beyond X UTV250-N-FTU-IEC — 60A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 60A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-3P | Susol Beyond X UTV250-N-FTU-IEC — 80A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-80A-4P | Susol Beyond X UTV250-N-FTU-IEC — 80A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 80A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-3P | Susol Beyond X UTV250-N-FTU-IEC — 100A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-100A-4P | Susol Beyond X UTV250-N-FTU-IEC — 100A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 100A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-3P | Susol Beyond X UTV250-N-FTU-IEC — 150A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-150A-4P | Susol Beyond X UTV250-N-FTU-IEC — 150A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 150A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-3P | Susol Beyond X UTV250-N-FTU-IEC — 200A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-200A-4P | Susol Beyond X UTV250-N-FTU-IEC — 200A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 200A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-3P | Susol Beyond X UTV250-N-FTU-IEC — 250A FTU, 3-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 3-pole | Dimensions (W×H×D): 105×205×92 mm | Weight: 2.2 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude | |
| UTV250-N-FTU-250A-4P | Susol Beyond X UTV250-N-FTU-IEC — 250A FTU, 4-pole | LS ELECTRIC | Frame: 250AF | Rated voltage: 690*/800/1000 Vac (* 690V 출시 예정) | Rated current (In): 250A @ 40°C | Breaking capacity Icu: 42kA @ 800V AC, 20kA @ 1000V AC | Breaker type: N (Normal, 80% rating; ET/NT 100% rating versions also available) | Trip unit: FTU (Thermal-Magnetic) | Trip features: Fixed thermal (Ir=1×In), fixed magnetic (Ii=10×In) | Pole: 4-pole | Dimensions (W×H×D): 140×205×92 mm | Weight: 2.88 kg | Standard: IEC 60947-2 | Ui 1000V | Uimp 8kV | Application: Renewable energy (Solar PV, Wind), High altitude |