Electrical
K2CU-F Heater Element Burnout Detector with Gate Input Terminals. Large-capacity, built-in current transformer. With voltage fluctuation compensation.
K2CU-F Heater Element Burnout Detector with Gate Input Terminals. Large-capacity, built-in current transformer. With voltage fluctuation compensation.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K2CU-F10A-CGS | K2CU-F10A with gate input 100 VAC 4~10 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 100 VAC | Operating Current: 4~10 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F20A-CGS | K2CU-F20A with gate input 100 VAC 8~20 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 100 VAC | Operating Current: 8~20 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F40A-CGS | K2CU-F40A with gate input 100 VAC 16~40 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 100 VAC | Operating Current: 16~40 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F80A-CGS | K2CU-F80A with gate input 100 VAC 32~80 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 100 VAC | Operating Current: 32~80 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F10A-DGS | K2CU-F10A with gate input 110 VAC 4~10 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 110 VAC | Operating Current: 4~10 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F20A-DGS | K2CU-F20A with gate input 110 VAC 8~20 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 110 VAC | Operating Current: 8~20 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F40A-DGS | K2CU-F40A with gate input 110 VAC 16~40 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 110 VAC | Operating Current: 16~40 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F80A-DGS | K2CU-F80A with gate input 110 VAC 32~80 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 110 VAC | Operating Current: 32~80 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F10A-EGS | K2CU-F10A with gate input 200 VAC 4~10 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 200 VAC | Operating Current: 4~10 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F20A-EGS | K2CU-F20A with gate input 200 VAC 8~20 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 200 VAC | Operating Current: 8~20 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F40A-EGS | K2CU-F40A with gate input 200 VAC 16~40 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 200 VAC | Operating Current: 16~40 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F80A-EGS | K2CU-F80A with gate input 200 VAC 32~80 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 200 VAC | Operating Current: 32~80 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F10A-FGS | K2CU-F10A with gate input 220 VAC 4~10 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 220 VAC | Operating Current: 4~10 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F20A-FGS | K2CU-F20A with gate input 220 VAC 8~20 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 220 VAC | Operating Current: 8~20 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F40A-FGS | K2CU-F40A with gate input 220 VAC 16~40 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 220 VAC | Operating Current: 16~40 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU | |
| K2CU-F80A-FGS | K2CU-F80A with gate input 220 VAC 32~80 A | OMRON | Type: Heater Element Burnout Detector | Model: F-GS (Gate Input) | Control Supply Voltage: 220 VAC | Operating Current: 32~80 A | Voltage Fluctuation Compensation: Yes | CT: Built-in | Series: K2CU |
K2CU-P Heater Element Burnout Detector, Small-capacity, Plug-in Model. With/without voltage fluctuation compensation.
K2CU-P Heater Element Burnout Detector, Small-capacity, Plug-in Model. With/without voltage fluctuation compensation.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K2CU-P0.5A-A | K2CU-P0.5A 100/200VAC with comp 0.25~0.5 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 0.25~0.5 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P1A-A | K2CU-P1A 100/200VAC with comp 0.5~1 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 0.5~1 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P2A-A | K2CU-P2A 100/200VAC with comp 1~2 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 1~2 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P4A-A | K2CU-P4A 100/200VAC with comp 2~4 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 2~4 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P1-A | K2CU-P1 100/200VAC no comp 0.5~1 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 0.5~1 A | Voltage Fluctuation Compensation: No | Series: K2CU | |
| K2CU-P2-A | K2CU-P2 100/200VAC no comp 1~2 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 1~2 A | Voltage Fluctuation Compensation: No | Series: K2CU | |
| K2CU-P4-A | K2CU-P4 100/200VAC no comp 2~4 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 100/200 VAC | Operating Current: 2~4 A | Voltage Fluctuation Compensation: No | Series: K2CU | |
| K2CU-P0.5A-B | K2CU-P0.5A 110/220VAC with comp 0.25~0.5 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 0.25~0.5 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P1A-B | K2CU-P1A 110/220VAC with comp 0.5~1 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 0.5~1 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P2A-B | K2CU-P2A 110/220VAC with comp 1~2 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 1~2 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P4A-B | K2CU-P4A 110/220VAC with comp 2~4 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 2~4 A | Voltage Fluctuation Compensation: Yes | Series: K2CU | |
| K2CU-P1-B | K2CU-P1 110/220VAC no comp 0.5~1 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 0.5~1 A | Voltage Fluctuation Compensation: No | Series: K2CU | |
| K2CU-P2-B | K2CU-P2 110/220VAC no comp 1~2 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 1~2 A | Voltage Fluctuation Compensation: No | Series: K2CU | |
| K2CU-P4-B | K2CU-P4 110/220VAC no comp 2~4 A | OMRON | Type: Heater Element Burnout Detector | Model: P (Small-capacity Plug-in) | Control Supply Voltage: 110/220 VAC | Operating Current: 2~4 A | Voltage Fluctuation Compensation: No | Series: K2CU |
OMRON K8AK-AS Series single-phase current relay for industrial facilities and equipment. Overcurrent or undercurrent monitoring. Relay output. K8AK-AS1: 2mA~500mA. K8AK-AS2: 0.1A~8A. K8AK-AS3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC.
OMRON K8AK-AS Series single-phase current relay for industrial facilities and equipment. Overcurrent or undercurrent monitoring. Relay output. K8AK-AS1: 2mA~500mA. K8AK-AS2: 0.1A~8A. K8AK-AS3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-AS1 24 VAC/DC | K8AK-AS AS1 24 VAC/DC | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | |
| K8AK-AS1 100-240 VAC | K8AK-AS AS1 100~240 VAC | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | |
| K8AK-AS2 24 VAC/DC | K8AK-AS AS2 24 VAC/DC | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A / 0.8~8A AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8AK-AS2 100-240 VAC | K8AK-AS AS2 100~240 VAC | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A / 0.8~8A AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT compatible | |
| K8AK-AS3 24 VAC/DC | K8AK-AS AS3 24 VAC/DC | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AK-AS3 100-240 VAC | K8AK-AS AS3 100~240 VAC | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AC-CT200L | Current Transformer for K8AK-AS3 10~200A | OMRON | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8AK-AS3 (required, direct input not possible) |
OMRON K8AK-AW Series single-phase relay for simultaneous overcurrent and undercurrent monitoring. K8AK-AW1: 2mA~500mA. K8AK-AW2: 0.1A~5A. K8AK-AW3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Relay output.
OMRON K8AK-AW Series single-phase relay for simultaneous overcurrent and undercurrent monitoring. K8AK-AW1: 2mA~500mA. K8AK-AW2: 0.1A~5A. K8AK-AW3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Relay output.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-AW1 24 VAC/DC | K8AK-AW AW1 24 VAC/DC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8AK-AW1 100-240 VAC | K8AK-AW AW1 100~240 VAC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8AK-AW2 24 VAC/DC | K8AK-AW AW2 24 VAC/DC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8AK-AW2 100-240 VAC | K8AK-AW AW2 100~240 VAC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT compatible | |
| K8AK-AW3 24 VAC/DC | K8AK-AW AW3 24 VAC/DC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AK-AW3 100-240 VAC | K8AK-AW AW3 100~240 VAC | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AC-CT200L | Current Transformer for K8AK-AW3 10~200A | OMRON | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8AK-AW3 (required, direct input not possible) |
Ideal for Liquid Level Control in Industrial Facilities and Equipment.
Ideal for Liquid Level Control in Industrial Facilities and Equipment.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-LS1 24 VAC/DC | K8AK-LS Conductive Level Controller 24VAC/DC | OMRON | Type: Conductive Level Controller | Application: Liquid level control | Power Supply: 24 VAC/DC | Note: Electrode holders/rods sold separately: PS/BF/BS/PH series, F03-60 electrode rods | |
| K8AK-LS1 100-240 VAC | K8AK-LS Conductive Level Controller 100~240VAC | OMRON | Type: Conductive Level Controller | Application: Liquid level control | Power Supply: 100~240 VAC | Note: Electrode holders/rods sold separately: PS/BF/BS/PH series, F03-60 electrode rods |
Ideal for 3-phase Voltage Asymmetry Monitoring for Industrial Facilities and Equipment. 22.5 mm (W). One SPDT output relays
Ideal for 3-phase Voltage Asymmetry Monitoring for Industrial Facilities and Equipment. 22.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-PA1 | K8AK-PA 200~240VAC 3W/4W | OMRON | Type: Three-phase Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input 3W: 200/220/230/240 VAC | Rated Input 4W: 115/127/133/138 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 22.5 mm | |
| K8AK-PA2 | K8AK-PA 380~480VAC 3W/4W | OMRON | Type: Three-phase Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input 3W: 380/400/415/480 VAC | Rated Input 4W: 220/230/240/277 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 22.5 mm |
OMRON K8AK-PH Series three-phase phase-sequence and phase-loss relay. Voltage detection method. 22.5mm width. 3-phase 3-wire 200~480 VAC. DPDT × 1 relay output.
OMRON K8AK-PH Series three-phase phase-sequence and phase-loss relay. Voltage detection method. 22.5mm width. 3-phase 3-wire 200~480 VAC. DPDT × 1 relay output.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-PH1 | K8AK-PH Phase-sequence/Phase-loss 200~480VAC DPDT | OMRON | Type: Three-phase Phase-sequence Phase-loss Relay | Detection Method: Voltage detection | Function: Phase sequence and phase loss monitoring | Rated Input Voltage: 3-phase 3-wire 200~480 VAC | Power Supply: Same as rated input voltage | Output: DPDT × 1 | Width: 22.5 mm |
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 22.5 mm (W). Two SPDT output relays
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 22.5 mm (W). Two SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-PM1 | K8AK-PM 200~240VAC 3W/4W | OMRON | Type: Three-phase Voltage/Phase-sequence/Phase-loss Relay | Rated Input 3W: 200/220/230/240 VAC | Rated Input 4W: 115/127/133/138 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 2 | Width: 22.5 mm | |
| K8AK-PM2 | K8AK-PM 380~480VAC 3W/4W | OMRON | Type: Three-phase Voltage/Phase-sequence/Phase-loss Relay | Rated Input 3W: 380/400/415/480 VAC | Rated Input 4W: 220/230/240/277 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 2 | Width: 22.5 mm |
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 22.5 mm (W). Two SPDT output relays
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 22.5 mm (W). Two SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-PW1 | K8AK-PW 200~240VAC 3W/4W | OMRON | Type: Three-phase Voltage Relay | Rated Input 3W: 200/220/230/240 VAC | Rated Input 4W: 115/127/133/138 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 2 | Width: 22.5 mm | |
| K8AK-PW2 | K8AK-PW 380~480VAC 3W/4W | OMRON | Type: Three-phase Voltage Relay | Rated Input 3W: 380/400/415/480 VAC | Rated Input 4W: 220/230/240/277 VAC | Mode Selection: DIP switch (3-wire or 4-wire + input range) | Power Supply: Same as rated input voltage | Output: SPDT × 2 | Width: 22.5 mm |
Compact and Slim Relay Ideal for Temperature Alarms and Monitoring
Compact and Slim Relay Ideal for Temperature Alarms and Monitoring
| Product Code | Description | Brand | |
|---|---|---|---|
| OMRON-K8AK-TH | [OMRON] — K8AK-TH Temperature Monitoring Relay (Thermocouple/Pt, 0~999°C, 24V/100~240V) | Omron |
Monitor Temperature Rise through Internal Motor Loss
Monitor Temperature Rise through Internal Motor Loss
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-PT1 100-240 VAC | K8AK-PT Phase sequence/loss + temperature 100~240VAC | OMRON | Type: Thermistor Motor Protection Relay | Function: Phase sequence, phase loss, and temperature monitoring | Input: Thermistor (PTC) | Power Supply: 100~240 VAC | |
| K8AK-TS1 100-240 VAC | K8AK-TS Temperature monitoring 100~240VAC | OMRON | Type: Thermistor Motor Protection Relay | Function: Temperature monitoring only | Input: Thermistor (PTC) | Power Supply: 100~240 VAC | |
| K8AK-TS1 24 VAC/DC | K8AK-TS Temperature monitoring 24VAC/DC | OMRON | Type: Thermistor Motor Protection Relay | Function: Temperature monitoring only | Input: Thermistor (PTC) | Power Supply: 24 VAC/DC |
OMRON K8AK-VS Series single-phase voltage relay for industrial facilities. Overvoltage or undervoltage monitoring. Relay output. K8AK-VS2: 1~150V AC/DC (3 ranges). K8AK-VS3: 20~600V AC/DC (3 ranges). Power supply: 24 VAC/DC or 100~240 VAC.
OMRON K8AK-VS Series single-phase voltage relay for industrial facilities. Overvoltage or undervoltage monitoring. Relay output. K8AK-VS2: 1~150V AC/DC (3 ranges). K8AK-VS3: 20~600V AC/DC (3 ranges). Power supply: 24 VAC/DC or 100~240 VAC.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-VS2 24 VAC/DC | K8AK-VS VS2 24 VAC/DC | OMRON | Type: Single-phase Voltage Relay | Setting Range: 1~10V / 3~30V / 15~150V AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overvoltage or Undervoltage selectable | |
| K8AK-VS2 100-240 VAC | K8AK-VS VS2 100~240 VAC | OMRON | Type: Single-phase Voltage Relay | Setting Range: 1~10V / 3~30V / 15~150V AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overvoltage or Undervoltage selectable | |
| K8AK-VS3 24 VAC/DC | K8AK-VS VS3 24 VAC/DC | OMRON | Type: Single-phase Voltage Relay | Setting Range: 20~200V / 30~300V / 60~600V AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overvoltage or Undervoltage selectable | |
| K8AK-VS3 100-240 VAC | K8AK-VS VS3 100~240 VAC | OMRON | Type: Single-phase Voltage Relay | Setting Range: 20~200V / 30~300V / 60~600V AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overvoltage or Undervoltage selectable |
OMRON K8AK-VW Series single-phase relay for simultaneous overvoltage and undervoltage monitoring. K8AK-VW2: 1~150V AC/DC. K8AK-VW3: 20~600V AC/DC. Power supply: 24 VAC/DC or 100~240 VAC. Relay output.
OMRON K8AK-VW Series single-phase relay for simultaneous overvoltage and undervoltage monitoring. K8AK-VW2: 1~150V AC/DC. K8AK-VW3: 20~600V AC/DC. Power supply: 24 VAC/DC or 100~240 VAC. Relay output.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8AK-VW2 24 VAC/DC | K8AK-VW VW2 24 VAC/DC | OMRON | Type: Single-phase Overvoltage/Undervoltage Relay (simultaneous) | Setting Range: 1~10V / 3~30V / 15~150V AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overvoltage AND Undervoltage simultaneous monitoring | |
| K8AK-VW2 100-240 VAC | K8AK-VW VW2 100~240 VAC | OMRON | Type: Single-phase Overvoltage/Undervoltage Relay (simultaneous) | Setting Range: 1~10V / 3~30V / 15~150V AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overvoltage AND Undervoltage simultaneous monitoring | |
| K8AK-VW3 24 VAC/DC | K8AK-VW VW3 24 VAC/DC | OMRON | Type: Single-phase Overvoltage/Undervoltage Relay (simultaneous) | Setting Range: 20~200V / 30~300V / 60~600V AC/DC | Power Supply: 24 VAC/DC | Output: Relay | Mode: Overvoltage AND Undervoltage simultaneous monitoring | |
| K8AK-VW3 100-240 VAC | K8AK-VW VW3 100~240 VAC | OMRON | Type: Single-phase Overvoltage/Undervoltage Relay (simultaneous) | Setting Range: 20~200V / 30~300V / 60~600V AC/DC | Power Supply: 100~240 VAC | Output: Relay | Mode: Overvoltage AND Undervoltage simultaneous monitoring |
Ideal for 3-phase Voltage Asymmetry Monitoring for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
Ideal for 3-phase Voltage Asymmetry Monitoring for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DS-PA1 | K8DS-PA 200~240VAC 3-wire | OMRON | Type: Three-phase Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 200/220/230/240 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm | |
| K8DS-PA2 | K8DS-PA 380~480VAC 3-wire | OMRON | Type: Three-phase Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 380/400/415/480 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm |
Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method. 17.5 mm (W). One SPDT output relays
Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method. 17.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DS-PH1 | K8DS-PH Phase-sequence/Phase-loss 200~480VAC SPDT | OMRON | Type: Three-phase Phase-sequence Phase-loss Relay | Detection Method: Voltage detection | Function: Phase sequence and phase loss monitoring | Rated Input Voltage: 3-phase 3-wire 200~480 VAC | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm |
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DS-PM1 | K8DS-PM 200~240VAC 3-wire | OMRON | Type: Three-phase Voltage/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 200/220/230/240 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm | |
| K8DS-PM2 | K8DS-PM 380~480VAC 3-wire | OMRON | Type: Three-phase Voltage/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 380/400/415/480 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm |
[OMRON] — K8DS-PU Three-phase Undervoltage and Phase-sequence Phase-loss Relay (200~480VAC, 17.5mm)
▶Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DS-PU1 | K8DS-PU 200~240VAC 3-wire | OMRON | Type: Three-phase Undervoltage/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 200/220/230/240 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm | |
| K8DS-PU2 | K8DS-PU 380~480VAC 3-wire | OMRON | Type: Three-phase Undervoltage/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 380/400/415/480 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm |
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
Ideal for Monitoring 3-phase Power Supplies for Industrial Facilities and Equipment. 17.5 mm (W). One SPDT output relays
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DS-PZ1 | K8DS-PZ 200~240VAC 3-wire | OMRON | Type: Three-phase Voltage/Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 200/220/230/240 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm | |
| K8DS-PZ2 | K8DS-PZ 380~480VAC 3-wire | OMRON | Type: Three-phase Voltage/Asymmetry/Phase-sequence/Phase-loss Relay | Rated Input Voltage: 3-phase 3-wire 380/400/415/480 VAC | Input Range Setting: Rotary switch | Power Supply: Same as rated input voltage | Output: SPDT × 1 | Width: 17.5 mm |
OMRON K8DT-AS Series single-phase current relay. Detects motor/equipment errors through current changes. Overcurrent or undercurrent mode selectable. K8DT-AS1: 2mA~500mA. K8DT-AS2: 0.1A~5A (CT available). K8DT-AS3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Output: Relay SPDT or Transistor.
OMRON K8DT-AS Series single-phase current relay. Detects motor/equipment errors through current changes. Overcurrent or undercurrent mode selectable. K8DT-AS1: 2mA~500mA. K8DT-AS2: 0.1A~5A (CT available). K8DT-AS3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Output: Relay SPDT or Transistor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DT-AS1CD | K8DT-AS AS1 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | |
| K8DT-AS1TD | K8DT-AS AS1 24 VAC/DC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | |
| K8DT-AS1CA | K8DT-AS AS1 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | |
| K8DT-AS1TA | K8DT-AS AS1 100~240 VAC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | |
| K8DT-AS2CD | K8DT-AS AS2 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT (0~1A or 0~5A secondary) also compatible | |
| K8DT-AS2TD | K8DT-AS AS2 24 VAC/DC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT (0~1A or 0~5A secondary) also compatible | |
| K8DT-AS2CA | K8DT-AS AS2 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT (0~1A or 0~5A secondary) also compatible | |
| K8DT-AS2TA | K8DT-AS AS2 100~240 VAC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | Note: Commercially available CT (0~1A or 0~5A secondary) also compatible | |
| K8DT-AS3CD | K8DT-AS AS3 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC (CT required) | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AS3TD | K8DT-AS AS3 24 VAC/DC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC (CT required) | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AS3CA | K8DT-AS AS3 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC (CT required) | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AS3TA | K8DT-AS AS3 100~240 VAC Transistor | OMRON | Type: Single-phase Current Relay | Setting Range: 10~100A / 20~200A AC (CT required) | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent or Undercurrent selectable | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AC-CT200L | Current Transformer for K8DT-AS3 10~200A | OMRON | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8DT-AS3 (required, direct input not possible) | Note: Mandatory pair for K8DT-AS3; direct connection without CT is not possible |
OMRON K8DT-AW Series single-phase relay for simultaneous overcurrent and undercurrent monitoring. One relay monitors both conditions at once. K8DT-AW1: 2mA~500mA. K8DT-AW2: 0.1A~5A. K8DT-AW3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Output: Relay SPDT or Transistor.
OMRON K8DT-AW Series single-phase relay for simultaneous overcurrent and undercurrent monitoring. One relay monitors both conditions at once. K8DT-AW1: 2mA~500mA. K8DT-AW2: 0.1A~5A. K8DT-AW3: 10~200A AC (requires K8AC-CT200L CT). Power supply: 24 VAC/DC or 100~240 VAC. Output: Relay SPDT or Transistor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| K8DT-AW1CD | K8DT-AW AW1 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8DT-AW1TD | K8DT-AW AW1 24 VAC/DC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8DT-AW1CA | K8DT-AW AW1 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8DT-AW1TA | K8DT-AW AW1 100~240 VAC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 2~20mA / 10~100mA / 50~500mA AC/DC | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | |
| K8DT-AW2CD | K8DT-AW AW2 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8DT-AW2TD | K8DT-AW AW2 24 VAC/DC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8DT-AW2CA | K8DT-AW AW2 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8DT-AW2TA | K8DT-AW AW2 100~240 VAC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 0.1~1A / 0.5~5A AC/DC | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Commercially available CT (0~1A or 0~5A) compatible | |
| K8DT-AW3CD | K8DT-AW AW3 24 VAC/DC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AW3TD | K8DT-AW AW3 24 VAC/DC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 24 VAC/DC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AW3CA | K8DT-AW AW3 100~240 VAC Relay SPDT | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Relay SPDT | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8DT-AW3TA | K8DT-AW AW3 100~240 VAC Transistor | OMRON | Type: Single-phase Overcurrent/Undercurrent Relay (simultaneous) | Setting Range: 10~100A / 20~200A AC | Power Supply: 100~240 VAC | Output: Transistor | Mode: Overcurrent AND Undercurrent simultaneous monitoring | Note: Requires K8AC-CT200L CT (included in this family) | |
| K8AC-CT200L | Current Transformer for K8DT-AW3 10~200A | OMRON | Type: Current Transformer (CT) | Input Range: 10~100A AC / 20~200A AC | Compatible Relay: K8DT-AW3 (required, direct input not possible) |