Magnetic Starters
Mitsubishi Electric MS-T/N series N220-frame reversing open-type magnetic starter MSOD-2xN220: DC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series N220-frame reversing open-type magnetic starter MSOD-2xN220: DC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN220 82A DC12V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC24V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC48V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC100V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC110V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC125V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC200V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 82A DC220V | MSOD-2xN220 reversing starter, N220 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC12V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC24V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC48V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC100V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC110V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC125V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC200V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 105A DC220V | MSOD-2xN220 reversing starter, N220 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC12V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC24V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC48V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC100V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC110V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC125V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC200V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 125A DC220V | MSOD-2xN220 reversing starter, N220 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC12V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC24V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC48V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC100V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC110V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC125V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC200V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 150A DC220V | MSOD-2xN220 reversing starter, N220 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC12V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC24V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC48V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC100V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC110V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC125V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC200V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN220 180A DC220V | MSOD-2xN220 reversing starter, N220 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N300-frame reversing open-type magnetic starter MSOD-2xN300: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series N300-frame reversing open-type magnetic starter MSOD-2xN300: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN300 105A DC12V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC24V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC48V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC100V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC110V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC125V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC200V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 105A DC220V | MSOD-2xN300 reversing starter, N300 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC12V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC24V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC48V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC100V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC110V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC125V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC200V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 125A DC220V | MSOD-2xN300 reversing starter, N300 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC12V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC24V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC48V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC100V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC110V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC125V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC200V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 150A DC220V | MSOD-2xN300 reversing starter, N300 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC12V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC24V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC48V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC100V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC110V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC125V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC200V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 180A DC220V | MSOD-2xN300 reversing starter, N300 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC12V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC24V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC48V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC100V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC110V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC125V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC200V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN300 250A DC220V | MSOD-2xN300 reversing starter, N300 frame, 250A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N400-frame reversing open-type magnetic starter MSOD-2xN400: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series N400-frame reversing open-type magnetic starter MSOD-2xN400: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xN400 105A DC12V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC24V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC48V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC100V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC110V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC125V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC200V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 105A DC220V | MSOD-2xN400 reversing starter, N400 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC12V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC24V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC48V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC100V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC110V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC125V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC200V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 125A DC220V | MSOD-2xN400 reversing starter, N400 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC12V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC24V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC48V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC100V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC110V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC125V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC200V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 150A DC220V | MSOD-2xN400 reversing starter, N400 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC12V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC24V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC48V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC100V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC110V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC125V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC200V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 180A DC220V | MSOD-2xN400 reversing starter, N400 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC12V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC24V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC48V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC100V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC110V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC125V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC200V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 250A DC220V | MSOD-2xN400 reversing starter, N400 frame, 250A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC12V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC24V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC48V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC100V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC110V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC125V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC200V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xN400 330A DC220V | MSOD-2xN400 reversing starter, N400 frame, 330A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 3a3b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T100-frame reversing open-type magnetic starter MSOD-2xT100: DC-operated contactor combined with TH-T65/T100 2-element thermal overload relay (manual reset standard). Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T100-frame reversing open-type magnetic starter MSOD-2xT100: DC-operated contactor combined with TH-T65/T100 2-element thermal overload relay (manual reset standard). Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT100 15A DC12V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC24V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC48V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC100V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC110V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC125V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC200V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 15A DC220V | MSOD-2xT100 reversing starter, T100 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC12V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC24V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC48V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC100V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC110V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC125V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC200V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 22A DC220V | MSOD-2xT100 reversing starter, T100 frame, 22A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC12V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC24V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC48V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC100V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC110V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC125V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC200V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 29A DC220V | MSOD-2xT100 reversing starter, T100 frame, 29A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC12V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC24V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC48V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC100V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC110V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC125V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC200V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 35A DC220V | MSOD-2xT100 reversing starter, T100 frame, 35A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC12V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC24V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC48V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC100V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC110V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC125V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC200V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 42A DC220V | MSOD-2xT100 reversing starter, T100 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC12V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC24V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC48V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC100V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC110V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC125V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC200V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 54A DC220V | MSOD-2xT100 reversing starter, T100 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC12V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC24V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC48V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC100V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC110V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC125V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC200V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 67A DC220V | MSOD-2xT100 reversing starter, T100 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC12V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC24V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC48V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC100V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC110V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC125V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC200V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT100 82A DC220V | MSOD-2xT100 reversing starter, T100 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T12-frame reversing open-type magnetic starter MSOD-2xT12: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T12-frame reversing open-type magnetic starter MSOD-2xT12: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT12 0.12A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.12A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.12A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.17A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.17A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.24A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.35A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.5A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.7A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC12V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC24V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC48V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC100V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC110V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC125V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC200V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 0.9A DC220V | MSOD-2xT12 reversing starter, T12 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC12V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC24V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC48V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC100V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC110V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC125V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC200V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.3A DC220V | MSOD-2xT12 reversing starter, T12 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC12V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC24V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC48V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC100V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC110V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC125V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC200V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 1.7A DC220V | MSOD-2xT12 reversing starter, T12 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC12V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC24V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC48V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC100V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC110V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC125V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC200V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.1A DC220V | MSOD-2xT12 reversing starter, T12 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC12V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC24V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC48V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC100V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC110V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC125V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC200V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 2.5A DC220V | MSOD-2xT12 reversing starter, T12 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC12V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC24V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC48V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC100V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC110V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC125V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC200V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 3.6A DC220V | MSOD-2xT12 reversing starter, T12 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC12V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC24V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC48V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC100V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC110V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC125V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC200V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 5A DC220V | MSOD-2xT12 reversing starter, T12 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC12V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC24V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC48V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC100V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC110V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC125V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC200V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 6.6A DC220V | MSOD-2xT12 reversing starter, T12 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC12V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC24V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC48V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC100V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC110V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC125V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC200V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 9A DC220V | MSOD-2xT12 reversing starter, T12 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC12V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC24V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC48V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC100V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC110V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC125V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC200V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT12 11A DC220V | MSOD-2xT12 reversing starter, T12 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T20-frame reversing open-type magnetic starter MSOD-2xT20: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T20-frame reversing open-type magnetic starter MSOD-2xT20: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT20 0.12A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.12A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.12A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.17A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.17A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.24A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.35A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.5A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.7A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC12V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC24V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC48V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC100V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC110V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC125V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC200V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 0.9A DC220V | MSOD-2xT20 reversing starter, T20 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC12V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC24V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC48V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC100V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC110V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC125V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC200V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.3A DC220V | MSOD-2xT20 reversing starter, T20 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC12V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC24V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC48V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC100V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC110V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC125V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC200V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 1.7A DC220V | MSOD-2xT20 reversing starter, T20 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC12V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC24V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC48V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC100V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC110V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC125V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC200V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.1A DC220V | MSOD-2xT20 reversing starter, T20 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC12V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC24V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC48V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC100V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC110V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC125V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC200V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 2.5A DC220V | MSOD-2xT20 reversing starter, T20 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC12V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC24V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC48V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC100V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC110V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC125V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC200V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 3.6A DC220V | MSOD-2xT20 reversing starter, T20 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC12V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC24V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC48V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC100V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC110V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC125V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC200V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 5A DC220V | MSOD-2xT20 reversing starter, T20 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC12V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC24V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC48V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC100V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC110V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC125V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC200V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 6.6A DC220V | MSOD-2xT20 reversing starter, T20 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC12V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC24V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC48V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC100V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC110V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC125V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC200V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 9A DC220V | MSOD-2xT20 reversing starter, T20 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC12V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC24V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC48V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC100V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC110V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC125V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC200V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 11A DC220V | MSOD-2xT20 reversing starter, T20 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC12V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC24V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC48V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC100V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC110V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC125V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC200V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT20 15A DC220V | MSOD-2xT20 reversing starter, T20 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b x2 + 2b (interlock unit b-contact) · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T21-frame reversing open-type magnetic starter MSOD-2xT21: DC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T21-frame reversing open-type magnetic starter MSOD-2xT21: DC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT21 0.24A DC12V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC24V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC48V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC100V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC110V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC125V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC200V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.24A DC220V | MSOD-2xT21 reversing starter, T21 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC12V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC24V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC48V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC100V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC110V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC125V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC200V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.35A DC220V | MSOD-2xT21 reversing starter, T21 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC12V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC24V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC48V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC100V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC110V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC125V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC200V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.5A DC220V | MSOD-2xT21 reversing starter, T21 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC12V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC24V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC48V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC100V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC110V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC125V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC200V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.7A DC220V | MSOD-2xT21 reversing starter, T21 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC12V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC24V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC48V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC100V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC110V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC125V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC200V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 0.9A DC220V | MSOD-2xT21 reversing starter, T21 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC12V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC24V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC48V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC100V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC110V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC125V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC200V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.3A DC220V | MSOD-2xT21 reversing starter, T21 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC12V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC24V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC48V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC100V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC110V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC125V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC200V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 1.7A DC220V | MSOD-2xT21 reversing starter, T21 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC12V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC24V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC48V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC100V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC110V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC125V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC200V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.1A DC220V | MSOD-2xT21 reversing starter, T21 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC12V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC24V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC48V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC100V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC110V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC125V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC200V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 2.5A DC220V | MSOD-2xT21 reversing starter, T21 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC12V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC24V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC48V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC100V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC110V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC125V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC200V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 3.6A DC220V | MSOD-2xT21 reversing starter, T21 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC12V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC24V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC48V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC100V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC110V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC125V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC200V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 5A DC220V | MSOD-2xT21 reversing starter, T21 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC12V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC24V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC48V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC100V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC110V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC125V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC200V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 6.6A DC220V | MSOD-2xT21 reversing starter, T21 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC12V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC24V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC48V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC100V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC110V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC125V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC200V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 9A DC220V | MSOD-2xT21 reversing starter, T21 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC12V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC24V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC48V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC100V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC110V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC125V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC200V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 11A DC220V | MSOD-2xT21 reversing starter, T21 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC12V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC24V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC48V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC100V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC110V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC125V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC200V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT21 15A DC220V | MSOD-2xT21 reversing starter, T21 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T35-frame reversing open-type magnetic starter MSOD-2xT35: DC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T35-frame reversing open-type magnetic starter MSOD-2xT35: DC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 7.5kW / 34A (AC-3) at 200-220V and 15kW / 32A at 380-440V, Ith 60A. Heater designations 0.24A to 29A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT35 0.24A DC12V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC24V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC48V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC100V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC110V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC125V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC200V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.24A DC220V | MSOD-2xT35 reversing starter, T35 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC12V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC24V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC48V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC100V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC110V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC125V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC200V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.35A DC220V | MSOD-2xT35 reversing starter, T35 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC12V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC24V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC48V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC100V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC110V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC125V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC200V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.5A DC220V | MSOD-2xT35 reversing starter, T35 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC12V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC24V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC48V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC100V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC110V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC125V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC200V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.7A DC220V | MSOD-2xT35 reversing starter, T35 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC12V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC24V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC48V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC100V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC110V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC125V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC200V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 0.9A DC220V | MSOD-2xT35 reversing starter, T35 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC12V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC24V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC48V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC100V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC110V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC125V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC200V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.3A DC220V | MSOD-2xT35 reversing starter, T35 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC12V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC24V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC48V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC100V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC110V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC125V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC200V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 1.7A DC220V | MSOD-2xT35 reversing starter, T35 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC12V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC24V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC48V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC100V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC110V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC125V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC200V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.1A DC220V | MSOD-2xT35 reversing starter, T35 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC12V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC24V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC48V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC100V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC110V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC125V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC200V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 2.5A DC220V | MSOD-2xT35 reversing starter, T35 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC12V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC24V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC48V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC100V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC110V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC125V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC200V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 3.6A DC220V | MSOD-2xT35 reversing starter, T35 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC12V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC24V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC48V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC100V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC110V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC125V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC200V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 5A DC220V | MSOD-2xT35 reversing starter, T35 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC12V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC24V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC48V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC100V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC110V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC125V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC200V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 6.6A DC220V | MSOD-2xT35 reversing starter, T35 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC12V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC24V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC48V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC100V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC110V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC125V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC200V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 9A DC220V | MSOD-2xT35 reversing starter, T35 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC12V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC24V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC48V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC100V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC110V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC125V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC200V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 11A DC220V | MSOD-2xT35 reversing starter, T35 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC12V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC24V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC48V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC100V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC110V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC125V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC200V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 15A DC220V | MSOD-2xT35 reversing starter, T35 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC12V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC24V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC48V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC100V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC110V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC125V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC200V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 22A DC220V | MSOD-2xT35 reversing starter, T35 frame, 22A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC12V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC12V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC24V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC24V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC48V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC48V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC100V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC100V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC110V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC110V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC125V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC125V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC200V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC200V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT35 29A DC220V | MSOD-2xT35 reversing starter, T35 frame, 29A heater, DC220V coil | Mitsubishi Electric | Frame: T35 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 7.5kW@200-220V / 15kW@380-440V / 15kW@500-550V · AC-3 Current: 34A@200-220V / 32A@380-440V / 26A@500-550V · AC-1 Current: 60A@200-220V / 60A@380-440V · Thermal Current Ith: 60A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T50-frame reversing open-type magnetic starter MSOD-2xT50: DC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T50-frame reversing open-type magnetic starter MSOD-2xT50: DC-operated contactor combined with TH-T25/T50 2-element thermal overload relay (manual reset standard). Rated 11kW / 50A (AC-3) at 200-220V and 22kW / 48A at 380-440V, Ith 80A. Heater designations 0.24A to 42A (19 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT50 0.24A DC12V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC24V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC48V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC100V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC110V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC125V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC200V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.24A DC220V | MSOD-2xT50 reversing starter, T50 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC12V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC24V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC48V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC100V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC110V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC125V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC200V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.35A DC220V | MSOD-2xT50 reversing starter, T50 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC12V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC24V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC48V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC100V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC110V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC125V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC200V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.5A DC220V | MSOD-2xT50 reversing starter, T50 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC12V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC24V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC48V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC100V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC110V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC125V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC200V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.7A DC220V | MSOD-2xT50 reversing starter, T50 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC12V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC24V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC48V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC100V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC110V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC125V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC200V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 0.9A DC220V | MSOD-2xT50 reversing starter, T50 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC12V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC24V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC48V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC100V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC110V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC125V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC200V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.3A DC220V | MSOD-2xT50 reversing starter, T50 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC12V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC24V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC48V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC100V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC110V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC125V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC200V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 1.7A DC220V | MSOD-2xT50 reversing starter, T50 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC12V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC24V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC48V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC100V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC110V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC125V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC200V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.1A DC220V | MSOD-2xT50 reversing starter, T50 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC12V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC24V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC48V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC100V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC110V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC125V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC200V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 2.5A DC220V | MSOD-2xT50 reversing starter, T50 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC12V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC24V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC48V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC100V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC110V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC125V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC200V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 3.6A DC220V | MSOD-2xT50 reversing starter, T50 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC12V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC24V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC48V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC100V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC110V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC125V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC200V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 5A DC220V | MSOD-2xT50 reversing starter, T50 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC12V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC24V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC48V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC100V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC110V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC125V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC200V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 6.6A DC220V | MSOD-2xT50 reversing starter, T50 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC12V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC24V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC48V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC100V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC110V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC125V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC200V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 9A DC220V | MSOD-2xT50 reversing starter, T50 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC12V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC24V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC48V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC100V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC110V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC125V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC200V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 11A DC220V | MSOD-2xT50 reversing starter, T50 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC12V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC24V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC48V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC100V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC110V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC125V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC200V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 15A DC220V | MSOD-2xT50 reversing starter, T50 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC12V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC24V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC48V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC100V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC110V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC125V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC200V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 22A DC220V | MSOD-2xT50 reversing starter, T50 frame, 22A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC12V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC24V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC48V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC100V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC110V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC125V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC200V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 29A DC220V | MSOD-2xT50 reversing starter, T50 frame, 29A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC12V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC24V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC48V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC100V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC110V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC125V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC200V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 35A DC220V | MSOD-2xT50 reversing starter, T50 frame, 35A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC12V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC24V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC48V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC100V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC110V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC125V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC200V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT50 42A DC220V | MSOD-2xT50 reversing starter, T50 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: T50 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T50 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 11kW@200-220V / 22kW@380-440V / 22kW@500-550V · AC-3 Current: 50A@200-220V / 48A@380-440V / 38A@500-550V · AC-1 Current: 80A@200-220V / 80A@380-440V · Thermal Current Ith: 80A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T65-frame reversing open-type magnetic starter MSOD-2xT65: DC-operated contactor combined with TH-T65 2-element thermal overload relay (manual reset standard). Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T65-frame reversing open-type magnetic starter MSOD-2xT65: DC-operated contactor combined with TH-T65 2-element thermal overload relay (manual reset standard). Rated 15kW / 65A (AC-3) at 200-220V and 30kW / 65A at 380-440V, Ith 100A. Heater designations 15A to 54A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT65 15A DC12V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC24V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC48V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC100V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC110V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC125V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC200V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 15A DC220V | MSOD-2xT65 reversing starter, T65 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC12V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC24V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC48V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC100V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC110V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC125V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC200V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 22A DC220V | MSOD-2xT65 reversing starter, T65 frame, 22A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC12V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC24V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC48V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC100V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC110V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC125V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC200V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 29A DC220V | MSOD-2xT65 reversing starter, T65 frame, 29A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC12V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC24V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC48V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC100V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC110V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC125V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC200V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 35A DC220V | MSOD-2xT65 reversing starter, T65 frame, 35A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC12V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC24V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC48V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC100V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC110V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC125V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC200V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 42A DC220V | MSOD-2xT65 reversing starter, T65 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC12V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC24V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC48V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC100V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC110V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC125V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC200V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT65 54A DC220V | MSOD-2xT65 reversing starter, T65 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: T65 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 15kW@200-220V / 30kW@380-440V / 30kW@500-550V · AC-3 Current: 65A@200-220V / 65A@380-440V / 45A@500-550V · AC-1 Current: 100A@200-220V / 100A@380-440V · Thermal Current Ith: 100A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T80-frame reversing open-type magnetic starter MSOD-2xT80: DC-operated contactor combined with TH-T100 2-element thermal overload relay (manual reset standard). Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
Mitsubishi Electric MS-T/N series T80-frame reversing open-type magnetic starter MSOD-2xT80: DC-operated contactor combined with TH-T100 2-element thermal overload relay (manual reset standard). Rated 19kW / 80A (AC-3) at 200-220V and 37kW / 80A at 380-440V, Ith 120A. Heater designations 67A to 67A (1 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability. Mechanical interlock fitted as standard for forward/reverse motor switching.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-2xT80 67A DC12V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC24V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC48V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC100V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC110V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC125V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC200V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-2xT80 67A DC220V | MSOD-2xT80 reversing starter, T80 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: T80 · Type: Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 19kW@200-220V / 37kW@380-440V / 45kW@500-550V · AC-3 Current: 80A@200-220V / 80A@380-440V / 75A@500-550V · AC-1 Current: 120A@200-220V / 120A@380-440V · Thermal Current Ith: 120A · Aux Contact: 2a2b x2 · Interlock: Mechanical, built-in · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N125-frame non-reversing open-type magnetic starter MSOD-N125: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series N125-frame non-reversing open-type magnetic starter MSOD-N125: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 30kW / 125A (AC-3) at 200-220V and 60kW / 120A at 380-440V, Ith 150A. Heater designations 42A to 105A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-N125 42A DC12V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC24V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC48V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC100V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC110V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC125V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC200V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 42A DC220V | MSOD-N125 non-reversing starter, N125 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC12V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC24V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC48V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC100V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC110V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC125V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC200V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 54A DC220V | MSOD-N125 non-reversing starter, N125 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC12V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC24V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC48V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC100V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC110V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC125V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC200V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 67A DC220V | MSOD-N125 non-reversing starter, N125 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC12V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC24V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC48V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC100V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC110V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC125V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC200V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 82A DC220V | MSOD-N125 non-reversing starter, N125 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC12V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC24V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC48V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC100V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC110V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC125V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC200V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N125 105A DC220V | MSOD-N125 non-reversing starter, N125 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N125 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 30kW@200-220V / 60kW@380-440V / 60kW@500-550V · AC-3 Current: 125A@200-220V / 120A@380-440V / 90A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N150-frame non-reversing open-type magnetic starter MSOD-N150: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series N150-frame non-reversing open-type magnetic starter MSOD-N150: DC-operated contactor combined with TH-N120(TA) 2-element thermal overload relay (manual reset standard). Rated 37kW / 150A (AC-3) at 200-220V and 75kW / 150A at 380-440V, Ith 200A. Heater designations 42A to 125A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-N150 42A DC12V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC24V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC48V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC100V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC110V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC125V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC200V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 42A DC220V | MSOD-N150 non-reversing starter, N150 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC12V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC24V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC48V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC100V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC110V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC125V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC200V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 54A DC220V | MSOD-N150 non-reversing starter, N150 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC12V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC24V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC48V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC100V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC110V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC125V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC200V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 67A DC220V | MSOD-N150 non-reversing starter, N150 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC12V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC24V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC48V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC100V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC110V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC125V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC200V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 82A DC220V | MSOD-N150 non-reversing starter, N150 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC12V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC24V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC48V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC100V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC110V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC125V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC200V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 105A DC220V | MSOD-N150 non-reversing starter, N150 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC12V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC24V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC48V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC100V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC110V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC125V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC200V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N150 125A DC220V | MSOD-N150 non-reversing starter, N150 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N150 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N120TA (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 37kW@200-220V / 75kW@380-440V / 90kW@500-550V · AC-3 Current: 150A@200-220V / 150A@380-440V / 140A@500-550V · AC-1 Current: 200A@200-220V / 200A@380-440V · Thermal Current Ith: 200A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N220-frame non-reversing open-type magnetic starter MSOD-N220: DC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series N220-frame non-reversing open-type magnetic starter MSOD-N220: DC-operated contactor combined with TH-N220RH 2-element thermal overload relay (manual reset standard). Rated 55kW / 220A (AC-3) at 200-220V and 110kW / 220A at 380-440V, Ith 260A. Heater designations 82A to 180A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-N220 82A DC12V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC24V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC48V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC100V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC110V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC125V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC200V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 82A DC220V | MSOD-N220 non-reversing starter, N220 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC12V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC24V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC48V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC100V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC110V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC125V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC200V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 105A DC220V | MSOD-N220 non-reversing starter, N220 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC12V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC24V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC48V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC100V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC110V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC125V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC200V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 125A DC220V | MSOD-N220 non-reversing starter, N220 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC12V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC24V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC48V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC100V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC110V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC125V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC200V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 150A DC220V | MSOD-N220 non-reversing starter, N220 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC12V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC24V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC48V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC100V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC110V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC125V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC200V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N220 180A DC220V | MSOD-N220 non-reversing starter, N220 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N220 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N220RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 55kW@200-220V / 110kW@380-440V / 132kW@500-550V · AC-3 Current: 220A@200-220V / 220A@380-440V / 200A@500-550V · AC-1 Current: 260A@200-220V / 260A@380-440V · Thermal Current Ith: 260A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N300-frame non-reversing open-type magnetic starter MSOD-N300: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series N300-frame non-reversing open-type magnetic starter MSOD-N300: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 75kW / 300A (AC-3) at 200-220V and 150kW / 300A at 380-440V, Ith 350A. Heater designations 105A to 250A (5 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-N300 105A DC12V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC24V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC48V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC100V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC110V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC125V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC200V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 105A DC220V | MSOD-N300 non-reversing starter, N300 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC12V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC24V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC48V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC100V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC110V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC125V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC200V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 125A DC220V | MSOD-N300 non-reversing starter, N300 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC12V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC24V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC48V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC100V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC110V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC125V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC200V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 150A DC220V | MSOD-N300 non-reversing starter, N300 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC12V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC24V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC48V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC100V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC110V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC125V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC200V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 180A DC220V | MSOD-N300 non-reversing starter, N300 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC12V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC12V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC24V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC24V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC48V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC48V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC100V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC100V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC110V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC110V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC125V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC125V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC200V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC200V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N300 250A DC220V | MSOD-N300 non-reversing starter, N300 frame, 250A heater, DC220V coil | Mitsubishi Electric | Frame: N300 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 75kW@200-220V / 150kW@380-440V / 160kW@500-550V · AC-3 Current: 300A@200-220V / 300A@380-440V / 250A@500-550V · AC-1 Current: 350A@200-220V / 350A@380-440V · Thermal Current Ith: 350A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series N400-frame non-reversing open-type magnetic starter MSOD-N400: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series N400-frame non-reversing open-type magnetic starter MSOD-N400: DC-operated contactor combined with TH-N400RH 2-element thermal overload relay (manual reset standard). Rated 110kW / 400A (AC-3) at 200-220V and 200kW / 400A at 380-440V, Ith 450A. Heater designations 105A to 330A (6 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-N400 105A DC12V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC24V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC48V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC100V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC110V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC125V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC200V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 105A DC220V | MSOD-N400 non-reversing starter, N400 frame, 105A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 105A (adjustable 85-125A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC12V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC24V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC48V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC100V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC110V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC125V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC200V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 125A DC220V | MSOD-N400 non-reversing starter, N400 frame, 125A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 125A (adjustable 100-150A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC12V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC24V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC48V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC100V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC110V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC125V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC200V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 150A DC220V | MSOD-N400 non-reversing starter, N400 frame, 150A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 150A (adjustable 120-180A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC12V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC24V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC48V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC100V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC110V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC125V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC200V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 180A DC220V | MSOD-N400 non-reversing starter, N400 frame, 180A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 180A (adjustable 140-220A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC12V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC24V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC48V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC100V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC110V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC125V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC200V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 250A DC220V | MSOD-N400 non-reversing starter, N400 frame, 250A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 250A (adjustable 200-300A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC12V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC12V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC24V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC24V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC48V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC48V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC100V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC100V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC110V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC110V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC125V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC125V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC200V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC200V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-N400 330A DC220V | MSOD-N400 non-reversing starter, N400 frame, 330A heater, DC220V coil | Mitsubishi Electric | Frame: N400 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-N400RH (2-element, manual reset) · Heater: 330A (adjustable 260-400A) · AC-3 Capacity: 110kW@200-220V / 200kW@380-440V / 200kW@500-550V · AC-3 Current: 400A@200-220V / 400A@380-440V / 350A@500-550V · AC-1 Current: 450A@200-220V / 450A@380-440V · Thermal Current Ith: 450A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T100-frame non-reversing open-type magnetic starter MSOD-T100: DC-operated contactor combined with TH-T65/T100 2-element thermal overload relay (manual reset standard). Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T100-frame non-reversing open-type magnetic starter MSOD-T100: DC-operated contactor combined with TH-T65/T100 2-element thermal overload relay (manual reset standard). Rated 22kW / 100A (AC-3) at 200-220V and 45kW / 93A at 380-440V, Ith 150A. Heater designations 15A to 82A (8 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-T100 15A DC12V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC24V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC48V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC100V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC110V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC125V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC200V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 15A DC220V | MSOD-T100 non-reversing starter, T100 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC12V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC24V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC48V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC100V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC110V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC125V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC200V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 22A DC220V | MSOD-T100 non-reversing starter, T100 frame, 22A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 22A (adjustable 18-26A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC12V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC24V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC48V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC100V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC110V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC125V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC200V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 29A DC220V | MSOD-T100 non-reversing starter, T100 frame, 29A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 29A (adjustable 24-34A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC12V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC24V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC48V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC100V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC110V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC125V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC200V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 35A DC220V | MSOD-T100 non-reversing starter, T100 frame, 35A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 35A (adjustable 30-40A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC12V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC24V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC48V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC100V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC110V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC125V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC200V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 42A DC220V | MSOD-T100 non-reversing starter, T100 frame, 42A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 42A (adjustable 34-50A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC12V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC24V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC48V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC100V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC110V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC125V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC200V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 54A DC220V | MSOD-T100 non-reversing starter, T100 frame, 54A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T65 (2-element, manual reset) · Heater: 54A (adjustable 43-65A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC12V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC24V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC48V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC100V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC110V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC125V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC200V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 67A DC220V | MSOD-T100 non-reversing starter, T100 frame, 67A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 67A (adjustable 54-80A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC12V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC12V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC24V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC24V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC48V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC48V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC100V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC100V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC110V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC110V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC125V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC125V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC200V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC200V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T100 82A DC220V | MSOD-T100 non-reversing starter, T100 frame, 82A heater, DC220V coil | Mitsubishi Electric | Frame: T100 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T100 (2-element, manual reset) · Heater: 82A (adjustable 65-100A) · AC-3 Capacity: 22kW@200-220V / 45kW@380-440V / 45kW@500-550V · AC-3 Current: 100A@200-220V / 93A@380-440V / 75A@500-550V · AC-1 Current: 150A@200-220V / 150A@380-440V · Thermal Current Ith: 150A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSOD-T12: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T12-frame non-reversing open-type magnetic starter MSOD-T12: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 2.7kW / 13A (AC-3) at 200-220V and 4kW / 9A at 380-440V, Ith 20A. Heater designations 0.12A to 11A (16 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-T12 0.12A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.12A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.12A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.17A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.17A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.24A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.35A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.5A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.7A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC12V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC24V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC48V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC100V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC110V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC125V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC200V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 0.9A DC220V | MSOD-T12 non-reversing starter, T12 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC12V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC24V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC48V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC100V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC110V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC125V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC200V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.3A DC220V | MSOD-T12 non-reversing starter, T12 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC12V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC24V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC48V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC100V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC110V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC125V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC200V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 1.7A DC220V | MSOD-T12 non-reversing starter, T12 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC12V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC24V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC48V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC100V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC110V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC125V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC200V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.1A DC220V | MSOD-T12 non-reversing starter, T12 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC12V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC24V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC48V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC100V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC110V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC125V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC200V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 2.5A DC220V | MSOD-T12 non-reversing starter, T12 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC12V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC24V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC48V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC100V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC110V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC125V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC200V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 3.6A DC220V | MSOD-T12 non-reversing starter, T12 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC12V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC24V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC48V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC100V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC110V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC125V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC200V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 5A DC220V | MSOD-T12 non-reversing starter, T12 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC12V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC24V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC48V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC100V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC110V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC125V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC200V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 6.6A DC220V | MSOD-T12 non-reversing starter, T12 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC12V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC24V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC48V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC100V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC110V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC125V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC200V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 9A DC220V | MSOD-T12 non-reversing starter, T12 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC12V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC24V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC48V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC100V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC110V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC125V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC200V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T12 11A DC220V | MSOD-T12 non-reversing starter, T12 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T12 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 2.7kW@200-220V / 4kW@380-440V / 5.5kW@500-550V · AC-3 Current: 13A@200-220V / 9A@380-440V / 9A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSOD-T20: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T20-frame non-reversing open-type magnetic starter MSOD-T20: DC-operated contactor combined with TH-T18 2-element thermal overload relay (manual reset standard). Rated 3.7kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 20A. Heater designations 0.12A to 15A (17 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-T20 0.12A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.12A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.12A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.12A (adjustable 0.1-0.16A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.17A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.17A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.17A (adjustable 0.14-0.22A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.24A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.35A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.5A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.7A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC12V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC24V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC48V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC100V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC110V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC125V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC200V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 0.9A DC220V | MSOD-T20 non-reversing starter, T20 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC12V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC24V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC48V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC100V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC110V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC125V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC200V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.3A DC220V | MSOD-T20 non-reversing starter, T20 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC12V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC24V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC48V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC100V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC110V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC125V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC200V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 1.7A DC220V | MSOD-T20 non-reversing starter, T20 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC12V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC24V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC48V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC100V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC110V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC125V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC200V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.1A DC220V | MSOD-T20 non-reversing starter, T20 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC12V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC24V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC48V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC100V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC110V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC125V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC200V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 2.5A DC220V | MSOD-T20 non-reversing starter, T20 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC12V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC24V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC48V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC100V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC110V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC125V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC200V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 3.6A DC220V | MSOD-T20 non-reversing starter, T20 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC12V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC24V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC48V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC100V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC110V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC125V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC200V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 5A DC220V | MSOD-T20 non-reversing starter, T20 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC12V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC24V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC48V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC100V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC110V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC125V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC200V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 6.6A DC220V | MSOD-T20 non-reversing starter, T20 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC12V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC24V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC48V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC100V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC110V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC125V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC200V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 9A DC220V | MSOD-T20 non-reversing starter, T20 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC12V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC24V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC48V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC100V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC110V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC125V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC200V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 11A DC220V | MSOD-T20 non-reversing starter, T20 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC12V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC24V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC48V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC100V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC110V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC125V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC200V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T20 15A DC220V | MSOD-T20 non-reversing starter, T20 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T20 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T18 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 3.7kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 20A@200-220V / 13A@380-440V · Thermal Current Ith: 20A · Aux Contact: 1a1b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |
Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSOD-T21: DC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
Mitsubishi Electric MS-T/N series T21-frame non-reversing open-type magnetic starter MSOD-T21: DC-operated contactor combined with TH-T25 2-element thermal overload relay (manual reset standard). Rated 4kW / 18A (AC-3) at 200-220V and 7.5kW / 18A at 380-440V, Ith 32A. Heater designations 0.24A to 15A (15 steps) for overload and open-phase protection matching. Compliant with JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4; twin auxiliary contacts for high contact reliability.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSOD-T21 0.24A DC12V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC24V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC48V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC100V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC110V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC125V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC200V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.24A DC220V | MSOD-T21 non-reversing starter, T21 frame, 0.24A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.24A (adjustable 0.2-0.32A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC12V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC24V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC48V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC100V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC110V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC125V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC200V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.35A DC220V | MSOD-T21 non-reversing starter, T21 frame, 0.35A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.35A (adjustable 0.28-0.42A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC12V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC24V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC48V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC100V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC110V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC125V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC200V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.5A DC220V | MSOD-T21 non-reversing starter, T21 frame, 0.5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.5A (adjustable 0.4-0.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC12V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC24V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC48V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC100V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC110V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC125V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC200V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.7A DC220V | MSOD-T21 non-reversing starter, T21 frame, 0.7A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.7A (adjustable 0.55-0.85A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC12V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC24V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC48V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC100V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC110V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC125V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC200V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 0.9A DC220V | MSOD-T21 non-reversing starter, T21 frame, 0.9A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 0.9A (adjustable 0.7-1.1A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC12V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC24V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC48V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC100V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC110V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC125V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC200V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.3A DC220V | MSOD-T21 non-reversing starter, T21 frame, 1.3A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.3A (adjustable 1-1.6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC12V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC24V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC48V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC100V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC110V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC125V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC200V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 1.7A DC220V | MSOD-T21 non-reversing starter, T21 frame, 1.7A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 1.7A (adjustable 1.4-2A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC12V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC24V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC48V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC100V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC110V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC125V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC200V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.1A DC220V | MSOD-T21 non-reversing starter, T21 frame, 2.1A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.1A (adjustable 1.7-2.5A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC12V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC24V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC48V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC100V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC110V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC125V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC200V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 2.5A DC220V | MSOD-T21 non-reversing starter, T21 frame, 2.5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 2.5A (adjustable 2-3A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC12V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC24V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC48V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC100V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC110V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC125V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC200V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 3.6A DC220V | MSOD-T21 non-reversing starter, T21 frame, 3.6A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 3.6A (adjustable 2.8-4.4A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC12V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC24V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC48V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC100V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC110V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC125V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC200V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 5A DC220V | MSOD-T21 non-reversing starter, T21 frame, 5A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 5A (adjustable 4-6A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC12V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC24V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC48V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC100V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC110V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC125V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC200V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 6.6A DC220V | MSOD-T21 non-reversing starter, T21 frame, 6.6A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 6.6A (adjustable 5.2-8A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC12V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC24V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC48V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC100V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC110V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC125V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC200V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 9A DC220V | MSOD-T21 non-reversing starter, T21 frame, 9A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 9A (adjustable 7-11A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC12V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC24V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC48V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC100V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC110V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC125V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC200V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 11A DC220V | MSOD-T21 non-reversing starter, T21 frame, 11A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 11A (adjustable 9-13A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC12V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC12V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC12V (DC12V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC24V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC24V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC24V (DC24V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC48V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC48V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC48V (DC48V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC100V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC100V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC100V (DC100V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC110V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC110V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC110V (DC110V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC125V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC125V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC125V (DC120-125V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC200V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC200V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC200V (DC200V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 | |
| MSOD-T21 15A DC220V | MSOD-T21 non-reversing starter, T21 frame, 15A heater, DC220V coil | Mitsubishi Electric | Frame: T21 · Type: Non-Reversing Magnetic Starter (Open Type) · Poles: 3 · Operation: DC operated · Coil: DC220V (DC220V) · Thermal Relay: TH-T25 (2-element, manual reset) · Heater: 15A (adjustable 12-18A) · AC-3 Capacity: 4kW@200-220V / 7.5kW@380-440V / 7.5kW@500-550V · AC-3 Current: 18A@200-220V / 18A@380-440V / 17A@500-550V · AC-1 Current: 32A@200-220V / 32A@380-440V · Thermal Current Ith: 32A · Aux Contact: 2a2b · Standards: JIS C8201-4-1, IEC 60947-4-1, EN 60947-4-1, GB 14048.4 |