Throttle and Check Module. Used as pilot check valve for solenoid/pilot operated directional valves. Flow: 30 (01) / 80 (03) L/min. Max. operating pressure: 25 MPa. Gasket mounting. Meter-out (no symbol) / meter-in (-A) on size 03.
Throttle and Check Module. Used as pilot check valve for solenoid/pilot operated directional valves. Flow: 30 (01) / 80 (03) L/min. Max. operating pressure: 25 MPa. Gasket mounting. Meter-out (no symbol) / meter-in (-A) on size 03.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TC2G-01-40 | Throttle and Check Module TC2G-01-40 | Yuken | Type: Throttle and Check Module | Mounting: Gasket | Valve Size: 01 | Circuit: — | Flow: 30 L/min | Max. Operating Pressure: 25 MPa | Mass: 0.65 kg | Design No.: 40 | |
| TC2G-03-40 | Throttle and Check Module TC2G-03-40 | Yuken | Type: Throttle and Check Module | Mounting: Gasket | Valve Size: 03 | Circuit: Meter-out | Flow: 80 L/min | Max. Operating Pressure: 25 MPa | Mass: 1.8 kg | Design No.: 40 | |
| TC2G-03-A-40 | Throttle and Check Module TC2G-03-A-40 | Yuken | Type: Throttle and Check Module | Mounting: Gasket | Valve Size: 03 | Circuit: -A (Meter-in) | Flow: 80 L/min | Max. Operating Pressure: 25 MPa | Mass: 1.8 kg | Design No.: 40 |
Throttle Module. Used as pilot check valve for solenoid/pilot operated directional valves. Flow: 30 (01) / 80 (03) L/min. Max. operating pressure: 25 MPa. Gasket mounting. Backflow-prevention check valve (-C) on size 03.
Throttle Module. Used as pilot check valve for solenoid/pilot operated directional valves. Flow: 30 (01) / 80 (03) L/min. Max. operating pressure: 25 MPa. Gasket mounting. Backflow-prevention check valve (-C) on size 03.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| TC1G-01-40 | Throttle Module TC1G-01-40 | Yuken | Type: Throttle Module | Mounting: Gasket | Valve Size: 01 | Option: None | Flow: 30 L/min | Max. Operating Pressure: 25 MPa | Mass: 0.6 kg | Design No.: 40 | |
| TC1G-03-40 | Throttle Module TC1G-03-40 | Yuken | Type: Throttle Module | Mounting: Gasket | Valve Size: 03 | Option: None | Flow: 80 L/min | Max. Operating Pressure: 25 MPa | Mass: 1.6 kg | Design No.: 40 | |
| TC1G-03-C-40 | Throttle Module TC1G-03-C-40 | Yuken | Type: Throttle Module | Mounting: Gasket | Valve Size: 03 | Option: -C (Backflow-prevention check valve built-in) | Flow: 80 L/min | Max. Operating Pressure: 25 MPa | Mass: 1.6 kg | Design No.: 40 |
005 Series Modular Valves — Check. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MCP-005-0-20 | Check modular valve 005, P-line | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Check (P-line) |
005 Series Modular Valves — Modular Base Plate. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Modular Base Plate. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMC-005 | Base plate (sub-plate) — number of stations by inquiry (RFQ) | Yuken | Series: 005 (Modular) | Function: Base plate (sub-plate) | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MMC-005-[stations]-20 | Number of stations (RFQ): specify at order — catalog details by inquiry | Design: -20 |
005 Series Modular Valves — Modular End Plate (Blocking / Bypass). Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Modular End Plate (Blocking / Bypass). Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MDC-005-A-20 | End/blocking plate 005 | Yuken | Series: 005 Modular | Type: End/blocking plate | Max Pressure: 25 MPa |
005 Series Modular Valves — Modular Mounting Bolt Kit. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Modular Mounting Bolt Kit. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MBK-005 | Mounting bolt kit — bolt code by inquiry (RFQ) | Yuken | Series: 005 (Modular) | Function: Mounting bolt kit | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MBK-005-[bolt code]-10 | Bolt code (RFQ): specify at order — catalog details by inquiry | Design: -10 |
005 Series Modular Valves — Pilot Operated Check. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Pilot Operated Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MPA-005-2-20 | Pilot operated check modular valve 005, A-line | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Pilot operated check (A-line) | |
| MPB-005-2-20 | Pilot operated check modular valve 005, B-line | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Pilot operated check (B-line) | |
| MPW-005-2-20 | Pilot operated check modular valve 005, A & B line | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Pilot operated check (A & B line) |
005 Series Modular Valves — Reducing. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Reducing. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MRP-005 | Pressure reducing (P-line) — pressure range by inquiry (RFQ) | Yuken | Series: 005 (Modular) | Function: Pressure reducing (P-line) | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MRP-005-[range]-20 | Pressure range (RFQ): specify at order — catalog details by inquiry | Design: -20 |
005 Series Modular Valves — Relief. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Relief. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MBP-005 | Relief (P-line) — pressure range by inquiry (RFQ) | Yuken | Series: 005 (Modular) | Function: Relief (P-line) | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MBP-005-[range]-20 | Pressure range (RFQ): specify at order — catalog details by inquiry | Design: -20 |
005 Series Modular Valves — Throttle & Check. Sandwich/stack mounting. Detailed specifications by inquiry.
005 Series Modular Valves — Throttle & Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSA-005-X-20 | Throttle-and-check modular valve 005, A-line, meter-out | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (A-line, meter-out) | Control Code: X | |
| MSA-005-Y-20 | Throttle-and-check modular valve 005, A-line, meter-in | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (A-line, meter-in) | Control Code: Y | |
| MSB-005-X-20 | Throttle-and-check modular valve 005, B-line, meter-out | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (B-line, meter-out) | Control Code: X | |
| MSB-005-Y-20 | Throttle-and-check modular valve 005, B-line, meter-in | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (B-line, meter-in) | Control Code: Y | |
| MSW-005-X-20 | Throttle-and-check modular valve 005, A & B line, meter-out | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (A & B line, meter-out) | Control Code: X | |
| MSW-005-Y-20 | Throttle-and-check modular valve 005, A & B line, meter-in | Yuken | Series: 005 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (005 - non-ISO 4401) | Function: Throttle & check (A & B line, meter-in) | Control Code: Y |
007 Series Modular Valves — Modular Base Plate. Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Modular Base Plate. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MMC-007 | Base plate (sub-plate) — number of stations by inquiry (RFQ) | Yuken | Series: 007 (Modular) | Function: Base plate (sub-plate) | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MMC-007-[stations]-10 | Number of stations (RFQ): specify at order — catalog details by inquiry | Design: -10 |
007 Series Modular Valves — Modular End Plate (Blocking / Bypass). Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Modular End Plate (Blocking / Bypass). Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MDC-007-A-10 | End/blocking plate 007 | Yuken | Series: 007 Modular | Type: End/blocking plate | Max Pressure: 25 MPa |
007 Series Modular Valves — Modular Mounting Bolt Kit. Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Modular Mounting Bolt Kit. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MBK-007 | Mounting bolt kit — bolt code by inquiry (RFQ) | Yuken | Series: 007 (Modular) | Function: Mounting bolt kit | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MBK-007-[bolt code]-10 | Bolt code (RFQ): specify at order — catalog details by inquiry | Design: -10 |
007 Series Modular Valves — Pilot Operated Check. Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Pilot Operated Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MPA-007-2-10 | Pilot operated check modular valve 007, A-line | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Pilot operated check (A-line) | |
| MPB-007-2-10 | Pilot operated check modular valve 007, B-line | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Pilot operated check (B-line) | |
| MPW-007-2-10 | Pilot operated check modular valve 007, A & B line | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Pilot operated check (A & B line) |
007 Series Modular Valves — Reducing. Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Reducing. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MRP-007 | Pressure reducing (P-line) — pressure range by inquiry (RFQ) | Yuken | Series: 007 (Modular) | Function: Pressure reducing (P-line) | Mounting: Sandwich/stack (ISO 4401) | Code Pattern: MRP-007-[range]-10 | Pressure range (RFQ): specify at order — catalog details by inquiry | Design: -10 |
007 Series Modular Valves — Throttle & Check. Sandwich/stack mounting. Detailed specifications by inquiry.
007 Series Modular Valves — Throttle & Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSA-007-X-10 | Throttle-and-check modular valve 007, A-line, meter-out | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (A-line, meter-out) | Control Code: X | |
| MSA-007-Y-10 | Throttle-and-check modular valve 007, A-line, meter-in | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (A-line, meter-in) | Control Code: Y | |
| MSB-007-X-10 | Throttle-and-check modular valve 007, B-line, meter-out | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (B-line, meter-out) | Control Code: X | |
| MSB-007-Y-10 | Throttle-and-check modular valve 007, B-line, meter-in | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (B-line, meter-in) | Control Code: Y | |
| MSW-007-X-10 | Throttle-and-check modular valve 007, A & B line, meter-out | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (A & B line, meter-out) | Control Code: X | |
| MSW-007-Y-10 | Throttle-and-check modular valve 007, A & B line, meter-in | Yuken | Series: 007 Modular | Max Pressure: 25 MPa | Max Flow: 15 L/min | Mounting: Sandwich/stack (ISO 4401) | Function: Throttle & check (A & B line, meter-in) | Control Code: Y |
01 Series Modular Valves — Anti-Cavitation. Sandwich/stack mounting. Detailed specifications by inquiry.
01 Series Modular Valves — Anti-Cavitation. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MAC-01-30 | Anti-cavitation modular valve 01 | Yuken | Series: 01 Modular (1/8) | Max Pressure: 35 MPa | Max Flow: per module - RFQ | Mounting: Sandwich/stack (ISO 4401) | Function: Anti-cavitation |
01 Series Modular Valves — Brake. Sandwich/stack mounting. Detailed specifications by inquiry.
01 Series Modular Valves — Brake. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MBR-01-C-30 | Brake modular valve, range C | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Brake | Pressure Range: C: max 14 MPa | Max Pressure: 25 MPa | Max Flow: 35 L/min | |
| MBR-01-H-30 | Brake modular valve, range H | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Brake | Pressure Range: H: 7–21 MPa | Max Pressure: 25 MPa | Max Flow: 35 L/min |
01 Series Modular Valves — Check. Sandwich/stack mounting. Detailed specifications by inquiry.
01 Series Modular Valves — Check. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MCP-01-0-70 | Check modular valve, P-line, cracking 0.035 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (P-line) | Cracking Pressure: 0: 0.035 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCP-01-2-70 | Check modular valve, P-line, cracking 0.2 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (P-line) | Cracking Pressure: 2: 0.2 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCP-01-4-70 | Check modular valve, P-line, cracking 0.4 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (P-line) | Cracking Pressure: 4: 0.4 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCA-01-0-70 | Check modular valve, A-line, cracking 0.035 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A-line) | Cracking Pressure: 0: 0.035 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCA-01-2-70 | Check modular valve, A-line, cracking 0.2 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A-line) | Cracking Pressure: 2: 0.2 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCA-01-4-70 | Check modular valve, A-line, cracking 0.4 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A-line) | Cracking Pressure: 4: 0.4 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCB-01-0-70 | Check modular valve, B-line, cracking 0.035 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (B-line) | Cracking Pressure: 0: 0.035 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCB-01-2-70 | Check modular valve, B-line, cracking 0.2 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (B-line) | Cracking Pressure: 2: 0.2 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCB-01-4-70 | Check modular valve, B-line, cracking 0.4 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (B-line) | Cracking Pressure: 4: 0.4 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCT-01-0-70 | Check modular valve, T-line, cracking 0.035 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (T-line) | Cracking Pressure: 0: 0.035 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCT-01-2-70 | Check modular valve, T-line, cracking 0.2 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (T-line) | Cracking Pressure: 2: 0.2 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCT-01-4-70 | Check modular valve, T-line, cracking 0.4 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (T-line) | Cracking Pressure: 4: 0.4 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCW-01-0-70 | Check modular valve, A·B-line, cracking 0.035 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A·B-line) | Cracking Pressure: 0: 0.035 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCW-01-2-70 | Check modular valve, A·B-line, cracking 0.2 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A·B-line) | Cracking Pressure: 2: 0.2 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min | |
| MCW-01-4-70 | Check modular valve, A·B-line, cracking 0.4 MPa | Yuken | Series: 01 (1/8) Modular | Mounting: Sandwich/stack (ISO 4401) | Function: Check (A·B-line) | Cracking Pressure: 4: 0.4 MPa | Max Pressure: 35 MPa | Max Flow: 60 L/min |
01 Series Modular Valves — Check-Throttle. Sandwich/stack mounting. Detailed specifications by inquiry.
01 Series Modular Valves — Check-Throttle. Sandwich/stack mounting. Detailed specifications by inquiry.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MSCP-01-30 | Check-throttle modular valve 01, P-line | Yuken | Series: 01 Modular (1/8) | Max Pressure: 35 MPa | Max Flow: per module - RFQ | Mounting: Sandwich/stack (ISO 4401) | Function: Check + throttle (P-line) |