Hydraulics
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, rated current 600 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, rated current 600 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFG-03-60-26 | EFG-03 40ohm Flow Control (E), 60L/min, N-opt: none | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 2–60 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: None | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 12.5 kg | Design No.: 26 | |
| EFG-03-60-N-2603 | EFG-03 40ohm Flow Control (E), 60L/min, N-opt: N | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 2–60 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: Pressure-compensation piston opening-adjustment screw (made to order — consult) | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 12.5 kg | Design No.: 2603 | |
| EFG-03-125-26 | EFG-03 40ohm Flow Control (E), 125L/min, N-opt: none | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 2–125 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: None | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 12.5 kg | Design No.: 26 | |
| EFG-03-125-N-2603 | EFG-03 40ohm Flow Control (E), 125L/min, N-opt: N | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 2–125 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: Pressure-compensation piston opening-adjustment screw (made to order — consult) | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 12.5 kg | Design No.: 2603 |
10Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, rated current 820 mA. Internal/external pilot. Coil resistance 10Ω.
10Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, rated current 820 mA. Internal/external pilot. Coil resistance 10Ω.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFG-06-250-51 | EFG-06 10ohm Flow Control (E), 250L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 10Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Max Pressure: 24.5 MPa | Pilot: Internal pilot | Rated Current: 820 mA | Pressure/Temperature compensated: Yes | Coil: 10Ω | Drive: Current input (use with dedicated power amplifier) | Mass: 25 kg | Design No.: 51 | |
| EFG-06-250-E-51 | EFG-06 10ohm Flow Control (E), 250L/min, External pilot | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 10Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Max Pressure: 24.5 MPa | Pilot: External pilot | Rated Current: 820 mA | Pressure/Temperature compensated: Yes | Coil: 10Ω | Drive: Current input (use with dedicated power amplifier) | Mass: 25 kg | Design No.: 51 |
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 20.6 MPa, max adjustable flow 250 L/min, rated current 600 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 06. Max operating pressure 20.6 MPa, max adjustable flow 250 L/min, rated current 600 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFG-06-250-22 | EFG-06 40ohm Flow Control (E), 250L/min, N-opt: none | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 3–250 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: None | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 25 kg | Design No.: 22 | |
| EFG-06-250-N-22 | EFG-06 40ohm Flow Control (E), 250L/min, N-opt: N | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 3–250 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: Pressure-compensation piston opening-adjustment screw (made to order — consult) | Rated Current: 600 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 25 kg | Design No.: 22 |
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 20.6 MPa, max adjustable flow 500 L/min, rated current 700 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
40Ω Series Proportional Electro-Hydraulic Flow Control Valves. E-series current-driven valve: set flow changes continuously in proportion to the input current, so system flow can be remotely controlled from a power amplifier; pressure- and temperature-compensated, so set flow is unaffected by load pressure or oil temperature. Suited to shock-free start/stop/speed-change of actuators. Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 10. Max operating pressure 20.6 MPa, max adjustable flow 500 L/min, rated current 700 mA. Coil resistance 45Ω (40Ω series), hysteresis 7%. Optional pressure-compensation piston opening-adjustment screw (N).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EFG-10-500-11 | EFG-10 40ohm Flow Control (E), 500L/min, N-opt: none | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: None | Rated Current: 700 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 51 kg | Design No.: 11 | |
| EFG-10-500-N-11 | EFG-10 40ohm Flow Control (E), 500L/min, N-opt: N | Yuken | Type: Proportional Flow Control Valve (E series, current-driven, 40Ω) | Series: EFG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Max Pressure: 20.6 MPa | Pressure-comp. Adjustment Screw: Pressure-compensation piston opening-adjustment screw (made to order — consult) | Rated Current: 700 mA | Coil: 45Ω | Pressure/Temperature compensated: Yes | Hysteresis: 7% | Drive: Current input (use with dedicated power amplifier) | Mass: 51 kg | Design No.: 11 |
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 100 L/min. Pressure adjustment range C: 0.6–15.7 MPa / H: 0.6–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 100 L/min. Pressure adjustment range C: 0.6–15.7 MPa / H: 0.6–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHBG-03-C-50 | EHBG-03 Relief, C 0.6–15.7 MPa, Open loop, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: C (0.6–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-03-C-S-50 | EHBG-03 Relief, C 0.6–15.7 MPa, Open loop + built-in sensor, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: C (0.6–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-03-C-L-50 | EHBG-03 Relief, C 0.6–15.7 MPa, Closed loop, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: C (0.6–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-03-H-50 | EHBG-03 Relief, H 0.6–24.5 MPa, Open loop, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: H (0.6–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-03-H-S-50 | EHBG-03 Relief, H 0.6–24.5 MPa, Open loop + built-in sensor, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: H (0.6–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-03-H-L-50 | EHBG-03 Relief, H 0.6–24.5 MPa, Closed loop, max 100 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Flow: 100 L/min | Pressure Adj. Range: H (0.6–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 200 L/min. Pressure adjustment range C: 0.9–15.7 MPa / H: 0.9–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 200 L/min. Pressure adjustment range C: 0.9–15.7 MPa / H: 0.9–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHBG-06-C-50 | EHBG-06 Relief, C 0.9–15.7 MPa, Open loop, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: C (0.9–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-06-C-S-50 | EHBG-06 Relief, C 0.9–15.7 MPa, Open loop + built-in sensor, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: C (0.9–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-06-C-L-50 | EHBG-06 Relief, C 0.9–15.7 MPa, Closed loop, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: C (0.9–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-06-H-50 | EHBG-06 Relief, H 0.9–24.5 MPa, Open loop, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: H (0.9–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-06-H-S-50 | EHBG-06 Relief, H 0.9–24.5 MPa, Open loop + built-in sensor, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: H (0.9–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-06-H-L-50 | EHBG-06 Relief, H 0.9–24.5 MPa, Closed loop, max 200 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 200 L/min | Pressure Adj. Range: H (0.9–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 400 L/min. Pressure adjustment range C: 1.1–15.7 MPa / H: 1.1–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
Proportional Electro-Hydraulic Relief Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a low-noise relief valve; controls system pressure proportionally to input voltage. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 400 L/min. Pressure adjustment range C: 1.1–15.7 MPa / H: 1.1–24.5 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop, sensor-equipped (S) and closed-loop (L) versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHBG-10-C-50 | EHBG-10 Relief, C 1.1–15.7 MPa, Open loop, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: C (1.1–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-10-C-S-50 | EHBG-10 Relief, C 1.1–15.7 MPa, Open loop + built-in sensor, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: C (1.1–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-10-C-L-50 | EHBG-10 Relief, C 1.1–15.7 MPa, Closed loop, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: C (1.1–15.7 MPa) | Max Pressure: 15.7 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-10-H-50 | EHBG-10 Relief, H 1.1–24.5 MPa, Open loop, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: H (1.1–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-10-H-S-50 | EHBG-10 Relief, H 1.1–24.5 MPa, Open loop + built-in sensor, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: H (1.1–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHBG-10-H-L-50 | EHBG-10 Relief, H 1.1–24.5 MPa, Closed loop, max 400 L/min | Yuken | Type: Proportional Relief Valve | Series: EHBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 400 L/min | Pressure Adj. Range: H (1.1–24.5 MPa) | Max Pressure: 24.5 MPa | Control: Closed loop | Coil: 10Ω, DC24V | Design No.: 50 |
[Yuken] — EHDFG-01 Proportional Directional & Flow Control Valve (25 MPa, rated 30 L/min, size 01)
▶Proportional Electro-Hydraulic Directional and Flow Control Valves. Combines speed (flow) control and directional control in a single valve, so that an actuator's speed and direction can both be handled without a separate directional valve, simplifying the hydraulic circuit and reducing cost. Sub-plate mounting, valve size 01. Max operating pressure 25 MPa, tank port pressure 7 MPa, rated flow 30 L/min at 6.7 MPa valve pressure drop. Spool forms 3C2 and 3C40; meter-in (Y), meter-out (X) and meter-in/out (XY) control. Coil 10.5Ω, supply DC24V (40 W max).
Proportional Electro-Hydraulic Directional and Flow Control Valves. Combines speed (flow) control and directional control in a single valve, so that an actuator's speed and direction can both be handled without a separate directional valve, simplifying the hydraulic circuit and reducing cost. Sub-plate mounting, valve size 01. Max operating pressure 25 MPa, tank port pressure 7 MPa, rated flow 30 L/min at 6.7 MPa valve pressure drop. Spool forms 3C2 and 3C40; meter-in (Y), meter-out (X) and meter-in/out (XY) control. Coil 10.5Ω, supply DC24V (40 W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDFG-01-30-3C2-XY-30 | EHDFG-01 Directional&Flow, 3C2, Meter-in / Meter-out control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-in / Meter-out control (XY) | Coil: 10.5Ω, DC24V | Design No.: 30 | |
| EHDFG-01-30-3C2-X-30 | EHDFG-01 Directional&Flow, 3C2, Meter-out control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-out control (X) | Coil: 10.5Ω, DC24V | Design No.: 30 | |
| EHDFG-01-30-3C2-Y-30 | EHDFG-01 Directional&Flow, 3C2, Meter-in control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-in control (Y) | Coil: 10.5Ω, DC24V | Design No.: 30 | |
| EHDFG-01-30-3C40-XY-30 | EHDFG-01 Directional&Flow, 3C40, Meter-in / Meter-out control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-in / Meter-out control (XY) | Coil: 10.5Ω, DC24V | Design No.: 30 | |
| EHDFG-01-30-3C40-X-30 | EHDFG-01 Directional&Flow, 3C40, Meter-out control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-out control (X) | Coil: 10.5Ω, DC24V | Design No.: 30 | |
| EHDFG-01-30-3C40-Y-30 | EHDFG-01 Directional&Flow, 3C40, Meter-in control, rated 30L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 30 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-in control (Y) | Coil: 10.5Ω, DC24V | Design No.: 30 |
[Yuken] — EHDFG-03 Proportional Directional & Flow Control Valve (25 MPa, rated 60 L/min, size 03)
▶Proportional Electro-Hydraulic Directional and Flow Control Valves. Combines speed (flow) control and directional control in a single valve, so that an actuator's speed and direction can both be handled without a separate directional valve, simplifying the hydraulic circuit and reducing cost. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, tank port pressure 7 MPa, rated flow 60 L/min at 6.7 MPa valve pressure drop. Spool forms 3C2 and 3C40; meter-in (Y), meter-out (X) and meter-in/out (XY) control. Coil 8.0Ω, supply DC24V (45 W max).
Proportional Electro-Hydraulic Directional and Flow Control Valves. Combines speed (flow) control and directional control in a single valve, so that an actuator's speed and direction can both be handled without a separate directional valve, simplifying the hydraulic circuit and reducing cost. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, tank port pressure 7 MPa, rated flow 60 L/min at 6.7 MPa valve pressure drop. Spool forms 3C2 and 3C40; meter-in (Y), meter-out (X) and meter-in/out (XY) control. Coil 8.0Ω, supply DC24V (45 W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDFG-03-60-3C2-XY-30 | EHDFG-03 Directional&Flow, 3C2, Meter-in / Meter-out control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-in / Meter-out control (XY) | Coil: 8.0Ω, DC24V | Design No.: 30 | |
| EHDFG-03-60-3C2-X-30 | EHDFG-03 Directional&Flow, 3C2, Meter-out control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-out control (X) | Coil: 8.0Ω, DC24V | Design No.: 30 | |
| EHDFG-03-60-3C2-Y-30 | EHDFG-03 Directional&Flow, 3C2, Meter-in control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C2 | Control Direction: Meter-in control (Y) | Coil: 8.0Ω, DC24V | Design No.: 30 | |
| EHDFG-03-60-3C40-XY-30 | EHDFG-03 Directional&Flow, 3C40, Meter-in / Meter-out control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-in / Meter-out control (XY) | Coil: 8.0Ω, DC24V | Design No.: 30 | |
| EHDFG-03-60-3C40-X-30 | EHDFG-03 Directional&Flow, 3C40, Meter-out control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-out control (X) | Coil: 8.0Ω, DC24V | Design No.: 30 | |
| EHDFG-03-60-3C40-Y-30 | EHDFG-03 Directional&Flow, 3C40, Meter-in control, rated 60L/min | Yuken | Type: Proportional Directional & Flow Control Valve | Series: EHDFG | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 60 L/min (@6.7 MPa drop) | Max Pressure: 25 MPa | Tank Port Pressure: 7 MPa | Spool Form: 3C40 | Control Direction: Meter-in control (Y) | Coil: 8.0Ω, DC24V | Design No.: 30 |
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A high-response valve developed to draw out the maximum performance of the proportional directional & flow control valve: a differential transformer (LVDT) that detects the main spool position is combined with a power amplifier to form a closed loop inside the valve, giving high accuracy and reliability. Usable in open-loop control and, as a simple servo valve, in closed-loop control. Sub-plate mounting, valve size 04. Max operating pressure 15.7 MPa, rated flow 130 L/min at 6.7 MPa valve pressure drop. Spool forms 2 and 40; internal/external pilot; optional relief-type pressure-compensation valve. Coil 30Ω, supply DC±24V (20W max).
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A high-response valve developed to draw out the maximum performance of the proportional directional & flow control valve: a differential transformer (LVDT) that detects the main spool position is combined with a power amplifier to form a closed loop inside the valve, giving high accuracy and reliability. Usable in open-loop control and, as a simple servo valve, in closed-loop control. Sub-plate mounting, valve size 04. Max operating pressure 15.7 MPa, rated flow 130 L/min at 6.7 MPa valve pressure drop. Spool forms 2 and 40; internal/external pilot; optional relief-type pressure-compensation valve. Coil 30Ω, supply DC±24V (20W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDFG-04-130-2-10 | EHDFG-04 High-Response Dir&Flow, spool 2, Internal pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: Internal pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-2-CB-10 | EHDFG-04 High-Response Dir&Flow, spool 2, Internal pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: Internal pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-2-E-10 | EHDFG-04 High-Response Dir&Flow, spool 2, External pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: External pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-2-E-CB-10 | EHDFG-04 High-Response Dir&Flow, spool 2, External pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: External pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-40-10 | EHDFG-04 High-Response Dir&Flow, spool 40, Internal pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: Internal pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-40-CB-10 | EHDFG-04 High-Response Dir&Flow, spool 40, Internal pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: Internal pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-40-E-10 | EHDFG-04 High-Response Dir&Flow, spool 40, External pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: External pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-04-130-40-E-CB-10 | EHDFG-04 High-Response Dir&Flow, spool 40, External pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 04 | Rated Flow: 130 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: External pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 |
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A high-response valve developed to draw out the maximum performance of the proportional directional & flow control valve: a differential transformer (LVDT) that detects the main spool position is combined with a power amplifier to form a closed loop inside the valve, giving high accuracy and reliability. Usable in open-loop control and, as a simple servo valve, in closed-loop control. Sub-plate mounting, valve size 06. Max operating pressure 15.7 MPa, rated flow 280 L/min at 6.7 MPa valve pressure drop. Spool forms 2 and 40; internal/external pilot; optional relief-type pressure-compensation valve. Coil 30Ω, supply DC±24V (20W max).
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A high-response valve developed to draw out the maximum performance of the proportional directional & flow control valve: a differential transformer (LVDT) that detects the main spool position is combined with a power amplifier to form a closed loop inside the valve, giving high accuracy and reliability. Usable in open-loop control and, as a simple servo valve, in closed-loop control. Sub-plate mounting, valve size 06. Max operating pressure 15.7 MPa, rated flow 280 L/min at 6.7 MPa valve pressure drop. Spool forms 2 and 40; internal/external pilot; optional relief-type pressure-compensation valve. Coil 30Ω, supply DC±24V (20W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDFG-06-280-2-10 | EHDFG-06 High-Response Dir&Flow, spool 2, Internal pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: Internal pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-2-CB-10 | EHDFG-06 High-Response Dir&Flow, spool 2, Internal pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: Internal pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-2-E-10 | EHDFG-06 High-Response Dir&Flow, spool 2, External pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: External pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-2-E-CB-10 | EHDFG-06 High-Response Dir&Flow, spool 2, External pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 2 | Pilot: External pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-40-10 | EHDFG-06 High-Response Dir&Flow, spool 40, Internal pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: Internal pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-40-CB-10 | EHDFG-06 High-Response Dir&Flow, spool 40, Internal pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: Internal pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-40-E-10 | EHDFG-06 High-Response Dir&Flow, spool 40, External pilot, Without pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: External pilot | Pressure Compensation: Without pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 | |
| EHDFG-06-280-40-E-CB-10 | EHDFG-06 High-Response Dir&Flow, spool 40, External pilot, With relief-type pressure-compensation valve | Yuken | Type: High-Response Proportional Directional & Flow Control Valve | Series: EHDFG (High Response) | Mounting: Sub-plate (G) | Valve Size: 06 | Rated Flow: 280 L/min (@6.7 MPa drop) | Max Pressure: 15.7 MPa | Spool Form: 40 | Pilot: External pilot | Pressure Compensation: With relief-type pressure-compensation valve | Feedback: Built-in LVDT + power amplifier (internal closed loop) | Coil: 30Ω, DC±24V | Design No.: 10 |
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range B: 0.5–6.9 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range B: 0.5–6.9 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDG-01-B-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-1-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-1-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-1-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-1-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-S-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-S-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-S-1-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-B-S-1-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-S-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-S-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-S-1-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-S-1-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-L-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-L-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-L-1-PNT15-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-B-L-1-PNT15M10-50 | EHDG-01 Pilot Relief, B 0.5–6.9 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: B (0.5–6.9 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T15 (standard for B) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range C: 1.0–15.7 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range C: 1.0–15.7 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDG-01-C-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range H: 1.2–24.5 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range H: 1.2–24.5 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDG-01-H-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-60-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-E-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-E-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-250-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-E-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-250-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-E-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-500-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-E-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-500-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-E-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-1000 | EHFBG-10-1000 High-Flow Power-Saving, 1000 L/min, available by separate inquiry (RFQ) | Yuken | Type: High-Flow Proportional Power-Saving Valve | Series: EHFBG (High Flow) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Max Pressure: 24.5 MPa | Availability: Made to order — full options by separate inquiry (RFQ) |