Valves
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range C: 1.0–15.7 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range C: 1.0–15.7 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDG-01-C-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-C-S-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-S-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-1-PNT13-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-C-L-1-PNT13M10-50 | EHDG-01 Pilot Relief, C 1.0–15.7 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: C (1.0–15.7 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T13 (standard for C) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range H: 1.2–24.5 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
Proportional Electro-Hydraulic Pilot Relief Valves. Pressure adjustment range H: 1.2–24.5 MPa. Max. operating pressure 24.5 MPa. Max. flow 2 L/min. Min. flow 0.3 L/min. Coil resistance 10Ω. Supply DC24V (28W max). Sub-plate mounting. Valve size 01. Open-loop, sensor-equipped (S) and closed-loop (L) control versions; optional built-in safety valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHDG-01-H-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01-H-S-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: General purpose | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-S-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Open loop + built-in sensor, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Open loop + built-in sensor | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Without safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Without safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-1-PNT11-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: No P–B line orifice | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHDG-01V-H-L-1-PNT11M10-50 | EHDG-01 Pilot Relief, H 1.2–24.5 MPa, Closed loop, Built-in safety valve | Yuken | Type: Proportional Pilot Relief Valve | Series: EHDG | Mounting: Sub-plate (G) | Valve Size: 01 | Usage: Relief-valve vent control | Pressure Adj. Range: H (1.2–24.5 MPa) | Control: Closed loop | Safety Valve: Built-in safety valve | P-line Orifice: PN (none, standard) | T-line Orifice: T11 (standard for H) | P-B line Orifice: Standard P–B line orifice (M10) | Max Pressure: 24.5 MPa | Max Flow: 2 L/min | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-60-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-E-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-E-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-250-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-E-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-250-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-E-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-500-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-E-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-500-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-E-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-1000 | EHFBG-10-1000 High-Flow Power-Saving, 1000 L/min, available by separate inquiry (RFQ) | Yuken | Type: High-Flow Proportional Power-Saving Valve | Series: EHFBG (High Flow) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Max Pressure: 24.5 MPa | Availability: Made to order — full options by separate inquiry (RFQ) |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFCG-03-60-50 | EHFCG-03 Flow Control +Check, 60L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-60-E-50 | EHFCG-03 Flow Control +Check, 60L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-125-50 | EHFCG-03 Flow Control +Check, 125L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-125-E-50 | EHFCG-03 Flow Control +Check, 125L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFCG-06-250-50 | EHFCG-06 Flow Control +Check, 250L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Free Flow (check): 280 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-06-250-E-50 | EHFCG-06 Flow Control +Check, 250L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Free Flow (check): 280 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFG-03-60-50 | EHFG-03 Flow Control, 60L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-60-E-50 | EHFG-03 Flow Control, 60L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-125-50 | EHFG-03 Flow Control, 125L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-125-E-50 | EHFG-03 Flow Control, 125L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFG-06-250-50 | EHFG-06 Flow Control, 250L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-06-250-E-50 | EHFG-06 Flow Control, 250L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Relieving and Reducing Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a relief-built-in reducing valve; controls system pressure proportionally to input voltage with good response on pressure drop even at large flow. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 100 L/min, max relief flow 35 L/min. Pressure adjustment range B: 0.8–6.9 MPa / C: 1.2–13.7 MPa / H: 1.5–20.6 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop and sensor-equipped (S) versions.
Proportional Electro-Hydraulic Relieving and Reducing Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a relief-built-in reducing valve; controls system pressure proportionally to input voltage with good response on pressure drop even at large flow. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 100 L/min, max relief flow 35 L/min. Pressure adjustment range B: 0.8–6.9 MPa / C: 1.2–13.7 MPa / H: 1.5–20.6 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop and sensor-equipped (S) versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHRBG-06-B-50 | EHRBG-06 Relieving/Reducing, B 0.8–6.9 MPa, Open loop, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: B (0.8–6.9 MPa) | Max Pressure: 6.9 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-06-B-S-50 | EHRBG-06 Relieving/Reducing, B 0.8–6.9 MPa, Open loop + built-in sensor, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: B (0.8–6.9 MPa) | Max Pressure: 6.9 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-06-C-50 | EHRBG-06 Relieving/Reducing, C 1.2–13.7 MPa, Open loop, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: C (1.2–13.7 MPa) | Max Pressure: 13.7 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-06-C-S-50 | EHRBG-06 Relieving/Reducing, C 1.2–13.7 MPa, Open loop + built-in sensor, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: C (1.2–13.7 MPa) | Max Pressure: 13.7 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-06-H-50 | EHRBG-06 Relieving/Reducing, H 1.5–20.6 MPa, Open loop, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: H (1.5–20.6 MPa) | Max Pressure: 20.6 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-06-H-S-50 | EHRBG-06 Relieving/Reducing, H 1.5–20.6 MPa, Open loop + built-in sensor, max 100 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Flow: 100 L/min | Max Relief Flow: 35 L/min | Pressure Adj. Range: H (1.5–20.6 MPa) | Max Pressure: 20.6 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Relieving and Reducing Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a relief-built-in reducing valve; controls system pressure proportionally to input voltage with good response on pressure drop even at large flow. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 250 L/min, max relief flow 15 L/min. Pressure adjustment range B: 0.9–6.9 MPa / C: 1.2–13.7 MPa / H: 1.5–20.6 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop and sensor-equipped (S) versions.
Proportional Electro-Hydraulic Relieving and Reducing Valves. Integrates the compact high-performance EH-series 1/8 proportional pilot relief valve with a relief-built-in reducing valve; controls system pressure proportionally to input voltage with good response on pressure drop even at large flow. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 250 L/min, max relief flow 15 L/min. Pressure adjustment range B: 0.9–6.9 MPa / C: 1.2–13.7 MPa / H: 1.5–20.6 MPa. Coil resistance 10Ω, supply DC24V (28W max). Open-loop and sensor-equipped (S) versions.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHRBG-10-B-50 | EHRBG-10 Relieving/Reducing, B 0.9–6.9 MPa, Open loop, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: B (0.9–6.9 MPa) | Max Pressure: 6.9 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-10-B-S-50 | EHRBG-10 Relieving/Reducing, B 0.9–6.9 MPa, Open loop + built-in sensor, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: B (0.9–6.9 MPa) | Max Pressure: 6.9 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-10-C-50 | EHRBG-10 Relieving/Reducing, C 1.2–13.7 MPa, Open loop, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: C (1.2–13.7 MPa) | Max Pressure: 13.7 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-10-C-S-50 | EHRBG-10 Relieving/Reducing, C 1.2–13.7 MPa, Open loop + built-in sensor, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: C (1.2–13.7 MPa) | Max Pressure: 13.7 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-10-H-50 | EHRBG-10 Relieving/Reducing, H 1.5–20.6 MPa, Open loop, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: H (1.5–20.6 MPa) | Max Pressure: 20.6 MPa | Control: Open loop | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHRBG-10-H-S-50 | EHRBG-10 Relieving/Reducing, H 1.5–20.6 MPa, Open loop + built-in sensor, max 250 L/min | Yuken | Type: Proportional Relieving and Reducing Valve | Series: EHRBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Flow: 250 L/min | Max Relief Flow: 15 L/min | Pressure Adj. Range: H (1.5–20.6 MPa) | Max Pressure: 20.6 MPa | Control: Open loop + built-in sensor | Coil: 10Ω, DC24V | Design No.: 50 |
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A direct-operated, feedback (closed-loop) high-response valve combining a newly developed compact high-power solenoid with a spool-position differential transformer, giving high accuracy and reliability with simple-servo-class response; the zero-lap 3C2P spool is well suited to position and pressure control. Use with a dedicated Yuken external power amplifier. Sub-plate mounting, valve size 01, rated flow 10/20/35 L/min at 1.5 MPa valve pressure drop. Max operating pressure 31.5 MPa, tank pressure 21 MPa. Spool forms 3C2/3C40/3C2P; meter-in/meter-out (XY). Hysteresis 0.5%. Coil 3.9Ω, rated current max 2.5 A (25 W max).
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A direct-operated, feedback (closed-loop) high-response valve combining a newly developed compact high-power solenoid with a spool-position differential transformer, giving high accuracy and reliability with simple-servo-class response; the zero-lap 3C2P spool is well suited to position and pressure control. Use with a dedicated Yuken external power amplifier. Sub-plate mounting, valve size 01, rated flow 10/20/35 L/min at 1.5 MPa valve pressure drop. Max operating pressure 31.5 MPa, tank pressure 21 MPa. Spool forms 3C2/3C40/3C2P; meter-in/meter-out (XY). Hysteresis 0.5%. Coil 3.9Ω, rated current max 2.5 A (25 W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-01-10-3C2-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 10L/min, 3C2 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-10-3C40-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 10L/min, 3C40 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C40 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-10-3C2P-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 10L/min, 3C2P | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2P (zero-lap) | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-20-3C2-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 20L/min, 3C2 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-20-3C40-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 20L/min, 3C40 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C40 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-20-3C2P-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 20L/min, 3C2P | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2P (zero-lap) | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-35-3C2-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 35L/min, 3C2 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-35-3C40-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 35L/min, 3C40 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C40 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-01-35-3C2P-XY-10 | ELDFG-01 High-Response Dir&Flow (E), 35L/min, 3C2P | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2P (zero-lap) | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3.9Ω, rated current max 2.5 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 |
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 10 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 10 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-01EH-10-3C2-XY-C-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-C-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-C-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-A-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-A-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-A-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-B-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-B-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2-XY-B-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-C-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-C-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-C-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-A-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-A-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-A-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-B-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-B-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C40-XY-B-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C40, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-C-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-C-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-C-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-A-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-A-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-A-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-B-D-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-B-E-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-10-3C2L-XY-B-F-10 | ELDFG-01EH-10 High-Response Dir&Flow, 3C2L, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 10 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 |
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 20 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 20 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-01EH-20-3C2-XY-C-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-C-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-C-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-A-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-A-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-A-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-B-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-B-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2-XY-B-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-C-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-C-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-C-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-A-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-A-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-A-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-B-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-B-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C40-XY-B-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C40, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-C-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-C-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-C-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-A-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-A-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-A-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-B-D-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-B-E-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-20-3C2L-XY-B-F-10 | ELDFG-01EH-20 High-Response Dir&Flow, 3C2L, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 20 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 |
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 35 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 01, rated flow 35 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 3Ω, supply DC24V (75 VA min), 6+PE connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-01EH-35-3C2-XY-C-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-C-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-C-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-A-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-A-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-A-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-B-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-B-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2-XY-B-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-C-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-C-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-C-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-A-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-A-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-A-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-B-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-B-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C40-XY-B-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C40, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-C-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-C-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-C-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-A-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-A-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-A-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-B-D-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-B-E-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-01EH-35-3C2L-XY-B-F-10 | ELDFG-01EH-35 High-Response Dir&Flow, 3C2L, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 01 | Rated Flow: 35 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 3Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 |
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A direct-operated, feedback (closed-loop) high-response valve combining a newly developed compact high-power solenoid with a spool-position differential transformer, giving high accuracy and reliability with simple-servo-class response; the zero-lap 3C2P spool is well suited to position and pressure control. Use with a dedicated Yuken external power amplifier. Sub-plate mounting, valve size 03, rated flow 40/80 L/min at 1.5 MPa valve pressure drop. Max operating pressure 31.5 MPa, tank pressure 21 MPa. Spool forms 3C2/3C40/3C2P; meter-in/meter-out (XY). Hysteresis 0.5%. Coil 3Ω, rated current max 3 A (27 W max).
High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A direct-operated, feedback (closed-loop) high-response valve combining a newly developed compact high-power solenoid with a spool-position differential transformer, giving high accuracy and reliability with simple-servo-class response; the zero-lap 3C2P spool is well suited to position and pressure control. Use with a dedicated Yuken external power amplifier. Sub-plate mounting, valve size 03, rated flow 40/80 L/min at 1.5 MPa valve pressure drop. Max operating pressure 31.5 MPa, tank pressure 21 MPa. Spool forms 3C2/3C40/3C2P; meter-in/meter-out (XY). Hysteresis 0.5%. Coil 3Ω, rated current max 3 A (27 W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-03-40-3C2-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 40L/min, 3C2 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-03-40-3C40-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 40L/min, 3C40 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C40 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-03-40-3C2P-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 40L/min, 3C2P | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2P (zero-lap) | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-03-80-3C2-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 80L/min, 3C2 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 80 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-03-80-3C40-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 80L/min, 3C40 | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 80 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C40 | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 | |
| ELDFG-03-80-3C2P-XY-10 | ELDFG-03 High-Response Dir&Flow (E), 80L/min, 3C2P | Yuken | Type: High-Response Direct-Operated Proportional Directional & Flow Control Valve (E series) | Series: ELDFG | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 80 L/min (@ΔP=1.5 MPa) | Max Pressure: 31.5 MPa | Tank Pressure: 21 MPa | Spool Form: 3C2P (zero-lap) | Control Direction: XY (meter-in/meter-out) | Hysteresis: 0.5% | Coil: 3Ω, rated current max 3 A | Feedback: Spool-position differential transformer (closed loop) | Drive: Use with dedicated external power amplifier | Design No.: 10 |
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 03, rated flow 40 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 2Ω, supply DC24V (75 VA min), 6+PE connector.
Direct Operated and High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves. A closed-loop, amplifier-onboard high-response directional/flow valve with rated flow up to 80 L/min (@ΔP=1 MPa). Mounting the amplifier on the compact ELDFG body and simplifying wiring makes it easy to use; a newly developed compact high-power solenoid combined with a spool-position differential transformer gives servo-valve-class response, accuracy and reliability. The zero-lap 3C2L spool is optimal for position and pressure control. Sub-plate mounting, valve size 03, rated flow 40 L/min. Max operating pressure 35 MPa, tank back-pressure 21 MPa. Hysteresis 0.1%. Vibration resistance 10 G, IP65. Coil resistance 2Ω, supply DC24V (75 VA min), 6+PE connector.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELDFG-03EH-40-3C2-XY-C-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-C-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-C-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-A-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-A-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-A-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-B-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-B-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2-XY-B-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2 (10% overlap) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-C-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-C-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-C-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-A-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-A-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-A-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-B-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-B-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C40-XY-B-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C40, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C40 (A·B·T connected) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-C-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety C, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-C-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety C, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-C-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety C, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: C (Neutral) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-A-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety A, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-A-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety A, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-A-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety A, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: A (P→A, B→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-B-D-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety B, input D | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: D (Voltage ±10 V (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-B-E-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety B, input E | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: E (Current 4–20 mA (PABT flow at 12–20 mA input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 | |
| ELDFG-03EH-40-3C2L-XY-B-F-10 | ELDFG-03EH-40 High-Response Dir&Flow, 3C2L, safety B, input F | Yuken | Type: Direct-Operated High-Response Proportional Directional & Flow Control Valve | Series: ELDFG (amplifier-onboard) | Mounting: Sub-plate (G) | Valve Size: 03 | Rated Flow: 40 L/min (@ΔP=1 MPa) | Max Pressure: 35 MPa | Tank Back-Pressure: 21 MPa | Spool Form: 3C2L (2% overlap, linear flow gain) | Control Direction: XY (meter-in/meter-out) | Safety Function: B (P→B, A→T shift) | Input Signal / Spool Monitor: F (Current ±10 mA (PABT flow at + input)) | Hysteresis: 0.1% | Protection: IP65 | Vibration: 10 G | Coil: 2Ω, DC24V (75 VA min) | Connector: 6+PE | Design No.: 10 |