Fiber Optic
Limited-reflective fiber optic sensor head for stable glass detection in wet processes. Heat-resistant PVC and fluororesin construction handles cleaning, etching, and resist developing environments up to 60°C. Non-contact detection with high resistance to liquid splatter — operates reliably even in misty environments. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 19~31mm from mounting hole A center (recommended 22mm). Material: Heat-resistant PVC + Fluororesin (PFA). Protection: IP67 @ 60°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Cleaning, Etching, Resist Developing.
Limited-reflective fiber optic sensor head for stable glass detection in wet processes. Heat-resistant PVC and fluororesin construction handles cleaning, etching, and resist developing environments up to 60°C. Non-contact detection with high resistance to liquid splatter — operates reliably even in misty environments. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 19~31mm from mounting hole A center (recommended 22mm). Material: Heat-resistant PVC + Fluororesin (PFA). Protection: IP67 @ 60°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Cleaning, Etching, Resist Developing.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-L11FP 2M | OMRON E32-L11FP fiber optic sensor head, Heat-resistant PVC body, 2m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 19~31mm from mounting hole A center (recommended 22mm) | Cable Length: 2m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: Heat-resistant PVC + Fluororesin (PFA) | Protection: IP67 @ 60°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Cleaning, Etching, Resist Developing | |
| E32-L11FP 5M | OMRON E32-L11FP fiber optic sensor head, Heat-resistant PVC body, 5m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 19~31mm from mounting hole A center (recommended 22mm) | Cable Length: 5m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: Heat-resistant PVC + Fluororesin (PFA) | Protection: IP67 @ 60°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Cleaning, Etching, Resist Developing |
Limited-reflective fiber optic sensor head for stable glass detection in high-temperature wet processes. SUS316L stainless steel and fluororesin construction withstands resist stripping environments up to 85°C. Non-contact detection with high resistance to chemical splatter — operates reliably even in misty environments. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 32~44mm from mounting hole A center (recommended 35mm). Material: SUS316L + Fluororesin (PFA). Protection: IP67 @ 85°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Resist Stripping (high-temperature wet process).
Limited-reflective fiber optic sensor head for stable glass detection in high-temperature wet processes. SUS316L stainless steel and fluororesin construction withstands resist stripping environments up to 85°C. Non-contact detection with high resistance to chemical splatter — operates reliably even in misty environments. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 32~44mm from mounting hole A center (recommended 35mm). Material: SUS316L + Fluororesin (PFA). Protection: IP67 @ 85°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Resist Stripping (high-temperature wet process).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-L11FS 2M | OMRON E32-L11FS fiber optic sensor head, SUS316L body, 2m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 32~44mm from mounting hole A center (recommended 35mm) | Cable Length: 2m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: SUS316L + Fluororesin (PFA) | Protection: IP67 @ 85°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Resist Stripping (high-temperature wet process) | |
| E32-L11FS 5M | OMRON E32-L11FS fiber optic sensor head, SUS316L body, 5m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 32~44mm from mounting hole A center (recommended 35mm) | Cable Length: 5m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: SUS316L + Fluororesin (PFA) | Protection: IP67 @ 85°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Resist Stripping (high-temperature wet process) |
Limited-reflective fiber optic sensor head for stable glass detection in wet processes with extended mounting distance. SUS316L stainless steel and fluororesin construction handles resist stripping environments up to 70°C. Longer sensing range from mounting hole (32~44mm) provides flexible installation options. Non-contact detection with high resistance to chemical splatter. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 32~44mm from mounting hole A center (recommended 35mm). Material: SUS316L + Fluororesin (PFA). Protection: IP67 @ 70°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Resist Stripping (longer mounting distance).
Limited-reflective fiber optic sensor head for stable glass detection in wet processes with extended mounting distance. SUS316L stainless steel and fluororesin construction handles resist stripping environments up to 70°C. Longer sensing range from mounting hole (32~44mm) provides flexible installation options. Non-contact detection with high resistance to chemical splatter. Free-cut compatible. Amplifier (E3X series) sold separately. Standard object: glass (t=0.7mm). Sensing distance: 8~20mm from lens tip (recommended 11mm); 32~44mm from mounting hole A center (recommended 35mm). Material: SUS316L + Fluororesin (PFA). Protection: IP67 @ 70°C. Min. bending radius: R40 mm. Compliant with CE marking. Applications: Resist Stripping (longer mounting distance).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-L12FS 2M | OMRON E32-L12FS fiber optic sensor head, SUS316L body, 2m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 32~44mm from mounting hole A center (recommended 35mm) | Cable Length: 2m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: SUS316L + Fluororesin (PFA) | Protection: IP67 @ 70°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Resist Stripping (longer mounting distance) | |
| E32-L12FS 5M | OMRON E32-L12FS fiber optic sensor head, SUS316L body, 5m pre-wired cable, IP67. | OMRON | Sensing Method: Limited-reflective fiber optic | Standard Object: Glass (t=0.7mm) | Sensing Distance (lens tip): 8~20mm from lens tip (recommended 11mm) | Sensing Distance (mounting hole A): 32~44mm from mounting hole A center (recommended 35mm) | Cable Length: 5m | Fiber Diameter: ø2.2mm | Min. Bending Radius: R40 mm | Material: SUS316L + Fluororesin (PFA) | Protection: IP67 @ 70°C | Free-cut: Supported | Connection: Pre-wired (Amplifier sold separately — E3X series) | Applications: Resist Stripping (longer mounting distance) |
OMRON E32-LD Build-in Lens Reflective Fiber Unit — General-purpose threaded fiber sensor with built-in PMMA lens. Approximately 3.5× the light intensity of conventional non-lens reflective models — stable detection even for difficult-to-detect glossy black workpieces and low-reflection materials. Sensing distance approximately 2× conventional non-lens reflective models. 15° aperture angle creates a clear, well-defined spot (approx. 80 mm at 300 mm distance vs 350 mm conventional) for easy on-site adjustment and label-through-backing detection. M6×0.75 trivalent chrome-plated zinc alloy threaded body — no external lens attachment required, no protrusion, no risk of lost lens. Free-cut supported. Two cable variants: standard R25 bending radius (E32-LD11) and flexible R1 (E32-LD11R). IP50. Operating temperature −40 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers.
OMRON E32-LD Build-in Lens Reflective Fiber Unit — General-purpose threaded fiber sensor with built-in PMMA lens. Approximately 3.5× the light intensity of conventional non-lens reflective models — stable detection even for difficult-to-detect glossy black workpieces and low-reflection materials. Sensing distance approximately 2× conventional non-lens reflective models. 15° aperture angle creates a clear, well-defined spot (approx. 80 mm at 300 mm distance vs 350 mm conventional) for easy on-site adjustment and label-through-backing detection. M6×0.75 trivalent chrome-plated zinc alloy threaded body — no external lens attachment required, no protrusion, no risk of lost lens. Free-cut supported. Two cable variants: standard R25 bending radius (E32-LD11) and flexible R1 (E32-LD11R). IP50. Operating temperature −40 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-LD11 2M | E32-LD11 2M — Build-in Lens reflective fiber unit, M6, 15° aperture, R25 bending | OMRON | Type: Build-in Lens Reflective Fiber Unit | Sensing Direction: Top-view | Mounting Thread: M6×0.75 (trivalent chrome-plated zinc alloy) | Sensing Surface: 2× 1.5 mm dia. (with built-in PMMA lens) | Min. Sensing Object (E3X-HD): 0.1 mm dia. | Min. Sensing Object (E3NX-FA): 0.03 mm dia. | Bending Radius of Cable: R25 | Unbendable Length: 10 mm | Sensing Distance — E3X-HD GIGA: 860 mm | Sensing Distance — E3X-HD HS: 250 mm | Sensing Distance — E3X-HD ST: 360 mm | Sensing Distance — E3X-HD SHS: 110 mm | Sensing Distance — E3NX-FA GIGA: 1,290 mm | Sensing Distance — E3NX-FA HS: 370 mm | Sensing Distance — E3NX-FA ST: 540 mm | Sensing Distance — E3NX-FA SHS: 110 mm | Standard Sensing Object: Glossy white paper | Black Workpiece Detection (E3X-HD): SHS 65 mm / HS 160 mm / ST 160 mm / GIGA 500 mm (50 mm glossy black plastic) | Light Intensity Advantage: Approx. 3.5× vs conventional non-lens reflective models (HS mode at 150 mm with glossy black plastic) | Spot Size Advantage: Approx. 80 mm spot at 300 mm distance (vs approx. 350 mm conventional non-lens) | Mounting: Opposite side 10 mm / Thickness 2.4 mm nickel-plated brass nuts + nickel-plated iron washers | Tightening Torque: 0.98 N·m | Weight (Packed): approx. 40 g | Aperture Angle: 15° (Build-in Lens GIGA Beam, vs conventional 60° non-lens) | Lens: Build-in (no external lens attachment required) | Degree of Protection: IP50 | Ambient Temperature: −40 to +70 °C | Cable Sheath Material: Polyethylene | Fiber Core Material: Plastic | Tensile Strength: 29.4 N | Cable Length: 2 m | Free-cut: Supported | Compatible Amplifiers: E3X-HD series / E3NX-FA series (sold separately) | Note: E3X-HD0 Communication Unit Connector model was discontinued October 2024 (per PDF) | |
| E32-LD11R 2M | E32-LD11R 2M — Build-in Lens reflective fiber unit, M6, 15° aperture, Flexible R1 bending | OMRON | Type: Build-in Lens Reflective Fiber Unit | Sensing Direction: Top-view | Mounting Thread: M6×0.75 (trivalent chrome-plated zinc alloy) | Sensing Surface: 2× 1.5 mm dia. (with built-in PMMA lens) | Min. Sensing Object (E3X-HD): 0.1 mm dia. | Min. Sensing Object (E3NX-FA): 0.03 mm dia. | Bending Radius of Cable: Flexible R1 | Unbendable Length: 0 mm | Sensing Distance — E3X-HD GIGA: 840 mm | Sensing Distance — E3X-HD HS: 240 mm | Sensing Distance — E3X-HD ST: 350 mm | Sensing Distance — E3X-HD SHS: 100 mm | Sensing Distance — E3NX-FA GIGA: 1,260 mm | Sensing Distance — E3NX-FA HS: 360 mm | Sensing Distance — E3NX-FA ST: 520 mm | Sensing Distance — E3NX-FA SHS: 100 mm | Standard Sensing Object: Glossy white paper | Black Workpiece Detection (E3X-HD): SHS 65 mm / HS 150 mm / ST 150 mm / GIGA 400 mm (50 mm glossy black plastic) | Light Intensity Advantage: Approx. 3.5× vs conventional non-lens reflective models (HS mode at 150 mm with glossy black plastic) | Spot Size Advantage: Approx. 80 mm spot at 300 mm distance (vs approx. 350 mm conventional non-lens) | Mounting: Opposite side 10 mm / Thickness 2.4 mm nickel-plated brass nuts + nickel-plated iron washers | Tightening Torque: 0.98 N·m | Weight (Packed): approx. 40 g | Aperture Angle: 15° (Build-in Lens GIGA Beam, vs conventional 60° non-lens) | Lens: Build-in (no external lens attachment required) | Degree of Protection: IP50 | Ambient Temperature: −40 to +70 °C | Cable Sheath Material: Polyethylene | Fiber Core Material: Plastic | Tensile Strength: 29.4 N | Cable Length: 2 m | Free-cut: Supported | Compatible Amplifiers: E3X-HD series / E3NX-FA series (sold separately) | Note: E3X-HD0 Communication Unit Connector model was discontinued October 2024 (per PDF) |
OMRON E32-LT Build-in Lens Through-beam Fiber Unit — General-purpose threaded fiber sensor with built-in PMMA lens. Approximately 10× the light intensity of conventional non-lens models for long-term stable detection at distances up to 4,000 mm (Giga-power mode, E3X-HD or E3NX-FA). 15° aperture angle (vs conventional 60°) prevents false detection from surrounding objects and enables stable detection in narrow workpiece spacing. M4×0.7 trivalent chrome-plated zinc alloy threaded body — no external lens attachment required, no protrusion, no risk of lost lens. Free-cut supported. Two cable variants: standard R25 bending radius (E32-LT11) and flexible R1 (E32-LT11R). IP50. Operating temperature −40 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers.
OMRON E32-LT Build-in Lens Through-beam Fiber Unit — General-purpose threaded fiber sensor with built-in PMMA lens. Approximately 10× the light intensity of conventional non-lens models for long-term stable detection at distances up to 4,000 mm (Giga-power mode, E3X-HD or E3NX-FA). 15° aperture angle (vs conventional 60°) prevents false detection from surrounding objects and enables stable detection in narrow workpiece spacing. M4×0.7 trivalent chrome-plated zinc alloy threaded body — no external lens attachment required, no protrusion, no risk of lost lens. Free-cut supported. Two cable variants: standard R25 bending radius (E32-LT11) and flexible R1 (E32-LT11R). IP50. Operating temperature −40 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-LT11 2M | E32-LT11 2M — Build-in Lens through-beam fiber unit, M4, 15° aperture, R25 bending | OMRON | Type: Build-in Lens Through-beam Fiber Unit | Sensing Direction: Top-view | Mounting Thread: M4×0.7 (trivalent chrome-plated zinc alloy) | Sensing Surface: 2.3 mm dia. (with built-in PMMA lens) | Optical Axis Diameter: 2.3 mm dia. | Min. Sensing Object (E3X-HD): 0.1 mm dia. | Min. Sensing Object (E3NX-FA): 0.03 mm dia. | Bending Radius of Cable: R25 | Unbendable Length: 10 mm | Sensing Distance — E3X-HD GIGA: 4,000 mm | Sensing Distance — E3X-HD HS: 4,000 mm | Sensing Distance — E3X-HD ST: 4,000 mm | Sensing Distance — E3X-HD SHS: 2,700 mm | Sensing Distance — E3NX-FA GIGA: 4,000 mm | Sensing Distance — E3NX-FA HS: 4,000 mm | Sensing Distance — E3NX-FA ST: 4,000 mm | Sensing Distance — E3NX-FA SHS: 1,080 mm | Light Intensity Advantage: Approx. 10× vs conventional non-lens through-beam models (HS mode at 1 m) | Mounting: Opposite side 7 mm / Thickness 2.4 mm nickel-plated brass nuts + nickel-plated iron washers | Tightening Torque: 0.78 N·m | Cable Configuration: 2 m on each side (4,000 mm total sensing path) | Emitter/Receiver Differentiation: None (interchangeable) | Weight (Packed): approx. 40 g | Aperture Angle: 15° (Build-in Lens GIGA Beam, vs conventional 60° non-lens) | Lens: Build-in (no external lens attachment required) | Degree of Protection: IP50 | Ambient Temperature: −40 to +70 °C | Cable Sheath Material: Polyethylene | Fiber Core Material: Plastic | Tensile Strength: 29.4 N | Cable Length: 2 m | Free-cut: Supported | Compatible Amplifiers: E3X-HD series / E3NX-FA series (sold separately) | Note: E3X-HD0 Communication Unit Connector model was discontinued October 2024 (per PDF) | |
| E32-LT11R 2M | E32-LT11R 2M — Build-in Lens through-beam fiber unit, M4, 15° aperture, Flexible R1 bending | OMRON | Type: Build-in Lens Through-beam Fiber Unit | Sensing Direction: Top-view | Mounting Thread: M4×0.7 (trivalent chrome-plated zinc alloy) | Sensing Surface: 2.3 mm dia. (with built-in PMMA lens) | Optical Axis Diameter: 2.3 mm dia. | Min. Sensing Object (E3X-HD): 0.1 mm dia. | Min. Sensing Object (E3NX-FA): 0.03 mm dia. | Bending Radius of Cable: Flexible R1 | Unbendable Length: 0 mm | Sensing Distance — E3X-HD GIGA: 4,000 mm | Sensing Distance — E3X-HD HS: 3,500 mm | Sensing Distance — E3X-HD ST: 2,300 mm | Sensing Distance — E3X-HD SHS: 920 mm | Sensing Distance — E3NX-FA GIGA: 4,000 mm | Sensing Distance — E3NX-FA HS: 3,450 mm | Sensing Distance — E3NX-FA ST: 4,000 mm | Sensing Distance — E3NX-FA SHS: 920 mm | Light Intensity Advantage: Approx. 10× vs conventional non-lens through-beam models (HS mode at 1 m) | Mounting: Opposite side 7 mm / Thickness 2.4 mm nickel-plated brass nuts + nickel-plated iron washers | Tightening Torque: 0.78 N·m | Cable Configuration: 2 m on each side (4,000 mm total sensing path) | Emitter/Receiver Differentiation: None (interchangeable) | Weight (Packed): approx. 40 g | Aperture Angle: 15° (Build-in Lens GIGA Beam, vs conventional 60° non-lens) | Lens: Build-in (no external lens attachment required) | Degree of Protection: IP50 | Ambient Temperature: −40 to +70 °C | Cable Sheath Material: Polyethylene | Fiber Core Material: Plastic | Tensile Strength: 29.4 N | Cable Length: 2 m | Free-cut: Supported | Compatible Amplifiers: E3X-HD series / E3NX-FA series (sold separately) | Note: E3X-HD0 Communication Unit Connector model was discontinued October 2024 (per PDF) |
OMRON E32-T11NF Oil-resistant Fiber Unit — Environment-resistant Series. Through-beam type with right-angle sensing direction. Fluororesin cable covering (fiber covering) prevents cutting oil ingress into the fiber core. Mechanical seal structure: aluminum ring bushing compressed by set screw against fluororesin core. Spherical glass lens resists oil adhesion; shape prevents accumulation of oil drops and cutting chips. IP68G degree of protection (JIS C 0920 Annex 1). Operating temperature −25 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers (amplifiers themselves are not oil-resistant). Two mounting sizes: M8 (E32-T11NF) and M4 (E32-T11NFS, for limited-space applications).
OMRON E32-T11NF Oil-resistant Fiber Unit — Environment-resistant Series. Through-beam type with right-angle sensing direction. Fluororesin cable covering (fiber covering) prevents cutting oil ingress into the fiber core. Mechanical seal structure: aluminum ring bushing compressed by set screw against fluororesin core. Spherical glass lens resists oil adhesion; shape prevents accumulation of oil drops and cutting chips. IP68G degree of protection (JIS C 0920 Annex 1). Operating temperature −25 to +70 °C. Compatible with E3X-HD and E3NX-FA fiber amplifiers (amplifiers themselves are not oil-resistant). Two mounting sizes: M8 (E32-T11NF) and M4 (E32-T11NFS, for limited-space applications).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E32-T11NF 2M | E32-T11NF 2M — through-beam right-angle fiber unit, M8 | OMRON | Type: Oil-resistant Through-beam Fiber Unit | Sensing Direction: Right-angle | Mounting Size: M8 | Sensing Distance: GIGA 4,000 mm / ST 4,000 mm / HS 4,000 mm / SHS 2,200 mm (E3X-HD); same in E3NX-FA | Optical Axis Diameter (Min. Sensing Object): 4 mm dia. (min. sensing object 0.1 mm dia. E3X-HD / 0.03 mm dia. E3NX-FA) | Bending Radius of Cable: Flexible R1 | Unbendable Length: 0 mm | Tensile Strength: 29.4 N | Cable Sheath Material: Fluororesin | Fiber Core Material: Plastic | Emitter/Receiver Differentiation: None (interchangeable) | Lens: Spherical glass (resists oil adhesion) | Mounting: 8.5 mm dia. mounting hole / Tightening torque 12 N·m | Ambient Temperature: −25 to +70 °C | Weight (Packed): approx. 80 g | Degree of Protection: IP68 (IEC 60529) + IP68G (JIS C 0920 Annex 1) | Sealing Method: Mechanical seal (aluminum ring bushing compressed by set screw against fluororesin) | Compatible Amplifiers: E3X-HD series / E3NX-FA series (amplifiers not oil-resistant) | Response Time (with E3X-HD): SHS 50 μs (NPN) or 55 μs (PNP) / HS 250 μs / ST 1 ms / GIGA 16 ms | Response Time (with E3NX-FA): SHS 30 μs / HS 250 μs / ST 1 ms / GIGA 16 ms | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max | |
| E32-T11NFS 2M | E32-T11NFS 2M — through-beam right-angle fiber unit, M4 (limited space) | OMRON | Type: Oil-resistant Through-beam Fiber Unit | Sensing Direction: Right-angle | Mounting Size: M4 (limited space) | Sensing Distance: GIGA 2,200 mm / ST 1,100 mm / HS 730 mm / SHS 270 mm (E3X-HD); GIGA 3,300 mm / ST 1,600 mm / HS 1,100 mm / SHS 270 mm (E3NX-FA) | Optical Axis Diameter (Min. Sensing Object): 2 mm dia. (min. sensing object 0.1 mm dia. E3X-HD / 0.03 mm dia. E3NX-FA) | Bending Radius of Cable: Flexible R1 | Unbendable Length: 0 mm | Tensile Strength: 29.4 N | Cable Sheath Material: Fluororesin | Fiber Core Material: Plastic | Emitter/Receiver Differentiation: None (interchangeable) | Lens: Spherical glass (resists oil adhesion) | Mounting: 4.2 mm dia. mounting hole / Tightening torque 0.78 N·m | Ambient Temperature: −25 to +70 °C | Weight (Packed): approx. 70 g | Degree of Protection: IP68 (IEC 60529) + IP68G (JIS C 0920 Annex 1) | Sealing Method: Mechanical seal (aluminum ring bushing compressed by set screw against fluororesin) | Compatible Amplifiers: E3X-HD series / E3NX-FA series (amplifiers not oil-resistant) | Response Time (with E3X-HD): SHS 50 μs (NPN) or 55 μs (PNP) / HS 250 μs / ST 1 ms / GIGA 16 ms | Response Time (with E3NX-FA): SHS 30 μs / HS 250 μs / ST 1 ms / GIGA 16 ms | Oil Resistance: 4 years (verified by OMRON's accelerated evaluation tests) | Cable Sheath: Fluororesin (patent pending) — resists both water-soluble and water-insoluble cutting oils | Evaluation Standard: Passed IP67G (JIS C 0920 Annex 1) and OMRON's Oil-resistant Component Evaluation Standards | Applicable Oil Types: JIS K 2241:2000 specified cutting oils | Evaluation Temperature: 35 °C max |
Communications-type color fiber amplifier for connection to OMRON E3NW-ECT (EtherCAT) or E3NW-DS (Distributed Unit) Sensor Communications Unit, enabling real-time RGB data transmission to PLC and upper-level systems. Quantifies packaging color variation (0~9999 RGB values) for database management and lot-to-lot analysis — solve color drift issues before they cause false detections. Test setting support function: feed designed RGB values back to designers for printability validation, reducing design-to-production lead time. Same white LED + RGB matrix sensor as standard E3NX-CA. Power supplied through E3NW unit. ⚠️ Only E3NW-ECT (EtherCAT) and E3NW-DS (Distributed) supported — E3NW-CRT (CompoNet) and E3NW-CCL (CC-Link) NOT compatible. Compatible with OMRON E32 series fiber heads. E3NW Sensor Communications Unit sold separately — contact for quote.
Communications-type color fiber amplifier for connection to OMRON E3NW-ECT (EtherCAT) or E3NW-DS (Distributed Unit) Sensor Communications Unit, enabling real-time RGB data transmission to PLC and upper-level systems. Quantifies packaging color variation (0~9999 RGB values) for database management and lot-to-lot analysis — solve color drift issues before they cause false detections. Test setting support function: feed designed RGB values back to designers for printability validation, reducing design-to-production lead time. Same white LED + RGB matrix sensor as standard E3NX-CA. Power supplied through E3NW unit. ⚠️ Only E3NW-ECT (EtherCAT) and E3NW-DS (Distributed) supported — E3NW-CRT (CompoNet) and E3NW-CCL (CC-Link) NOT compatible. Compatible with OMRON E32 series fiber heads. E3NW Sensor Communications Unit sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-CA0 | OMRON E3NX-CA0 communications color fiber amplifier, white LED, for E3NW-ECT (EtherCAT) or E3NW-DS Sensor Communications Unit. | OMRON | Output: Communications-only (no direct output, network-assigned) | I/O Configuration: Communications connector type | Connection: Communications connector — requires E3NW-ECT (EtherCAT) or E3NW-DS (Distributed Unit) sold separately. NOT compatible with E3NW-CRT or E3NW-CCL. | Power Supply: Supplied via E3NW Sensor Communications Unit | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT, 0.2ms I/O cycle) or E3NW-DS (Distributed Unit) | Compatibility Note: ⚠️ E3NW-CRT (CompoNet) and E3NW-CCL (CC-Link) NOT compatible with E3NX-CA. Only E3NW-ECT and E3NW-DS supported. | RGB Data Transmission: 0~9999 RGB values transmitted via EtherCAT for upper-level data management — visualize color variation across packaging lots, database integration for optimal threshold setting and root-cause analysis | Output Mode: 2 sensor outputs assigned via network — settings change/reading via PLC | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Application Notes: Industry 4.0 smart factory: real-time color data logging, lot-to-lot variation tracking, predictive maintenance via RGB drift analysis, recipe management from PLC/HMI | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
[OMRON] — E3NX-CA High-Function Color Fiber Amplifier (Multi-Output + External Input, AND/OR Logic)
▶High-function color fiber amplifier with 2 outputs, 1 external input, and AND/OR logic output for advanced color detection applications. White LED + RGB matrix sensor with 4x dynamic range and 4x S/N improvement vs E3X-DAC-S. External input enables remote tuning, Light OFF, Zero Reset, and BANK switching (1~8) — useful for production line recipe changeover or remote troubleshooting. AND/OR logic combines OUT1 and OUT2 channels for complex pass/fail criteria (e.g., color match + count threshold simultaneously). Output 2 supports Error output mode for self-diagnostic alarms. Smart Tuning, four response modes (SHS 50μs ~ GIGA 16ms), BANK 1~8. 10-30 VDC, NPN or PNP. Compatible with OMRON E32 series fiber heads (E32-C91N coaxial recommended for color detection on tilted glossy workpieces). Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
High-function color fiber amplifier with 2 outputs, 1 external input, and AND/OR logic output for advanced color detection applications. White LED + RGB matrix sensor with 4x dynamic range and 4x S/N improvement vs E3X-DAC-S. External input enables remote tuning, Light OFF, Zero Reset, and BANK switching (1~8) — useful for production line recipe changeover or remote troubleshooting. AND/OR logic combines OUT1 and OUT2 channels for complex pass/fail criteria (e.g., color match + count threshold simultaneously). Output 2 supports Error output mode for self-diagnostic alarms. Smart Tuning, four response modes (SHS 50μs ~ GIGA 16ms), BANK 1~8. 10-30 VDC, NPN or PNP. Compatible with OMRON E32 series fiber heads (E32-C91N coaxial recommended for color detection on tilted glossy workpieces). Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-CA21 2M | OMRON E3NX-CA21 high-function color fiber amplifier, NPN, 2-output + 1-input, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable, 4 dia., 5 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Output 2 Mode: Standard / Error output / AND output / OR output | External Input Functions: Input OFF / Tuning / Full Auto Tuning / Light OFF / BANK1-2 switching / BANK1-8 switching / Zero Reset | External Input Specs (NPN type): Contact: ON=0V short (sink ≤2mA) / OFF=open or Vcc short. Transistor: ON ≤1.5V (sink ≤2mA) / OFF=Vcc-1.5V~Vcc (leak ≤0.1mA) | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-CA51 2M | OMRON E3NX-CA51 high-function color fiber amplifier, PNP, 2-output + 1-input, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable, 4 dia., 5 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Output 2 Mode: Standard / Error output / AND output / OR output | External Input Functions: Input OFF / Tuning / Full Auto Tuning / Light OFF / BANK1-2 switching / BANK1-8 switching / Zero Reset | External Input Specs (NPN type): Contact: ON=0V short (sink ≤2mA) / OFF=open or Vcc short. Transistor: ON ≤1.5V (sink ≤2mA) / OFF=Vcc-1.5V~Vcc (leak ≤0.1mA) | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
Standard-type color fiber amplifier with white LED and patented RGB matrix sensor for stable color mark detection on glossy aluminum-vapor-deposited packaging, colorful packaging with subtle color differences, and packaging with lot-to-lot color variation. Smart Tuning configures optimum settings with two button presses (with workpiece + without workpiece). 4x improved dynamic range vs E3X-DAC-S — no saturation even on optical mirror surfaces (99% reflectivity). 4x S/N ratio improvement via Smart Noise Reduction algorithm for subtle color difference detection. Color Mode discriminates RGB ratios; Contrast Mode discriminates RGB single-channel intensity. 11 standard color discrimination (white/red/yellow-red/yellow/yellow-green/green/blue-green/blue/blue-violet/violet/magenta) plus black. BANK 1~8 selectable, four response modes (SHS 50μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP open-collector. Up to 30 units gang-mounted. Compatible with OMRON E32 series fiber heads — recommended E32-C91N (M6 coaxial reflective) for color detection on tilted glossy workpieces. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave), Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
Standard-type color fiber amplifier with white LED and patented RGB matrix sensor for stable color mark detection on glossy aluminum-vapor-deposited packaging, colorful packaging with subtle color differences, and packaging with lot-to-lot color variation. Smart Tuning configures optimum settings with two button presses (with workpiece + without workpiece). 4x improved dynamic range vs E3X-DAC-S — no saturation even on optical mirror surfaces (99% reflectivity). 4x S/N ratio improvement via Smart Noise Reduction algorithm for subtle color difference detection. Color Mode discriminates RGB ratios; Contrast Mode discriminates RGB single-channel intensity. 11 standard color discrimination (white/red/yellow-red/yellow/yellow-green/green/blue-green/blue/blue-violet/violet/magenta) plus black. BANK 1~8 selectable, four response modes (SHS 50μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP open-collector. Up to 30 units gang-mounted. Compatible with OMRON E32 series fiber heads — recommended E32-C91N (M6 coaxial reflective) for color detection on tilted glossy workpieces. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave), Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-CA11 2M | OMRON E3NX-CA11 standard color fiber amplifier, NPN, 1-output, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Pre-wired (2m cable, 4 dia., 3 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-CA41 2M | OMRON E3NX-CA41 standard color fiber amplifier, PNP, 1-output, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Pre-wired (2m cable, 4 dia., 3 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-CA6 | OMRON E3NX-CA6 standard color fiber amplifier, NPN, 1-output, wire-saving. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-CA8 | OMRON E3NX-CA8 standard color fiber amplifier, PNP, 1-output, wire-saving. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 720mW (30mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 50 μs (Contrast Mode only) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Light Source: White LED (420~700 nm) — wide spectral range for color sensing | Light Receiving Element: High-sensitivity RGB matrix sensor (patented technology) | Detection Modes: Contrast Mode (RGB single-channel intensity discrimination after 2-point tuning) / Color Mode (RGB ratio discrimination) | Display: 7-segment digital display — sub digital (green) + main digital (white) | Indicators: OUT (orange), L/D (orange), ST (blue, smart tuning), OUT2 select (orange, 2-output models) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / 1-point tuning (1%~99%)] or Manual | Operation Mode: Contrast Mode: NO (light ON) / NC (dark ON). Color Mode: NO (color match ON) / NC (color mismatch ON) | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (0.1~5000ms range, 0.1ms unit) | Bank Switching: BANK 1~8 selectable (more than E3NX-FA's BANK 1~4) | Power Tuning Level: 100~9999 settable | Zero Reset: Contrast Mode only (with negative display) | Setting Reset: Initial reset / User reset / BANK reset | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled. | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series — recommended: E32-C91N (M6 coaxial reflective, 60° aperture for color detection on tilted glossy workpieces) and E32-G16 (10mm area beam, slot type) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
Analog output smart fiber amplifier providing both digital open-collector and analog signal (4-20mA or 0-5V selectable) outputs simultaneously — ideal for continuous-quantity monitoring such as thread/sheet thickness measurement, position feedback to PLC analog inputs, and real-time process variation detection. Same GIGA RAY2S light source and Smart Tuning as standard E3NX-FA. Solution Viewer for workpiece visualization. Four response modes (SHS 32μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP digital output. APC + DPC auto-compensation. White 7-segment display. Compatible with OMRON E32 series fiber optic heads. Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
Analog output smart fiber amplifier providing both digital open-collector and analog signal (4-20mA or 0-5V selectable) outputs simultaneously — ideal for continuous-quantity monitoring such as thread/sheet thickness measurement, position feedback to PLC analog inputs, and real-time process variation detection. Same GIGA RAY2S light source and Smart Tuning as standard E3NX-FA. Solution Viewer for workpiece visualization. Four response modes (SHS 32μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP digital output. APC + DPC auto-compensation. White 7-segment display. Compatible with OMRON E32 series fiber optic heads. Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-FA11AN 2M | OMRON E3NX-FA11AN analog output smart fiber amplifier, NPN digital + analog (4-20mA / 0-5V), 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 2 outputs (digital + analog) | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Approx. 920mW max. (analog output type) | Control Output: NPN or PNP open-collector (digital) + Analog output, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | Output Configuration: 2 outputs: 1× digital open-collector + 1× analog (4-20mA or 0-5V selectable) | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Application Notes: Continuous-quantity monitoring applications: thread/sheet thickness measurement, position feedback to PLC analog inputs, transparent material thickness variations, SPC data logging | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA41AN 2M | OMRON E3NX-FA41AN analog output smart fiber amplifier, PNP digital + analog (4-20mA / 0-5V), 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 2 outputs (digital + analog) | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Approx. 920mW max. (analog output type) | Control Output: NPN or PNP open-collector (digital) + Analog output, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | Output Configuration: 2 outputs: 1× digital open-collector + 1× analog (4-20mA or 0-5V selectable) | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Application Notes: Continuous-quantity monitoring applications: thread/sheet thickness measurement, position feedback to PLC analog inputs, transparent material thickness variations, SPC data logging | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
Communications-type smart fiber amplifier designed for connection to OMRON E3NW Sensor Communications Unit, enabling network-based sensor data management over EtherCAT, CompoNet, or CC-Link. Includes both connector-only types (FA0/FAH0) and pre-wired output types (FA10/FA40 with 1× digital open-collector). All models share GIGA RAY2S light source, Smart Tuning, Solution Viewer, and APC + DPC auto-compensation of the standard E3NX-FA. Power supplied through E3NW unit — no separate wiring required for amplifier itself. 32μs high-speed response available for network-connected sensors. Ideal for centralized factory data management, real-time diagnostics, and Industry 4.0 smart factory integration. ⚠️ Requires E3NW Sensor Communications Unit (sold separately): E3NW-ECT (EtherCAT), E3NW-CRT (CompoNet), E3NW-CCL (CC-Link), or E3NW-DS (Distributed Unit) — contact for quote. ⚠️ E3NX-FAH0 (infrared) cannot connect to E3NW-CRT. Compatible with OMRON E32 series fiber optic heads.
Communications-type smart fiber amplifier designed for connection to OMRON E3NW Sensor Communications Unit, enabling network-based sensor data management over EtherCAT, CompoNet, or CC-Link. Includes both connector-only types (FA0/FAH0) and pre-wired output types (FA10/FA40 with 1× digital open-collector). All models share GIGA RAY2S light source, Smart Tuning, Solution Viewer, and APC + DPC auto-compensation of the standard E3NX-FA. Power supplied through E3NW unit — no separate wiring required for amplifier itself. 32μs high-speed response available for network-connected sensors. Ideal for centralized factory data management, real-time diagnostics, and Industry 4.0 smart factory integration. ⚠️ Requires E3NW Sensor Communications Unit (sold separately): E3NW-ECT (EtherCAT), E3NW-CRT (CompoNet), E3NW-CCL (CC-Link), or E3NW-DS (Distributed Unit) — contact for quote. ⚠️ E3NX-FAH0 (infrared) cannot connect to E3NW-CRT. Compatible with OMRON E32 series fiber optic heads.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-FA0 | OMRON E3NX-FA0 communications smart fiber amplifier, red LED, for E3NW Sensor Communications Unit (EtherCAT/CompoNet/CC-Link). | OMRON | Output: Communications-only (no direct output) | I/O Configuration: Communications connector type (red LED 625nm) | Connection: Communications connector — requires E3NW-ECT/CRT/CCL/DS Sensor Communications Unit sold separately | Light Source — FA0/FA10/FA40: Red 4-element LED (625 nm) — GIGA RAY2S | Light Source — FAH0: Infrared LED (870 nm) — GIGA RAY2S | Power Supply: Supplied via E3NW Sensor Communications Unit | Control Output (FA10/FA40): NPN or PNP open-collector, 30 VDC max., 1 output | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT) / E3NW-CRT (CompoNet) / E3NW-CCL (CC-Link) / E3NW-DS (Distributed Unit) | Compatibility Note: E3NX-FAH0 (infrared) cannot connect to E3NW-CRT (CompoNet) | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Connection Topology: Daisy-chain via E3NW Sensor Communications Unit — provides centralized data management, parameter setting from PLC, and real-time diagnostics | Application Notes: For network-based factory automation: production data collection, remote sensor parameter management, PLC-integrated diagnostics, Industry 4.0 smart factory integration | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FAH0 | OMRON E3NX-FAH0 infrared communications smart fiber amplifier, IR LED 870nm, for E3NW Sensor Communications Unit (EtherCAT/CC-Link/Distributed only). | OMRON | Output: Communications-only (no direct output) | I/O Configuration: Communications connector type (infrared LED 870nm) — NOT compatible with E3NW-CRT | Connection: Communications connector — requires E3NW-ECT/CCL/DS Sensor Communications Unit sold separately (NOT E3NW-CRT) | Light Source — FA0/FA10/FA40: Red 4-element LED (625 nm) — GIGA RAY2S | Light Source — FAH0: Infrared LED (870 nm) — GIGA RAY2S | Power Supply: Supplied via E3NW Sensor Communications Unit | Control Output (FA10/FA40): NPN or PNP open-collector, 30 VDC max., 1 output | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT) / E3NW-CRT (CompoNet) / E3NW-CCL (CC-Link) / E3NW-DS (Distributed Unit) | Compatibility Note: E3NX-FAH0 (infrared) cannot connect to E3NW-CRT (CompoNet) | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Connection Topology: Daisy-chain via E3NW Sensor Communications Unit — provides centralized data management, parameter setting from PLC, and real-time diagnostics | Application Notes: For network-based factory automation: production data collection, remote sensor parameter management, PLC-integrated diagnostics, Industry 4.0 smart factory integration | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA10 2M | OMRON E3NX-FA10 communications smart fiber amplifier, NPN 1-output, 2m pre-wired, for E3NW Sensor Communications Unit. | OMRON | Output: NPN | I/O Configuration: 1 output + Communications | Connection: Communications connector + 2m pre-wired output cable — requires E3NW-ECT/CRT/CCL/DS Sensor Communications Unit sold separately | Light Source — FA0/FA10/FA40: Red 4-element LED (625 nm) — GIGA RAY2S | Light Source — FAH0: Infrared LED (870 nm) — GIGA RAY2S | Power Supply: Supplied via E3NW Sensor Communications Unit | Control Output (FA10/FA40): NPN or PNP open-collector, 30 VDC max., 1 output | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT) / E3NW-CRT (CompoNet) / E3NW-CCL (CC-Link) / E3NW-DS (Distributed Unit) | Compatibility Note: E3NX-FAH0 (infrared) cannot connect to E3NW-CRT (CompoNet) | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Connection Topology: Daisy-chain via E3NW Sensor Communications Unit — provides centralized data management, parameter setting from PLC, and real-time diagnostics | Application Notes: For network-based factory automation: production data collection, remote sensor parameter management, PLC-integrated diagnostics, Industry 4.0 smart factory integration | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA40 2M | OMRON E3NX-FA40 communications smart fiber amplifier, PNP 1-output, 2m pre-wired, for E3NW Sensor Communications Unit. | OMRON | Output: PNP | I/O Configuration: 1 output + Communications | Connection: Communications connector + 2m pre-wired output cable — requires E3NW-ECT/CRT/CCL/DS Sensor Communications Unit sold separately | Light Source — FA0/FA10/FA40: Red 4-element LED (625 nm) — GIGA RAY2S | Light Source — FAH0: Infrared LED (870 nm) — GIGA RAY2S | Power Supply: Supplied via E3NW Sensor Communications Unit | Control Output (FA10/FA40): NPN or PNP open-collector, 30 VDC max., 1 output | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT) / E3NW-CRT (CompoNet) / E3NW-CCL (CC-Link) / E3NW-DS (Distributed Unit) | Compatibility Note: E3NX-FAH0 (infrared) cannot connect to E3NW-CRT (CompoNet) | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Connection Topology: Daisy-chain via E3NW Sensor Communications Unit — provides centralized data management, parameter setting from PLC, and real-time diagnostics | Application Notes: For network-based factory automation: production data collection, remote sensor parameter management, PLC-integrated diagnostics, Industry 4.0 smart factory integration | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
High-function smart fiber amplifier with multi-output (2-output), external input, and IO-Link variants for advanced industrial automation. GIGA RAY2S light source delivers 1.5x sensing distance vs E3X-HD. Smart Tuning with 40,000x light intensity range provides stable detection even with saturated incident light. Solution Viewer + Change Finder visualize workpiece transit time and high-speed values. External input enables remote tuning, BANK switching, zero reset, and more. Output 2 modes include Alarm output, Error output, and Differential detection. ⭐ NEW: IO-Link Class 2 models (E3NX-FA51-IL3, E3NX-FA54-IL3) with Smart Verify alarm function for preventive maintenance — alerts on parameter changes or unintended operation. White 7-segment display, BANK 1~4 selectable, four response modes (SHS 30μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP. APC + DPC auto-compensation. Compatible with OMRON E32 series fiber optic heads. M8 connector models compatible with XS3F-M421/M422 cables (separately listed). Wire-saving Connectors (E3X-CN21 Master 4-conductor / E3X-CN22 Slave 2-conductor — different from standard FA6/FA8 connectors), Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
High-function smart fiber amplifier with multi-output (2-output), external input, and IO-Link variants for advanced industrial automation. GIGA RAY2S light source delivers 1.5x sensing distance vs E3X-HD. Smart Tuning with 40,000x light intensity range provides stable detection even with saturated incident light. Solution Viewer + Change Finder visualize workpiece transit time and high-speed values. External input enables remote tuning, BANK switching, zero reset, and more. Output 2 modes include Alarm output, Error output, and Differential detection. ⭐ NEW: IO-Link Class 2 models (E3NX-FA51-IL3, E3NX-FA54-IL3) with Smart Verify alarm function for preventive maintenance — alerts on parameter changes or unintended operation. White 7-segment display, BANK 1~4 selectable, four response modes (SHS 30μs ~ GIGA 16ms). 10-30 VDC, NPN or PNP. APC + DPC auto-compensation. Compatible with OMRON E32 series fiber optic heads. M8 connector models compatible with XS3F-M421/M422 cables (separately listed). Wire-saving Connectors (E3X-CN21 Master 4-conductor / E3X-CN22 Slave 2-conductor — different from standard FA6/FA8 connectors), Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-FA21 2M | OMRON E3NX-FA21 high-function smart fiber amplifier, NPN, 2-output + 1-input, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA51 2M | OMRON E3NX-FA51 high-function smart fiber amplifier, PNP, 2-output + 1-input, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 2 outputs + 1 input | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA51-IL3 2M | OMRON E3NX-FA51-IL3 high-function smart fiber amplifier, PNP, IO-Link Class 2, Smart Verify function, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: IO-Link Class 2 (input/output) ⭐ NEW | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA7 | OMRON E3NX-FA7 high-function smart fiber amplifier, NPN, 1-output + 1-input, wire-saving. | OMRON | Output: NPN | I/O Configuration: 1 output + 1 input | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA9 | OMRON E3NX-FA9 high-function smart fiber amplifier, PNP, 1-output + 1-input, wire-saving. | OMRON | Output: PNP | I/O Configuration: 1 output + 1 input | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA7TW | OMRON E3NX-FA7TW high-function smart fiber amplifier, NPN, 2-output, wire-saving. | OMRON | Output: NPN | I/O Configuration: 2 outputs | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA9TW | OMRON E3NX-FA9TW high-function smart fiber amplifier, PNP, 2-output, wire-saving. | OMRON | Output: PNP | I/O Configuration: 2 outputs | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA24 | OMRON E3NX-FA24 high-function smart fiber amplifier, NPN, 1-output + 1-input, M8 connector. | OMRON | Output: NPN | I/O Configuration: 1 output + 1 input | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA54 | OMRON E3NX-FA54 high-function smart fiber amplifier, PNP, 1-output + 1-input, M8 connector. | OMRON | Output: PNP | I/O Configuration: 1 output + 1 input | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA54TW | OMRON E3NX-FA54TW high-function smart fiber amplifier, PNP, 2-output, M8 connector. | OMRON | Output: PNP | I/O Configuration: 2 outputs | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA54-IL3 | OMRON E3NX-FA54-IL3 high-function smart fiber amplifier, PNP, IO-Link Class 2, Smart Verify function, M8 connector. | OMRON | Output: PNP | I/O Configuration: IO-Link Class 2 (input/output) ⭐ NEW | Connection: M8 4-pin connector — Compatible XS3F cables (separately listed): XS3F-M421-402-A/M421-405-A (straight), XS3F-M422-402-A/M422-405-A (L-shaped) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 920mW max. (38mA @ 24VDC) | ECO ON: 680mW (28mA) | ECO LO: 800mW (33mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed, 1-output): 30 μs | Response Time — SHS (Super-high-speed, 2-output): 32 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Output 2 Mode (2-output models): Standard detection / Alarm output / Error output / Differential detection | External Input Functions: Input OFF / Tuning / Power Tuning / Light Off / Sensor Off / Zero Reset / BANK switching | Smart Verify (IO-Link models only): Alarm output for parameter changes and unintended operation — preventive maintenance | IO-Link Compatibility (FA51-IL3, FA54-IL3): IO-Link Class 2 — compatible with OMRON GD series IO-Link Master Units and other vendors | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported | Setting Reset: Initial reset / User reset | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
Standard-type smart fiber amplifier with GIGA RAY2S light source delivering 1.5x sensing distance and 1/10 minimum detectable object size compared to E3X-HD. Smart Tuning offers 40,000x light intensity adjustment range — stable detection even under saturated incident conditions. White 7-segment display improves visibility. Solution Viewer shows workpiece transit time and Change Finder displays high-speed workpiece values for stable monitoring. Smart Noise Reduction (2.5x S/N improvement) plus N-Core IC (2x processing speed) for high-precision detection. Four selectable response modes from Super-high-speed (30μs) to Giga-power (16ms). 10-30 VDC, NPN or PNP open-collector output. APC + DPC auto-compensation for maintenance-free operation. Up to 30 units gang-mounted with mutual interference prevention (10 units). Compatible with OMRON E32 series fiber optic head units. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave), Mounting Bracket (E39-L143), DIN Track (PFP-100N/50N/100N2), End Plate (PFP-M), and Cover (E39-G25) sold separately — contact for quote.
Standard-type smart fiber amplifier with GIGA RAY2S light source delivering 1.5x sensing distance and 1/10 minimum detectable object size compared to E3X-HD. Smart Tuning offers 40,000x light intensity adjustment range — stable detection even under saturated incident conditions. White 7-segment display improves visibility. Solution Viewer shows workpiece transit time and Change Finder displays high-speed workpiece values for stable monitoring. Smart Noise Reduction (2.5x S/N improvement) plus N-Core IC (2x processing speed) for high-precision detection. Four selectable response modes from Super-high-speed (30μs) to Giga-power (16ms). 10-30 VDC, NPN or PNP open-collector output. APC + DPC auto-compensation for maintenance-free operation. Up to 30 units gang-mounted with mutual interference prevention (10 units). Compatible with OMRON E32 series fiber optic head units. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave), Mounting Bracket (E39-L143), DIN Track (PFP-100N/50N/100N2), End Plate (PFP-M), and Cover (E39-G25) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-FA11 2M | OMRON E3NX-FA11 standard smart fiber amplifier, NPN, 1-output, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 840mW max. (35mA @ 24VDC) | ECO ON: 650mW (27mA) | ECO LO: 750mW (31mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs (1-output models) | Response Time — SHS2 (E3NX-FA11-5 only): 60 μs (mutual interference prevention up to 2 units) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported (sift detection value) | Setting Reset: Initial reset (factory state) / User reset (saved state) | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA41 2M | OMRON E3NX-FA41 standard smart fiber amplifier, PNP, 1-output, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 840mW max. (35mA @ 24VDC) | ECO ON: 650mW (27mA) | ECO LO: 750mW (31mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs (1-output models) | Response Time — SHS2 (E3NX-FA11-5 only): 60 μs (mutual interference prevention up to 2 units) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported (sift detection value) | Setting Reset: Initial reset (factory state) / User reset (saved state) | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA11-5 2M | OMRON E3NX-FA11-5 standard smart fiber amplifier, NPN, 1-output, SHS2 high-speed mode with 2-unit mutual interference prevention, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 1 output (SHS2 mode — 2-unit mutual interference prevention) | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 840mW max. (35mA @ 24VDC) | ECO ON: 650mW (27mA) | ECO LO: 750mW (31mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs (1-output models) | Response Time — SHS2 (E3NX-FA11-5 only): 60 μs (mutual interference prevention up to 2 units) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported (sift detection value) | Setting Reset: Initial reset (factory state) / User reset (saved state) | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA6 | OMRON E3NX-FA6 standard smart fiber amplifier, NPN, 1-output, wire-saving connector. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 840mW max. (35mA @ 24VDC) | ECO ON: 650mW (27mA) | ECO LO: 750mW (31mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs (1-output models) | Response Time — SHS2 (E3NX-FA11-5 only): 60 μs (mutual interference prevention up to 2 units) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported (sift detection value) | Setting Reset: Initial reset (factory state) / User reset (saved state) | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FA8 | OMRON E3NX-FA8 standard smart fiber amplifier, PNP, 1-output, wire-saving connector. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Light Source: Red 4-element LED (625 nm) — GIGA RAY2S | Power Consumption: Normal: 840mW max. (35mA @ 24VDC) | ECO ON: 650mW (27mA) | ECO LO: 750mW (31mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs (1-output models) | Response Time — SHS2 (E3NX-FA11-5 only): 60 μs (mutual interference prevention up to 2 units) | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Zero Reset: Supported (sift detection value) | Setting Reset: Initial reset (factory state) / User reset (saved state) | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
Infrared smart fiber amplifier with 870nm IR LED for transparent and colored object detection where visible-light sensors struggle — silicon wafer presence detection, anti-light-interference applications, and detection through colored films. Same Smart Tuning and dual-display visibility as standard E3NX-FA. GIGA RAY2S light source for stable detection. Smart Noise Reduction + N-Core IC. Four response modes (SHS 30μs ~ GIGA 16ms). White 7-segment display. APC + DPC auto-compensation. 10-30 VDC, NPN or PNP. Up to 30 units gang-mounted with mutual interference prevention. Compatible with OMRON E32 series fiber optic heads. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave — same as standard FA6/FA8), Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
Infrared smart fiber amplifier with 870nm IR LED for transparent and colored object detection where visible-light sensors struggle — silicon wafer presence detection, anti-light-interference applications, and detection through colored films. Same Smart Tuning and dual-display visibility as standard E3NX-FA. GIGA RAY2S light source for stable detection. Smart Noise Reduction + N-Core IC. Four response modes (SHS 30μs ~ GIGA 16ms). White 7-segment display. APC + DPC auto-compensation. 10-30 VDC, NPN or PNP. Up to 30 units gang-mounted with mutual interference prevention. Compatible with OMRON E32 series fiber optic heads. Wire-saving Connectors (E3X-CN11 Master / E3X-CN12 Slave — same as standard FA6/FA8), Mounting Bracket (E39-L143), DIN Track, End Plate, Cover sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-FAH11 2M | OMRON E3NX-FAH11 infrared smart fiber amplifier, NPN, 1-output, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Pre-wired (2m cable) | Light Source: Infrared LED (870 nm) — GIGA RAY2S | Power Consumption: Normal: 1080mW max. (45mA @ 24VDC) | ECO ON: 920mW (38mA) | ECO LO: 1020mW (42mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Application Notes: Infrared 870nm wavelength for transparent/colored object detection, anti-light-interference applications, and silicon wafer detection | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FAH41 2M | OMRON E3NX-FAH41 infrared smart fiber amplifier, PNP, 1-output, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Pre-wired (2m cable) | Light Source: Infrared LED (870 nm) — GIGA RAY2S | Power Consumption: Normal: 1080mW max. (45mA @ 24VDC) | ECO ON: 920mW (38mA) | ECO LO: 1020mW (42mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Application Notes: Infrared 870nm wavelength for transparent/colored object detection, anti-light-interference applications, and silicon wafer detection | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FAH6 | OMRON E3NX-FAH6 infrared smart fiber amplifier, NPN, 1-output, wire-saving. | OMRON | Output: NPN | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Light Source: Infrared LED (870 nm) — GIGA RAY2S | Power Consumption: Normal: 1080mW max. (45mA @ 24VDC) | ECO ON: 920mW (38mA) | ECO LO: 1020mW (42mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Application Notes: Infrared 870nm wavelength for transparent/colored object detection, anti-light-interference applications, and silicon wafer detection | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3NX-FAH8 | OMRON E3NX-FAH8 infrared smart fiber amplifier, PNP, 1-output, wire-saving. | OMRON | Output: PNP | I/O Configuration: 1 output | Connection: Wire-saving connector — E3X-CN11 Master (3-conductor) / E3X-CN12 Slave (1-conductor) sold separately | Light Source: Infrared LED (870 nm) — GIGA RAY2S | Power Consumption: Normal: 1080mW max. (45mA @ 24VDC) | ECO ON: 920mW (38mA) | ECO LO: 1020mW (42mA) | Control Output: NPN or PNP open-collector, 30 VDC max. | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4+ amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 30 μs | Response Time — HS (High-speed): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Hysteresis: Standard or User-set (0~9999 range) | Application Notes: Infrared 870nm wavelength for transparent/colored object detection, anti-light-interference applications, and silicon wafer detection | Display: 7-segment digital display (white) — sub digital + main digital, dual-direction switchable | Indicators: OUT (orange/green selectable for 2-output models), L/D (orange), ST (green), DPC (green) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Max sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Active — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: OFF / OFF-delay / ON-delay / One-shot / ON-OFF delay (1ms ~ 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF / via External Input | Eco Mode: OFF / ECO ON (display dim) / ECO LO (display off) | Output 1 Mode: Standard detection / Area detection / Differential detection | Maximum Connectable Units: 30 units | Mutual Interference Prevention: HS/Stnd/GIGA modes: 10 units (optical sync). SHS mode: disabled (E3NX-FA11-5 only: 2 units in SHS2) | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis (X/Y/Z) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
⭐ 2-channel communications-type smart fiber amplifier for connection to OMRON E3NW Sensor Communications Unit, enabling network-based dual-channel sensor data management over EtherCAT (E3NW-ECT) or CC-Link (E3NW-CCL). Each amplifier supports two fiber units (4 fiber unit holes) with two independent sensor outputs assigned to PLC I/O — halve your network node count compared to single-channel amplifiers. Eight Output 2 logic modes (AND/OR/XOR/GAP/sync/area) accessible via network for flexible inline inspection without PLC ladder logic changes. Same GIGA RAY light source, Smart Tuning, and APC + DPC auto-compensation as standard E3NX-MA. Power supplied through E3NW unit — no separate amplifier wiring. Up to 30 units (EtherCAT) or 16 units (CC-Link) per network segment. ⚠️ Requires E3NW Sensor Communications Unit (sold separately): E3NW-ECT or E3NW-CCL or E3NW-DS — contact for quote. ⚠️ E3NW-CRT (CompoNet) NOT compatible with E3NX-MA. Compatible with OMRON E32 series fiber heads.
⭐ 2-channel communications-type smart fiber amplifier for connection to OMRON E3NW Sensor Communications Unit, enabling network-based dual-channel sensor data management over EtherCAT (E3NW-ECT) or CC-Link (E3NW-CCL). Each amplifier supports two fiber units (4 fiber unit holes) with two independent sensor outputs assigned to PLC I/O — halve your network node count compared to single-channel amplifiers. Eight Output 2 logic modes (AND/OR/XOR/GAP/sync/area) accessible via network for flexible inline inspection without PLC ladder logic changes. Same GIGA RAY light source, Smart Tuning, and APC + DPC auto-compensation as standard E3NX-MA. Power supplied through E3NW unit — no separate amplifier wiring. Up to 30 units (EtherCAT) or 16 units (CC-Link) per network segment. ⚠️ Requires E3NW Sensor Communications Unit (sold separately): E3NW-ECT or E3NW-CCL or E3NW-DS — contact for quote. ⚠️ E3NW-CRT (CompoNet) NOT compatible with E3NX-MA. Compatible with OMRON E32 series fiber heads.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-MA0 | OMRON E3NX-MA0 communications 2-channel smart fiber amplifier, for E3NW-ECT/CCL/DS Sensor Communications Unit. | OMRON | Output: Communications-only (no direct output, network-assigned) | I/O Configuration: Communications connector type, 2 channels assigned via network | Connection: Communications connector — requires E3NW-ECT (EtherCAT) or E3NW-CCL (CC-Link) or E3NW-DS Sensor Communications Unit sold separately. NOT compatible with E3NW-CRT. | Power Supply: Supplied via E3NW Sensor Communications Unit | Output Configuration: 2 sensor outputs (one per channel) assigned to PLC I/O table via network — read detected values and change settings via PLC operation | Required Communications Unit (sold separately): E3NW-ECT (EtherCAT, 30 units max.) / E3NW-CCL (CC-Link, 16 units max.) / E3NW-DS (Distributed Sensor Unit, compatible with both) | Compatibility Note: ⚠️ E3NW-CRT (CompoNet) NOT compatible with E3NX-MA — use E3NW-ECT or E3NW-CCL only. | Response Time — SHS (Super-high-speed): 100 μs | Response Time — HS (High-speed): 450 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Application Notes: Network-based 2-channel sensor management: per-channel data logging, remote parameter setting, real-time diagnostics, factory-wide sensor monitoring via EtherCAT or CC-Link | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1/OUT2 (orange), OUT1/OUT2 selection (orange), L/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Maximum sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled / OFF-delay / ON-delay / One-shot / ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF selectable | Eco Mode: OFF (display lit) / ECO ON (display off) / ECO LO (display dimmed) | Output 1 Mode: Standard detection / Area detection | Output 2 Mode (8 options): Standard detection / AND output / OR output / XOR output / GAP output / Falling synchronization / Rising synchronization / Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) / User reset (saved settings) | Mutual Interference Prevention: 9 units (HS/Stnd/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C/E2C/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11/MC11-SV2/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S / E3X-CRT / E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these) |
⭐ 2-channel smart fiber amplifier — single unit with the dimensions of a standard 1-unit amplifier delivers two-channel functionality, reducing installation space by half and enabling smaller equipment and control panels. Connect two fiber units to one amplifier (4 fiber unit holes vs 2 in standard E3NX-FA). Two independent control outputs with eight selectable Output 2 modes including AND, OR, XOR, GAP detection, Rising/Falling synchronization, and Area detection — leverage dual channels for advanced multi-point inspection, edge detection, and logic combinations without external PLC programming. GIGA RAY light source for stable detection from transparent objects to low-reflective workpieces. Smart Tuning auto-configures both channels' optimum settings. APC + DPC auto-compensation for maintenance-free operation. Four response modes (SHS 100μs ~ GIGA 16ms). White 7-segment + green sub-display. BANK 1~4 selectable. 10-30 VDC, NPN or PNP. Up to 30 units gang-mounted with 9-unit mutual interference prevention. Compatible with OMRON E32 series fiber heads. Wire-saving Connectors (E3X-CN21 Master 4-conductor / E3X-CN22 Slave 2-conductor — same as E3NX-FA High-Function Type), Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
⭐ 2-channel smart fiber amplifier — single unit with the dimensions of a standard 1-unit amplifier delivers two-channel functionality, reducing installation space by half and enabling smaller equipment and control panels. Connect two fiber units to one amplifier (4 fiber unit holes vs 2 in standard E3NX-FA). Two independent control outputs with eight selectable Output 2 modes including AND, OR, XOR, GAP detection, Rising/Falling synchronization, and Area detection — leverage dual channels for advanced multi-point inspection, edge detection, and logic combinations without external PLC programming. GIGA RAY light source for stable detection from transparent objects to low-reflective workpieces. Smart Tuning auto-configures both channels' optimum settings. APC + DPC auto-compensation for maintenance-free operation. Four response modes (SHS 100μs ~ GIGA 16ms). White 7-segment + green sub-display. BANK 1~4 selectable. 10-30 VDC, NPN or PNP. Up to 30 units gang-mounted with 9-unit mutual interference prevention. Compatible with OMRON E32 series fiber heads. Wire-saving Connectors (E3X-CN21 Master 4-conductor / E3X-CN22 Slave 2-conductor — same as E3NX-FA High-Function Type), Mounting Bracket (E39-L143), DIN Track, End Plate (PFP-M) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3NX-MA11 | OMRON E3NX-MA11 standard 2-channel smart fiber amplifier, NPN, 2-output, 2m pre-wired. | OMRON | Output: NPN | I/O Configuration: 2 outputs (one per channel) | Connection: Pre-wired (2m cable, 4 dia., 4 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate/reset | Response Time — HS (High-speed): 450 μs operate/reset | Response Time — Stnd (Standard): 1 ms operate/reset | Response Time — GIGA (Giga-power): 16 ms operate/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1/OUT2 (orange), OUT1/OUT2 selection (orange), L/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Maximum sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled / OFF-delay / ON-delay / One-shot / ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF selectable | Eco Mode: OFF (display lit) / ECO ON (display off) / ECO LO (display dimmed) | Output 1 Mode: Standard detection / Area detection | Output 2 Mode (8 options): Standard detection / AND output / OR output / XOR output / GAP output / Falling synchronization / Rising synchronization / Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) / User reset (saved settings) | Mutual Interference Prevention: 9 units (HS/Stnd/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C/E2C/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11/MC11-SV2/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S / E3X-CRT / E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these) | |
| E3NX-MA41 | OMRON E3NX-MA41 standard 2-channel smart fiber amplifier, PNP, 2-output, 2m pre-wired. | OMRON | Output: PNP | I/O Configuration: 2 outputs (one per channel) | Connection: Pre-wired (2m cable, 4 dia., 4 conductors) | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate/reset | Response Time — HS (High-speed): 450 μs operate/reset | Response Time — Stnd (Standard): 1 ms operate/reset | Response Time — GIGA (Giga-power): 16 ms operate/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1/OUT2 (orange), OUT1/OUT2 selection (orange), L/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Maximum sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled / OFF-delay / ON-delay / One-shot / ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF selectable | Eco Mode: OFF (display lit) / ECO ON (display off) / ECO LO (display dimmed) | Output 1 Mode: Standard detection / Area detection | Output 2 Mode (8 options): Standard detection / AND output / OR output / XOR output / GAP output / Falling synchronization / Rising synchronization / Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) / User reset (saved settings) | Mutual Interference Prevention: 9 units (HS/Stnd/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C/E2C/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11/MC11-SV2/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S / E3X-CRT / E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these) | |
| E3NX-MA6 | OMRON E3NX-MA6 standard 2-channel smart fiber amplifier, NPN, 2-output, wire-saving connector. | OMRON | Output: NPN | I/O Configuration: 2 outputs (one per channel) | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate/reset | Response Time — HS (High-speed): 450 μs operate/reset | Response Time — Stnd (Standard): 1 ms operate/reset | Response Time — GIGA (Giga-power): 16 ms operate/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1/OUT2 (orange), OUT1/OUT2 selection (orange), L/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Maximum sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled / OFF-delay / ON-delay / One-shot / ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF selectable | Eco Mode: OFF (display lit) / ECO ON (display off) / ECO LO (display dimmed) | Output 1 Mode: Standard detection / Area detection | Output 2 Mode (8 options): Standard detection / AND output / OR output / XOR output / GAP output / Falling synchronization / Rising synchronization / Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) / User reset (saved settings) | Mutual Interference Prevention: 9 units (HS/Stnd/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C/E2C/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11/MC11-SV2/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S / E3X-CRT / E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these) | |
| E3NX-MA8 | OMRON E3NX-MA8 standard 2-channel smart fiber amplifier, PNP, 2-output, wire-saving connector. | OMRON | Output: PNP | I/O Configuration: 2 outputs (one per channel) | Connection: Wire-saving connector — E3X-CN21 Master (4-conductor) / E3X-CN22 Slave (2-conductor) sold separately | Power Consumption: Normal: 960mW max. (40mA @ 24VDC) | ECO ON: 770mW (32mA) | ECO LO: 870mW (36mA) | Control Output: NPN or PNP open-collector, 30 VDC max., 2 outputs (one per channel) | Load Current: 100 mA max. (1-3 amps), 20 mA max. (4-30 amps) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Response Time — SHS (Super-high-speed): 100 μs operate/reset | Response Time — HS (High-speed): 450 μs operate/reset | Response Time — Stnd (Standard): 1 ms operate/reset | Response Time — GIGA (Giga-power): 16 ms operate/reset | Channel Usage Note: ⚠️ If using only 1 channel, do NOT leave the unused channel's output cable unwired — incident level changes on unused channel may produce incorrect output. Use both channels or wire both outputs. | Light Source: Red 4-element LED (625 nm) | Channels: ⭐ 2-channel — single amplifier supports two fiber units simultaneously (4 fiber unit holes) | Display: 7-segment digital display — sub digital (green) + main digital (white), reversible | Indicators: OUT1/OUT2 (orange), OUT1/OUT2 selection (orange), L/D (orange), ST (blue, smart tuning), DPC (green, dynamic power control) | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Sensitivity Setting: Smart Tuning [2-point tuning / Full auto tuning / Position tuning / Maximum sensitivity tuning / Power tuning / Percent tuning -99% to +99%] or Manual adjustment | Auto Power Control (APC): Always ON | Dynamic Power Control (DPC): Provided — auto-compensates incident level for dirt, vibration, and LED aged deterioration | Timer Function: Selectable: Disabled / OFF-delay / ON-delay / One-shot / ON-delay+OFF-delay (1ms to 9999ms range) | Bank Switching: BANK 1~4 selectable | Power Tuning: ON / OFF selectable | Eco Mode: OFF (display lit) / ECO ON (display off) / ECO LO (display dimmed) | Output 1 Mode: Standard detection / Area detection | Output 2 Mode (8 options): Standard detection / AND output / OR output / XOR output / GAP output / Falling synchronization / Rising synchronization / Area detection — leverage 2-channel for advanced logic | Hysteresis Width: Standard or User-set (0~9999 range) | Zero Reset: Supported (negative values displayable, threshold shifted) | Setting Reset: Initial reset (factory defaults) / User reset (saved settings) | Mutual Interference Prevention: 9 units (HS/Stnd/GIGA modes, optical sync). SHS mode: disabled. NOT compatible with E3C/E2C/E3X series. | Maximum Connectable Units: 30 units | Ambient Temperature (Operating): -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16), -25°C to 40°C (17-30) | Ambient Humidity: 35% to 85% RH (no condensation) | Altitude: 2,000 m max. | Pollution Degree: 3 (per IEC 60947-1) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Degree of Protection: IEC 60529 IP50 (with Protective Cover attached) | Material: Case/Cover: Polycarbonate (PC), Cable: PVC | Compatible Fiber Heads: OMRON E32 series fiber optic head units | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | Mobile Console Compatibility: E3X-MC11/MC11-SV2/MC11-S NOT supported | Communications Unit Compatibility: E3X-DRT21-S / E3X-CRT / E3X-ECT NOT compatible (Standard Type and High-function Type cannot use these) |
Color mark photoelectric sensor with RGB 3-color LED (Red 635nm + Green 525nm + Blue 465nm) for stable detection on glossy aluminum-vapor-deposited packaging, colorful printed packaging with subtle color differences, and packaging with lot-to-lot color variation. Standalone diffuse-reflective M12 sensor (no fiber required) — compact 80×54×56mm zinc die-cast IP67 housing. Thin projection beam + large lens optics keeps detection stable even when workpiece tilts. 9x S/N ratio improvement vs E3ZM-V via 3-LED light source plus high-efficiency optical design. Hi dynamic range covers black to mirror-like surfaces without saturation. Easy 2-button teaching (MARK + BKGD) for quick setup. Fast 50μs response (2-point teaching). 11 color discrimination + black. ⭐ IO-Link models (E3S-DCP21-IL2/IL3) transmit 0~4095 RGB values to PLC for color variation database management — root-cause analysis on color drift issues, optimal threshold tuning, and design-stage validation. Push-pull (IO-Link models) or NPN output. 10-30 VDC. M12 4-pin connector. Sensor I/O cables (XS2F or XS5W series, M12 4-pin, 2m or 5m, straight or L-shaped) sold separately — see separate listing.
Color mark photoelectric sensor with RGB 3-color LED (Red 635nm + Green 525nm + Blue 465nm) for stable detection on glossy aluminum-vapor-deposited packaging, colorful printed packaging with subtle color differences, and packaging with lot-to-lot color variation. Standalone diffuse-reflective M12 sensor (no fiber required) — compact 80×54×56mm zinc die-cast IP67 housing. Thin projection beam + large lens optics keeps detection stable even when workpiece tilts. 9x S/N ratio improvement vs E3ZM-V via 3-LED light source plus high-efficiency optical design. Hi dynamic range covers black to mirror-like surfaces without saturation. Easy 2-button teaching (MARK + BKGD) for quick setup. Fast 50μs response (2-point teaching). 11 color discrimination + black. ⭐ IO-Link models (E3S-DCP21-IL2/IL3) transmit 0~4095 RGB values to PLC for color variation database management — root-cause analysis on color drift issues, optimal threshold tuning, and design-stage validation. Push-pull (IO-Link models) or NPN output. 10-30 VDC. M12 4-pin connector. Sensor I/O cables (XS2F or XS5W series, M12 4-pin, 2m or 5m, straight or L-shaped) sold separately — see separate listing.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3S-DCP21-IL2 | OMRON E3S-DCP21-IL2 color mark photoelectric sensor, push-pull output, IO-Link COM2, M12 4-pin connector. | OMRON | Output: Push-pull | Communication: IO-Link COM2 (38.4 kbps) | Detection Method: Diffuse reflective (color mark detection) | Sensing Distance: 10 ±3 mm (white drawing paper 10×10mm, 1×4mm projection spot) | Light Source: Red LED (635 nm) + Green LED (525 nm) + Blue LED (465 nm) — 3-color LED light source with high-efficiency optics | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Power Consumption: 960 mW max. (40 mA @ 24 VDC) | Control Output: Push-pull (IL2/IL3) or NPN open-collector, 100 mA max., 30 VDC max. | Indicators: Operation (orange), RUN (green, blinking during IO-Link), 7-segment (white, BANK number), Key Lock (white), Timer (white), 1-point teaching mode (white) | Response Time: 50 μs operate/reset (2-point teaching mode) / 150 μs operate/reset (1-point teaching mode) | Sensitivity Setting: Teaching method (1-point or 2-point with MARK/BKGD buttons) | Operation Mode: Push-pull: NO (mark=High) / NC. NPN: NO (mark=ON) / NC. | Connection: M12 4-pin connector (90° rotatable) | Protection: IP67 (per IEC 60529) | Ambient Temperature: -10°C to 55°C operating, -25°C to 70°C storage | Ambient Humidity: 35% to 85% RH operating, 35% to 95% storage (no condensation) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Material: Case: Zinc die-cast (nickel-plated) | Lens: PMMA | Display: ABS | Buttons: Elastomer | Connector: Zinc die-cast (nickel-plated) | Weight: Approx. 370g (packed) / 320g (unit only) | 11 Color Standard Discrimination: White (Munsell N9.5), Red (4R 4.5/12.0), Yellow-Red, Yellow, Yellow-Green, Green, Blue-Green, Blue, Blue-Violet, Violet, Magenta + Black (N2.0) | Compatible Cables (sold separately): XS2F single-ended (M12 straight or L-shaped, 2m/5m) / XS5W double-ended smart click (M12 straight or L-shaped, 2m/5m) — see separate listing | |
| E3S-DCP21-IL3 | OMRON E3S-DCP21-IL3 color mark photoelectric sensor, push-pull output, IO-Link COM3 high-speed, M12 4-pin connector. | OMRON | Output: Push-pull | Communication: IO-Link COM3 (230.4 kbps) — high-speed | Detection Method: Diffuse reflective (color mark detection) | Sensing Distance: 10 ±3 mm (white drawing paper 10×10mm, 1×4mm projection spot) | Light Source: Red LED (635 nm) + Green LED (525 nm) + Blue LED (465 nm) — 3-color LED light source with high-efficiency optics | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Power Consumption: 960 mW max. (40 mA @ 24 VDC) | Control Output: Push-pull (IL2/IL3) or NPN open-collector, 100 mA max., 30 VDC max. | Indicators: Operation (orange), RUN (green, blinking during IO-Link), 7-segment (white, BANK number), Key Lock (white), Timer (white), 1-point teaching mode (white) | Response Time: 50 μs operate/reset (2-point teaching mode) / 150 μs operate/reset (1-point teaching mode) | Sensitivity Setting: Teaching method (1-point or 2-point with MARK/BKGD buttons) | Operation Mode: Push-pull: NO (mark=High) / NC. NPN: NO (mark=ON) / NC. | Connection: M12 4-pin connector (90° rotatable) | Protection: IP67 (per IEC 60529) | Ambient Temperature: -10°C to 55°C operating, -25°C to 70°C storage | Ambient Humidity: 35% to 85% RH operating, 35% to 95% storage (no condensation) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Material: Case: Zinc die-cast (nickel-plated) | Lens: PMMA | Display: ABS | Buttons: Elastomer | Connector: Zinc die-cast (nickel-plated) | Weight: Approx. 370g (packed) / 320g (unit only) | 11 Color Standard Discrimination: White (Munsell N9.5), Red (4R 4.5/12.0), Yellow-Red, Yellow, Yellow-Green, Green, Blue-Green, Blue, Blue-Violet, Violet, Magenta + Black (N2.0) | Compatible Cables (sold separately): XS2F single-ended (M12 straight or L-shaped, 2m/5m) / XS5W double-ended smart click (M12 straight or L-shaped, 2m/5m) — see separate listing | |
| E3S-DCN21 | OMRON E3S-DCN21 color mark photoelectric sensor, NPN open-collector, standard I/O, M12 4-pin connector. | OMRON | Output: NPN open-collector | Communication: Standard I/O only (no IO-Link) | Detection Method: Diffuse reflective (color mark detection) | Sensing Distance: 10 ±3 mm (white drawing paper 10×10mm, 1×4mm projection spot) | Light Source: Red LED (635 nm) + Green LED (525 nm) + Blue LED (465 nm) — 3-color LED light source with high-efficiency optics | Power Supply: 10 to 30 VDC, ripple (p-p) 10% max. | Power Consumption: 960 mW max. (40 mA @ 24 VDC) | Control Output: Push-pull (IL2/IL3) or NPN open-collector, 100 mA max., 30 VDC max. | Indicators: Operation (orange), RUN (green, blinking during IO-Link), 7-segment (white, BANK number), Key Lock (white), Timer (white), 1-point teaching mode (white) | Response Time: 50 μs operate/reset (2-point teaching mode) / 150 μs operate/reset (1-point teaching mode) | Sensitivity Setting: Teaching method (1-point or 2-point with MARK/BKGD buttons) | Operation Mode: Push-pull: NO (mark=High) / NC. NPN: NO (mark=ON) / NC. | Connection: M12 4-pin connector (90° rotatable) | Protection: IP67 (per IEC 60529) | Ambient Temperature: -10°C to 55°C operating, -25°C to 70°C storage | Ambient Humidity: 35% to 85% RH operating, 35% to 95% storage (no condensation) | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Material: Case: Zinc die-cast (nickel-plated) | Lens: PMMA | Display: ABS | Buttons: Elastomer | Connector: Zinc die-cast (nickel-plated) | Weight: Approx. 370g (packed) / 320g (unit only) | 11 Color Standard Discrimination: White (Munsell N9.5), Red (4R 4.5/12.0), Yellow-Red, Yellow, Yellow-Green, Green, Blue-Green, Blue, Blue-Violet, Violet, Magenta + Black (N2.0) | Compatible Cables (sold separately): XS2F single-ended (M12 straight or L-shaped, 2m/5m) / XS5W double-ended smart click (M12 straight or L-shaped, 2m/5m) — see separate listing |
Smart fiber amplifier unit with one-touch Smart Tuning that auto-configures optimum settings with a single button press. GIGA RAY II light source delivers best-in-class power for stable detection of low-reflective and large workpieces. APC (Auto Power Control) plus DPC (Dynamic Power Control) provide maintenance-free operation by automatically compensating for dirt, vibration, and LED aged deterioration — long-term stable detection without recalibration. Twin digital display (green threshold + red incident level) and visible indicators (L/D, OUT, ST, DPC) for at-a-glance status. Pushbutton operation works even with gloves on. Four selectable response modes: Super-high-speed (50μs), High-speed (250μs default), Standard (1ms), and Giga-power (16ms) — one amplifier covers fast-line counting through long-distance detection. 12-24 VDC, NPN or PNP open-collector output. Up to 16 units side-by-side mounted with mutual interference prevention. Compatible with OMRON E32 series fiber optic head units. M8 connector models compatible with XS3F-M421/M422 sensor I/O cables (separately listed). Wire-saving Connectors (E3X-CN11/CN12), Mounting Bracket (E39-L143), DIN Track (PFP-100N/50N/100N2), and End Plate (PFP-M) sold separately — contact for quote.
Smart fiber amplifier unit with one-touch Smart Tuning that auto-configures optimum settings with a single button press. GIGA RAY II light source delivers best-in-class power for stable detection of low-reflective and large workpieces. APC (Auto Power Control) plus DPC (Dynamic Power Control) provide maintenance-free operation by automatically compensating for dirt, vibration, and LED aged deterioration — long-term stable detection without recalibration. Twin digital display (green threshold + red incident level) and visible indicators (L/D, OUT, ST, DPC) for at-a-glance status. Pushbutton operation works even with gloves on. Four selectable response modes: Super-high-speed (50μs), High-speed (250μs default), Standard (1ms), and Giga-power (16ms) — one amplifier covers fast-line counting through long-distance detection. 12-24 VDC, NPN or PNP open-collector output. Up to 16 units side-by-side mounted with mutual interference prevention. Compatible with OMRON E32 series fiber optic head units. M8 connector models compatible with XS3F-M421/M422 sensor I/O cables (separately listed). Wire-saving Connectors (E3X-CN11/CN12), Mounting Bracket (E39-L143), DIN Track (PFP-100N/50N/100N2), and End Plate (PFP-M) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3X-HD11 2M | OMRON E3X-HD11 smart fiber amplifier, NPN open-collector, 2m pre-wired cable. | OMRON | Output: NPN | Connection: Pre-wired (2m vinyl-insulated round cable, 4 dia., 3 conductors) | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-HD41 2M | OMRON E3X-HD41 smart fiber amplifier, PNP open-collector, 2m pre-wired cable. | OMRON | Output: PNP | Connection: Pre-wired (2m vinyl-insulated round cable, 4 dia., 3 conductors) | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-HD6 | OMRON E3X-HD6 smart fiber amplifier, NPN, wire-saving connector type. | OMRON | Output: NPN | Connection: Wire-saving connector (E3X-CN11 Master 3-conductor / E3X-CN12 Slave 1-conductor sold separately) | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-HD8 | OMRON E3X-HD8 smart fiber amplifier, PNP, wire-saving connector type. | OMRON | Output: PNP | Connection: Wire-saving connector (E3X-CN11 Master 3-conductor / E3X-CN12 Slave 1-conductor sold separately) | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-HD14 | OMRON E3X-HD14 smart fiber amplifier, NPN, M8 4-pin connector. | OMRON | Output: NPN | Connection: M8 4-pin connector — Compatible XS3F cables: XS3F-M421-402-A / XS3F-M421-405-A (straight, 2m/5m), XS3F-M422-402-A / XS3F-M422-405-A (L-shaped, 2m/5m) — separately listed under OMRON Sensor I/O Connector Cables | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-HD44 | OMRON E3X-HD44 smart fiber amplifier, PNP, M8 4-pin connector. | OMRON | Output: PNP | Connection: M8 4-pin connector — Compatible XS3F cables: XS3F-M421-402-A / XS3F-M421-405-A (straight, 2m/5m), XS3F-M422-402-A / XS3F-M422-405-A (L-shaped, 2m/5m) — separately listed under OMRON Sensor I/O Connector Cables | Light Source: Red 4-element LED (625 nm) — GIGA RAY II | Display: Twin digital display: green (threshold) + red (incident level), 4 visible indicators (L/D, OUT, ST, DPC) | Sensitivity Setting: Smart Tuning (single-button auto-setup) + UP/DOWN fine-tune + MODE/L-D pushbuttons | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 720 mW max. Normal / 530 mW Eco-ON / 640 mW Eco-LO (30 mA @ 24 VDC) | Control Output: Open-collector (NPN or PNP), 26.4 VDC max. | Load Current: 100 mA max. (1-3 amplifiers gang-mounted), 20 mA max. (4-16 amplifiers) | Residual Voltage: 1 V max. (<10 mA load) / 2 V max. (10-100 mA load) | OFF Current: 0.1 mA max. | Mode Selector: Light-ON / Dark-ON | Response Time — SHS (Super-high-speed): 50 μs (NPN) / 55 μs (PNP) | Response Time — HS (High-speed, default): 250 μs | Response Time — Stnd (Standard): 1 ms | Response Time — GIGA (Giga-power): 16 ms | Auto Power Control (APC): Always ON (light intensity auto-compensation) | Dynamic Power Control (DPC): Active threshold-based incident-level auto-compensation — compensates for dirt, vibration, and LED aged deterioration | Other Functions: Power tuning, differential detection, timer (OFF-delay/ON-delay/one-shot), zero reset, settings reset, Eco mode | Maximum Connectable Units: 16 units (standard) — up to 30 units with E3X-ECT Communications Unit | Mutual Interference Prevention: Up to 10 units (optical sync, disabled in SHS mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-2 amps), -25°C to 50°C (3-10), -25°C to 45°C (11-16) | Vibration Resistance: 10-55 Hz, 1.5mm double amplitude, 2 hours each axis (X/Y/Z) | Shock Resistance: 500 m/s² × 3 times each axis | Insulation Resistance: 20 MΩ min. (at 500 VDC) | Dielectric Strength: 1,000 VAC at 50/60 Hz for 1 minute | Compatible Fiber Heads: OMRON E32 series fiber optic head units (E32-L11FP/L11FS/L12FS and others) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |
OMRON E3X-MZV Smart Fiber Amplifier — Value Line (2-channel, NEW). 1 amp body provides 2 independent detection points — 1/2 installation space and up to 60% wiring savings compared to standard single-channel amplifiers (with wire-saving connector). Red 4-element LED (625 nm), min. detectable object 3 μm. Response time 100 μs (Super High Speed) / 250 μs (High Speed) / 1 ms (Standard) / 16 ms (Giga Power). Smart Tuning (2-press auto-adjust), DPC, ATC, built-in timer (1-9999 ms). Mutual interference prevention by emission cycle switching (max 2 MZV units, or 2× E3X-ZV + 1× E3X-MZV combination). Independent CH1/CH2 indicators and selection. User Save/Reset for easy field recovery. Available with NPN or PNP output, pre-wired cable (2 m) or wire-saving connector type. 12-24 VDC, IEC compliant, CE marked. Patented dual-channel design.
OMRON E3X-MZV Smart Fiber Amplifier — Value Line (2-channel, NEW). 1 amp body provides 2 independent detection points — 1/2 installation space and up to 60% wiring savings compared to standard single-channel amplifiers (with wire-saving connector). Red 4-element LED (625 nm), min. detectable object 3 μm. Response time 100 μs (Super High Speed) / 250 μs (High Speed) / 1 ms (Standard) / 16 ms (Giga Power). Smart Tuning (2-press auto-adjust), DPC, ATC, built-in timer (1-9999 ms). Mutual interference prevention by emission cycle switching (max 2 MZV units, or 2× E3X-ZV + 1× E3X-MZV combination). Independent CH1/CH2 indicators and selection. User Save/Reset for easy field recovery. Available with NPN or PNP output, pre-wired cable (2 m) or wire-saving connector type. 12-24 VDC, IEC compliant, CE marked. Patented dual-channel design.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3X-MZV11 2M | E3X-MZV Value Line 2-channel fiber amplifier, NPN, Pre-wired Cable 2 m | OMRON | Channels: 2-Channel (independent) | Outputs: 2 outputs | Response Time — Super High Speed (SHS): 100 μs (operate/reset) | Response Time — High Speed (HS): 250 μs (operate/reset, 700 μs with mutual interference) | Response Time — Standard (Stnd): 1 ms (operate/reset, 1.6 ms with mutual interference) | Response Time — Giga Power (GIGA): 16 ms (operate/reset) | Mutual Interference Prevention: Emission cycle switching (max 2 units MZV, or 2× E3X-ZV + 1× E3X-MZV, no close-mounting required) | Power Consumption (Normal): 820 mW max (24V: 35 mA / 12V: 69 mA) | Power Consumption (Eco ON): 600 mW max (24V: 25 mA / 12V: 50 mA) | Note: 1 amp body = 2 detection points / 1/2 installation space / up to 60% wiring savings with wire-saving connector | Output Type: NPN open collector (load 100 mA max, residual voltage 1-2 V) | Connection: Pre-wired Cable 2 m | Light Source: Red 4-element LED (625 nm) | Power Supply: 12-24 VDC ±10% (ripple p-p 10% max) | Min. Detectable Object: 3 μm (with E32-CC200) | Sensitivity Adjustment: Smart Tuning (2-point / power tuning / percent / max sensitivity / full auto / positioning) or manual | Display: 7-segment (green min. + red incident light) — orientation reversible | Functions: Smart Tuning / DPC (auto light correction) / ATC (auto threshold correction) / Timer / Zero Reset / User Save+Reset / Eco / Power Tuning | Timer: Off / Off-delay / On-delay / One-shot (1-9999 ms) | Ambient Illuminance: Incandescent 20,000 lx max / Sunlight 30,000 lx max | Ambient Temperature: Operating -25 to +55 °C / Storage -30 to +70 °C (no icing/condensation) | Ambient Humidity: 35-85 %RH (operating and storage) | Insulation Resistance: 20 MΩ min. (500 VDC megger) | Dielectric Strength: 1,000 VAC 50/60 Hz 1 min | Vibration Resistance: 10-55 Hz, 1.5 mm double amplitude, 2 h each X/Y/Z | Shock Resistance: 500 m/s² 3 times each X/Y/Z | Protection Circuits: Reverse polarity / Output short-circuit / Output reverse polarity | Housing Material: Polycarbonate (case + cover) | Compliance: CE | Compatible Connector: — | Weight (Packed): approx. 100 g | Weight (Body Only): approx. 75 g | |
| E3X-MZV41 2M | E3X-MZV Value Line 2-channel fiber amplifier, PNP, Pre-wired Cable 2 m | OMRON | Channels: 2-Channel (independent) | Outputs: 2 outputs | Response Time — Super High Speed (SHS): 100 μs (operate/reset) | Response Time — High Speed (HS): 250 μs (operate/reset, 700 μs with mutual interference) | Response Time — Standard (Stnd): 1 ms (operate/reset, 1.6 ms with mutual interference) | Response Time — Giga Power (GIGA): 16 ms (operate/reset) | Mutual Interference Prevention: Emission cycle switching (max 2 units MZV, or 2× E3X-ZV + 1× E3X-MZV, no close-mounting required) | Power Consumption (Normal): 820 mW max (24V: 35 mA / 12V: 69 mA) | Power Consumption (Eco ON): 600 mW max (24V: 25 mA / 12V: 50 mA) | Note: 1 amp body = 2 detection points / 1/2 installation space / up to 60% wiring savings with wire-saving connector | Output Type: PNP open collector (load 100 mA max, residual voltage 1-2 V) | Connection: Pre-wired Cable 2 m | Light Source: Red 4-element LED (625 nm) | Power Supply: 12-24 VDC ±10% (ripple p-p 10% max) | Min. Detectable Object: 3 μm (with E32-CC200) | Sensitivity Adjustment: Smart Tuning (2-point / power tuning / percent / max sensitivity / full auto / positioning) or manual | Display: 7-segment (green min. + red incident light) — orientation reversible | Functions: Smart Tuning / DPC (auto light correction) / ATC (auto threshold correction) / Timer / Zero Reset / User Save+Reset / Eco / Power Tuning | Timer: Off / Off-delay / On-delay / One-shot (1-9999 ms) | Ambient Illuminance: Incandescent 20,000 lx max / Sunlight 30,000 lx max | Ambient Temperature: Operating -25 to +55 °C / Storage -30 to +70 °C (no icing/condensation) | Ambient Humidity: 35-85 %RH (operating and storage) | Insulation Resistance: 20 MΩ min. (500 VDC megger) | Dielectric Strength: 1,000 VAC 50/60 Hz 1 min | Vibration Resistance: 10-55 Hz, 1.5 mm double amplitude, 2 h each X/Y/Z | Shock Resistance: 500 m/s² 3 times each X/Y/Z | Protection Circuits: Reverse polarity / Output short-circuit / Output reverse polarity | Housing Material: Polycarbonate (case + cover) | Compliance: CE | Compatible Connector: — | Weight (Packed): approx. 100 g | Weight (Body Only): approx. 75 g | |
| E3X-MZV6 | E3X-MZV Value Line 2-channel fiber amplifier, NPN, Wire-saving Connector | OMRON | Channels: 2-Channel (independent) | Outputs: 2 outputs | Response Time — Super High Speed (SHS): 100 μs (operate/reset) | Response Time — High Speed (HS): 250 μs (operate/reset, 700 μs with mutual interference) | Response Time — Standard (Stnd): 1 ms (operate/reset, 1.6 ms with mutual interference) | Response Time — Giga Power (GIGA): 16 ms (operate/reset) | Mutual Interference Prevention: Emission cycle switching (max 2 units MZV, or 2× E3X-ZV + 1× E3X-MZV, no close-mounting required) | Power Consumption (Normal): 820 mW max (24V: 35 mA / 12V: 69 mA) | Power Consumption (Eco ON): 600 mW max (24V: 25 mA / 12V: 50 mA) | Note: 1 amp body = 2 detection points / 1/2 installation space / up to 60% wiring savings with wire-saving connector | Output Type: NPN open collector (load 100 mA max, residual voltage 1-2 V) | Connection: Wire-saving Connector | Light Source: Red 4-element LED (625 nm) | Power Supply: 12-24 VDC ±10% (ripple p-p 10% max) | Min. Detectable Object: 3 μm (with E32-CC200) | Sensitivity Adjustment: Smart Tuning (2-point / power tuning / percent / max sensitivity / full auto / positioning) or manual | Display: 7-segment (green min. + red incident light) — orientation reversible | Functions: Smart Tuning / DPC (auto light correction) / ATC (auto threshold correction) / Timer / Zero Reset / User Save+Reset / Eco / Power Tuning | Timer: Off / Off-delay / On-delay / One-shot (1-9999 ms) | Ambient Illuminance: Incandescent 20,000 lx max / Sunlight 30,000 lx max | Ambient Temperature: Operating -25 to +55 °C / Storage -30 to +70 °C (no icing/condensation) | Ambient Humidity: 35-85 %RH (operating and storage) | Insulation Resistance: 20 MΩ min. (500 VDC megger) | Dielectric Strength: 1,000 VAC 50/60 Hz 1 min | Vibration Resistance: 10-55 Hz, 1.5 mm double amplitude, 2 h each X/Y/Z | Shock Resistance: 500 m/s² 3 times each X/Y/Z | Protection Circuits: Reverse polarity / Output short-circuit / Output reverse polarity | Housing Material: Polycarbonate (case + cover) | Compliance: CE | Compatible Connector: E3X-CN21 (master, 4-wire) / E3X-CN22 (slave, 2-wire) — sold separately | Weight (Packed): approx. 45 g | Weight (Body Only): approx. 20 g | |
| E3X-MZV8 | E3X-MZV Value Line 2-channel fiber amplifier, PNP, Wire-saving Connector | OMRON | Channels: 2-Channel (independent) | Outputs: 2 outputs | Response Time — Super High Speed (SHS): 100 μs (operate/reset) | Response Time — High Speed (HS): 250 μs (operate/reset, 700 μs with mutual interference) | Response Time — Standard (Stnd): 1 ms (operate/reset, 1.6 ms with mutual interference) | Response Time — Giga Power (GIGA): 16 ms (operate/reset) | Mutual Interference Prevention: Emission cycle switching (max 2 units MZV, or 2× E3X-ZV + 1× E3X-MZV, no close-mounting required) | Power Consumption (Normal): 820 mW max (24V: 35 mA / 12V: 69 mA) | Power Consumption (Eco ON): 600 mW max (24V: 25 mA / 12V: 50 mA) | Note: 1 amp body = 2 detection points / 1/2 installation space / up to 60% wiring savings with wire-saving connector | Output Type: PNP open collector (load 100 mA max, residual voltage 1-2 V) | Connection: Wire-saving Connector | Light Source: Red 4-element LED (625 nm) | Power Supply: 12-24 VDC ±10% (ripple p-p 10% max) | Min. Detectable Object: 3 μm (with E32-CC200) | Sensitivity Adjustment: Smart Tuning (2-point / power tuning / percent / max sensitivity / full auto / positioning) or manual | Display: 7-segment (green min. + red incident light) — orientation reversible | Functions: Smart Tuning / DPC (auto light correction) / ATC (auto threshold correction) / Timer / Zero Reset / User Save+Reset / Eco / Power Tuning | Timer: Off / Off-delay / On-delay / One-shot (1-9999 ms) | Ambient Illuminance: Incandescent 20,000 lx max / Sunlight 30,000 lx max | Ambient Temperature: Operating -25 to +55 °C / Storage -30 to +70 °C (no icing/condensation) | Ambient Humidity: 35-85 %RH (operating and storage) | Insulation Resistance: 20 MΩ min. (500 VDC megger) | Dielectric Strength: 1,000 VAC 50/60 Hz 1 min | Vibration Resistance: 10-55 Hz, 1.5 mm double amplitude, 2 h each X/Y/Z | Shock Resistance: 500 m/s² 3 times each X/Y/Z | Protection Circuits: Reverse polarity / Output short-circuit / Output reverse polarity | Housing Material: Polycarbonate (case + cover) | Compliance: CE | Compatible Connector: E3X-CN21 (master, 4-wire) / E3X-CN22 (slave, 2-wire) — sold separately | Weight (Packed): approx. 45 g | Weight (Body Only): approx. 20 g |
High-speed fiber amplifier unit with 20μs operate / 30μs reset response time — 10x faster than standard models for high-speed production line detection. Bar display with 8-turn adjuster for easy sensitivity tuning. Bottle counting, small-part detection, and high-speed positioning applications. 12-24 VDC power supply, open-collector output (NPN/PNP), Light-ON/Dark-ON selectable. Note: Mutual interference prevention is disabled in high-speed mode. Compatible with E32 series fiber optic head units. Mounting Bracket (E39-L143) and DIN track End Plate (PFP-M) sold separately — contact for quote.
High-speed fiber amplifier unit with 20μs operate / 30μs reset response time — 10x faster than standard models for high-speed production line detection. Bar display with 8-turn adjuster for easy sensitivity tuning. Bottle counting, small-part detection, and high-speed positioning applications. 12-24 VDC power supply, open-collector output (NPN/PNP), Light-ON/Dark-ON selectable. Note: Mutual interference prevention is disabled in high-speed mode. Compatible with E32 series fiber optic head units. Mounting Bracket (E39-L143) and DIN track End Plate (PFP-M) sold separately — contact for quote.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| E3X-NA11F 2M | OMRON E3X-NA11F high-speed fiber amplifier, NPN, 20μs response, 2m cable. | OMRON | Output: NPN | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) | Display: 5-segment bar (4 green + 1 red) excess gain indicator | Sensitivity Setting: 8-turn sensitivity adjuster (with indicator) | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 840 mW max. (35 mA @ 24 VDC) | Control Output: Open-collector, 26.4 V max., 50 mA max., residual voltage 1 V max. | Mode Selector: Light-ON / Dark-ON | Response Time: Operate 20 μs max. / Reset 30 μs max. ⭐ High-speed | Timer Function: No timer / OFF-delay (40 ms fixed) — selectable | Mutual Interference Prevention: None (high-speed mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-3 amps), -25°C to 50°C (4-11), -25°C to 45°C (12-16) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) | |
| E3X-NA41F 2M | OMRON E3X-NA41F high-speed fiber amplifier, PNP, 20μs response, 2m cable. | OMRON | Output: PNP | Connection: Pre-wired (2m cable) | Light Source: Red 4-element LED (625 nm) | Display: 5-segment bar (4 green + 1 red) excess gain indicator | Sensitivity Setting: 8-turn sensitivity adjuster (with indicator) | Power Supply: 12 to 24 VDC ±10%, ripple (p-p) 10% max. | Power Consumption: 840 mW max. (35 mA @ 24 VDC) | Control Output: Open-collector, 26.4 V max., 50 mA max., residual voltage 1 V max. | Mode Selector: Light-ON / Dark-ON | Response Time: Operate 20 μs max. / Reset 30 μs max. ⭐ High-speed | Timer Function: No timer / OFF-delay (40 ms fixed) — selectable | Mutual Interference Prevention: None (high-speed mode) | Protection: IP50 (with Protective Cover) | Ambient Temperature: -25°C to 55°C (1-3 amps), -25°C to 50°C (4-11), -25°C to 45°C (12-16) | Mounting: DIN track or Mounting Bracket E39-L143 (sold separately) |