Electrical
'M' Series Electric Motors (Type M3). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: AR16/AR22/A10/A16/A22 (single), A1616/A1622/A2222 (double), A16R1/A22R1 (var/fixed double), PV2R1 (vane). Output: 5.5/7.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
'M' Series Electric Motors (Type M3). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: AR16/AR22/A10/A16/A22 (single), A1616/A1622/A2222 (double), A16R1/A22R1 (var/fixed double), PV2R1 (vane). Output: 5.5/7.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| M3-5.5-40 | M Series motor M3, 5.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M3 | Mounting: Coupling / separate housing (커플링) | Output: 5.5 kW x 4P | Electrical: 200V-50Hz: 23.4A rated / 200A start / 1465rpm; 200V-60Hz: 21.4A rated / 166A start / 1760rpm; 220V-60Hz: 20.6A rated / 183A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 63 kg | Applicable Pumps: AR16/AR22/A10/A16/A22 (single), A1616/A1622/A2222 (double), A16R1/A22R1 (var/fixed double), PV2R1 (vane) | Design No: 40 | |
| M3-7.5-40 | M Series motor M3, 7.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M3 | Mounting: Coupling / separate housing (커플링) | Output: 7.5 kW x 4P | Electrical: 200V-50Hz: 30.8A rated / 264A start / 1460rpm; 200V-60Hz: 28.6A rated / 218A start / 1755rpm; 220V-60Hz: 27.4A rated / 240A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 74 kg | Applicable Pumps: AR16/AR22/A10/A16/A22 (single), A1616/A1622/A2222 (double), A16R1/A22R1 (var/fixed double), PV2R1 (vane) | Design No: 40 |
'M' Series Electric Motors (Type M4). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A37 (single, excl. 04E), PV2R2 (vane, special design). Output: 5.5/7.5/11/15/18.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
'M' Series Electric Motors (Type M4). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A37 (single, excl. 04E), PV2R2 (vane, special design). Output: 5.5/7.5/11/15/18.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| M4-5.5-40 | M Series motor M4, 5.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M4 | Mounting: Coupling / separate housing (커플링) | Output: 5.5 kW x 4P | Electrical: 200V-50Hz: 23.4A rated / 200A start / 1465rpm; 200V-60Hz: 21.4A rated / 166A start / 1760rpm; 220V-60Hz: 20.6A rated / 183A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 65 kg | Applicable Pumps: A37 (single, excl. 04E), PV2R2 (vane, special design) | Design No: 40 | |
| M4-7.5-40 | M Series motor M4, 7.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M4 | Mounting: Coupling / separate housing (커플링) | Output: 7.5 kW x 4P | Electrical: 200V-50Hz: 30.8A rated / 264A start / 1460rpm; 200V-60Hz: 28.6A rated / 218A start / 1755rpm; 220V-60Hz: 27.4A rated / 240A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 76 kg | Applicable Pumps: A37 (single, excl. 04E), PV2R2 (vane, special design) | Design No: 40 | |
| M4-11-40 | M Series motor M4, 11kW x 4P, Coupling / separate housing | Yuken | Motor Type: M4 | Mounting: Coupling / separate housing (커플링) | Output: 11 kW x 4P | Electrical: 200V-50Hz: 46.0A rated / 365A start / 1475rpm; 200V-60Hz: 42.0A rated / 302A start / 1770rpm; 220V-60Hz: 40.0A rated / 332A start / 1775rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 114 kg | Applicable Pumps: A37 (single, excl. 04E), PV2R2 (vane, special design) | Design No: 40 | |
| M4-15-40 | M Series motor M4, 15kW x 4P, Coupling / separate housing | Yuken | Motor Type: M4 | Mounting: Coupling / separate housing (커플링) | Output: 15 kW x 4P | Electrical: 200V-50Hz: 58.8A rated / 484A start / 1470rpm; 200V-60Hz: 55.6A rated / 408A start / 1760rpm; 220V-60Hz: 52.0A rated / 449A start / 1770rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 131 kg | Applicable Pumps: A37 (single, excl. 04E), PV2R2 (vane, special design) | Design No: 40 | |
| M4-18.5-40 | M Series motor M4, 18.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M4 | Mounting: Coupling / separate housing (커플링) | Output: 18.5 kW x 4P | Electrical: 200V-50Hz: 74.0A rated / 668A start / 1475rpm; 200V-60Hz: 69.0A rated / 524A start / 1770rpm; 220V-60Hz: 65.0A rated / 576A start / 1775rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 193 kg | Applicable Pumps: A37 (single, excl. 04E), PV2R2 (vane, special design) | Design No: 40 |
'M' Series Electric Motors (Type M5). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double). Output: 5.5/7.5/11/15/18.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
'M' Series Electric Motors (Type M5). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double). Output: 5.5/7.5/11/15/18.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| M5-5.5-40 | M Series motor M5, 5.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M5 | Mounting: Coupling / separate housing (커플링) | Output: 5.5 kW x 4P | Electrical: 200V-50Hz: 23.4A rated / 200A start / 1465rpm; 200V-60Hz: 21.4A rated / 166A start / 1760rpm; 220V-60Hz: 20.6A rated / 183A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 68 kg | Applicable Pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double) | Design No: 40 | |
| M5-7.5-40 | M Series motor M5, 7.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M5 | Mounting: Coupling / separate housing (커플링) | Output: 7.5 kW x 4P | Electrical: 200V-50Hz: 30.8A rated / 264A start / 1460rpm; 200V-60Hz: 28.6A rated / 218A start / 1755rpm; 220V-60Hz: 27.4A rated / 240A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 76 kg | Applicable Pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double) | Design No: 40 | |
| M5-11-40 | M Series motor M5, 11kW x 4P, Coupling / separate housing | Yuken | Motor Type: M5 | Mounting: Coupling / separate housing (커플링) | Output: 11 kW x 4P | Electrical: 200V-50Hz: 46.0A rated / 365A start / 1475rpm; 200V-60Hz: 42.0A rated / 302A start / 1770rpm; 220V-60Hz: 40.0A rated / 332A start / 1775rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 114 kg | Applicable Pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double) | Design No: 40 | |
| M5-15-40 | M Series motor M5, 15kW x 4P, Coupling / separate housing | Yuken | Motor Type: M5 | Mounting: Coupling / separate housing (커플링) | Output: 15 kW x 4P | Electrical: 200V-50Hz: 58.8A rated / 484A start / 1470rpm; 200V-60Hz: 55.6A rated / 408A start / 1760rpm; 220V-60Hz: 52.0A rated / 449A start / 1770rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 131 kg | Applicable Pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double) | Design No: 40 | |
| M5-18.5-40 | M Series motor M5, 18.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M5 | Mounting: Coupling / separate housing (커플링) | Output: 18.5 kW x 4P | Electrical: 200V-50Hz: 74.0A rated / 668A start / 1475rpm; 200V-60Hz: 69.0A rated / 524A start / 1770rpm; 220V-60Hz: 65.0A rated / 576A start / 1775rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 193 kg | Applicable Pumps: A37(04E)/A56 (single), A1637/A2237/A1656/A2256 (double), A37R1/A56R1 (var/fixed double) | Design No: 40 |
'M' Series Electric Motors (Type M6). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A3H16 (high-pressure piston pump). Output: 5.5/7.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
'M' Series Electric Motors (Type M6). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A3H16 (high-pressure piston pump). Output: 5.5/7.5 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| M6-5.5-40 | M Series motor M6, 5.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M6 | Mounting: Coupling / separate housing (커플링) | Output: 5.5 kW x 4P | Electrical: 200V-50Hz: 23.4A rated / 200A start / 1465rpm; 200V-60Hz: 21.4A rated / 166A start / 1760rpm; 220V-60Hz: 20.6A rated / 183A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 68 kg | Applicable Pumps: A3H16 (high-pressure piston pump) | Design No: 40 | |
| M6-7.5-40 | M Series motor M6, 7.5kW x 4P, Coupling / separate housing | Yuken | Motor Type: M6 | Mounting: Coupling / separate housing (커플링) | Output: 7.5 kW x 4P | Electrical: 200V-50Hz: 30.8A rated / 264A start / 1460rpm; 200V-60Hz: 28.6A rated / 218A start / 1755rpm; 220V-60Hz: 27.4A rated / 240A start / 1765rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 76 kg | Applicable Pumps: A3H16 (high-pressure piston pump) | Design No: 40 |
'M' Series Electric Motors (Type M7). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A3H37 (high-pressure piston pump). Output: 11/15 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
'M' Series Electric Motors (Type M7). Coupling / separate housing (커플링) mounting type for Yuken hydraulic pumps: A3H37 (high-pressure piston pump). Output: 11/15 kW x 4P. Voltage: 50Hz AC200V / 60Hz AC200/220/230V. Insulation class F. Totally enclosed, surface-cooled (IP44 / IC411 / IEC60034-1).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| M7-11-40 | M Series motor M7, 11kW x 4P, Coupling / separate housing | Yuken | Motor Type: M7 | Mounting: Coupling / separate housing (커플링) | Output: 11 kW x 4P | Electrical: 200V-50Hz: 46.0A rated / 365A start / 1475rpm; 200V-60Hz: 42.0A rated / 302A start / 1770rpm; 220V-60Hz: 40.0A rated / 332A start / 1775rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 114 kg | Applicable Pumps: A3H37 (high-pressure piston pump) | Design No: 40 | |
| M7-15-40 | M Series motor M7, 15kW x 4P, Coupling / separate housing | Yuken | Motor Type: M7 | Mounting: Coupling / separate housing (커플링) | Output: 15 kW x 4P | Electrical: 200V-50Hz: 58.8A rated / 484A start / 1470rpm; 200V-60Hz: 55.6A rated / 408A start / 1760rpm; 220V-60Hz: 52.0A rated / 449A start / 1770rpm | Insulation Class: F | Enclosure: Totally enclosed, surface-cooled (IP44, IC411, IEC60034-1) | Ambient: Indoor, -20 to +40C, RH <=100% (no condensation), altitude <=1000m | Mass (approx): 131 kg | Applicable Pumps: A3H37 (high-pressure piston pump) | Design No: 40 |
[Yuken] — AMB-EL-01 Eurocard High-Response Power Amplifier (for ELDFG-01, compensation by inquiry)
▶High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL Eurocard (3U, 100×160 mm) amplifier for the high-response valve ELDFG-01. For valve size 01 the compensation code is specified separately by inquiry (RFQ); spool form (3C2/3C40 or 3C2P) and I/O code (A–F: voltage ±10 V / current 4–20 mA / current ±10 mA, PBAT or PABT) are selected to match the valve. Max output current 2.5 A, supply DC21–28 V, 30 W, mass 280 g, open-collector alarm. Please consult with the matched ELDFG-01 specification.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL Eurocard (3U, 100×160 mm) amplifier for the high-response valve ELDFG-01. For valve size 01 the compensation code is specified separately by inquiry (RFQ); spool form (3C2/3C40 or 3C2P) and I/O code (A–F: voltage ±10 V / current 4–20 mA / current ±10 mA, PBAT or PABT) are selected to match the valve. Max output current 2.5 A, supply DC21–28 V, 30 W, mass 280 g, open-collector alarm. Please consult with the matched ELDFG-01 specification.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-01 | Yuken AMB-EL-01 Eurocard high-response amplifier for ELDFG-01 (compensation by inquiry, RFQ) | Yuken | Type: Eurocard high-response power amplifier (compensation by inquiry) | Brand: Yuken | Model: AMB-EL-01 | Function: EL (minor-feedback DC-input, Eurocard 3U) | Compatible Valve Size: 01 | Compensation: By separate inquiry (RFQ) | Spool Form: 3C2/3C40 or 3C2P (per valve) | I/O Code: A–F (voltage ±10 V / current 4–20 mA / current ±10 mA; PBAT or PABT) per valve | Max Output Current: 2.5 A | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 280 g | Alarm: open collector max DC30V/10 mA | Drives: ELDFG-01 | Design No.: 20 | Note: Compensation/spool/I/O specified per matched valve — RFQ |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFG-03 (valve size 03). Max output current 3.0 A (3Ω), command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 40 W, mass 280 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFG-03 (valve size 03). Max output current 3.0 A (3Ω), command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 40 W, mass 280 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-03-1-A-20 | Yuken AMB-EL-03-1-A-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-B-20 | Yuken AMB-EL-03-1-B-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-C-20 | Yuken AMB-EL-03-1-C-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-D-20 | Yuken AMB-EL-03-1-D-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-E-20 | Yuken AMB-EL-03-1-E-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-1-F-20 | Yuken AMB-EL-03-1-F-20 Eurocard high-response amplifier for ELDFG-03, 3C2/3C40 (overlap), comp 1, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-1-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2/3C40 (overlap) | Compensation: 1 (40/80 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-A-20 | Yuken AMB-EL-03-2P-1-A-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-B-20 | Yuken AMB-EL-03-2P-1-B-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-C-20 | Yuken AMB-EL-03-2P-1-C-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-D-20 | Yuken AMB-EL-03-2P-1-D-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-E-20 | Yuken AMB-EL-03-2P-1-E-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 | |
| AMB-EL-03-2P-1-F-20 | Yuken AMB-EL-03-2P-1-F-20 Eurocard high-response amplifier for ELDFG-03, 3C2P (zero-lap), comp 1, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-03-2P-1-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 03 | Spool Form: 3C2P (zero-lap) | Compensation: 1 (40/80 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 3.0 A (3Ω) | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 40 W | Mass: 280 g | Drives: ELDFG-03 | Design No.: 20 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-04 (valve size 04). Max output current 2.5 A, command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-04 (valve size 04). Max output current 2.5 A, command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-04-2-A-20 | Yuken AMB-EL-04-2-A-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-B-20 | Yuken AMB-EL-04-2-B-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-C-20 | Yuken AMB-EL-04-2-C-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-D-20 | Yuken AMB-EL-04-2-D-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-E-20 | Yuken AMB-EL-04-2-E-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2-F-20 | Yuken AMB-EL-04-2-F-20 Eurocard high-response amplifier for ELDFHG-04, 3C2/3C40 (overlap), comp 2, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2/3C40 (overlap) | Compensation: 2 (280 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-A-20 | Yuken AMB-EL-04-2P-2-A-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-B-20 | Yuken AMB-EL-04-2P-2-B-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-C-20 | Yuken AMB-EL-04-2P-2-C-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-D-20 | Yuken AMB-EL-04-2P-2-D-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-E-20 | Yuken AMB-EL-04-2P-2-E-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 | |
| AMB-EL-04-2P-2-F-20 | Yuken AMB-EL-04-2P-2-F-20 Eurocard high-response amplifier for ELDFHG-04, 3C2P (zero-lap), comp 2, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-04-2P-2-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 04 | Spool Form: 3C2P (zero-lap) | Compensation: 2 (280 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-04 | Design No.: 20 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-06 (valve size 06). Max output current 2.5 A, command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMB-EL is the Eurocard (single-height 3U, 100×160 mm) minor-feedback DC-input amplifier for high-response directional & flow control valves. This card drives ELDFHG-06 (valve size 06). Max output current 2.5 A, command input selectable by I/O code A–F (voltage ±10 V, current 4–20 mA, or current ±10 mA; with PBAT or PABT pilot flow), input impedance 100 kΩ (voltage) / 200 Ω (current), variable dither, slope 0.05–5 s (no slope on 2P-spool versions), open-collector alarm (max DC30V/10 mA). Supply DC21–28 V, 30 W, mass 340 g. Compensation code is matched to the valve flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMB-EL-06-3-A-20 | Yuken AMB-EL-06-3-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-B-20 | Yuken AMB-EL-06-3-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-C-20 | Yuken AMB-EL-06-3-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-D-20 | Yuken AMB-EL-06-3-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-E-20 | Yuken AMB-EL-06-3-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-3-F-20 | Yuken AMB-EL-06-3-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 3, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-3-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 3 (350 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-A-20 | Yuken AMB-EL-06-2P-3-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-B-20 | Yuken AMB-EL-06-2P-3-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-C-20 | Yuken AMB-EL-06-2P-3-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-D-20 | Yuken AMB-EL-06-2P-3-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-E-20 | Yuken AMB-EL-06-2P-3-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-3-F-20 | Yuken AMB-EL-06-2P-3-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 3, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-3-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 3 (350 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-A-20 | Yuken AMB-EL-06-4-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-B-20 | Yuken AMB-EL-06-4-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-C-20 | Yuken AMB-EL-06-4-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-D-20 | Yuken AMB-EL-06-4-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-E-20 | Yuken AMB-EL-06-4-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-4-F-20 | Yuken AMB-EL-06-4-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2/3C40 (overlap), comp 4, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-4-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2/3C40 (overlap) | Compensation: 4 (500 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: 0.05–5 s | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-A-20 | Yuken AMB-EL-06-2P-4-A-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O A | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-A-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: A (Voltage ±10 V, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-B-20 | Yuken AMB-EL-06-2P-4-B-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O B | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-B-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: B (Current 4–20 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-C-20 | Yuken AMB-EL-06-2P-4-C-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O C | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-C-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: C (Current ±10 mA, PBAT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-D-20 | Yuken AMB-EL-06-2P-4-D-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O D | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-D-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: D (Voltage ±10 V, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-E-20 | Yuken AMB-EL-06-2P-4-E-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O E | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-E-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: E (Current 4–20 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 | |
| AMB-EL-06-2P-4-F-20 | Yuken AMB-EL-06-2P-4-F-20 Eurocard high-response amplifier for ELDFHG-06, 3C2P (zero-lap), comp 4, I/O F | Yuken | Type: Eurocard high-response power amplifier | Brand: Yuken | Model: AMB-EL-06-2P-4-F-20 | Function: EL (minor-feedback DC-input, Eurocard 3U 100×160 mm) | Compatible Valve Size: 06 | Spool Form: 3C2P (zero-lap) | Compensation: 4 (500 L/min) | I/O Code: F (Current ±10 mA, PABT) | Max Output Current: 2.5 A | Slope: No slope (2P spool) | Alarm: open collector max DC30V/10 mA | Power Supply: DC21–28 V | Power Consumption: 30 W | Mass: 340 g | Drives: ELDFHG-06 | Design No.: 20 |
Yuken multifunction slope controller that outputs arbitrary 2-channel analog voltage patterns and supports both slope-constant and time-constant ramping. The two channels can be used independently and can also serve as a setter for 04E-control variable piston pumps. Output channels 2 (A, B); output range 0–+5 V / 0–±5 V / 0–+10 V / 0–±10 V (DIP-selectable); slope shapes 4 (1 linear + 3 curves, DIP-selectable); max slope time 5/20/50/100 s; setting resolution 0.1% over 0–±99.9%. Control modes: mode 1 (4-bit binary, 15 patterns) with stop mode, mode 2 (6-bit binary, 63 patterns), mode 3 (timer, 9 patterns × 4). Control input: current 10 mA/bit or voltage DC8–48 V photo-coupler isolated; output: transistor open collector max 30 V/50 mA. Settings stored in EEP-ROM (no battery). Common AC100/200V (85–260 V) 50/60 Hz, 10 VA, mass 1 kg.
Yuken multifunction slope controller that outputs arbitrary 2-channel analog voltage patterns and supports both slope-constant and time-constant ramping. The two channels can be used independently and can also serve as a setter for 04E-control variable piston pumps. Output channels 2 (A, B); output range 0–+5 V / 0–±5 V / 0–+10 V / 0–±10 V (DIP-selectable); slope shapes 4 (1 linear + 3 curves, DIP-selectable); max slope time 5/20/50/100 s; setting resolution 0.1% over 0–±99.9%. Control modes: mode 1 (4-bit binary, 15 patterns) with stop mode, mode 2 (6-bit binary, 63 patterns), mode 3 (timer, 9 patterns × 4). Control input: current 10 mA/bit or voltage DC8–48 V photo-coupler isolated; output: transistor open collector max 30 V/50 mA. Settings stored in EEP-ROM (no battery). Common AC100/200V (85–260 V) 50/60 Hz, 10 VA, mass 1 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMC-T-20 | Yuken AMC-T-20 multifunction 2-channel slope controller | Yuken | Type: Multifunction slope controller | Brand: Yuken | Model: AMC-T-20 | Output Channels: 2 (A, B) | Output Voltage Range: 0–+5 / 0–±5 / 0–+10 / 0–±10 V (DIP) | Slope Mode: slope-constant or time-constant (DIP) | Slope Shapes: 4 (1 linear + 3 curves, DIP) | Max Slope Time: 5 / 20 / 50 / 100 s (DIP) | Setting Resolution: 0.1% over 0–±99.9% | Control Modes: mode1 4-bit (15 patterns, stop mode) / mode2 6-bit (63 patterns) / mode3 timer (9×4) | Control Input: current 10 mA/bit or voltage DC8–48 V (photo-coupler isolated) | Control Output: transistor open collector max 30 V/50 mA | Data Storage: EEP-ROM (no battery) | Power Supply: AC100/200V common (85–260 V) 50/60 Hz | Power Consumption: 10 VA | Mass: 1 kg | Also usable as: setter for 04E-control variable piston pumps | Design No.: 20 |
Yuken dual-channel DC-input power amplifier for 10Ω-10Ω power-saving valves. It can drive two 10Ω solenoids simultaneously or individually for combined pressure and flow control; the front-panel controls are marked PRESS and FLOW but the two circuits are identical, so either may be used. Drives the EFBG power-saving (relief-built-in flow control) valves and the other 10Ω-series valves (EDG/EBG/ERBG/EFG/EFCG[51]), and also the A-series proportional load-sensing variable piston pumps. Max output current 1 A (10Ω solenoid), max command input DC +10 V, input impedance 10 kΩ, max gain 1 A/5 V, variable dither 100–300 mA, temperature drift 0.2 mA/°C. Common AC100V/200V supply (50/60 Hz), 120 VA, mass 4.3 kg.
Yuken dual-channel DC-input power amplifier for 10Ω-10Ω power-saving valves. It can drive two 10Ω solenoids simultaneously or individually for combined pressure and flow control; the front-panel controls are marked PRESS and FLOW but the two circuits are identical, so either may be used. Drives the EFBG power-saving (relief-built-in flow control) valves and the other 10Ω-series valves (EDG/EBG/ERBG/EFG/EFCG[51]), and also the A-series proportional load-sensing variable piston pumps. Max output current 1 A (10Ω solenoid), max command input DC +10 V, input impedance 10 kΩ, max gain 1 A/5 V, variable dither 100–300 mA, temperature drift 0.2 mA/°C. Common AC100V/200V supply (50/60 Hz), 120 VA, mass 4.3 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D2-1010-11 | Yuken AME-D2-1010-11 dual-channel power amplifier for 10ohm-10ohm power-saving valves | Yuken | Type: Dual-channel power amplifier for 10Ω-10Ω power-saving valves (pressure + flow) | Brand: Yuken | Model: AME-D2-1010-11 | Function: D2 (DC input, pressure & flow control) | Load: 1010 (10Ω × 2) | Max Output Current: 1 A (10Ω solenoid) | Max Command Input: DC +10 V | Input Impedance: 10 kΩ | Max Gain: 1 A / 5 V | Dither: variable 100–300 mA | Temp Drift: 0.2 mA/°C | Power Supply: AC 100 V/200 V common (50/60 Hz) | Power Consumption: 120 VA | External Setter: 1 kΩ | Mass: 4.3 kg | Drives: EFBG power-saving valves; 10Ω valves; A-series load-sensing piston pumps | Design No.: 11 |
Linear servo amplifier used to drive the LSVG and LSVHG series high-speed linear servo valves. Optimally designed to drive linear servo valves so the full performance of the valve can be realized. Available in DC 48 V and DC 24 V power-supply versions and in ±10 V voltage, 4–20 mA, or ±10 mA current input versions with spool-displacement monitor output. Continuous rated output current ±2 A. Servo-ON / alarm-reset control inputs, over-current and deviation-alarm outputs. Operating temperature 0–50 °C. Mass 1.8 kg.
Linear servo amplifier used to drive the LSVG and LSVHG series high-speed linear servo valves. Optimally designed to drive linear servo valves so the full performance of the valve can be realized. Available in DC 48 V and DC 24 V power-supply versions and in ±10 V voltage, 4–20 mA, or ±10 mA current input versions with spool-displacement monitor output. Continuous rated output current ±2 A. Servo-ON / alarm-reset control inputs, over-current and deviation-alarm outputs. Operating temperature 0–50 °C. Mass 1.8 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMLS-A-D48-A1-10 | AMLS amp for LSVG-03-4/10/20/40, D48, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-A-D48-B1-10 | AMLS amp for LSVG-03-4/10/20/40, D48, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-A-D48-C1-10 | AMLS amp for LSVG-03-4/10/20/40, D48, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-A-D24-A1-10 | AMLS amp for LSVG-03-4/10/20/40, D24, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-A-D24-B1-10 | AMLS amp for LSVG-03-4/10/20/40, D24, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-A-D24-C1-10 | AMLS amp for LSVG-03-4/10/20/40, D24, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-4/10/20/40 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D48-A1-10 | AMLS amp for LSVG-03-60, D48, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D48-B1-10 | AMLS amp for LSVG-03-60, D48, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D48-C1-10 | AMLS amp for LSVG-03-60, D48, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D24-A1-10 | AMLS amp for LSVG-03-60, D24, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D24-B1-10 | AMLS amp for LSVG-03-60, D24, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-B-D24-C1-10 | AMLS amp for LSVG-03-60, D24, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVG-03-60 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D48-A1-10 | AMLS amp for LSVHG-06-900, D48, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D48-B1-10 | AMLS amp for LSVHG-06-900, D48, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D48-C1-10 | AMLS amp for LSVHG-06-900, D48, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D24-A1-10 | AMLS amp for LSVHG-06-900, D24, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D24-B1-10 | AMLS amp for LSVHG-06-900, D24, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C-D24-C1-10 | AMLS amp for LSVHG-06-900, D24, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-900 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D48-A1-10 | AMLS amp for LSVHG-04-750, D48, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D48-B1-10 | AMLS amp for LSVHG-04-750, D48, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D48-C1-10 | AMLS amp for LSVHG-04-750, D48, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D24-A1-10 | AMLS amp for LSVHG-04-750, D24, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D24-B1-10 | AMLS amp for LSVHG-04-750, D24, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-C2-D24-C1-10 | AMLS amp for LSVHG-04-750, D24, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-04-750 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D48-A1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D48, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D48-B1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D48, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D48-C1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D48, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 48 V ±2.4 V (≥200 VA), continuous ±2 A (4 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D24-A1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D24, input A1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Voltage ±10 V (Ri=100 kΩ, RL≥10 kΩ) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D24-B1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D24, input B1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current 4–20 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 | |
| AMLS-D-D24-C1-10 | AMLS amp for LSVHG-06-1300 / LSVHG-10-3800, D24, input C1 | YUKEN | Series: AMLS Linear Servo Amplifier | Applied Valve: LSVHG-06-1300 / LSVHG-10-3800 | Power Supply: DC 24 V ±1.2 V (≥100 VA), continuous ±2 A (3 A peak) | Input Signal / Spool Monitor: Current ±10 mA (Ri=200 Ω, RL=100–500 Ω) | Control Inputs: Servo-ON, Alarm-reset | Outputs: Over-current, Deviation-alarm (open collector, max 50 V / 30 mA) | Ambient Temp: 0–50 °C | Humidity: 20–90 %Rh (no condensation) | Mass: 1.8 kg | Source: Yuken Cat. I-Edit0, I-19 |
Yuken compact DC24V power amplifier for 10Ω proportional solenoid valves. A newly designed circuit gives lower heat generation than earlier models in a small package. Drives the 10Ω-series proportional electro-hydraulic control valves (EDG pilot relief, EBG relief, ERBG relieving/reducing, EFG/EFCG flow control [design 51], EFBG power-saving). Max output current 1 A (10Ω solenoid), max command input DC +10 V, input impedance 10 kΩ, max gain 1 A/5 V, internal variable dither, temperature drift 0.2 mA/°C. Supply DC24V (20–30 V incl. ripple), 25 W. No power switch (operates as soon as powered — fit an external switch). External setter potentiometer 1 kΩ. Mass 0.2 kg.
Yuken compact DC24V power amplifier for 10Ω proportional solenoid valves. A newly designed circuit gives lower heat generation than earlier models in a small package. Drives the 10Ω-series proportional electro-hydraulic control valves (EDG pilot relief, EBG relief, ERBG relieving/reducing, EFG/EFCG flow control [design 51], EFBG power-saving). Max output current 1 A (10Ω solenoid), max command input DC +10 V, input impedance 10 kΩ, max gain 1 A/5 V, internal variable dither, temperature drift 0.2 mA/°C. Supply DC24V (20–30 V incl. ripple), 25 W. No power switch (operates as soon as powered — fit an external switch). External setter potentiometer 1 kΩ. Mass 0.2 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-D-10 | Yuken AMN-D-10 compact DC24V power amplifier for 10ohm proportional control valves | Yuken | Type: Compact power amplifier for 10Ω proportional control valves | Brand: Yuken | Model: AMN-D-10 | Function: DC input type | Power Supply: DC 24 V (20–30 V incl. ripple) | Max Output Current: 1 A (10Ω solenoid) | Max Command Input: DC +10 V | Input Impedance: 10 kΩ | Max Gain: 1 A / 5 V | Dither: Internal, variable | Temp Drift: 0.2 mA/°C | Power Consumption: 25 W | Power Switch: None (fit external switch) | External Setter: 1 kΩ potentiometer | Mass: 0.2 kg | Dimensions: 60 × 100 × 30 mm | Drives: 10Ω valves (EDG/EBG/ERBG/EFG/EFCG[51]/EFBG) | Design No.: 10 |
Yuken DC24V power amplifiers for the shockless-type proportional directional & flow control valve EDFG-01. Two types: AMN-G-10 is a shockless pattern (sequence-input) amplifier with selectable output patterns and slope-time setting; AMN-W-10 is a DC analog-input amplifier with a delay function. Both: max output current 1.3 A (10Ω solenoid), variable dither, temperature drift 0.2 mA/°C, supply DC24V (20–30 V incl. ripple), 25 W, mass 0.2 kg. No power switch (operates as soon as powered — fit an external switch).
Yuken DC24V power amplifiers for the shockless-type proportional directional & flow control valve EDFG-01. Two types: AMN-G-10 is a shockless pattern (sequence-input) amplifier with selectable output patterns and slope-time setting; AMN-W-10 is a DC analog-input amplifier with a delay function. Both: max output current 1.3 A (10Ω solenoid), variable dither, temperature drift 0.2 mA/°C, supply DC24V (20–30 V incl. ripple), 25 W, mass 0.2 kg. No power switch (operates as soon as powered — fit an external switch).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-G-10 | Yuken AMN-G-10 power amplifier for EDFG-01 shockless directional & flow valve | Yuken | Type: Power amplifier for shockless directional & flow control valve (EDFG-01) | Brand: Yuken | Model: AMN-G-10 | Function: G (shockless / pattern type) | Max Output Current: 1.3 A (10Ω solenoid) | Features: Sequence-input shockless control: setting resolution 0–99% in 1% steps, 3 output patterns each for SOL a and SOL b, slope (ramp) time 1–99 s (0–99% adjust). Sequence input 10 mA/24 V, input voltage range 10–28 V. | Dither: variable | Temp Drift: 0.2 mA/°C | Power Supply: DC24V (20–30 V incl. ripple) | Power Consumption: 25 W | Mass: 0.2 kg | Drives: EDFG-01 shockless directional & flow valve | Design No.: 10 | |
| AMN-W-10 | Yuken AMN-W-10 power amplifier for EDFG-01 shockless directional & flow valve | Yuken | Type: Power amplifier for shockless directional & flow control valve (EDFG-01) | Brand: Yuken | Model: AMN-W-10 | Function: W (DC input / analog type) | Max Output Current: 1.3 A (10Ω solenoid) | Features: DC analog input: SOL a at DC -10 V, SOL b at DC +10 V; input impedance 10 kΩ, max gain 1.3 A/±5 V, delay-time adjustment 0.1–3 s. | Dither: variable | Temp Drift: 0.2 mA/°C | Power Supply: DC24V (20–30 V incl. ripple) | Power Consumption: 25 W | Mass: 0.2 kg | Drives: EDFG-01 shockless directional & flow valve | Design No.: 10 |
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMN-L is the compact minor-feedback DC-input amplifier for the high-response direct-operated directional & flow control valve ELDFG-01. Max output current 2.5 A (3.9Ω solenoid), command input ±10 V (P→B→A→T / P→A→B→T), input impedance ≥10 kΩ, variable dither, slope 0.03–5 s, spool-displacement monitor ±1.5 V/±3 mm, open-collector alarm (max DC30V/10 mA). Supply DC24V (20–30 V incl. ripple), 75 W, mass 300 g. The compensation code matches the spool (1 = 3C2/3C40, 3 = 3C2P).
High Response Type Power Amplifiers For Directional and Flow Control Valves. AMN-L is the compact minor-feedback DC-input amplifier for the high-response direct-operated directional & flow control valve ELDFG-01. Max output current 2.5 A (3.9Ω solenoid), command input ±10 V (P→B→A→T / P→A→B→T), input impedance ≥10 kΩ, variable dither, slope 0.03–5 s, spool-displacement monitor ±1.5 V/±3 mm, open-collector alarm (max DC30V/10 mA). Supply DC24V (20–30 V incl. ripple), 75 W, mass 300 g. The compensation code matches the spool (1 = 3C2/3C40, 3 = 3C2P).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-L-01-1-10 | Yuken AMN-L-01-1-10 compact high-response amplifier for ELDFG-01, comp 1, 3C2/3C40 (overlap) | Yuken | Type: Compact high-response power amplifier (ELDFG-01) | Brand: Yuken | Model: AMN-L-01-1-10 | Function: L (minor-feedback DC-input directional/flow) | Compatible Valve Size: 01 | Compensation: 1 | Spool Form: 3C2/3C40 (overlap) | Max Output Current: 2.5 A (3.9Ω) | Command Input: ±10 V | Slope: 0.03–5 s | Spool Monitor: ±1.5 V/±3 mm | Alarm: open collector max DC30V/10 mA | Power Supply: DC24V (20–30 V incl. ripple) | Power Consumption: 75 W | Mass: 300 g | Drives: ELDFG-01 | Design No.: 10 | |
| AMN-L-01-3-2P-10 | Yuken AMN-L-01-3-2P-10 compact high-response amplifier for ELDFG-01, comp 3, 3C2P (zero-lap) | Yuken | Type: Compact high-response power amplifier (ELDFG-01) | Brand: Yuken | Model: AMN-L-01-3-2P-10 | Function: L (minor-feedback DC-input directional/flow) | Compatible Valve Size: 01 | Compensation: 3 | Spool Form: 3C2P (zero-lap) | Max Output Current: 2.5 A (3.9Ω) | Command Input: ±10 V | Slope: 0.03–5 s | Spool Monitor: ±1.5 V/±3 mm | Alarm: open collector max DC30V/10 mA | Power Supply: DC24V (20–30 V incl. ripple) | Power Consumption: 75 W | Mass: 300 g | Drives: ELDFG-01 | Design No.: 10 |
Yuken compact, lightweight slope controller — about 1/5 the weight and 1/4 the volume of the earlier slope controller, with one-touch (plug-in) wiring. A 4-bit switching signal selects arbitrary level and acceleration/deceleration-time output patterns. Output channels 1; output voltage range 0–+5 V (factory), 0–+10 V, ±5 V, ±10 V; max slope time 1–9999 s (slope-constant or time-constant, 1 s steps); slope shapes 1 linear + 3 curves; setting resolution 0.1% over 0–±99.9%; 4-bit binary input giving 15 output patterns. Sequence input 10 mA/24 V (10–28 V range), sequence output 50 mA / 32 V. Supply DC24V (20–30 V incl. ripple), 3 W, mass 0.2 kg.
Yuken compact, lightweight slope controller — about 1/5 the weight and 1/4 the volume of the earlier slope controller, with one-touch (plug-in) wiring. A 4-bit switching signal selects arbitrary level and acceleration/deceleration-time output patterns. Output channels 1; output voltage range 0–+5 V (factory), 0–+10 V, ±5 V, ±10 V; max slope time 1–9999 s (slope-constant or time-constant, 1 s steps); slope shapes 1 linear + 3 curves; setting resolution 0.1% over 0–±99.9%; 4-bit binary input giving 15 output patterns. Sequence input 10 mA/24 V (10–28 V range), sequence output 50 mA / 32 V. Supply DC24V (20–30 V incl. ripple), 3 W, mass 0.2 kg.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMN-T-10 | Yuken AMN-T-10 compact 1-channel slope controller | Yuken | Type: Compact slope controller | Brand: Yuken | Model: AMN-T-10 | Output Channels: 1 | Output Voltage Range: 0–+5 / 0–+10 / ±5 / ±10 V | Max Slope Time: 1–9999 s (slope- or time-constant, 1 s steps) | Slope Shapes: 1 linear + 3 curves | Setting Resolution: 0.1% over 0–±99.9% | Output Patterns: 4-bit binary input → 15 patterns | Sequence Input: 10 mA/24 V (10–28 V range) | Sequence Output: 50 mA / 32 V max | Power Supply: DC24V (20–30 V incl. ripple) | Power Consumption: 3 W | Mass: 0.2 kg | Features: 1/5 weight & 1/4 volume vs previous, one-touch wiring | Design No.: 10 |
Two-input (voltage-input) servo amplifier with an auxiliary input (AUX) for configuring a minor loop. Supplies an external ±12 V regulated voltage, allowing simple connection to setters or detectors such as potentiometers. Full model code AMS-※-S-20; variant field by RFQ / consultation.
Two-input (voltage-input) servo amplifier with an auxiliary input (AUX) for configuring a minor loop. Supplies an external ±12 V regulated voltage, allowing simple connection to setters or detectors such as potentiometers. Full model code AMS-※-S-20; variant field by RFQ / consultation.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AMS-S-20 | AMS Servo Amplifier (full code AMS-※-S-20, RFQ) | YUKEN | Type: Servo amplifier (2-input, voltage input) | Features: Auxiliary input (AUX) for minor loop; external ±12 V regulated supply for setters/potentiometers | Full Model Code: AMS-※-S-20 (※ variant field by RFQ/consultation) | Ordering: Exact designation by RFQ / consultation | Source: Yuken Cat. I-Edit0, I-63 |
Yuken dedicated power amplifiers that drive the proportional solenoids of 10Ω-series proportional electro-hydraulic control valves (e.g. EDG pilot relief, EBG relief, ERBG relieving/reducing), converting a command signal into a proportional solenoid drive current. Available as AC-powered rack types (AME-D-10, SK1022-A/B with command-feedback) and a compact DC24V lead-wire type (SK1015). The full order code carries a valve-matching option (※) specified per matched valve.
Yuken dedicated power amplifiers that drive the proportional solenoids of 10Ω-series proportional electro-hydraulic control valves (e.g. EDG pilot relief, EBG relief, ERBG relieving/reducing), converting a command signal into a proportional solenoid drive current. Available as AC-powered rack types (AME-D-10, SK1022-A/B with command-feedback) and a compact DC24V lead-wire type (SK1015). The full order code carries a valve-matching option (※) specified per matched valve.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D-10 | Yuken AME-D-10 power amplifier for 10ohm proportional control valves, AC 100/200 V, Rack type | Yuken | Type: Power amplifier for 10Ω proportional control valves | Brand: Yuken | Model: AME-D-10 | Order Code: AME-D-10-※-20 (※ = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200 V | Form: Rack type | Features: Manual-setter (MC-01) compatible, MAX/zero/dither adjustment, output-current meter; +12V internal supply | Dimensions: 80 × 199 × 185.5 mm | Drives: 10Ω proportional control valves (EDG / EBG / ERBG) | |
| SK1022-A | Yuken SK1022-A power amplifier for 10ohm proportional control valves, AC 100/200/220 V, Rack type (feedback) | Yuken | Type: Power amplifier for 10Ω proportional control valves | Brand: Yuken | Model: SK1022-A | Order Code: SK1022-A-※-11 (※ = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200/220 V | Form: Rack type (feedback) | Features: Feedback type (REF/F.B), gain/null/dither and reference/input-ratio adjustment, output-current meter | Dimensions: 125 × 199 × 260 mm | Drives: 10Ω proportional control valves (EDG / EBG / ERBG) | |
| SK1022-B | Yuken SK1022-B power amplifier for 10ohm proportional control valves, AC 100/200/220 V, Rack type (feedback) | Yuken | Type: Power amplifier for 10Ω proportional control valves | Brand: Yuken | Model: SK1022-B | Order Code: SK1022-B-※-11 (※ = valve-matching option, specify per valve / RFQ) | Power Supply: AC 100/200/220 V | Form: Rack type (feedback) | Features: Feedback type (REF/F.B), gain/null/dither and reference/input-ratio adjustment, output-current meter | Dimensions: 125 × 199 × 260 mm | Drives: 10Ω proportional control valves (EDG / EBG / ERBG) | |
| SK1015 | Yuken SK1015 power amplifier for 10ohm proportional control valves, DC 24 V, Compact lead-wire type | Yuken | Type: Power amplifier for 10Ω proportional control valves | Brand: Yuken | Model: SK1015 | Order Code: SK1015-11 (※ = valve-matching option, specify per valve / RFQ) | Power Supply: DC 24 V | Form: Compact lead-wire type | Features: Compact lead-wire amplifier, zero/gain adjustment; no power switch (operates as soon as power applied — fit external switch). Setter potentiometer 10 kΩ | Dimensions: 120 × 85 × 45 mm | Drives: 10Ω proportional control valves (EDG / EBG / ERBG) |
Yuken dedicated power amplifiers that drive the proportional solenoids of 40Ω-series flow control valves (EFG/EFCG, design 31/26/22/11). The AME-D type is a DC-command-input amplifier and AME-DF adds command feedback; both are available in wall-mount (D only) or panel-mount and with AC (85–230 V) or DC (20–55 V) supply. The AME-T type is an acceleration/deceleration-signal amplifier with adjustable ramp (0.05–1 s per 100 mA), AC100V or AC200/220V supply. Max output current 0.8 A (40Ω solenoid; 1.0 A for 10Ω), factory-set max output 0.8 A.
Yuken dedicated power amplifiers that drive the proportional solenoids of 40Ω-series flow control valves (EFG/EFCG, design 31/26/22/11). The AME-D type is a DC-command-input amplifier and AME-DF adds command feedback; both are available in wall-mount (D only) or panel-mount and with AC (85–230 V) or DC (20–55 V) supply. The AME-T type is an acceleration/deceleration-signal amplifier with adjustable ramp (0.05–1 s per 100 mA), AC100V or AC200/220V supply. Max output current 0.8 A (40Ω solenoid; 1.0 A for 10Ω), factory-set max output 0.8 A.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| AME-D-AC-50 | Yuken AME-D-AC-50 power amplifier for 40ohm flow control valves, DC command-input type, Wall mount, AC 85–230 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-D-AC-50 | Function: D (DC command-input type) | Mounting: Wall mount | Power Supply: AC 85–230 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 1.1 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-DC-50 | Yuken AME-D-DC-50 power amplifier for 40ohm flow control valves, DC command-input type, Wall mount, DC 20–55 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-D-DC-50 | Function: D (DC command-input type) | Mounting: Wall mount | Power Supply: DC 20–55 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 1.1 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-S-AC-50 | Yuken AME-D-S-AC-50 power amplifier for 40ohm flow control valves, DC command-input type, Panel mount, AC 85–230 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-D-S-AC-50 | Function: D (DC command-input type) | Mounting: Panel mount | Power Supply: AC 85–230 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 2.1 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-D-S-DC-50 | Yuken AME-D-S-DC-50 power amplifier for 40ohm flow control valves, DC command-input type, Panel mount, DC 20–55 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-D-S-DC-50 | Function: D (DC command-input type) | Mounting: Panel mount | Power Supply: DC 20–55 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 2.1 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-DF-S-AC-50 | Yuken AME-DF-S-AC-50 power amplifier for 40ohm flow control valves, DC command-input feedback type, Panel mount, AC 85–230 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-DF-S-AC-50 | Function: DF (DC command-input feedback type) | Mounting: Panel mount | Power Supply: AC 85–230 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) ; Feedback input DC ±10 V (differential) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 2.2 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-DF-S-DC-50 | Yuken AME-DF-S-DC-50 power amplifier for 40ohm flow control valves, DC command-input feedback type, Panel mount, DC 20–55 V | Yuken | Type: Power amplifier for 40Ω flow control valves | Brand: Yuken | Model: AME-DF-S-DC-50 | Function: DF (DC command-input feedback type) | Mounting: Panel mount | Power Supply: DC 20–55 V | Max Output Current: 0.8 A (40Ω solenoid) / 1.0 A (10Ω); factory-set 0.8 A | Max Command Input: DC +10 V (single-end) ; Feedback input DC ±10 V (differential) | Input Impedance: 10 kΩ | Current Monitor: 5 V/A | Dither: variable | Temp Drift: 0.2 mA/°C | Power Consumption: 50 W | Mass: 2.2 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 50 | |
| AME-T-S-100-22 | Yuken AME-T-S-100-22 accel/decel power amplifier for 40ohm flow control valves, AC 100 V | Yuken | Type: Power amplifier for 40Ω flow control valves (accel/decel signal type) | Brand: Yuken | Model: AME-T-S-100-22 | Function: T (acceleration/deceleration signal type) | Mounting: Panel mount | Power Supply: AC 100 V ±10% (50/60 Hz) | Max Output Current: 0.8 A (40Ω solenoid) | Accel/Decel Ramp: 0.05–1 s / 100 mA | Dither: fixed | Temp Drift: 0.2 mA/°C | Power Consumption: 90 VA | Mass: 4.5 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 22 | |
| AME-T-S-200-22 | Yuken AME-T-S-200-22 accel/decel power amplifier for 40ohm flow control valves, AC 200/220 V | Yuken | Type: Power amplifier for 40Ω flow control valves (accel/decel signal type) | Brand: Yuken | Model: AME-T-S-200-22 | Function: T (acceleration/deceleration signal type) | Mounting: Panel mount | Power Supply: AC 200/220 V ±10% (50/60 Hz) | Max Output Current: 0.8 A (40Ω solenoid) | Accel/Decel Ramp: 0.05–1 s / 100 mA | Dither: fixed | Temp Drift: 0.2 mA/°C | Power Consumption: 90 VA | Mass: 4.5 kg | Drives: 40Ω EFG/EFCG flow control valves | Design No.: 22 |
Yuken setting adjusters that supply the command-signal voltage to proportional-control power amplifiers. As setting depends on the actual operating method, setters are normally built to customer request; the following are sold as standard products. MC-01 is the simplest manual dial setter (single 1 kΩ volume); MC-02 is a centre-tapped manual dial setter (1 kΩ·1 kΩ) suited to servo systems; AMC-V6 is a 6-point setter for individual setting of six points. Use the setter potentiometer impedance specified for each amplifier (typically 1–2 kΩ).
Yuken setting adjusters that supply the command-signal voltage to proportional-control power amplifiers. As setting depends on the actual operating method, setters are normally built to customer request; the following are sold as standard products. MC-01 is the simplest manual dial setter (single 1 kΩ volume); MC-02 is a centre-tapped manual dial setter (1 kΩ·1 kΩ) suited to servo systems; AMC-V6 is a 6-point setter for individual setting of six points. Use the setter potentiometer impedance specified for each amplifier (typically 1–2 kΩ).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| MC-01 | Yuken MC-01 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: MC-01 | Description: Manual dial setting adjuster with a single 1 kΩ volume, dial and scale; the simplest setter. Panel-mount, mass 0.5 kg. | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier | |
| MC-02 | Yuken MC-02 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: MC-02 | Description: Manual dial setting adjuster with a centre-tapped volume (1 kΩ · 1 kΩ), dial and scale; suited to servo systems. | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier | |
| AMC-V6-S-10 | Yuken AMC-V6-S-10 setting adjuster for proportional control amplifiers | Yuken | Type: Setting adjuster for proportional-control amplifiers | Brand: Yuken | Model: AMC-V6-S-10 | Description: 6-point setter with six volumes, allowing individual setting of six points. Full order code AMC-V6-S-※-10 (※ = option, specify by inquiry / RFQ). | Mounting: Panel mount | Function: Supplies command-signal voltage to the power amplifier |