Hydraulics
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 750 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 750 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04EH-750-2-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 100/200/280/450 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 100/200/280/450 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04EH-100-S4-A | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-B | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-C | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-D | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-E | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-F | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-D | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-E | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-F | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-A | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-B | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-C | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-D | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-E | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-F | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-D | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-E | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-F | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-A | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-B | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-C | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-D | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-E | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-F | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-D | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-E | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-F | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-A | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-B | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-C | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-D | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-E | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-F | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-D | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-E | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-F | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 1300 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 1300 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06-1300-2-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 2, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 1 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-1300-40-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 40, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 2 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-1300-2P-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 2P, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 900 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 900 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06-900-2-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 2, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-900-40-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 40, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 1.8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-900-2P-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 2P, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 7 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 1300 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 1300 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-1300-2-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 820 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 820 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-820-4J-A | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-B | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-C | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-D | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-E | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-F | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 900 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 900 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-900-2-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 500/900 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 500/900 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-500-S4-A | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-B | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-C | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-D | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-E | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-F | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-D | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-E | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-F | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-A | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-B | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-C | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-D | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-E | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-F | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-D | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-E | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-F | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 3800 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 3800 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-10-3800-2-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 2, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 3 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-10-3800-40-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 40, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 6 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-10-3800-2P-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 2P, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 10 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| GCT-02-34 | Needle Valve GCT-02-34, inline type, threaded | Yuken | Type: Needle Valve | Configuration: Inline type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 | |
| GCTR-02-34 | Needle Valve GCTR-02-34, angle type, threaded | Yuken | Type: Needle Valve | Configuration: Angle type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 |
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| SRCT-03-50 | One Way Restrictor SRCT-03, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 1.5 kg | Design No.: 50 | |
| SRCT-06-50 | One Way Restrictor SRCT-06, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.8 kg | Design No.: 50 | |
| SRCT-10-50 | One Way Restrictor SRCT-10, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 9.1 kg | Design No.: 50 | |
| SRCG-03-50 | One Way Restrictor SRCG-03, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 2.5 kg | Design No.: 50 | |
| SRCG-06-50 | One Way Restrictor SRCG-06, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.9 kg | Design No.: 50 | |
| SRCG-10-50 | One Way Restrictor SRCG-10, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 7.5 kg | Design No.: 50 |
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 10.0 cm3/rev. Min. adjustable flow: 2.0 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 0.75/1.5 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 10.0 cm3/rev. Min. adjustable flow: 2.0 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 0.75/1.5 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PM10-01B-0.75-31 | PAL Pump PM10, 0.75kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM10 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 10.0 cm3/rev | Min Adjustable Flow: 2.0 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 0.75 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 28.1 kg | Design No: 31 | |
| PM10-01B-1.5-31 | PAL Pump PM10, 1.5kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM10 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 10.0 cm3/rev | Min Adjustable Flow: 2.0 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 1.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 41.8 kg | Design No: 31 | |
| PM10-01C-1.5-31 | PAL Pump PM10, 1.5kW, pressure range C (2~16 MPa) | Yuken | Series: PM10 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 10.0 cm3/rev | Min Adjustable Flow: 2.0 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 1.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 41.8 kg | Design No: 31 |
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 15.8 cm3/rev. Min. adjustable flow: 6.0 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 1.5/2.2 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 15.8 cm3/rev. Min. adjustable flow: 6.0 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 1.5/2.2 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PM16-01B-1.5-30 | PAL Pump PM16, 1.5kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM16 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 15.8 cm3/rev | Min Adjustable Flow: 6.0 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 1.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 39.5 kg | Design No: 30 | |
| PM16-01C-1.5-30 | PAL Pump PM16, 1.5kW, pressure range C (2~16 MPa) | Yuken | Series: PM16 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 15.8 cm3/rev | Min Adjustable Flow: 6.0 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 1.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 39.5 kg | Design No: 30 | |
| PM16-01B-2.2-30 | PAL Pump PM16, 2.2kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM16 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 15.8 cm3/rev | Min Adjustable Flow: 6.0 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 2.2 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 43.6 kg | Design No: 30 | |
| PM16-01C-2.2-30 | PAL Pump PM16, 2.2kW, pressure range C (2~16 MPa) | Yuken | Series: PM16 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 15.8 cm3/rev | Min Adjustable Flow: 6.0 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 2.2 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 43.6 kg | Design No: 30 |
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 22.2 cm3/rev. Min. adjustable flow: 8.5 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 2.2/3.7 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 22.2 cm3/rev. Min. adjustable flow: 8.5 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 2.2/3.7 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PM22-01B-2.2-30 | PAL Pump PM22, 2.2kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM22 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 22.2 cm3/rev | Min Adjustable Flow: 8.5 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 2.2 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 43.6 kg | Design No: 30 | |
| PM22-01C-2.2-30 | PAL Pump PM22, 2.2kW, pressure range C (2~16 MPa) | Yuken | Series: PM22 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 22.2 cm3/rev | Min Adjustable Flow: 8.5 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 2.2 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 43.6 kg | Design No: 30 | |
| PM22-01B-3.7-30 | PAL Pump PM22, 3.7kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM22 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 22.2 cm3/rev | Min Adjustable Flow: 8.5 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 3.7 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 64.0 kg | Design No: 30 | |
| PM22-01C-3.7-30 | PAL Pump PM22, 3.7kW, pressure range C (2~16 MPa) | Yuken | Series: PM22 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 22.2 cm3/rev | Min Adjustable Flow: 8.5 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 3.7 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 64.0 kg | Design No: 30 |
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 36.9 cm3/rev. Min. adjustable flow: 10 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 3.7/5.5 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
PAL Pump, Pressure Compensator Type (PM series motor-pump). Theoretical displacement: 36.9 cm3/rev. Min. adjustable flow: 10 cm3/rev. Pressure adjustment range: B 1.2-7 MPa / C 2-16 MPa. Motor: 3.7/5.5 kW x 4P, 50Hz AC200V / 60Hz AC200/220/230V. Control type: 01 (pressure compensator).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PM37-01B-3.7-30 | PAL Pump PM37, 3.7kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM37 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 36.9 cm3/rev | Min Adjustable Flow: 10 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 3.7 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 72.0 kg | Design No: 30 | |
| PM37-01C-3.7-30 | PAL Pump PM37, 3.7kW, pressure range C (2~16 MPa) | Yuken | Series: PM37 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 36.9 cm3/rev | Min Adjustable Flow: 10 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 3.7 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 72.0 kg | Design No: 30 | |
| PM37-01B-5.5-30 | PAL Pump PM37, 5.5kW, pressure range B (1.2~7 MPa) | Yuken | Series: PM37 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 36.9 cm3/rev | Min Adjustable Flow: 10 cm3/rev | Pressure Range Code: B (1.2~7 MPa) | Max Working Pressure: 7 MPa | Motor Output: 5.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 74.0 kg | Design No: 30 | |
| PM37-01C-5.5-30 | PAL Pump PM37, 5.5kW, pressure range C (2~16 MPa) | Yuken | Series: PM37 | Type: Motor-Pump (variable piston pump + motor) | Control: 01 Pressure Compensator | Theoretical Displacement: 36.9 cm3/rev | Min Adjustable Flow: 10 cm3/rev | Pressure Range Code: C (2~16 MPa) | Max Working Pressure: 16 MPa | Motor Output: 5.5 kW x 4P | Motor Voltage: 50Hz AC200V / 60Hz AC200/220/230V | Mass (approx): 74.0 kg | Design No: 30 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHCG-02-30-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-03-125-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-06-250-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-10-500-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHG-02-30-13 | Pilot Operated Flow Control Valve FHG-02-30 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-O-13 | Pilot Operated Flow Control Valve FHG-02-30-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-13 | Pilot Operated Flow Control Valve FHG-02-30-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-O-13 | Pilot Operated Flow Control Valve FHG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-03-125-13 | Pilot Operated Flow Control Valve FHG-03-125 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-O-13 | Pilot Operated Flow Control Valve FHG-03-125-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-13 | Pilot Operated Flow Control Valve FHG-03-125-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-O-13 | Pilot Operated Flow Control Valve FHG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-06-250-13 | Pilot Operated Flow Control Valve FHG-06-250 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-O-13 | Pilot Operated Flow Control Valve FHG-06-250-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-13 | Pilot Operated Flow Control Valve FHG-06-250-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-O-13 | Pilot Operated Flow Control Valve FHG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-10-500-13 | Pilot Operated Flow Control Valve FHG-10-500 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-O-13 | Pilot Operated Flow Control Valve FHG-10-500-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-13 | Pilot Operated Flow Control Valve FHG-10-500-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-O-13 | Pilot Operated Flow Control Valve FHG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |
Pilot Operated Relief Valves. Max. operating pressure: 25 MPa. Pressure adjustment range: to 25 MPa. Max. flow: 100 L/min (03) / 200 L/min (06) / 400 L/min (10). High-vent type (-V) available. Threaded (BT) / sub-plate (BG).
Pilot Operated Relief Valves. Max. operating pressure: 25 MPa. Pressure adjustment range: to 25 MPa. Max. flow: 100 L/min (03) / 200 L/min (06) / 400 L/min (10). High-vent type (-V) available. Threaded (BT) / sub-plate (BG).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BT-03-32 | Pilot Operated Relief Valve BT-03, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 03 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-03-V-32 | Pilot Operated Relief Valve BT-03-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 03 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-06-32 | Pilot Operated Relief Valve BT-06, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 06 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-06-V-32 | Pilot Operated Relief Valve BT-06-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 06 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-10-32 | Pilot Operated Relief Valve BT-10, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 10 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.5 kg | Design No.: 32 | |
| BT-10-V-32 | Pilot Operated Relief Valve BT-10-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 10 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.5 kg | Design No.: 32 | |
| BG-03-32 | Pilot Operated Relief Valve BG-03, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 03 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 4.7 kg | Design No.: 32 | |
| BG-03-V-32 | Pilot Operated Relief Valve BG-03-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 03 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 4.7 kg | Design No.: 32 | |
| BG-06-32 | Pilot Operated Relief Valve BG-06, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 06 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.6 kg | Design No.: 32 | |
| BG-06-V-32 | Pilot Operated Relief Valve BG-06-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 06 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.6 kg | Design No.: 32 | |
| BG-10-32 | Pilot Operated Relief Valve BG-10, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 10 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.7 kg | Design No.: 32 | |
| BG-10-V-32 | Pilot Operated Relief Valve BG-10-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 10 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.7 kg | Design No.: 32 |
Power Package (Motor-Driven Integrated Type). YUKEN's power package compactly integrates a small high-pressure vane pump, relief valve and oil tank, and allows a hydraulic circuit to be configured simply by stacking 1/8 solenoid valves (or manual selector valves) and modular valves. The PMR2 is a motor-driven (motor-integrated) package driven on AC 200/220 V, suited to small machines and general industrial machinery. Circuits can be added or changed simply by adding or changing the modular valves stacked on the package, and the package can be used immediately just by hydraulic piping between it and the actuator. Fifteen standard circuits are available (see Yuken Cat. K-48/K-49). Solenoid valves use the DSG-01 series; manual selector valves use the DMG-01 series. Tank capacity 3.4 L. Relief setting range 3.5-14 MPa (specify as MPa x 10). Pump rotation is clockwise viewed from the motor fan side. Order code: PMR2-{size}-{relief}-{motor A/B/N}-{circuit 00-08}-{valve}-40.
Power Package (Motor-Driven Integrated Type). YUKEN's power package compactly integrates a small high-pressure vane pump, relief valve and oil tank, and allows a hydraulic circuit to be configured simply by stacking 1/8 solenoid valves (or manual selector valves) and modular valves. The PMR2 is a motor-driven (motor-integrated) package driven on AC 200/220 V, suited to small machines and general industrial machinery. Circuits can be added or changed simply by adding or changing the modular valves stacked on the package, and the package can be used immediately just by hydraulic piping between it and the actuator. Fifteen standard circuits are available (see Yuken Cat. K-48/K-49). Solenoid valves use the DSG-01 series; manual selector valves use the DMG-01 series. Tank capacity 3.4 L. Relief setting range 3.5-14 MPa (specify as MPa x 10). Pump rotation is clockwise viewed from the motor fan side. Order code: PMR2-{size}-{relief}-{motor A/B/N}-{circuit 00-08}-{valve}-40.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| PMR2-6-A | PMR2 motor-driven power package, 5.8cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 5.8 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-6-B | PMR2 motor-driven power package, 5.8cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 5.8 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-8-A | PMR2 motor-driven power package, 8.0cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 8.0 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-8-B | PMR2 motor-driven power package, 8.0cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 8.0 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-10-A | PMR2 motor-driven power package, 9.4cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 9.4 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-10-B | PMR2 motor-driven power package, 9.4cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 9.4 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-12-A | PMR2 motor-driven power package, 12.2cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 12.2 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-12-B | PMR2 motor-driven power package, 12.2cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 12.2 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-14-A | PMR2 motor-driven power package, 13.7cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 13.7 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-14-B | PMR2 motor-driven power package, 13.7cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 13.7 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-17-A | PMR2 motor-driven power package, 16.6cm3, 1.5 kW x 6P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 16.6 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 1.5 kW x 6P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 36 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 | |
| PMR2-17-B | PMR2 motor-driven power package, 16.6cm3, 2.2 kW x 4P, 14 MPa | YUKEN | Type: Power Package, Motor-Driven Integrated Type | Pump Displacement: 16.6 cm3/rev | Max Use Pressure: 14 MPa | Relief Setting Range: 3.5-14 MPa (specify as MPa x 10) | Motor: 2.2 kW x 4P, AC200V 50Hz / AC220V 60Hz | Pump Rotation: Clockwise (viewed from motor fan side) | Tank Capacity: 3.4 L | Mass: 51.5 kg (incl. oil, circuit 00 no valve) | Circuit: 00 (no valve) or 01-08 standard circuits (Cat. K-48/49) | Selector Valve: Manual DMG-01 (M) or Solenoid DSG-01 (coil D12/D24/A100/A200); no symbol for circuit 00/08 | Design No.: 40 |
Port flange kit for Yuken PM series motor-pumps (ordered separately; PM10 does not use port flanges). Available for PM16/PM22 (suction port) and PM37 (suction & delivery ports) in Rc threaded, socket weld, or butt weld types.
Port flange kit for Yuken PM series motor-pumps (ordered separately; PM10 does not use port flanges). Available for PM16/PM22 (suction port) and PM37 (suction & delivery ports) in Rc threaded, socket weld, or butt weld types.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| F5-06-A-1021 | Port flange kit for PM16/PM22, Suction port, Rc threaded | Yuken | Applicable Pump: PM16/PM22 | Port: Suction port | Flange Type: Rc threaded | Note: Ordered separately; not included with pump | |
| F5-06-B-1021 | Port flange kit for PM16/PM22, Suction port, Socket weld | Yuken | Applicable Pump: PM16/PM22 | Port: Suction port | Flange Type: Socket weld | Note: Ordered separately; not included with pump | |
| F5-10-A-10 | Port flange kit for PM37, Suction & delivery port, Rc threaded | Yuken | Applicable Pump: PM37 | Port: Suction & delivery port | Flange Type: Rc threaded | Note: Ordered separately; not included with pump | |
| F5-10-B-10 | Port flange kit for PM37, Suction & delivery port, Socket weld | Yuken | Applicable Pump: PM37 | Port: Suction & delivery port | Flange Type: Socket weld | Note: Ordered separately; not included with pump | |
| F5-10-C-10 | Port flange kit for PM37, Suction & delivery port, Butt weld | Yuken | Applicable Pump: PM37 | Port: Suction & delivery port | Flange Type: Butt weld | Note: Ordered separately; not included with pump |