On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 230 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 230 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-03EH-230-2L-A | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-230-2L-B | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-230-2L-C | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-230-2L-D | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-230-2L-E | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-230-2L-F | LSVHG-03EH-230 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 230 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 120 Hz (100) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±4 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 270 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 270 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-03EH-270-2-A | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2-B | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2-C | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2-D | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2-E | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2-F | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-A | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-B | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-C | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-D | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-E | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-40-F | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-A | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-B | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-C | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-D | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-E | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-03EH-270-2P-F | LSVHG-03EH-270 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 03 (ISO 4401-05) | Rated Flow (ΔP=7MPa): 270 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥9 (8) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 7 ms (9) | Frequency Resp. (−3 dB gain): 125 Hz (110) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 60/100/160 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 60/100/160 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-03EH-60-S4-A | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S4-B | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S4-C | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S4-D | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S4-E | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S4-F | LSVHG-03EH-60 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S3-D | LSVHG-03EH-60 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S3-E | LSVHG-03EH-60 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-60-S3-F | LSVHG-03EH-60 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 60 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-A | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-B | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-C | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-D | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-E | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S4-F | LSVHG-03EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S3-D | LSVHG-03EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S3-E | LSVHG-03EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-100-S3-F | LSVHG-03EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 0.6 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-A | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-B | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-C | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-D | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-E | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S4-F | LSVHG-03EH-160 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 2.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S3-D | LSVHG-03EH-160 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S3-E | LSVHG-03EH-160 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-03EH-160-S3-F | LSVHG-03EH-160 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 03 (ISO 4401-05) | Rated Flow: 160 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (T): 21 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥4 L/min | Main Valve Internal Leakage: 1.1 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 7 ms (8) | Frequency Resp. (−3 dB gain): 110 Hz (80) | Frequency Resp. (−90° phase): 110 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 1.3 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 8.5 [11] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 750 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C2 linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 750 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C2 linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04-750-2-10 | LSVHG-04-750 2-Stage Linear Servo Valve, spool 2, 750 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 04 | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 31.5 / 31.5 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥27 (22) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 0.8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 150 Hz (140) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7.1 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 12 kg | Mounting Bolts: M6×55L ×2 (12.9–15.9 N·m) + M10×60L ×4 (60.6–74.1 N·m) | Dedicated Amplifier: AMLS-C2-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-04-750-40-10 | LSVHG-04-750 2-Stage Linear Servo Valve, spool 40, 750 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 04 | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 31.5 / 31.5 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥27 (22) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 1.6 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 150 Hz (140) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7.1 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 12 kg | Mounting Bolts: M6×55L ×2 (12.9–15.9 N·m) + M10×60L ×4 (60.6–74.1 N·m) | Dedicated Amplifier: AMLS-C2-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-04-750-2P-10 | LSVHG-04-750 2-Stage Linear Servo Valve, spool 2P, 750 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 04 | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 31.5 / 31.5 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥27 (22) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 6.8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 150 Hz (140) | Frequency Resp. (−90° phase): 110 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7.1 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 12 kg | Mounting Bolts: M6×55L ×2 (12.9–15.9 N·m) + M10×60L ×4 (60.6–74.1 N·m) | Dedicated Amplifier: AMLS-C2-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 580 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 580 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04EH-580-4J-A | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-580-4J-B | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-580-4J-C | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-580-4J-D | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-580-4J-E | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-580-4J-F | LSVHG-04EH-580 2-Stage OBE Servo Valve, spool 4J, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 580 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 750 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 750 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04EH-750-2-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-40-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2P-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-A | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-B | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-C | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-D | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-E | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-04EH-750-2L-F | LSVHG-04EH-750 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 04 (ISO 4401-07) | Rated Flow (ΔP=7MPa): 750 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥20 (17) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 7 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 100/200/280/450 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 100/200/280/450 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-04EH-100-S4-A | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-B | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-C | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-D | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-E | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S4-F | LSVHG-04EH-100 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-D | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-E | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-100-S3-F | LSVHG-04EH-100 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 100 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-A | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-B | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-C | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-D | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-E | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S4-F | LSVHG-04EH-200 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.7 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-D | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-E | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-200-S3-F | LSVHG-04EH-200 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 200 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-A | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-B | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-C | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-D | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-E | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S4-F | LSVHG-04EH-280 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-D | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-E | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-280-S3-F | LSVHG-04EH-280 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 280 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 1.3 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-A | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-B | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-C | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-D | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-E | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S4-F | LSVHG-04EH-450 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 5.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-D | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-E | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-04EH-450-S3-F | LSVHG-04EH-450 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 04 (ISO 4401-07) | Rated Flow: 450 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 31.5 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥6 L/min | Main Valve Internal Leakage: 2.5 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 11 ms (12) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 100 Hz (90) | Main Spool Rated Stroke: ±3.5 mm | Main Spool Pressure Area: 3.1 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 14 [16] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 1300 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 1300 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06-1300-2-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 2, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 1 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-1300-40-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 40, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 2 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-1300-2P-10 | LSVHG-06-1300 2-Stage Linear Servo Valve, spool 2P, 1300 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure (ext./int. drain): 25 / 25 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥34 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 10 ms (13) | Frequency Resp. (−3 dB gain): 150 Hz (110) | Frequency Resp. (−90° phase): 100 Hz (100) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 21 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 900 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 900 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-C linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06-900-2-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 2, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 0.9 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-900-40-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 40, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 1.8 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-06-900-2P-10 | LSVHG-06-900 2-Stage Linear Servo Valve, spool 2P, 900 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 06 | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 35 / 35 MPa | Pilot Supply Pressure: 1.5–35 MPa | Pilot Flow: ≥30 (24) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 7 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 8 ms (10) | Frequency Resp. (−3 dB gain): 160 Hz (130) | Frequency Resp. (−90° phase): 105 Hz (100) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 20 kg | Mounting Bolts: M12×85L ×6 (104–127 N·m) | Dedicated Amplifier: AMLS-C-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 1300 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 1300 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-1300-2-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-40-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2P-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-2L-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 75 Hz (70) | Frequency Resp. (−90° phase): 70 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-A | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-B | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-C | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-D | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-E | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-1300-4J-F | LSVHG-06EH-1300 2-Stage OBE Servo Valve, spool 4J, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 1300 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 820 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 820 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-820-4J-A | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-B | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-C | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-D | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-E | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-820-4J-F | LSVHG-06EH-820 2-Stage OBE Servo Valve, spool 4J, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 820 L/min | Spool Type: 4J (A,B,T connected, neutral; +100% input: A/B/C→P→A, D/E/F→P→B) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): input A/B/C → A (PABT full-open); input D/E/F → blank (PBAT full-open) or EC (solenoid, neutral) | Max Operating Pressure: 31.5 MPa | Tank Port Pressure: 25 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥23 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | 4J Characteristic: see characteristic curves (I-44/46/48) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 900 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
On-board electronic (OBE) two-stage linear servo valve, based on the two-stage high-speed linear servo valve with a miniaturized pilot stage and a compact integrated dedicated amplifier, realizing 'high precision, simple, convenient'. Rated flow 900 L/min. Hysteresis 0.1% or less. DC 24 V supply with command-signal input only; built-in fault-diagnosis indicator. Dry and wet pilot types selectable. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Input-signal versions ±10 V / 4–20 mA / ±10 mA with spool monitor.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-900-2-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2 | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EC (solenoid valve attached, neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-40-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 40, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 40 (A,B,T connected at neutral) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2P-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2P, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): blank=PBAT full-open / A=PABT full-open (no solenoid) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-A | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input A | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-B | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input B | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-C | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input C | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-D | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input D | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-E | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input E | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 | |
| LSVHG-06EH-900-2L-F | LSVHG-06EH-900 2-Stage OBE Servo Valve, spool 2L, input F | YUKEN | Type: Two-stage (pilot-operated), on-board electronic (OBE) amp-mounted | Valve Frame: 06 (ISO 4401-08) | Rated Flow (ΔP=7MPa): 900 L/min | Spool Type: 2L | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (per spool): EA (solenoid, PBAT 10% open) / EB (solenoid, PABT 10% open) | Max Operating Pressure: 35 MPa | Tank Port Pressure: 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥22 (19) L/min | Drain Port DR Back Pressure: 0.05 MPa max (W type: no DR port, wet) | Step Response (0↔100%): 11 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (90) | Frequency Resp. (−90° phase): 90 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V (DC 21.6–26.4 V incl. ripple) | Linear Motor: 2.1 A max, coil 9.6 Ω | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain | Connector (select): 1=6+PE / 2=11+PE (Enable, valve-ready, alarm output) | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-31/I-32/I-33 |
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 500/900 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
High-performance on-board electronic (OBE) two-stage linear servo valve. Based on the standard-type OBE linear servo valve with an added sleeve; spool and sleeve are machined together to ensure a precise 1% overlap, suiting systems that demand higher precision and durability. Hysteresis 0.1% or less; step response from 7 ms. 1% overlap spool (form S), available as 3-way (A-port) or 4-way valve. Rated flow 500/900 L/min. DC 24 V supply, command-signal input only, built-in fault-diagnosis indicator. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Note: 3-way version accepts input signals D/E/F only.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-06EH-500-S4-A | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-B | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-C | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-D | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-E | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S4-F | LSVHG-06EH-500 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.9 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-D | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-E | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-500-S3-F | LSVHG-06EH-500 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 500 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 1.0 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-A | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input A | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: A: Voltage ±10 V (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-B | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input B | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: B: Current 4–20 mA (12–20 mA → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-C | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input C | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: C: Current ±10 mA (+input → PBAT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-D | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-E | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S4-F | LSVHG-06EH-900 High-Perf OBE Servo Valve, S4 (4-way valve), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=7MPa) | Spool / Control: S (1% overlap) / 4-way valve | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open / A=PABT full-open / EA=sol PBAT 10% / EB=sol PABT 10% | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 4.8 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-D | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input D | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: D: Voltage ±10 V (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-E | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input E | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: E: Current 4–20 mA (12–20 mA → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 | |
| LSVHG-06EH-900-S3-F | LSVHG-06EH-900 High-Perf OBE Servo Valve, S3 (3-way valve (A-port, ΔP=3.5MPa rating)), input F | YUKEN | Type: Two-stage (pilot-operated) OBE, high-performance (sleeve-type, 1% overlap) | Valve Frame: 06 (ISO 4401-08) | Rated Flow: 900 L/min (ΔP=3.5MPa) | Spool / Control: S (1% overlap) / 3-way valve (A-port, ΔP=3.5MPa rating) | Input Signal / Spool Monitor: F: Current ±10 mA (+input → PABT flow) | Safety Device (select): blank=PBAT full-open (no solenoid) / EB=sol PABT 10% [★ 3-way: input D/E/F only] | Max Operating Pressure: 35 MPa | Tank Port Pressure (T): 35 MPa | Pilot Supply Pressure: 1.5–21 MPa | Pilot Flow: ≥21 L/min | Main Valve Internal Leakage: 2.4 L/min (14MPa, 32mm²/s) | Step Response (0↔100%): 12 ms (13) | Frequency Resp. (−3 dB gain): 100 Hz (80) | Frequency Resp. (−90° phase): 95 Hz (90) | Main Spool Rated Stroke: ±5 mm | Main Spool Pressure Area: 8 cm² | Built-in Amplifier: On-board (OBE), DC 24 V | Pilot / Drain Form: Internal pilot+ext drain (std) / E=ext pilot / T=int drain / W=no DR port (wet) | Connector (select): 1=6+PE / 2=11+PE | Hysteresis: 0.1% max | Protection: IP65 | Ambient Temp: 0 to +50 °C | Mass: 20 [24] kg ([ ] = with safety solenoid valve) | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals); W type not for water-glycol | Source: Yuken Cat. I-Edit0, I-52/I-53 |
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 3800 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
Two-stage high-speed linear servo valve in which a direct-type high-speed linear servo valve acts as the pilot stage driving the main spool, achieving a large flow rate of 3800 L/min (ΔP=7MPa). Electrical feedback control of both the pilot spool position and the main spool position realizes high precision and high response. Hysteresis 0.1% or less. Usable to NAS 1638 class 10 (ISO4406 21/19/15). Available spool types 2 / 40 / 2P. Requires dedicated AMLS-D linear servo amplifier.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| LSVHG-10-3800-2-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 2, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 2 (10% overlap) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 3 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-10-3800-40-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 40, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 40 (A,B,T connected at neutral) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 6 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 | |
| LSVHG-10-3800-2P-20 | LSVHG-10-3800 2-Stage Linear Servo Valve, spool 2P, 3800 L/min | YUKEN | Type: Two-stage (pilot-operated), linear servo | Valve Size: 10 | Rated Flow (ΔP=7MPa): 3800 L/min | Spool Type: 2P (zero-lap, dual flow gain) | Max Operating Pressure: 35 MPa | Tank Port Pressure (ext./int. drain): 28 / 28 MPa | Pilot Supply Pressure: 1.5–25 MPa | Pilot Flow: ≥32 (27) L/min | Drain Port DR Back Pressure: 0.05 MPa max | Main Valve Internal Leakage: 10 L/min (14MPa, 32mm²/s) | Hysteresis: 0.1% max | Step Response (0↔100%): 15 ms (18) | Frequency Resp. (−3 dB gain): 100 Hz (60) | Frequency Resp. (−90° phase): 85 Hz (75) | Main Spool Rated Stroke: ±7 mm | Main Spool Pressure Area: 11.3 cm² | Linear Motor: 2 A (6 A max), coil 4.5 Ω @20°C | Protection: IP64 | Ambient Temp: −15 to +60 °C | Mass: 78 kg | Mounting Bolts: M20×90L ×6 (494–603 N·m) | Dedicated Amplifier: AMLS-D-D48/D24 | Pilot / Drain Form: Internal pilot+external drain (std) / E=external pilot / T=internal drain | Cable Port Direction: Top (std) / R / L — select per order | Safety Device: PBAT-open (std) / A=PABT-open | Fluid: Mineral oil (std) / Phosphate-ester (F prefix, fluoro seals) | Source: Yuken Cat. I-Edit0, I-10/I-11 |
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| GCT-02-34 | Needle Valve GCT-02-34, inline type, threaded | Yuken | Type: Needle Valve | Configuration: Inline type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 | |
| GCTR-02-34 | Needle Valve GCTR-02-34, angle type, threaded | Yuken | Type: Needle Valve | Configuration: Angle type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 |
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| SRCT-03-50 | One Way Restrictor SRCT-03, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 1.5 kg | Design No.: 50 | |
| SRCT-06-50 | One Way Restrictor SRCT-06, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.8 kg | Design No.: 50 | |
| SRCT-10-50 | One Way Restrictor SRCT-10, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 9.1 kg | Design No.: 50 | |
| SRCG-03-50 | One Way Restrictor SRCG-03, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 2.5 kg | Design No.: 50 | |
| SRCG-06-50 | One Way Restrictor SRCG-06, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.9 kg | Design No.: 50 | |
| SRCG-10-50 | One Way Restrictor SRCG-10, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 7.5 kg | Design No.: 50 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHCG-02-30-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-03-125-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-06-250-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-10-500-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHG-02-30-13 | Pilot Operated Flow Control Valve FHG-02-30 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-O-13 | Pilot Operated Flow Control Valve FHG-02-30-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-13 | Pilot Operated Flow Control Valve FHG-02-30-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-O-13 | Pilot Operated Flow Control Valve FHG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-03-125-13 | Pilot Operated Flow Control Valve FHG-03-125 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-O-13 | Pilot Operated Flow Control Valve FHG-03-125-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-13 | Pilot Operated Flow Control Valve FHG-03-125-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-O-13 | Pilot Operated Flow Control Valve FHG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-06-250-13 | Pilot Operated Flow Control Valve FHG-06-250 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-O-13 | Pilot Operated Flow Control Valve FHG-06-250-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-13 | Pilot Operated Flow Control Valve FHG-06-250-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-O-13 | Pilot Operated Flow Control Valve FHG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-10-500-13 | Pilot Operated Flow Control Valve FHG-10-500 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-O-13 | Pilot Operated Flow Control Valve FHG-10-500-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-13 | Pilot Operated Flow Control Valve FHG-10-500-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-O-13 | Pilot Operated Flow Control Valve FHG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |
Pilot Operated Relief Valves. Max. operating pressure: 25 MPa. Pressure adjustment range: to 25 MPa. Max. flow: 100 L/min (03) / 200 L/min (06) / 400 L/min (10). High-vent type (-V) available. Threaded (BT) / sub-plate (BG).
Pilot Operated Relief Valves. Max. operating pressure: 25 MPa. Pressure adjustment range: to 25 MPa. Max. flow: 100 L/min (03) / 200 L/min (06) / 400 L/min (10). High-vent type (-V) available. Threaded (BT) / sub-plate (BG).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| BT-03-32 | Pilot Operated Relief Valve BT-03, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 03 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-03-V-32 | Pilot Operated Relief Valve BT-03-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 03 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-06-32 | Pilot Operated Relief Valve BT-06, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 06 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-06-V-32 | Pilot Operated Relief Valve BT-06-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 06 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.0 kg | Design No.: 32 | |
| BT-10-32 | Pilot Operated Relief Valve BT-10, Threaded | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 10 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.5 kg | Design No.: 32 | |
| BT-10-V-32 | Pilot Operated Relief Valve BT-10-V, Threaded, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Threaded | Valve Size: 10 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.5 kg | Design No.: 32 | |
| BG-03-32 | Pilot Operated Relief Valve BG-03, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 03 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 4.7 kg | Design No.: 32 | |
| BG-03-V-32 | Pilot Operated Relief Valve BG-03-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 03 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 100 L/min | Mass: 4.7 kg | Design No.: 32 | |
| BG-06-32 | Pilot Operated Relief Valve BG-06, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 06 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.6 kg | Design No.: 32 | |
| BG-06-V-32 | Pilot Operated Relief Valve BG-06-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 06 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 200 L/min | Mass: 5.6 kg | Design No.: 32 | |
| BG-10-32 | Pilot Operated Relief Valve BG-10, Sub-plate | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 10 | High-Vent Type: No | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.7 kg | Design No.: 32 | |
| BG-10-V-32 | Pilot Operated Relief Valve BG-10-V, Sub-plate, high-vent | Yuken | Type: Pilot Operated Relief Valve | Mounting: Sub-plate | Valve Size: 10 | High-Vent Type: Yes (-V) | Max. Operating Pressure: 25 MPa | Pressure Adjustment Range: to 25 MPa | Max. Flow: 400 L/min | Mass: 8.7 kg | Design No.: 32 |
Pressure Monitoring System — Digital Pressure Monitors (DP) and Pressure Sensors (SJT). Monitor input 0–4.5V / 0–19.6 MPa (DP20), 0–34.3 MPa (DP35). Output: 2× open collector, 40V·100 mA. 2-channel HI/LO 4-point independent setting. Sensor rated pressure 0–20 MPa (SJT20) / 0–35 MPa (SJT35), output 0.5–4.5V, supply DC 5.0±0.5V. System configuration: consult Yuken (RFQ).
Pressure Monitoring System — Digital Pressure Monitors (DP) and Pressure Sensors (SJT). Monitor input 0–4.5V / 0–19.6 MPa (DP20), 0–34.3 MPa (DP35). Output: 2× open collector, 40V·100 mA. 2-channel HI/LO 4-point independent setting. Sensor rated pressure 0–20 MPa (SJT20) / 0–35 MPa (SJT35), output 0.5–4.5V, supply DC 5.0±0.5V. System configuration: consult Yuken (RFQ).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| DP20-10 | Digital Pressure Monitor DP20 | Yuken | Type: Digital Pressure Monitor | Input: 0–4.5V / 0–19.6 MPa | Output: 2× open collector, 40V·100 mA | Setting: 2-channel HI/LO, 4-point independent | Options (RFQ): consult Yuken | |
| DP35-10 | Digital Pressure Monitor DP35 | Yuken | Type: Digital Pressure Monitor | Input: 0–4.5V / 0–34.3 MPa | Output: 2× open collector, 40V·100 mA | Setting: 2-channel HI/LO, 4-point independent | Options (RFQ): consult Yuken | |
| SJT20-02-10 | Pressure Sensor SJT20 | Yuken | Type: Pressure Sensor | Rated Pressure: 0–20 MPa | Output: 0.5–4.5V | Supply: DC 5.0±0.5V | |
| SJT35-02-10 | Pressure Sensor SJT35 | Yuken | Type: Pressure Sensor | Rated Pressure: 0–35 MPa | Output: 0.5–4.5V | Supply: DC 5.0±0.5V |