Flow Control Valves
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 60/125 L/min. Pilot-relief pressure range C: 1.2–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-60-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-E-50 | EHFBG-03 Power-Saving, 60L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-C-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-60-H-E-S-50 | EHFBG-03 Power-Saving, 60L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Flow Adj. Range: 1–60 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-E-50 | EHFBG-03 Power-Saving, 125L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-C-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range C (1.2–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-125-H-E-S-50 | EHFBG-03 Power-Saving, 125L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.6 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 03. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.6–15.7 MPa / H: 1.8–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-03-250-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-E-50 | EHFBG-03-250 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-C-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.6–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-03-250-H-E-S-50 | EHFBG-03-250 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.8–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.8 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 250 L/min. Pilot-relief pressure range C: 1.4–15.7 MPa / H: 1.4–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-250-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-E-50 | EHFBG-06 Power-Saving, 250L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-C-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range C (1.4–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-250-H-E-S-50 | EHFBG-06 Power-Saving, 250L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Flow Adj. Range: 2.5–250 L/min | Pilot Relief Pressure: Range H (1.4–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.7 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow version of the EHFBG power-saving valve with roughly double the max flow of the standard series (03: 125→250, 06: 250→500 L/min) and a one-step smaller valve size for a more compact installation. Supplies only the minimum pressure and flow needed to drive the actuator, with temperature-compensated meter-in flow control. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. With/without pilot relief, internal/external flow pilot, optional pressure sensor. Coil 10Ω, DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-06-500-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-E-50 | EHFBG-06-500 High-Flow Power-Saving, no pilot relief valve (flow control only), External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-C-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief C, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-06-500-H-E-S-50 | EHFBG-06-500 High-Flow Power-Saving, pilot relief H, open loop + sensor, External pilot | Yuken | Type: High-Flow Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG (High Flow) | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control and Relief Valves. Energy-saving valve that supplies only the minimum pressure and flow required to drive the actuator, controlling pump pressure according to load to lower power consumption; a meter-in flow-adjusting valve with built-in temperature compensation for stable flow control regardless of oil temperature. Sub-plate mounting, valve size 10. Max operating pressure 24.5 MPa, max flow 500 L/min. Pilot-relief pressure range C: 1.5–15.7 MPa / H: 1.5–24.5 MPa. Versions with/without built-in pilot relief, internal/external flow pilot, and optional pressure sensor. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-500-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: Internal pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-E-50 | EHFBG-10 Power-Saving, 500L/min, no pilot relief valve (flow control only), External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: None (no pilot relief valve) | Flow-control Pilot: External pilot | Pressure-control: None | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-C-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief C, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range C (1.5–15.7 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, Internal pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: Internal pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFBG-10-500-H-E-S-50 | EHFBG-10 Power-Saving, 500L/min, pilot relief H, open loop + sensor, External pilot | Yuken | Type: Proportional Power-Saving Valve (Flow Control + Relief) | Series: EHFBG | Mounting: Sub-plate (G) | Valve Size: 10 | Max Adjustable Flow: 500 L/min | Flow Adj. Range: 5–500 L/min | Pilot Relief Pressure: Range H (1.5–24.5 MPa) | Flow-control Pilot: External pilot | Pressure-control: Open loop + built-in sensor | Valve Pressure Drop: 0.9 MPa | Max Pressure: 24.5 MPa | Coil: 10Ω, DC24V | Design No.: 50 |
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
High Flow Series Proportional Electro-Hydraulic Flow Control and Relief Valves. High-flow EHFBG with 1000 L/min maximum flow. This variant is available on request; detailed model-code options are supplied by separate inquiry (RFQ). Max operating pressure 24.5 MPa.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFBG-10-1000 | EHFBG-10-1000 High-Flow Power-Saving, 1000 L/min, available by separate inquiry (RFQ) | Yuken | Type: High-Flow Proportional Power-Saving Valve | Series: EHFBG (High Flow) | Valve Size: 10 | Max Adjustable Flow: 1000 L/min | Max Pressure: 24.5 MPa | Availability: Made to order — full options by separate inquiry (RFQ) |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFCG-03-60-50 | EHFCG-03 Flow Control +Check, 60L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-60-E-50 | EHFCG-03 Flow Control +Check, 60L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-125-50 | EHFCG-03 Flow Control +Check, 125L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-03-125-E-50 | EHFCG-03 Flow Control +Check, 125L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Free Flow (check): 130 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature . Built-in check valve. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFCG-06-250-50 | EHFCG-06 Flow Control +Check, 250L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Free Flow (check): 280 L/min | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFCG-06-250-E-50 | EHFCG-06 Flow Control +Check, 250L/min, External pilot | Yuken | Type: Proportional Flow Control Valve with built-in Check | Series: EHFCG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Free Flow (check): 280 L/min | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 03. Max operating pressure 20.6 MPa, max adjustable flow 60 / 125 L/min, min adjustable flow 1 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFG-03-60-50 | EHFG-03 Flow Control, 60L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-60-E-50 | EHFG-03 Flow Control, 60L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 60 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-125-50 | EHFG-03 Flow Control, 125L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-03-125-E-50 | EHFG-03 Flow Control, 125L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Min Adjustable Flow: 1 L/min | Max Pressure: 20.6 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
Proportional Electro-Hydraulic Flow Control (and Check) Valves. Remotely controls system flow proportionally to the input voltage; pressure- and temperature-compensated so the set flow is unaffected by load pressure or oil temperature. Sub-plate mounting, valve size 06. Max operating pressure 24.5 MPa, max adjustable flow 250 L/min, min adjustable flow 2.5 L/min. Internal- and external-pilot (E) versions. Coil resistance 10Ω, supply DC24V (28W max).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| EHFG-06-250-50 | EHFG-06 Flow Control, 250L/min, Internal pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Pilot: Internal pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 | |
| EHFG-06-250-E-50 | EHFG-06 Flow Control, 250L/min, External pilot | Yuken | Type: Proportional Flow Control Valve | Series: EHFG | Mounting: Sub-plate (G) | Valve Size: 06 | Max Adjustable Flow: 250 L/min | Min Adjustable Flow: 2.5 L/min | Max Pressure: 24.5 MPa | Pilot: External pilot | Pressure/Temperature compensated: Yes | Coil: 10Ω, DC24V | Design No.: 50 |
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ω) while the pressure-control system is current-driven (coil 10Ω). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 125 L/min (1–125 L/min). Pilot-relief pressure range C: 1.6–16 MPa. Internal/external pilot. Hysteresis 0.5%.
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ω) while the pressure-control system is current-driven (coil 10Ω). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 125 L/min (1–125 L/min). Pilot-relief pressure range C: 1.6–16 MPa. Internal/external pilot. Hysteresis 0.5%.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELFBG-03-125-C-10 | ELFBG-03-125 High-Performance Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (1.6–16 MPa) | Pressure-control Rated Current: 890 mA | Pilot: Internal pilot | Flow-control: Voltage input DC10V, coil 4Ω, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ω | Valve Pressure Drop: 0.6–0.8 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 | |
| ELFBG-03-125-C-E-10 | ELFBG-03-125 High-Performance Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 125 L/min | Flow Adj. Range: 1–125 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (1.6–16 MPa) | Pressure-control Rated Current: 890 mA | Pilot: External pilot | Flow-control: Voltage input DC10V, coil 4Ω, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ω | Valve Pressure Drop: 0.6–0.8 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 |
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ω) while the pressure-control system is current-driven (coil 10Ω). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 170 L/min (1–170 L/min). Pilot-relief pressure range C: 2.3–18 MPa. Internal/external pilot. Hysteresis 0.5%.
High-Performance Proportional Electro-Hydraulic Flow Control and Relief Valves. E-series energy-saving valve that supplies only the minimum pressure and flow needed to drive the actuator; a temperature-stable meter-in flow-adjusting valve with a built-in differential transformer (LVDT) that detects throttle position for stable, high-accuracy flow control. The flow-control system is voltage-driven (DC10V input, coil 4Ω) while the pressure-control system is current-driven (coil 10Ω). Use with a dedicated Yuken power amplifier. Sub-plate mounting, valve size 03. Max operating pressure 25 MPa, max flow 170 L/min (1–170 L/min). Pilot-relief pressure range C: 2.3–18 MPa. Internal/external pilot. Hysteresis 0.5%.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| ELFBG-03-170-C-10 | ELFBG-03-170 High-Performance Power-Saving (E), pilot relief C, Internal pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 170 L/min | Flow Adj. Range: 1–170 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (2.3–18 MPa) | Pressure-control Rated Current: 970 mA | Pilot: Internal pilot | Flow-control: Voltage input DC10V, coil 4Ω, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ω | Valve Pressure Drop: 0.85–1 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 | |
| ELFBG-03-170-C-E-10 | ELFBG-03-170 High-Performance Power-Saving (E), pilot relief C, External pilot | Yuken | Type: High-Performance Proportional Power-Saving Valve (Flow Control + Relief, E series) | Series: ELFBG | Mounting: Sub-plate (G) | Valve Size: 03 | Max Adjustable Flow: 170 L/min | Flow Adj. Range: 1–170 L/min | Max Pressure: 25 MPa | Pilot Relief Pressure: C (2.3–18 MPa) | Pressure-control Rated Current: 970 mA | Pilot: External pilot | Flow-control: Voltage input DC10V, coil 4Ω, LVDT spool-position feedback | Pressure-control: Current input, coil 10Ω | Valve Pressure Drop: 0.85–1 MPa | Hysteresis: 0.5% | Drive: Use with dedicated power amplifier | Design No.: 10 |
Feed Control Valves. Compact combination of flow control + check valve and deceleration valve for machine-tool rapid→feed switching by cam. Pressure/temperature compensated. Max. operating pressure: 14 MPa. 1-stage control type. Sizes 01/03/04. Deceleration valve max. flow A:12 / B:8 / C:4 L/min (size 01). Internal / external (-E) drain.
Feed Control Valves. Compact combination of flow control + check valve and deceleration valve for machine-tool rapid→feed switching by cam. Pressure/temperature compensated. Max. operating pressure: 14 MPa. 1-stage control type. Sizes 01/03/04. Deceleration valve max. flow A:12 / B:8 / C:4 L/min (size 01). Internal / external (-E) drain.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UCF1G-01-4-A-11 | Feed Control Valve UCF1G-01-4-A-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: A (12 L/min) | Max. Flow: 16 (12 at ≥7 MPa) L/min | Adjustment Range: 0.03–4 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-4-A-E-11 | Feed Control Valve UCF1G-01-4-A-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: A (12 L/min) | Max. Flow: 16 (12 at ≥7 MPa) L/min | Adjustment Range: 0.03–4 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-4-B-11 | Feed Control Valve UCF1G-01-4-B-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: B (8 L/min) | Max. Flow: 12 (8) L/min | Adjustment Range: 0.05–4 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-4-B-E-11 | Feed Control Valve UCF1G-01-4-B-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: B (8 L/min) | Max. Flow: 12 (8) L/min | Adjustment Range: 0.05–4 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-4-C-11 | Feed Control Valve UCF1G-01-4-C-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: C (4 L/min) | Max. Flow: 8 (4) L/min | Adjustment Range: 0.05–4 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-4-C-E-11 | Feed Control Valve UCF1G-01-4-C-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 4 L/min | Deceleration Valve Max. Flow: C (4 L/min) | Max. Flow: 8 (4) L/min | Adjustment Range: 0.05–4 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-A-11 | Feed Control Valve UCF1G-01-8-A-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: A (12 L/min) | Max. Flow: 20 (12) L/min | Adjustment Range: 0.03–8 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-A-E-11 | Feed Control Valve UCF1G-01-8-A-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: A (12 L/min) | Max. Flow: 20 (12) L/min | Adjustment Range: 0.03–8 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-B-11 | Feed Control Valve UCF1G-01-8-B-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: B (8 L/min) | Max. Flow: 16 (8) L/min | Adjustment Range: 0.05–8 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-B-E-11 | Feed Control Valve UCF1G-01-8-B-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: B (8 L/min) | Max. Flow: 16 (8) L/min | Adjustment Range: 0.05–8 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-C-11 | Feed Control Valve UCF1G-01-8-C-11, internal drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: C (4 L/min) | Max. Flow: 12 (4) L/min | Adjustment Range: 0.05–8 L/min | Free Flow: 20 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-01-8-C-E-11 | Feed Control Valve UCF1G-01-8-C-E-11, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 01 | Adjustable Flow: 8 L/min | Deceleration Valve Max. Flow: C (4 L/min) | Max. Flow: 12 (4) L/min | Adjustment Range: 0.05–8 L/min | Free Flow: 20 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 1.6 kg | Design No.: 11 | |
| UCF1G-03-4-10 | Feed Control Valve UCF1G-03-4-10, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 4 L/min | Max. Flow: 40 L/min | Adjustment Range: 0.05–4 L/min | Free Flow: 40 L/min | Drain: External | Max. Operating Pressure: 14 MPa | Mass: 2.6 kg | Design No.: 10 | |
| UCF1G-03-8-10 | Feed Control Valve UCF1G-03-8-10, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 8 L/min | Max. Flow: 40 L/min | Adjustment Range: 0.05–8 L/min | Free Flow: 40 L/min | Drain: External | Max. Operating Pressure: 14 MPa | Mass: 2.6 kg | Design No.: 10 | |
| UCF1G-04-30-30 | Feed Control Valve UCF1G-04-30-30, external drain | Yuken | Type: Feed Control Valve (1-stage) | Mounting: Gasket | Valve Size: 04 | Adjustable Flow: 30 L/min | Max. Flow: 80 (40) L/min | Adjustment Range: 0.1–22 L/min | Free Flow: 80 L/min | Drain: External | Max. Operating Pressure: 14 MPa | Mass: 6.5 kg | Design No.: 30 |
Feed Control Valves. Compact combination of flow control + check valve and deceleration valve for machine-tool rapid→feed switching by cam. Pressure/temperature compensated. Max. operating pressure: 14 MPa. 2-stage control type. Sizes 03/04. Internal / external (-E) drain.
Feed Control Valves. Compact combination of flow control + check valve and deceleration valve for machine-tool rapid→feed switching by cam. Pressure/temperature compensated. Max. operating pressure: 14 MPa. 2-stage control type. Sizes 03/04. Internal / external (-E) drain.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| UCF2G-03-4-10 | Feed Control Valve UCF2G-03-4-10, internal drain | Yuken | Type: Feed Control Valve (2-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 4 L/min | Max. Flow: 40 L/min | Adjustment Range 1st Stage: 0.1–4 L/min | Adjustment Range 2nd Stage: 0.05–4 L/min | Free Flow: 40 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 2.7 kg | Design No.: 10 | |
| UCF2G-03-4-E-10 | Feed Control Valve UCF2G-03-4-E-10, external drain | Yuken | Type: Feed Control Valve (2-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 4 L/min | Max. Flow: 40 L/min | Adjustment Range 1st Stage: 0.1–4 L/min | Adjustment Range 2nd Stage: 0.05–4 L/min | Free Flow: 40 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 2.7 kg | Design No.: 10 | |
| UCF2G-03-8-10 | Feed Control Valve UCF2G-03-8-10, internal drain | Yuken | Type: Feed Control Valve (2-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 8 L/min | Max. Flow: 40 L/min | Adjustment Range 1st Stage: 0.1–8 L/min | Adjustment Range 2nd Stage: 0.05–8 L/min | Free Flow: 40 L/min | Drain: Internal | Max. Operating Pressure: 14 MPa | Mass: 2.7 kg | Design No.: 10 | |
| UCF2G-03-8-E-10 | Feed Control Valve UCF2G-03-8-E-10, external drain | Yuken | Type: Feed Control Valve (2-stage) | Mounting: Gasket | Valve Size: 03 | Adjustable Flow: 8 L/min | Max. Flow: 40 L/min | Adjustment Range 1st Stage: 0.1–8 L/min | Adjustment Range 2nd Stage: 0.05–8 L/min | Free Flow: 40 L/min | Drain: External (-E) | Max. Operating Pressure: 14 MPa | Mass: 2.7 kg | Design No.: 10 | |
| UCF2G-04-30-30 | Feed Control Valve UCF2G-04-30-30, external drain | Yuken | Type: Feed Control Valve (2-stage) | Mounting: Gasket | Valve Size: 04 | Adjustable Flow: 30 L/min | Max. Flow: 80 (40) L/min | Adjustment Range 1st Stage: 0.1–22 L/min | Adjustment Range 2nd Stage: 0.1–17 L/min | Free Flow: 80 L/min | Drain: External | Max. Operating Pressure: 14 MPa | Mass: 9.2 kg | Design No.: 30 |
Flow Control Valves · Flow Control and Check Valves. Max. operating pressure: 14 MPa (size 01) / 21 MPa (02–10). Max. adjustable flow: 4/8 (01) / 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Digital scale (except size 01). Pressure-compensated piston opening adjustment (-N) available. Built-in check valve for free reverse flow.
Flow Control Valves · Flow Control and Check Valves. Max. operating pressure: 14 MPa (size 01) / 21 MPa (02–10). Max. adjustable flow: 4/8 (01) / 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Digital scale (except size 01). Pressure-compensated piston opening adjustment (-N) available. Built-in check valve for free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FCG-01-4-11 | Flow Control and Check Valve FCG-01-4 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 4 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FCG-01-4-N-11 | Flow Control and Check Valve FCG-01-4-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 4 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FCG-01-8-11 | Flow Control and Check Valve FCG-01-8 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 8 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FCG-01-8-N-11 | Flow Control and Check Valve FCG-01-8-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 8 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FCG-02-30-30 | Flow Control and Check Valve FCG-02-30 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 3.8 kg | Design No.: 30 | |
| FCG-02-30-N-30 | Flow Control and Check Valve FCG-02-30-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 3.8 kg | Design No.: 30 | |
| FCG-03-125-30 | Flow Control and Check Valve FCG-03-125 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 7.9 kg | Design No.: 30 | |
| FCG-03-125-N-30 | Flow Control and Check Valve FCG-03-125-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 7.9 kg | Design No.: 30 | |
| FCG-06-250-30 | Flow Control and Check Valve FCG-06-250 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 23 kg | Design No.: 30 | |
| FCG-06-250-N-30 | Flow Control and Check Valve FCG-06-250-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 23 kg | Design No.: 30 | |
| FCG-10-500-30 | Flow Control and Check Valve FCG-10-500 | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 52 kg | Design No.: 30 | |
| FCG-10-500-N-30 | Flow Control and Check Valve FCG-10-500-N | Yuken | Type: Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Mass: 52 kg | Design No.: 30 |
Flow Control Valves · Flow Control and Check Valves. Max. operating pressure: 14 MPa (size 01) / 21 MPa (02–10). Max. adjustable flow: 4/8 (01) / 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Digital scale (except size 01). Pressure-compensated piston opening adjustment (-N) available.
Flow Control Valves · Flow Control and Check Valves. Max. operating pressure: 14 MPa (size 01) / 21 MPa (02–10). Max. adjustable flow: 4/8 (01) / 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Digital scale (except size 01). Pressure-compensated piston opening adjustment (-N) available.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FG-01-4-11 | Flow Control Valve FG-01-4 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 4 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FG-01-4-N-11 | Flow Control Valve FG-01-4-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 4 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FG-01-8-11 | Flow Control Valve FG-01-8 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 8 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FG-01-8-N-11 | Flow Control Valve FG-01-8-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 01 | Max. Adjustable Flow: 8 L/min | Min. Adjustable Flow: 0.02 (0.04 at ≥7 MPa) L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 14 MPa | Mass: 1.3 kg | Design No.: 11 | |
| FG-02-30-30 | Flow Control Valve FG-02-30 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 3.8 kg | Design No.: 30 | |
| FG-02-30-N-30 | Flow Control Valve FG-02-30-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 3.8 kg | Design No.: 30 | |
| FG-03-125-30 | Flow Control Valve FG-03-125 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 7.9 kg | Design No.: 30 | |
| FG-03-125-N-30 | Flow Control Valve FG-03-125-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 7.9 kg | Design No.: 30 | |
| FG-06-250-30 | Flow Control Valve FG-06-250 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 23 kg | Design No.: 30 | |
| FG-06-250-N-30 | Flow Control Valve FG-06-250-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 23 kg | Design No.: 30 | |
| FG-10-500-30 | Flow Control Valve FG-10-500 | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 52 kg | Design No.: 30 | |
| FG-10-500-N-30 | Flow Control Valve FG-10-500-N | Yuken | Type: Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Check Valve: No | Max. Operating Pressure: 21 MPa | Mass: 52 kg | Design No.: 30 |
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
Needle Valves. Used as stop valves for pressure-gauge / small-flow lines or as throttle valves for pilot lines. Max. operating pressure: 35 MPa. Inline type (GCT) / angle type (GCTR), threaded. Adapter AG-02S/03S/04S available separately for pressure-gauge mounting (with pressure snubber).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| GCT-02-34 | Needle Valve GCT-02-34, inline type, threaded | Yuken | Type: Needle Valve | Configuration: Inline type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 | |
| GCTR-02-34 | Needle Valve GCTR-02-34, angle type, threaded | Yuken | Type: Needle Valve | Configuration: Angle type | Connection: Threaded | Valve Size: 02 | Max. Operating Pressure: 35 MPa | Mass: 0.34 kg | Adapter (separate order): AG-02S / AG-03S / AG-04S (with pressure snubber) | Design No.: 34 |
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
Restrictors · One Way Restrictors. Max. operating pressure: 25 MPa. Rated flow: 30 (03) / 85 (06) / 230 (10) L/min (at 0.3 MPa drop). Threaded (T) / sub-plate (G) mounting. Controlled flow one way, free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| SRCT-03-50 | One Way Restrictor SRCT-03, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 1.5 kg | Design No.: 50 | |
| SRCT-06-50 | One Way Restrictor SRCT-06, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.8 kg | Design No.: 50 | |
| SRCT-10-50 | One Way Restrictor SRCT-10, Threaded | Yuken | Type: One Way Restrictor | Mounting: Threaded | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 9.1 kg | Design No.: 50 | |
| SRCG-03-50 | One Way Restrictor SRCG-03, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 03 | Rated Flow: 30 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 2.5 kg | Design No.: 50 | |
| SRCG-06-50 | One Way Restrictor SRCG-06, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 06 | Rated Flow: 85 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 3.9 kg | Design No.: 50 | |
| SRCG-10-50 | One Way Restrictor SRCG-10, Sub-plate | Yuken | Type: One Way Restrictor | Mounting: Sub-plate | Valve Size: 10 | Rated Flow: 230 L/min (at 0.3 MPa drop) | Max. Operating Pressure: 25 MPa | Reverse Flow: Free (check valve) | Mass: 7.5 kg | Design No.: 50 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt). Built-in check valve for free reverse flow.
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHCG-02-30-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-02-30-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHCG-03-125-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-03-125-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHCG-06-250-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-06-250-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHCG-10-500-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500 | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHCG-10-500-N-O-13 | Pilot Operated Flow Control and Check Valve FHCG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control and Check Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: Yes (free reverse flow) | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
Pilot Operated Flow Control Valves · Pilot Operated Flow Control and Check Valves. Max. operating pressure: 21 MPa. Min. pilot pressure: 1.5 MPa. Max. adjustable flow: 30 (02) / 125 (03) / 250 (06) / 500 (10) L/min. Pressure-compensated piston opening adjustment (-N) and pilot-valve-less (-O) options. Pilot valve = solenoid valve (DSG-01) + throttle check modular valve (MSW-01). Coil (specify): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt). Wiring: Terminal box type (std) / DIN connector type (-N, opt).
| Product Code | Description | Brand | Spec | |
|---|---|---|---|---|
| FHG-02-30-13 | Pilot Operated Flow Control Valve FHG-02-30 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-O-13 | Pilot Operated Flow Control Valve FHG-02-30-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-13 | Pilot Operated Flow Control Valve FHG-02-30-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-02-30-N-O-13 | Pilot Operated Flow Control Valve FHG-02-30-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 02 | Max. Adjustable Flow: 30 L/min | Min. Adjustable Flow: 0.05 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 13 kg | Design No.: 13 | |
| FHG-03-125-13 | Pilot Operated Flow Control Valve FHG-03-125 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-O-13 | Pilot Operated Flow Control Valve FHG-03-125-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-13 | Pilot Operated Flow Control Valve FHG-03-125-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-03-125-N-O-13 | Pilot Operated Flow Control Valve FHG-03-125-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 03 | Max. Adjustable Flow: 125 L/min | Min. Adjustable Flow: 0.2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 17 kg | Design No.: 13 | |
| FHG-06-250-13 | Pilot Operated Flow Control Valve FHG-06-250 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-O-13 | Pilot Operated Flow Control Valve FHG-06-250-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-13 | Pilot Operated Flow Control Valve FHG-06-250-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-06-250-N-O-13 | Pilot Operated Flow Control Valve FHG-06-250-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 06 | Max. Adjustable Flow: 250 L/min | Min. Adjustable Flow: 2 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 32 kg | Design No.: 13 | |
| FHG-10-500-13 | Pilot Operated Flow Control Valve FHG-10-500 | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-O-13 | Pilot Operated Flow Control Valve FHG-10-500-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: No | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-13 | Pilot Operated Flow Control Valve FHG-10-500-N | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: Yes | Coil (RFQ): AC A100/A200 (std), A120/A240 (opt); DC D24 (std), D12/D48 (opt); AC-DC R200 (std), R100 (opt) | Wiring (RFQ): Terminal box type (std) / DIN connector type (-N, opt) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 | |
| FHG-10-500-N-O-13 | Pilot Operated Flow Control Valve FHG-10-500-N-O | Yuken | Type: Pilot Operated Flow Control Valve | Mounting: Sub-plate | Valve Size: 10 | Max. Adjustable Flow: 500 L/min | Min. Adjustable Flow: 4 L/min | Pressure-Compensated Piston Opening Adj.: Yes (-N) | Pilot Valve: No (-O) | Coil (RFQ): N/A (no pilot valve) | Wiring (RFQ): N/A (no pilot valve) | Check Valve: No | Max. Operating Pressure: 21 MPa | Min. Pilot Pressure: 1.5 MPa | Mass: 61 kg | Design No.: 13 |